User’s Guide
CPSMP-120
AC Power Supply Module
• PointSystem™
• CPSMC13xx-100 Accessory
0
I
The Transition Networks CPSMP-120
power supply is an AC slide-in-module
that provides optional, redundant
power to the CPSMC13xx-100
PointSystem™ 13-slot chassis and any
installed media converter slide-in-
modules and management modules.
The figure below illustrates the components of the CPSMP-120 power supply:
•
An On/Off switch that, when set to “I”, allows the power supply module
to supply power to the chassis, and any installed modules.
•
A panel fastener screw that secures the power supply module to the
chassis.
•
•
A power LED indicator.
A handle for installing and removing the power supply module to/from
the chassis.
•
•
A fuse installed in a fuse holder.
An external power connector that supplies power from a standard AC
wall outlet.
On/Off Switch
Panel Fastener Screw
Power LED
Handle
Fuse Holder
External Power Connector
Install the CPSMP-120 . . . . . . . . .3
Connect to External Power . . . . . .4
Replace the CPSMP-120 . . . . . . . .5
Replace the Fuse . . . . . . . . . . . . .7
Technical Specifications . . . . . . . .8
Troubleshooting . . . . . . . . . . . . . .9
Compliance Information . . . . . . .11
CPSMP-120
WARNING: Do not connect the power supply module to the external power
source before installing it into the chassis. Failure to observe this caution could
result in equipment damage and/or personal injury or death.
Connect to External Power
CAUTION: Ensure that the On/Off switch on the power supply module is set
to “0” when connecting to the external power source. Failure to observe
this caution could result in damage to, and subsequent failure of, the power
supply module.
Replace the CPSMP-120
CAUTION: Ensure that the power supply module has been disconnected
from the external power source and the module’s On/Off switch has been
set to “0”. Failure to observe this caution could result in damage to, and
subsequent failure of, the power supply module.
To power the CPSMP-120 power supply module:
1. Set the On/Off switch on the power supply module to “0”.
2. Connect the female end of the AC power cord to the male end of the
external power connector.
NOTE: The CPSMP-120 power supply module may be “hot swapped” (i.e.,
replaced while the chassis is in operation) provided the module to be
replaced has been disconnected from its external power source and the
module’s On/Off switch has been set to “0”.
3. Connect the male end of the AC power cord into the correct voltage AC
rack or wall socket.
4. Set the power supply module power switch to “I”.
To replace the CPSMP-120 power supply module:
5. Verify that the CPSMP-120 power supply module is powered by
observing the illuminated power LED.
1. Ensure the On/Off switch on the power supply module is set to “0”.
2. Disconnect the the male end of the AC power cord from the AC rack or
wall socket.
Panel Fastener Screw
3. Disconnect the female end of the AC power cord from the external power
connector.
Power LED
4. Rotate the attached panel fastener screw counter-clockwise.
On/Off
Switch
External Power Connector
AC Power Cord
0
I
Panel
Fastener
0
I
Screw
5. Carefully slide the power supply module to be replaced out of the
chassis.
5
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
4
CPSMP-120
Replace the CPSMP-120 -- Continued
Replace the Fuse
6. Carefully slide the replacement power supply module into the installation
slot, aligning the module with the installation guides.
CAUTION: Ensure that the power supply module has been disconnected
from the external power source and the module’s On/Off switch has been
set to “0”. Failure to observe this caution could result in damage to, and
subsequent failure of, the power supply module.
NOTE: The CPSMP-120 power supply module may be “hot swapped” (i.e.,
serviced while the chassis is in operation) provided the module to be serviced
has been disconnected from its external power supply and the module’s
On/Off switch has been set to “0”.
0
I
Panel
Fastener
Screw
0
I
To replace the fuse in the CPSMP-120 power supply module:
1. Ensure the On/Off switch on the power supply module is set to “0”.
2. Disconnect the the male end of the AC power cord from the AC rack or
wall socket.
7. Ensure that the power supply module is firmly seated inside the chassis.
8. Rotate the attached panel fastener screw clockwise to secure the power
supply module to the chassis.
3. Disconnect the female end of the AC power cord from the external power
connector.
9. See the “Connect to External Power” section (page 4) for instructions on
re-connecting the power supply module to the external power source.
On/Off Power
LED
Switch
Fuse Holder
Fuse
4. From the inside edge of the power receptacle, insert a small flat blade
screwdriver into the groove on the front, inside edge of the fuse holder
and carefully pry the fuse holder from the power supply module.
5. Carefully remove the fuse from the fuse holder.
6. Install a same size and rating replacement fuse in the fuse holder.
7. Return the fuse holder and fuse to the installation position in the power
supply module. Snap the fuse holder into place.
8. See the “Connect to External Power” section (page 4) for instructions on
re-connecting the power supply module to the external power source.
7
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
6
CPSMP-120
Technical Specification
Troubleshooting
For use with Transition Networks Model CPSMP-120 or equivalent.
If the power supply module fails, isolate and correct the failure by determining
the answers to the following questions and then taking the indicated action:
Standards
Dimensions
Weight
UL Listed; FCC & CISPR Class A; CE Mark
3.4" x 2.5" x 11.0" (86 mm x 64 mm x 279 mm)
1.8 lb (0.82 kg) (approximate)
1.
Is the power LED on the CPSMP-120 power supply module
illuminated?
NO
Power Input
100-240 V, 50/60Hz, 0.4 to 1.0 Amp
(typical with a fully-loaded chassis)
•
•
Is the power supply module inserted properly into the chassis?
Is the power supply module properly connected to the external
power source?
Power Output
Fuse
12VDC at 10.83 Amp (maximum)
4 Amp, 250V
•
•
Does the external power source provide power?
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
MTBF
220,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
538,224 hours (Bellcore7 V5.0)
YES
•
Environment
Tmra*:
0 to 50°C (32 to 122°F )
-20 to 85°C (-4 to 185°F)
10 to 90%, non condensing
0 to 10,000 feet
Proceed to step 2.
Storage Temp:
Humidity:
Altitude:
2.
Is the fuse on the CPSMP-120 power supply intact?
NO
•
CAUTION: See the “Replace the Fuse” section (page 7) for the
proper method for replacing the fuse to the CPSMP-120 power
supply module.
Warranty
Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this power supply
module depends on the physical characteristics and the installation configuration
of the Transition Networks PointSystem™ chassis in which this power supply will
be installed.
•
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
•
For the most up-to-date information on the CPSMP-120 power supply module,
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
9
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
8
CPSMP-120
Contact Us
Compliance Information
UL Listed
Technical Support
Technical support is available 24 hours a day.
US and Canada:
International:
C-UL Listed (Canada)
CISPR22/EN55022 Class A
CE Mark1
1-800-260-1312
00-1-952-941-7600
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus
set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
Address
European Regulations
Warning This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, USA
telephone:
toll free:
fax:
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für
entsprechende Gegenmaßnahmen werantwortlich ist.
952-941-7600
800-526-9267
952-941-2322
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit
risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de
prende les measures spécifiques appropriées.
DECLARATION OF CONFORMITY
Name of Mfg:
Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model:
Part Number(s):
Regulation:
CPSMP-120 Redundant Power Supply 120/240 VAC
CPSMP-120
EMC Directive 89/336/EEC
Purpose: To declare that the CPSMP-120 to which this declaration refers is in
conformity with the following standards.
EN 55022:1998+A1:2000 Class A; EN 55024:1998; FCC Part 15 Subpart B; UL 1950;
EN 61000-3-2:2000; EN 61000-3-3:1995+A1:2001; 21CFR Subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
_June 8, 2001_____
Stephen Anderson, Vice-President of Engineering
Date
11
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
10
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2001, 2004 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any
means - graphic, electronic, or mechanical - without written permission from Transition
Networks.
Printed in the U.S.A.
33209.C
|