120VAC, 60Hz  
INSTAllATION INSTRUCTIONS  
DI-000-RZCZ4-00A-X1  
WARNINGS AND CAUTIONS:  
WARNINGS AND CAUTIONS:  
ON/OFF LED for remote load control.  
Can call up four (4) zone ON/OFF with advanced Programmer/Remote (see RZCPG).  
To be installed and/or used in accordance with appropriate electrical codes and regulations.  
If you are unsure about any part of these instructions, consult a qualified electrician.  
Vizia™ RF RZCZ4 remote does not control the load, but provides scene applications to operate with ViziaTM RF switches.  
Recommended minimum wall box depth is 2-1/2".  
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.  
Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.  
Wiring Application:  
INSTAllING YOUR 4-ZONE CONTROllER  
Step 4  
Step 6 cont'd  
INTRODUCTION  
4-Zone Controlller  
B) If using RZCPG Programmer/Remote, you will be prompted to place  
Leviton’s ViziaTM RF components are designed to communicate with  
each other via Radio Frequency (RF) to provide remote control of your  
lighting. Using RF technology allows Leviton to provide the greatest  
signal integrity possible. Each module in Leviton’s ViziaTM RF component  
line is a Z-WaveTM enabled device. In a Z-WaveTM network, each device  
is designed to act as a router. These routers will re-transmit the RF signal  
from one device to another until the intended device is reached. This  
ensures that the signal is received by its intended device by routing the  
signal around obstacles and radio dead spots. The 4-Zone Controller  
is compatible with any Z-Wave™ enabled network, regardless of the  
manufacturer and can also be used with other devices displaying the  
Z-Wave™ logo.  
NOTE: Use check boxes  
when Steps are completed.  
4-Zone controller into programming mode.  
WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN  
OFF POWER at circuit breaker or fuse and test that power is off  
before wiring!  
Step 1  
C) To access Program mode, press and hold the  
left side of buttons 1 and 3 (refer to figure).  
Wait 5 seconds until the LED turns Amber.  
Release the button and the LED will blink  
Amber. You are now in Programming mode.  
NOTE: If the LED on the 4-Zone controller  
turns solid Red while including, there has  
been a communication error.  
D) While standing close to the 4-Zone controller  
(approximately 2-5 ft.), press the center button  
on the Programmer/Remote to <Include>  
device in the network. NOTE: Only one device  
may be included at any time.  
Hot (Black)  
WH  
BK  
Green  
Ground  
Line  
120VAC, 60Hz  
/&&  
/&&  
/&&  
/&&  
/&&  
/&&  
/. /&&  
/. /&&  
/. /&&  
. /&&  
/&&  
/.  
/.  
/.  
/.  
/.  
/.  
Neutral (White)  
WIRING SWITCH:  
Connect wires per WIRING DIAGRAM as follows:  
Green or bare copper wire in wall box to Green terminal screw.  
Line Hot wall box wire to terminal screw marked "BK".  
Line Neutral wall box wire to terminal screw marked "WH".  
FEATURES  
Identifying your wiring application (most common):  
NOTE: If the wiring in your wall box does not resemble this  
Step 2  
This is a Z-Wave™ Controller  
E) The Primary Programmer/Remote will assign  
a Home ID, Node ID, and Name for this  
device.  
configuration, consult a qualified electrician.  
Zone/Area control without traveler wires  
Can control ON/OFF dim/bright for up to 4 Zones/Area.  
ON/OFF LED  
Testing your 4-Zone Controller prior to mounting  
Step 5  
1. Line (Hot)  
2. Neutral  
3. Ground  
NOTE: This information will be stored in the Programmer/Remote to  
be used for future reference.  
NOTE: You may name or edit the node of this device at this time.  
in wall box:  
Position all wires to provide room in  
outlet wall box for device.  
Ensure that the word “TOP” is facing up  
on device strap.  
Partially screw in mounting screws in  
wall box mounting holes.  
Two way communication  
2
1
3
F) The 4-Zone controller is now installed in the network.  
RF reliability  
G) After all devices are included into the network, the controller must  
be updated to allow proper network function. To update controller  
proceed as follows:  
Ease of installation – No new wiring  
Compatible with other Z-Wave™ enabled devices  
If using a non-Leviton Programmer/Remote, refer to the  
Programmer/Remote instruction sheet for updating controller.  
If using Leviton Z-WaveTM Programmer/Remote, Cat. No. RZCPG,  
press the Menu button and scroll down to System Setup. Press  
the center button to select System Setup Menu. Press the center  
button to select Network. Press the center button to select Update  
"cntrl". When prompted, press desired button on 4-Zone controller.  
Wait until the RZCPG Programmer/Remote confirms completion.  
Update is done.  
NOTE: Dress wires with a bend as  
shown in diagram in order to relieve  
stress when mounting device.  
Tools needed to install your 4-Zone Controller:  
Preparing and connecting wires:  
Step 3  
This 4-Zone controller can be wired using side wire terminal  
screws or through backwire openings. Choose appropriate wire  
stripping specifications accordingly.  
Slotted/Phillips Screwdriver  
Pencil  
Electrical Tape  
Cutters  
Pliers  
Ruler  
Changing the color of your 4-Zone Controller:  
Your 4-Zone controller includes three color options. The controller ships  
with the White frame attached. To change color of frame, proceed as  
follows:  
Restore power at circuit breaker or fuse.  
LED should turn ON, when any button is pressed. If lED does not turn  
ON, refer to the TROUBlESHOOTING section.  
5/8"  
NOTE: If the 4-Zone controller has been  
successfully Included in the network and  
the user tries to Include it again without first  
excluding it from the network, the controller  
will retain the first node ID it had received and  
ignore the second.  
Strip Gage  
(1.6 cm)  
(measure bare  
wire here)  
Cut  
(if necessary)  
Including 4-Zone Controller into Z-WaveTM  
Network:  
Step 6  
Menu  
Button  
Push in  
NOTES:  
line up tabs  
and press in  
side to attach  
side at tab  
to release  
If using a non-Leviton Programmer/Remote, refer to the Programmer/  
Remote instruction sheet.  
Center  
Button  
1
2
3
4
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
4-Zone controllers incuded into a Z-WaveTM network must be updated  
after you have included all other devices.  
After frame is removed, remove existing push buttons by pressing out  
buttons from back of frame and replace them with desired color change  
push buttons by pressing in from front of frame. To make IR capable, use  
new DIM/BRIGHT button with IR window.  
Side Wire Connection  
Side wire terminals accept  
#14 AWG solid wire copper only.  
Back Wire (either hole may be used)  
Back wire openings use #14-12 AWG  
solid wire copper only.  
A) If using a Leviton Z-WaveTM Programmer/Remote, Cat. No. RZCPG,  
press the Menu button and scroll down to System Setup. Press the  
center button to select System Setup Menu. Press the center button to  
select Network. Press the center button to <Include Node>.  
Make sure that the ends of the wires from the wall box are  
straight (cut if necessary).  
Programmer/Remote  
Cat. No. RZCPG  
 

Leica Model Vehicle 1000Z01 User Manual
Lenovo Computer Hardware 3425 User Manual
Liebherr Refrigerator 7080 359 02 User Manual
Lightolier Indoor Furnishings 100IFIC User Manual
Logitech Mouse 1100R User Manual
Lumex Syatems Wheelchair LX1000 User Manual
Makita Cordless Saw 5630DWA User Manual
Master Lock Electric Heater B350EAI User Manual
McIntosh Stereo Amplifier C2300 User Manual
Memorex VCR VX3038 User Manual