Transition Networks TV Converter Box CSDTF1022 100 User Manual |
COMPLIANCE INFORMATION
UL Listed
C-UL Listed (Canada)
CISPR22/EN55022 Class A + EN55024
CE Mark
T1/E1 Twisted-Pair Copper to Fiber
Slide-In-Module Media Converters
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user’s own expense.
CSDTF10xx*-100
USER’S GUIDE
TRANSITION Networks CSDTF10xx-100 series media converters, designed to be
installed in a PointSystem™ Conversion Center™ chassis, encode and decode T1 or
E1 twisted-pair copper signals over duplex fiber-optic cable to extend the distance
and transmission reliability of high speed T1 or E1 data traffic.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
CSDTF1011-100
Provides an RJ-45 twisted pair copper
connector for T1 or E1 signals and a set
of RX/TX ST connectors to 850 nm
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
PWR
PWR
PWR
PWR
COL
SDC SDF PWR
LOOP
SDC SDF PWR
LOOP
SDC SDF PWR
RXF
LKS
LKM
LKS
LKM
LA
LKS
LKM
LKS
LKM
LNK
RXF
RXC
LOOP
RXC
TX
LKC
TX
TX
TX
TX
Link Alert
TX
RX
multimode duplex fiber-optic cable.
E
D
TX
RX
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen
werantwortlich ist.
SET
RX
TX
RX
TX
RX
TX
RX
TX
RX
CSDTF1012-100
0
50‰
Provides an RJ-45 twisted pair copper
connector for T1 or E1 signals and an
RX/TX ST connector to 1300 nm
RX
RX
RX
RX
Attention !
CFETF100
CSDTF100
CECF100
CFMFF100
CFM
CFMFF100
CFETF110
CFMFF100
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques
appropriées
singlemode duplex fiber-optic cable.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
CSDTF1013-100
CSDTF1015-100 (long haul)
Provides an RJ-45 twisted pair copper
connector for T1 or E1 signals and an
RX/TX SC connector to 850 nm
Provides an RJ-45 twisted pair copper
connector for T1 or E1 signals and an
RX/TX SC-LH connector to 1300 nm
singlemode duplex fiber-optic cable.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
multimode duplex fiber-optic cable.
CSDTF1014-100
CSDTF1022-100 (long haul)
Provides an RJ-45 twisted pair copper
connector for T1 or E1 signals and an
RX/TX SC-SM connector to 1300 nm
singlemode duplex fiber-optic cable.
Provides an RJ-45 twisted pair copper
connector for T1 or E1 signals and an
RX/TX ST connector to 1300 nm
singlemode duplex fiber-optic cable.
CSDTF10xx in the Network . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .7
Fault Isolation and Correction . . . . .8
Cable Specifications . . . . . . . . . . . .10
Technical Specifications . . . . . . . . .11
Compliance Information . . . . . . . . .12
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
*In CSDTF10xx model designation, 10
represents the T1 or E1 RJ-45 connector;
xx represents the selectable fiber connector
installed on the media converter.
Copyright Restrictions
© 2001, 2002 TRANSITION Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A.
Download from W33w2w01.S.Comanuals.com. All Manuals Search And Download.
Dry-Contact Relay
CABLE SPECIFICATIONS (continued)
RJ-45 dry-contact relay opens if power, signal detect/copper or signal
Twisted-Pair Copper Cable
detect/fiber are lost.
Operational rating on pins 3 and 6: 0-30VDC maximum 1A
Twisted pair connection requires two active pairs. The two active pairs
in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated
wire pairs (such as blue/white & white/blue, orange/white &
white/orange) for the active pins.
Relay
3
RJ-45
Category 3 or better twisted-pair copper wire is required. Either shielded
twisted-pair (STP) or unshielded twisted-pair (UTP) can be used.
6
T1:
Gauge
24 to 22 AWG
Attenuation
Differential Characteristic Impedance
2.6 dB/100 meters @ 1.0 MHz
100 Ω ±10%
Switch-Selectable Configurations
T1 COPPER RJ-45
E1:
Configured as either "long haul" or “short haul” on 100 ohm cable, with
Gauge
24 to 22 AWG
Attenuation
Differential Characteristic Impedance
2.6 dB/100 meters @ 1.0 MHz
120 Ω ±10%
a variety of selectable distance settings.
E1 COPPER RJ-45
Configured as either "long haul" or “short haul” on 120 ohm cable.
STRAIGHT-THROUGH/CROSSOVER RJ-45
Allows straight-through cable to be used where crossover-configuration
cable is required.
Switch-Selectable Functions
LOOPBACK TEST FUNCTION
A loopback switch facilitates installation and network debug procedures.
The path for the CSDTF10xx loopback is shown:
Fiber
TP
TP
TRANSMIT ALL ONES FUNCTION
A selectable Transmit All Ones switch on the fiber interface and on the
twisted-pair interface allows for insertion of an “all ones” pattern on that
interface when signal detect is lost, which creates an alarm condition at
the equipment connected to the interface.
INSTALLATION
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting switch and when installing Media Converter Slide-in-
Module in the Media Conversion Center. Failure to observe this caution could
result in damage to, and subsequent failure of, the Media Converter Slide-in-
Module.
CABLE SPECIFICATIONS
Fiber Cable
Bit error rate:
≤10-9
MULTIMODE
Set Loopback Test Switch
Fiber Optic Cable Recommended:
Optional:
62.5 / 125 µm multimode fiber
100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
850 nM
NOTE: The Loopback Test switch, located on Media Converter Slide-in-
Module front panel, allows the network administrator
to enable a loopback test for installation and network
debug procedures.
Loop
CSDTF1011-100
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Typical Maximum Cable Distance*:
CSDTF1013-100
min: -14.0 dBm
min: -25.0 dBm
2 kilometers
max: -12.0 dBm
max: -12.0 dBm
Use small flatblade screwdriver or similar device to set recessed switches.
Refer to drawing for switch locations.
850 nM
Set 3-Position Jumper
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Typical Maximum Cable Distance*:
min: -14.0 dBm
min: -25.0 dBm
2 kilometers
max: -12.0 dBm
max: -12.0 dBm
NOTE: Jumper is located on Media Converter Slide-in-Module circuit board.
Use small needle-nosed pliers or similar device to set
jumper. Refer to drawing for jumper positions.
SINGLEMODE
H
S
Fiber Optic Cable Recommended:
CSDTF1012-100
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Typical Maximum Cable Distance*:
CSDTF1014-100
9 µm singlemode fiber
1300 nM
HARDWARE MODE
HARDWARE Converter mode is determined by
4-position switch settings below.
min: -21.0 dBm
min: -25.0 dBm
8 kilometers
max: -14.0 dBm
max: -14.0 dBm
H
S
SOFTWARE Converter mode is determined by most-
recently-saved on-board microprocessor settings.
SOFTWARE MODE
1300 nM
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Typical Maximum Cable Distance*:
CSDTF1015-100 (long haul)
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Typical Maximum Cable Distance*:
CSDTF1022-100 (long haul)
Fiber-optic Transmitter Power:
Fiber-optic Receiver Sensitivity:
Typical Maximum Cable Distance*:
min: -21.0 dBm
min: -27.0 dBm
8 kilometers
max: -14.0 dBm
max: -14.0 dBm
Set MDI/MDI-X Switch
NOTE: The MDI/MDI-X switch, located on Media Converter Slide-in-Module
circuit board, allows the network administrator to use straight-through cable
in installations where crossover-configuration cable is required.
1300 nM
min: -15.0 dBm
min: -27.0 dBm
15 kilometers
1300 nM
min: -15.0 dBm
min: -25.0 dBm
15 kilometers
max: -5.0 dBm
max: -14.0 dBm
Use small flatblade screwdriver or similar device to set recessed switches.
Refer to drawing for switch settings.
max: -5.0 dBm
max: -14.0 dBm
MDI-X
MDI
*Actual distance dependent upon physical characteristics of network installation.
1
2
1
2
RTIP
TTIP
RTIP
RTIP
Twisted
Pair #1
Twisted
Pair #1
RRING
TRING
RRING
RRING
4
5
TTIP
RTIP
4
5
TTIP
TTIP
Twisted
Pair #2
Twisted
Pair #2
TRING
RRING
TRING
TRING
Connectors for unlike devices
Connectors for like devices
Set 8-Position Switch
NOTE: The eight-position switch, located on Media Converter Slide-in-
Module circuit board, allows the network administrator to configure the
media converter for network conditions.
Use small flatblade screwdriver or similar device to set recessed switches for
site installation. Refer to drawings at right for eight-position switch settings.
NOTE:
LEFT SWITCH SET
FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
T1 must be selected (LEFT
SWITCH SET #4 UP) for RIGHT
SWITCH SET to have any effect.
1
2
3
4
1
2
3
4
If E1 is selected (LEFT SWITCH SET
#4 DOWN), RIGHT SWITCH SET is
ignored and the default is E1
3.0V 120Ω cable.
toward chassis
toward network connectors
1.
Is the P(o)W(e)R LED on the media converter illuminated?
NO
NETWORK Switch Settings
1 2 3 4
•
•
Is the media converter inserted properly into the chassis?
Is the power cord properly installed in the chassis and at the
external power source?
If T1 and short haul are
Transmit All Ones onto Fiber
on loss of TP Carrier Detect
UP= Enabled
selected (LEFT SWITCH SET #3
UP, #4 UP), but RIGHT SWITCH
SET is not set to a valid short
haul value, the short haul
default is DSX-1 0’-133’ cable.
•
•
Does the external power source provide power?
Contact Technical Support: (800) 260-1312.
YES
•
Transmit All Ones onto TP
on loss of FiberCarrier Detect
UP= Enabled
Proceed to step 2.
If T1 and long haul are
selected (LEFT SWITCH SET #3
DOWN, #4 UP), but RIGHT
SWITCH SET is not
2.
Is the SDF (Signal Detect/Fiber) LED illuminated?
NO
Long Haul/Short Haul (T1 only)
UP= Short Haul
•
Check fiber cables for proper connection.
•
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other media converter.
Contact Technical Support: (800) 260-1312.
set to a valid
long haul value,
the long haul
default is 0db
100Ω cable.
KEY
=
UP
•
T1/E1 Selection
UP= T1
YES
=
DOWN
•
Proceed to step 3.
3.
Is the SDC (Signal Detect/Copper) LED illuminated?
NO
SHORT HAUL Switch Settings*
1 2 3 4
RIGHT SWITCH SET
1
2
3
4
1
2
3
4
•
•
Check twisted pair cables for proper connection.
Check RJ-45 Pinning Switch for correct twisted pair cable
configuration.
DSX-1 533'-655'
100 ohm cable
toward chassis
toward network connectors
•
Check integrity of device attached to media converter by twisted-
pair cable.
DSX-1 399’-533’
100 ohm cable
LONG HAUL Switch Settings*
1 2 3 4
•
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
•
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
-22.5db
DSX-1 266’-399’
100 ohm cable
100 ohm cable
-15db
100 ohm cable
DSX-1 133'-266'
100 ohm cable
-7.5db
100 ohm cable
DSX-1 1 0’-133’
and ANSI T1.403
100 ohm cable
0db
100 ohm cable
DSX-1 6.0V
100 ohm cable
*Right switch set #4 not used
*Right switch set #4 not used
Power the Slide-In-Module
INSTALLATION (continued)
Install Slide-In-Module in PointSystem™ Chassis
NOTE: The Slide-In-Module is powered through the Conversion
Center™.
CAUTION: Any Slide-in-Module installation slot in which a Media Converter
Slide-in-Module is NOT installed MUST have a protective plate instead.
Failure to observe this caution will void Class A and/or Class B compliance.
OPERATION
NOTE: Install Media Converter Slide-in-Modules in any slot, in any order.
After installation, the media converter should function without operator
intervention.
1. Carefully slide Media Converter Slide-in-Module into installation slot,
aligning Media Converter Slide-in-Module with installation guides.
Status LEDs
NOTE: Ensure that Slide-in-Module is firmly seated against backplane.
Use the status LEDs to monitor media converter operation in the network.
2. Secure Slide-in-Module by securing panel fastener screw (attached to
Slide-in-Module) to chassis front.
SDC
Signal Detect/Copper - Steady LED
indicates twisted-pair copper link is up.
3. Install protective plate at EVERY Slide-in-Module installation slot in
which a Media Converter Slide-in-Module is not installed by securing
attached protective plate panel fastener screw to chassis front.
SDC SDF PWR
LOOP
Flashing LED (once/second) indicates
transmitting on link if other link is down.
Flashing LED (5 times/second) indicates All
Ones detected on Link.
Install Cable
COPPER
SDF
Signal Detect/Fiber - Steady LED indicates fiber link is up.
T1 100 OHM (RJ-45 CONNECTOR)
Flashing LED (once/second) indicates transmitting on link if
other link is down.
1. Locate or build twisted-pair cables that are compliant with
specifications on page 10, with RJ-45 plug connectors at both ends.
Flashing LED (5 times/second) indicates All Ones detected on
Link.
2. Ensure that MDI/MDI-X switch is set according to network
conditions.
P(o)W(e)R Steady green LED indicates connection to external AC power.
Using SNMP*
3. Connect RJ-45 plug connector at one end of cable to media
converter RJ-45 jack connector.
Use SNMP at an attached terminal or at a remote location to:
4. Connect RJ-45 plug connector at other end of cable to network
equipment.
•
Monitor media converter by monitoring:
Media Converter Power
Fiber Link Status
FIBER
1. Locate or build fiber cables that are compliant with specifications
on page 9, with male two-stranded TX to RX connectors installed at
both ends.
Copper Link Status
Hardware Switch settings
AIS detected on Fiber
TX
TX
AIS detected on Copper
•
Enter network commands that:
Enable/disable Loop-back on Fiber
RX
RX
Enable/disable Transmit All Ones on Fiber when Copper is down
Enable/disable Transmit All Ones on Copper when Fiber is down
Power Down Media Converter.
2. Connect cable with connector installed at TX location on media
converter to RX location on attached device.
3. Connect cable with connector installed at RX location on media
*See the on-line documentation that comes with TRANSITION Networks
FocalPoint software for applicable commands and usage.
™
converter to TX location on attached device.
|