Polar Heart Rate Monitor FT7 User Manual

ENGLISH  
Polar FT7  
User Manual  
 
ENGLISH  
1. BENEFITS OF YOUR POLAR FT7 TRAINING COMPUTER  
Benefits of Your Polar FT7 Training Computer  
3
 
 
ENGLISH  
2. GET STARTED  
Get to Know Your Polar FT7 Training Computer  
Training computer records and  
displays your heart rate and other  
data during training.  
WearLink® + transmitter transmits  
the heart rate signal to the  
training computer. The WearLink+  
transmitter consists of a  
connector (A) and strap (B).  
The latest version of this user  
manual can be downloaded at  
For video tutorials, go to  
FT7 Buttons and Menu  
UP:  
OK:  
DOWN:  
BACK:  
LIGHT:  
alarm or select time zone  
ON/OFF or lock  
LIGHT once during recording and the  
buttons  
backlight will be activated by pressing any button. Night mode is  
switched off when the FT7 goes back to Time mode.  
4
Get Started  
 
     
ENGLISH  
Start With Basic Settings  
To activate your Polar FT7 training computer, press and hold any button for one second. Once the FT7 is  
activated, it cannot be switched off.  
1. Language: Select Deutsch, English, Español, Fr  
, Italiano, Português, Suomi or Svenska with  
UP/DOWN. Press OK.  
2. Please enter basic settings is displayed. Press OK.  
3. Select Time format.  
4. Enter Time.  
5. Enter Date.  
6. Select Units. Set metric (KG, CM) or imperial (LBS, FT). By selecting lbs/ft, calories are displayed as  
CAL, otherwise they are shown as KCAL. Calories are measured as kilocalories.  
7. Enter Weight.  
8. Enter Height.  
9. Enter Date of birth.  
10. Select Sex.  
11. Settings OK? is displayed. Confirm and save the settings, select Yes. Basic settings complete is  
displayed and the FT7 enters Time view. To change the settings, select No. Please enter basic settings  
is displayed. Re-enter your basic settings.  
You can modify your user information at a later date. For more information, see Settings (page 12).  
Get Started  
5
 
 
ENGLISH  
3. TRAINING  
Wear the Transmitter  
1. Wet the electrode areas of the  
strap well under running water.  
2. Attach the connector to the  
strap. Adjust the strap length to  
fit it tightly but comfortably.  
3. Tie the strap around your chest,  
just below the chest muscles,  
and attach the hook to the other  
end of the strap.  
4. Check that the wet electrode  
areas are firmly against your  
skin and that the Polar logo of  
the connector is in a central  
and upright position.  
Detach the connector from the strap after every use, to maximize the transmitter battery lifetime. Sweat and  
moisture may keep the electrodes wet and the transmitter activated. This will reduce the transmitter battery life.  
For more detailed information on how to maintain your transmitter, see Washing Instructions for  
Start Training  
1. Wear the transmitter and the training computer.  
2. Press OK and select Start. Wait until your heart rate is displayed and then press OK to start the  
recording.  
To modify training sound, heart rate view, heart touch or zone limits before starting the recording of the  
training session, select Settings > Training Settings. For more information, see Training Settings (page 12).  
Your training file is saved only when the recording has lasted for more than one minute.  
Exercise duration timer  
The FT7 has an exercise duration timer, which enables you to just record exercise time without using the  
transmitter.  
1. To time your exercise press OK twice Started is displayed.  
2. Press DOWN until you can see the DURATION/ TIME OF DAY display.  
3. You can follow the elapsed time. When Check heart rate transmitter! appears, press OK to continue  
timing.  
4. To stop the timing, press BACK twice.  
5. The summary will follow and you can check the elapsed time.  
Burn Fat or Improve Fitness  
While training, the Polar FT7 displays your optimal training intensity for burning fat and improving fitness.  
These intensities may vary depending on your daily physical and mental condition. When you start  
6
Training  
 
       
ENGLISH  
recording a training session, the FT7 analyses your current condition and, if necessary, will adjust the  
intensities accordingly.  
This intelligent training computer can detect your body's daily state from your heart rate and heart rate  
variability. When your body is recovered from previous training sessions and is not tired or stressed, then  
you are prepared for more intensive training.  
The effect of your training is displayed on the wrist unit in real time. The fat-burning and fitness intensity  
zones are separated by a vertical dotted line. This line is automatically detected by the FT7, and shifted  
according to your current condition.  
EFFECT on the display will change to FATBURN or FITNESS depending on which zone  
you are in.  
1. Your current heart rate  
2. Limit heart rate value between fat-burning and fitness intensity zones.  
~ disappears as the FT7 adjusts the intensity zones to correspond to  
your current condition when necessary.  
FATBURN (heart symbol is on the left side of the line)  
In fatburn zone, training intensity is lower, and the source of energy is mainly fat.  
Therefore, fat burns efficiently and your metabolism, mainly fat oxidation, increases.  
FITNESS (heart symbol is on the right side of the line)  
In fitness zone, training intensity is higher and you are improving your cardiovascular  
fitness i.e. strengthening your heart and increasing blood circulation to muscles and  
lungs. The main energy source is carbohydrates.  
You can lock into the Fatburn or Fitness zones, depending on your goal for that particular training session.  
While in the desired zone, press OK for one second to lock. Fat burning zone locked or  
Fitness zone locked is displayed. The wrist unit gives a sound if you are training too  
hard or too light. For instance, fatburn zone is locked in this image. To unlock a zone,  
press OK for one second.  
During Training  
The following information is displayed during training recording. Press UP/DOWN to change the view.  
HEART RATE  
Your current heart rate  
CALORIES  
Calories burnt during the training session.  
Training  
7
 
 
ENGLISH  
DURATION  
The duration of your training session  
TIME OF DAY  
Time of day.  
Fitness(heart symbol is on the right side of the line)  
Your current heart rate. You are exercising on a fitness improving zone.  
FT7 has a display memory function which remembers the last display (for example the calorie display) you have  
used during your training session. Next time when you start a training session, the display will automatically select  
the calorie display.  
Heart T  
By bringing the training computer near  
the transmitter connector during training  
the time of day displayed. The backlight  
also lights up, providing that you have  
pressed the LIGHT button during the  
training session. Set the HeartTouch  
function On/Off in Settings > Training  
Settings > HeartTouch.  
Pause/Stop Training  
1. To pause your training session recording, press BACK, Continue/ Exit is displayed. To continue recording  
press OK.  
If you have not continued recording in five minutes, the FT7 will automatically remind you to do so by a  
sound. You will hear the sound every ten minutes until session recording is either continued or stopped.  
Note: If the sound is off mode then display remains in pause mode until user makes the next selection,  
puts FT7 onto FlowLink or the battery runs out.  
2.  
To stop the recording, press BACK once more. Stopped is displayed.  
See Training Summary (page 9) for information on training session feedback.  
Training session feedback will be shown only if the recording has lasted more than ten minutes.  
Detach the transmitter connector from the strap and rinse the strap under running water after every use.  
Wash the strap regularly in a washing machine at 40ºC/104ºF at least after every fifth use. For more  
information on caring the transmitter, see Washing Instructions for WearLink+ Transmitter (page 14)  
8
Training  
 
 
ENGLISH  
4. AFTER TRAINING  
Training Summary  
The Polar FT7 displays a training summary after each training session:  
DURATION  
The duration of your training session  
CALORIES  
The amount of burnt calories during the training session.  
AVERAGE  
Your average heart rate of the training session  
MAXIMUM  
Your maximum heart rate of the training session  
FAT BURN  
Time spent in the fat burning zone  
FITNESS  
Time spent in the fitness improving zone  
Review Training Data  
To review your training data, select MENU > Data. Then select Training files, Week summaries, Totals since  
xx.xx.xx, Delete files or Reset totals.  
Training Files  
To review your past training data, select MENU > Data > Training files. Then select the date and time you  
want to view.  
File creation day: xx.xx.xx  
File creation time: xx:xx  
Each bar represents one training session file. Select the training session you want to  
view  
DURATION  
Duration of your training session  
CALORIES  
The amount of burnt calories during the training session  
AVERAGE  
Average heart rate of the training session  
MAXIMUM  
Maximum heart rate of the training session  
FAT BURN  
Time spent in the fat burning zone  
FITNESS  
Time spent in the fitness improving zone  
After Training  
9
 
       
ENGLISH  
Delete Files  
The maximum number of training files is 99. When the Training files memory becomes full, the oldest  
training file is overwritten by the most most recent one. To save the training file for a longer period of  
Data > Delete > Training file > OK.  
OK.  
Delete file? is displayed. Select Yes.  
Remove from totals? is displayed. To remove the file from totals, select Yes.  
Delete all files  
Data > Delete > All files > OK.  
Delete all files? is displayed. Select Yes, All files deleted is displayed.  
To cancel file deletion, press BACK until Time of day view is displayed.  
Week Summaries  
To review your weekly training summary select MENU > Data > Week summaries  
WEEK  
Week start date and end date  
File browser  
DURATION  
The duration of your training sessions  
SESSIONS  
The number of training sessions during the selected week.  
CALORIES  
The amount of calories burnt during the week  
Reset Week Summaries  
To reset week summaries select Data > Reset week summaries > OK. Reset weeks? is displayed. Select  
Yes to reset week summaries.  
Totals  
To review your training totals select MENU > Data > Totals since xx.xx.xxxx  
DATA  
Totals since 01.09.2009  
10  
After Training  
 
   
ENGLISH  
DURATION  
The total duration of training sessions  
SESSIONS  
The total number of training sessions  
CALORIES  
The total amount of calories burnt during your training sessions  
Reset Totals  
To reset totals, select Data > Reset totals and Yes.  
Transfer Data  
For a long-term follow-up, store all your training files at polarpersonaltrainer.com web service. There you  
can view detailed information of your training data and get a better understanding of your training. With  
Polar FlowLink* it is easy to transfer training files to the web service. Alternatively you can transfer your  
training data manually to polarpersonaltrainer.com.  
How to set your PC for data transmission  
1. Register at polarpersonaltrainer.com  
2. Download and install the Polar WebSync software on your computer at polarpersonaltrainer.com.  
3. WebSync software is automatically activated when the box "Launch the Polar WebSync" is ticked at the  
end of the installation.  
4. Plug in your FlowLink in the USB port of the computer. The DATA symbol turns to yellow when FlowLink  
is connected to your PC. Place your training computer onto FlowLink, display facing down.  
5. Follow the data transfer process and the instructions for downloading the data, from the WebSync  
Software on your computer screen. For further instructions on data transfer, see polarpersonaltrainer.com  
"Help".  
To transfer data in the future follow the points 4 and 5 as instructed above.  
* Optional Polar FlowLink required.  
After Training  
11  
 
 
ENGLISH  
5. SETTINGS  
Watch Settings  
Select the value you want to change and press OK. Adjust the values with UP/DOWN and confirm with OK.  
Select Settings > Watch, time and date .  
Alarm: Set alarm Off or On. If you select On, set the hours and minutes. Press BACK to stop the alarm or  
UP/DOWN/OK to snooze for 10 minutes. The alarm cannot be used during training.  
Time: Select Time 1 and set the time format, hours and minutes. Select Time 2 to set time for another time  
zone by adding or subtracting hours. In the Time view, you can quickly change from Time 1 to Time 2 by  
pressing and holding DOWN. When Time 2 is selected, 2 is displayed at the bottom right corner of the  
display.  
Time zone: Select time zone 1 or 2.  
Date: Set the date.  
Watch face: Select Time only, Time and logo or Birthday logo (Selectable only on birthday). To change the  
Watch face quickly, press and hold UP, Watch face changed is displayed.  
You can create a logo with a picture editing program and transfer it to your Polar FT7 Training Computer by  
using the Polar WebSync software. For more information go to polar.fi/support  
Training Settings  
Select Settings > Training settings  
Training sounds: Select Off or On.  
Heart rate view : Set the FT7 to display your heart rate as Beats per minute (BPM) or as Percent of  
maximum (% OF MAX).  
BPM: The measurement of the work your heart does, expressed as the number of beats per minute.  
% OF MAX: The measurement of the work your heart does, expressed as % of your heart rate reserve.  
HeartTouch: Select On or Off. By bringing the training computer near the transmitter connector during  
training the time of day displayed. The backlight also lits up, providing that you have pressed the LIGHT  
button during the training session.  
Heart rate upper limit helps you to train within your personal target heart rate zone (e.g. advised by a  
doctor). Set upper heart rate limit On and adjust the limit with UP/DOWN and press OK.  
User Information  
Select Settings > User Information  
Weight: Enter your weight.  
Height: Enter your height.  
Date of birth: Enter your date of birth  
Sex: Select MALE or FEMALE.  
Maximum heart rate is the highest number of heartbeats per minute (bpm) during maximum physical  
exertion. Change the default value only if you know your laboratory-measured value.  
General Settings  
Select Settings > General settings .  
Button sounds: Select button sounds On or Off.  
Units: Select Metric (kg/km) or Imperial (lb/ft). By selecting lb/ft, calories are displayed as Cal,  
otherwise they are shown as kcal. Calories are measured as kilocalories.  
: Select the starting day of the week Monday, Saturday or Sunday.  
12  
Settings  
 
         
ENGLISH  
Language: Select Deutsch, English, Español, Fr  
or Svenska.  
Settings  
13  
 
ENGLISH  
6. IMPORTANT INFORMATION  
services to better meet your needs.  
The username for your Polar Account is always your email address. The same username and password are valid for  
Polar product registration, polarpersonaltrainer.com, Polar discussion forum and Newsletter registration.  
Caring for Your FT7 Training Computer  
Training computer: Clean with a mild soap and water solution, dry with towel. Do not press buttons under  
water. Never use alcohol or any abrasive material (steel wool or cleaning chemicals). Keep in a cool and  
dry place. Do not store in a damp environment, in non-breathable material (a plastic bag or a sports bag)  
nor with conductive material (a wet towel). Do not expose to direct sunlight for extended periods.  
Washing Instructions for WearLink+ Transmitter  
WearLink+ transmitter: Detach the transmitter connector from the strap and rinse the strap under running  
water after every use. Dry the connector with a soft towel. Never use alcohol or any abrasive material (steel  
wool or cleaning chemicals).  
Wash the strap regularly in a washing machine at 40ºC/104ºF or at least after every fifth use. This ensures  
reliable measurement and maximizes the life span of the transmitter. Use a washing pouch. Do not soak,  
spin-dry, iron, dry clean or bleach the strap. Do not use detergent with bleach or fabric softener. Never put  
the transmitter connector in the washing machine or drier!  
Dry and store the strap and the transmitter connector separately to maximize the transmitter battery  
lifetime. Wash the strap in a washing machine before long-term storage and always after use in pool water  
with high chlorine content.  
Service  
During the two-year guarantee/warranty period we recommend that you have service done by an authorized  
Polar Service Center only. The warranty does not cover damage or consequential damage caused by service  
not authorized by Polar Electro.  
Changing Batteries  
The FT7 and WearLink+ both have a user changeable battery. To change the battery yourself, please follow  
the instructions carefully.  
Please note the following:  
alarms set prior to the appearance of the low battery indicator will remain active.  
To change the battery yourself:  
When changing the battery, make sure the sealing ring is not damaged, in which case you should replace  
it with a new one. You can purchase the sealing ring/battery kits at well-equipped Polar retailers and  
authorized Polar Services. In the USA and Canada, the additional sealing rings are available at authorized  
Keep the batteries away from children. If swallowed, contact a doctor immediately.  
Batteries should be disposed of properly according to local regulations.  
When handling a new, fully charged battery, avoid clasp-like contact, i.e. simultaneously from both sides,  
14  
Important Information  
 
         
ENGLISH  
with metal or electrically conducting tools, like tweezers. This may short circuit the battery, causing it to  
discharge more rapidly. Typically, short circuiting does not damage the battery, but may decrease the  
capacity and thus the lifetime of the battery.  
1. Open the battery cover with a coin by turning it  
from CLOSE to OPEN.  
2.  
(2a), remove the battery cover and lift the  
battery out carefully with a suitable sized  
small rigid stick or bar, for instance, a  
toothpick. However, prefer a non-metal tool  
for wrenching the battery out. Be careful not  
to damage the metal sound element (*) or the  
grooves. Insert a new battery inside the cover  
with the positive (+) side facing the cover.  
place the battery inside the cover with the  
positive (+) side facing the cover.  
3. Replace the old sealing ring with a new one,  
fitting it snuggly in the cover groove to ensure  
water resistance.  
4. Put the cover back on and turn it clockwise to  
CLOSE.  
5. Re-enter the basic settings if you changed the  
training computer batteries.  
Danger of explosion if the battery is replaced with wrong type.  
Precautions  
Your Polar FT7 training computer is designed to help you achieve personal fitness goals and indicate the  
level of physiological strain and intensity during training sessions. No other use is intended or implied.  
Minimizing Possible Risks  
Training may include some risk. Before beginning a regular training program, answer the following  
questions concerning your health status. If you answer yes to any of these questions, consult a physician  
before starting any training program.  
Note that in addition to training intensity, medication for heart conditions/blood pressure/psychological  
conditions/asthma/breathing/etc, as well as some energy drinks, alcohol, and nicotine may also affect  
heart rate.  
It is important to be sensitive to your  
If you feel unexpected pain or  
excessive fatigue when training, stop the exercise or continue at a lighter intensity.  
If you have a pacemaker, defibrillator or other implanted electronic device, you use the Polar FT7 at your  
Important Information  
15  
 
 
ENGLISH  
own risk. Before starting use, take a maximal training stress test under the supervision of a physician. The  
test is to ensure the safety and reliability of the simultaneous use of the pacemaker and the Polar FT7.  
If you are allergic to any substance that comes into contact with your skin or if you suspect an allergic  
reaction due to using the product, check the listed materials in Technical Specifications. To avoid any  
skin reaction to the transmitter, wear it over a shirt. Moisten the shirt well under the electrodes to ensure  
flawless operation.  
The combined impact of moisture and intense abrasion may cause a black color to come off the  
surface, possibly staining light-colored clothes. If you use perfume or insect repellent on your skin, you must  
ensure that it does not come into contact with the training computer or the transmitter.  
Exercise equipment with electronic components may cause interfering stray signals.  
To tackle these problems, try the following:  
1. Remove the transmitter from your chest and use the exercise equipment as you would normally.  
2. Move the training computer around until you find an area in which it displays no stray reading or does not  
flash the heart symbol. Interference is often worst right in front of the display panel of the equipment,  
while the left or right side of the display is relatively free of disturbance.  
3. Put the transmitter back on your chest and keep the training computer in this interference-free area as  
much as possible.  
If the Polar FT7 still does not work, the piece of equipment may be electrically too noisy for wireless heart  
rate measurement.  
Water Resistance of the Polar FT7 Training Computer  
Polar FT7 may be worn when swimming. To maintain water resistance, do not press buttons under water.  
according to International Standard ISO 2281. Products are divided into three categories according to  
their water resistance. Check the back of your Polar product for the water resistance category, and  
compare it to the chart below. Please note that these definitions do not necessarily apply to products of  
other manufacturers.  
Marking on case back  
Water resistant characteristics  
Water resistant  
Protected against wash splashes, sweat, raindrops etc. Not suitable for  
swimming.  
Water resistant 30 m/50 m  
Suitable for bathing and swimming  
WR 30M/ WR 50M  
Water resistant 100 m  
Suitable for swimming and snorkeling (without air tanks)  
WR 100M  
Troubleshooting  
If you don't know where you are in the menu, press and hold BACK until the time of day is displayed.  
If there are no reactions to any buttons or the FT7 displays unusual readings, reset the training computer  
by pressing four buttons (UP, DOWN, BACK and LIGHT) simultaneously for four seconds. The display will  
go blank for a moment. Press OK and Please enter basic settings will shortly be displayed. Enter time  
and date. With long press BACK the display returns to time of day view. All other settings except time and  
date will be saved.  
If the heart rate reading becomes erratic, extremely high or shows nil (00), make sure that there are no  
other heart rate transmitters within 1 m/3 ft and that the transmitter strap/the textile electrodes fit snugly  
and are moistened, clean and undamaged.  
16  
Important Information  
 
 
ENGLISH  
If the heart rate measurement does not work with the sports apparel, try using the strap. If it works, the  
problem is most probably in the apparel. Check that the electrode areas of the apparel are clean. Before  
washing the apparel, check the washing instructions. If the heart rate measurement still does not work,  
please contact the apparel retailer/manufacturer.  
Strong electromagnetic signals can cause erratic readings. Electromagnetic disturbances may occur near  
high-voltage power lines, traffic lights, overhead lines of electric railways, electric bus lines or trams,  
televisions, car motors, bike computers, some motor driven training equipment, cellular phones, or at  
electric security gates. To avoid erratic readings, move away from possible sources of disturbance.  
If the abnormal reading continues despite moving away from the source of disturbance, slow down and  
check your pulse manually. If you feel it corresponds to the high reading on the display, you may be  
experiencing cardiac arrhythmia. Most cases of arrhythmia are not serious, but consult your doctor  
nevertheless.  
If heart rate measurement does not work despite the actions mentioned previously, the battery of your  
transmitter may be empty.  
A cardiac event may have altered your ECG waveform so that the transmitter is not able to detect it. In this  
case, consult your physician.  
Technical Specifications  
FT7 Training Computer  
CR1632  
Battery type  
Battery life  
Operating temperature  
Back cover  
Average 11 months (training 1 h/day, 7 days/week)  
-10  
Polyamide  
Wrist strap material  
Wrist strap buckle  
Polyurethane  
Stainless steel complying with the EU Directive 94/27/EU and amendment  
1999/C 205/05 on the release of nickel from products intended to come into  
direct and prolonged contact with the skin.  
Better than ± 0.5 seconds/day at 25  
Watch accuracy  
Accuracy of heart rate measurement  
± 1% or ± 1 bpm, whichever larger, definition applies to steady state  
conditions.  
Water resistance  
30m (Suitable for bathing and swimming)  
WearLink+ Transmitter  
CR 2025  
Battery type  
Battery life  
Average 700 hours of use  
O-ring 20.0 x 1.0 Material FPM  
-10  
Battery sealing ring  
Operating temperature  
Connector material  
Strap material  
Polyamide  
35% Polyester, 35% Polyamide, 30% Polyurethane  
30m (Suitable for bathing and swimming)  
Water resistance  
Limit Values  
23 h 59 min 59 s  
15 - 240 bpm  
0 - 9999 h 59 min 59 s  
0 - 999999 kcal/Cal  
65 535  
Chronometer  
Heart rate  
Total time  
Total calories  
Total exercise count  
Year of birth  
1921 - 2020  
Polar FlowLink and Polar WebSync 2.1 (or newer)  
PC MS Windows (2000/XP/Vista), 32 bit, Microsoft .NET Framework Version  
2.0  
System Requirements:  
Intel Mac OS X 10.5 or newer  
Important Information  
17  
 
 
ENGLISH  
The Polar FT7 training computer applies the following patented technologies, among others:  
®
assessment for determining personal target heart rate limits for the day  
®
coded transmission  
®
personal calorie calculation  
®
technology for heart rate measurement  
®
data transfer  
Limited International Polar Guarantee  
force, or the consumer  
purchased this product in the USA or Canada. This limited Polar international guarantee is issued by Polar  
Electro Oy for consumers who have purchased this product in other countries.  
product will be free from defects in material or workmanship for two (2) years from the date of purchase.  
The receipt of the original purchase is your proof of purchase!  
or non-compliance with the precautions; improper maintenance, commercial use, cracked ,broken or  
scratched cases/displays, elastic strap and Polar apparel.  
consequential or special, arising out of, or related to the product.  
local law.  
Service Centers regardless of the country of purchase.  
Guarantee with respect to any product will be limited to countries where the product has been initially  
marketed.  
©
2010 Polar Electro Oy, FIN-90440 KEMPELE, Finland.  
Polar Electro Oy is a ISO 9001:2008 certified company. All rights reserved. No part of this manual may  
be used or reproduced in any form or by any means without prior written permission of Polar Electro Oy.  
The names and logos marked with a  
trademarks of Polar Electro Oy. The names and logos marked with a ® symbol in this user manual or in  
the package of this product are registered trademarks of Polar Electro Oy, except that Windows is a  
trademark of Microsoft Corporation.  
Disclaimer  
change without prior notice, due to the manufacturer  
with respect to the products described herein.  
indirect or incidental, consequential or special, arising out of, or related to the use of this material or the  
products described herein.  
This product is protected by the incorporeal rights of Polar Electro Oy as defined by the following  
documents: FI115084, US7418237, EP1543769, FI110915, US7324841, EP1361819, FI23471,  
EU00046107-0001, USD492783S, USD492784S, USD492999S, FI96380, JP3568954, US5611346,  
EP665947, DE69414362, FI6815, EP1245184, US7076291, HK1048426, FI 114202, US 6537227,  
EP1147790, HK1040065, DE60128746.0, FI 115289, EP 1127544, US 6540686, HK 1041188, FI  
88972, DE4223657.6 A, FI 9219139.8, FR 92.09150, GB 2258587, HK 306/1996, SG 9592117-7,  
US 5486818, FI111215, EP0747003, US5690119. Other patents pending.  
Manufactured by Polar Electro Oy, Professorintie 5, FIN-90440 KEMPELE, Tel +358 8 5202 100, Fax  
18  
Important Information  
 
   
ENGLISH  
This product is compliant with Directive 93/42/EEC. The relevant Declaration of Conformity is available at  
This crossed out wheeled bin marking shows that Polar products are electronic devices and are in the  
scope of Directive 2002/96/EC of the European Parliament and of the Council on waste electrical and  
electronic equipment (WEEE) and batteries and accumulators used in products are in the scope of  
Directive 2006/66/EC of the European Parliament and of the Council of 6 September 2006 on batteries  
and accumulators and waste batteries and accumulators. These products and batteries/accumulators  
inside Polar products should thus be disposed of separately in EU countries. Polar encourages you to  
minimize possible effects of waste on the environment and human health also outside the European Union  
by following local waste disposal regulations and, where possible, utilize separate collection of electronic  
devices for products, and battery and accumulator collection for batteries and accumulators.  
This marking shows that the product is protected against electric shocks.  
17938084.02 ENG C  
12/2010  
Important Information  
19  
 

Philips CRT Television TP3697B1 User Manual
Philips Handheld TV 15PT1767 User Manual
Philips Headphones DC156 37 User Manual
Philips Portable DVD Player PET716 93 User Manual
Philips Stereo System DC912 User Manual
Philips TV DVD Combo 20DV6942 User Manual
Philips Work Light P 5759 D User Manual
Pioneer Speaker DEH P580MP User Manual
Poulan Blower 545137223 User Manual
PYLE Audio Car Stereo System PLDVD65IN User Manual