Hunter Fan Humidifier 41574 01 User Manual

®
The Care Free  
Humidifier Plus  
Evaporative Humidifier  
Features (Vary By Model):  
NiteGlo™ Night Light  
Digital Humidistat  
Automatic Shut-Off  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
HUNTER FAN CO.  
41574-01 10/14/2002  
1
• No White Dust – The Care Free® Humidi-  
fier Plus Evaporative Humidifier produces  
no white dust that can settle on furniture  
or be inhaled.  
PermaWick™ filter. This is normal and  
does not affect performance. If you  
would like to clean these deposits away,  
please see CLEANING THE HUMIDIFIER  
AND WATER TANK.  
NOTE: You may notice mineral deposits  
accumulating in the tank base or on the  
Humidifier Parts  
Easy Tote Handle  
Water Tank  
Filter Frame  
Hooks  
Humidistat Display  
and Controls  
Push  
Lift Up  
Power/  
Speed  
Control  
Tank Cap  
Main Housing  
PermaWick™ Filter  
PermaWick™  
Filter Frame  
Base  
Insert Guides  
Into Base  
Figure 1  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
HUNTER FAN CO.  
41574-01 10/14/2002  
3
Humidifier Features  
For Models 33205, 33255, 33285, 34335, 37205 & 37255  
Power/Speed Control: Turns the humidifier  
‘ON’ and ‘OFF’. The power should always be  
off before unplugging the humidifier, moving  
the humidifier, or refilling the water tank.  
Humidistat  
Power Light: The red light will be illuminated  
Light  
when the power is on and the humidistat light  
is on.  
Power  
Light  
Humidistat  
Display  
and  
Humidistat Display and Controls: Enables you  
to set desired maximum humidity level. Once  
this level is exceeded, the unit will shut off until  
the humidity level drops.  
Power/  
Speed  
Control  
Controls  
Note: The humidifier may not be running  
because the humidistat setting may need to  
be adjusted.  
Figure 2  
Humidistat Light: The green light will go off  
when the humidity in the room exceeds the  
level that you selected with the digital  
humidistat.  
For Models 33207, 33257, 33287, 34337, 37207 & 37257  
Power/Speed Control: Turns the humidifier  
‘ON’ and ‘OFF’. The power should always be  
off before unplugging the humidifier, moving  
the humidifier, or refilling the water tank.  
Humidistat  
Light  
Power Light: The red light will be illuminated  
when the power is on and the humidistat light  
is on.  
Power  
Light  
Humidistat  
Display  
and  
Humidistat Display and Controls: Enables you  
to set desired maximum humidity level. Once  
this level is exceeded, the unit will shut off until  
the humidity level drops.  
Power/  
Speed  
Control  
Controls  
NiteGlo™  
Night  
Light  
Note: The humidifier may not be running  
because the humidistat setting may need to  
be adjusted.  
Figure 3  
Control  
Humidistat Light: The green light will go off  
when the humidity in the room exceeds the  
level that you selected with the digital  
humidistat.  
NiteGlo™ Night Light Control: Turns the  
night light ‘ON’ and ‘OFF’. The night light can  
be turned on even if the humidifier fan is turned  
off.  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
41574-01 10/14/2002  
4
HUNTER FAN CO.  
For Models 34305, 34355, 37305 & 37355  
Power/Speed Control: Turns the humidifier  
‘ON’ and ‘OFF’. The power should always be  
off before unplugging the humidifier, moving  
the humidifier, or refilling the water tank.  
Refill Light: The red light will be illuminated Humidistat  
Light  
to signal you that the humidifier has  
automatically turned off and the water tank  
needs to be refilled.  
Refill  
Light  
Humidistat  
Display  
and  
Controls  
Power/  
Speed  
Control  
Humidistat Display and Controls: Enables you  
to set desired maximum humidity level. Once  
this level is exceeded, the unit will shut off until  
the humidity level drops.  
Note: The humidifier may not be running  
because the humidistat setting may need to  
be adjusted.  
Figure 4  
Humidistat Light: The green light will go off  
when the humidity in the room exceeds the  
level that you selected with the digital  
humidistat.  
For Models 34307, 34357, 37307 & 37357  
Power/Speed Control: Turns the humidifier  
‘ON’ and ‘OFF’. The power should always be  
off before unplugging the humidifier, moving  
the humidifier, or refilling the water tank.  
Humidistat  
Light  
Refill Light: The red light will be illuminated  
to signal you that the humidifier has  
automatically turned off and the water tank  
needs to be refilled.  
Refill  
Light  
Power/  
Speed  
Control  
Humidistat  
Display  
and  
Humidistat Display and Controls: Enables you  
to set desired maximum humidity level. Once  
this level is exceeded, the unit will shut off until  
the humidity level drops.  
Controls  
NiteGlo™  
Night  
Light  
Control  
Note: The humidifier may not be running  
because the humidistat setting may need to  
be adjusted.  
Figure 5  
Humidistat Light: The green light will go off  
when the humidity in the room exceeds the  
level that you selected with the digital  
humidistat.  
NiteGlo™ Night Light Control: Turns the  
night light ‘ON’ and ‘OFF’. The night light can  
be turned on even if the humidifier fan is turned  
off.  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
41574-01 10/14/2002  
5
HUNTER FAN CO.  
Using Your Humidifier  
1. Remove The Care Free® Humidifier Plus  
Only for models with Automatic Shut-off  
Evaporative Humidifier from its packaging.  
Read and Save the Instructions.  
9. When the water tank is empty, the humidi-  
fier will automatically shut itself off. The  
red light will be illuminated, indicating that  
the water tank needs to be refilled.  
2. Place the humidifier on a hard, flat, water  
resistant surface. Always place the humidi-  
fier at least six (6) inches away from walls and  
sources of heat.  
10. Follow REFILLING THE WATER TANK di-  
rections. Once the water tank is refilled,  
the Refill Light will not be illuminated.  
3. Lift the main housing to confirm that the  
PermaWick™ filters are placed upright in the  
slots. Replace the main housing. (See Figure 1.)  
Only for models with a NiteGlo™ Night Light  
11. Use the control to turn the night light off  
and on. The night light can be operated  
even if the humidifier fan is turned ‘OFF’.  
4. Remove the water tank and take it to the  
sink or tub to fill.  
5. Turn the tank upside down and unscrew the  
tank cap by turning it counterclockwise. Fill  
the water tank with cool water and replace  
the tank cap (Never use hot water). Be sure  
not to overfill the tank as water damage may  
occur to furniture or flooring due to spillage.  
HUNTERWILLNOTACCEPTRESPONSIBILITYFOR  
DAMAGE TO PROPERTY CAUSED BY WATER  
SPILLAGE.  
6. Carry the tank back to the humidifier. Turn  
the tank upright and place it on the humidi-  
fier. Be sure that the tank is seated properly  
in the base. If the tank is properly located on  
the base, you will see air bubbles flowing up  
into the tank.  
7. With the power control knob in the ‘OFF’ po-  
sition, plug the humidifier into the wall.  
CAUTION: Never plug in the Humidifier  
while your hands are wet as Electric Shock  
could occur.  
8. Use the power/speed control knob to  
turn the humidifier ‘ON’ by selecting a  
speed setting.  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
HUNTER FAN CO.  
41574-01 10/14/2002  
6
Using Your Digital Humidistat  
Setting the Desired Humidity  
Setting the Span  
Note: After unplugging the humidifier to Refer to Figure 7.  
move the humidifier, to refill the water tank or  
to clean the humidifier, you must reset the  
digital humidistat.  
Your humidistat is set at the factory to cycle at  
setting 2. If you find your system cycling too  
fast or too slow, then the Span can be adjusted  
to modify the cycle time.  
Refer to Figure 6.  
1. Use the power/speed control knob to  
turn the humidifier ‘ON’ by selecting a  
speed setting.  
4. Press and hold both humidistat control  
buttons for two seconds to enter span set-  
ting mode.  
Note: A speed setting must be chosen  
before the humidistat will operate the hu-  
midifier.  
5. In span mode, use the humidistat control  
buttons to adjust the span. Raise the span  
to 3 to increase the cycle time and allow  
your system to run longer. Lower the span  
to 1 to decrease the cycle time and allow  
your system to run shorter.  
2. In normal mode use the humidistat con-  
trol buttons to set the desired humidity  
level. The settings range from 30% to 80%  
in 5% increments.  
6. The humidistat display will return to nor-  
mal mode after keys are idle for 5 seconds.  
3. When the humidity exceeds the level you  
have set, the humidistat light will go off.  
The humidifier will not output humidity  
while the humidity in the room is at the  
selected humidity level. The humidistat  
light will stay off until the humidity  
changes. When the humidity in the room  
drops below the selected level, the humidi-  
fier will cycle on again and the humidistat  
light will come on.  
Humidistat  
Light  
Humidistat Control  
Buttons  
Figure 7  
Humidistat Control  
Buttons  
Figure 6  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
41574-01 10/14/2002  
7
HUNTER FAN CO.  
Refilling The Water Tank  
1. When the water tank level is low, turn the  
HUNTER WILL NOT ACCEPT RESPONSIBIL-  
ITY FOR DAMAGE TO PROPERTY CAUSED  
BY WATER SPILLAGE.  
humidifier ‘OFF’, and unplug.  
2. Remove the tank and take it to the sink or  
tub to refill.  
4. Carry the tank back to the humidifier. Turn  
the tank upright and place it on the hu-  
midifier. Be sure that the tank is seated  
properly in the base. If the tank is properly  
located on the base, you will see air bubbles  
flowing up into the tank.  
3. Turn the tank upside down and unscrew the  
tank cap by turning it counterclockwise.  
Empty the tank, refill with fresh cool water  
(never use hot water), and replace the tank  
cap. Be sure not to overfill the tank as water  
damage may occur to furniture or flooring  
due to spillage.  
Cleaning The Humidifier And The Water Tank  
in a location where it can drip dry while  
you clean the other parts of your humidifier.  
Many regions have hard water with high  
concentrations of minerals. When water  
evaporates from The Care Free® Humidifier Plus  
Evaporative Humidifier, minerals may be left  
behind. These minerals can form a hard white  
scale which can be removed by following the  
cleaning instructions. The frequency of  
cleaning due to mineral build up can vary  
depending upon the quality of water you  
may have.  
5. Remove the water tank from the base and  
empty any water that is left in the tank.  
Soak the base in a mixture of one (1) gal-  
lon of water and eight (8) ounces of vin-  
egar for 20 minutes.  
6. After soaking, wipe the base with a soft  
cloth or sponge to remove any mineral  
build up. Rinse with clean water several  
times. If you are planning on storing the  
humidifier, be sure the base is com-  
pletely dry.  
Refer to Figure 1 for part names.  
1. Turn the humidifier ‘OFF’ and unplug the  
unit.  
2. Lift the main housing and remove the wa-  
ter dispersion tray and the PermaWick™  
Filters. The motor is attached to the main  
housing. Do not place the motor near  
water. Do not use a wet towel on the  
motor or motor housing as electrical  
shock may occur.  
7. Fill the water tank with one (1) gallon of  
water and eight ounces of undiluted white  
vinegar. Replace the tank cap and shake  
the tank vigorously until all interior sur-  
faces of the tank have been exposed to the  
water/vinegar mixture.  
8. Empty the tank of the water/vinegar mix-  
ture. Rinse it several times with clean water  
and then replace the tank cap. If you are  
planning on storing the humidifier, dry it  
inside and out, leaving the cap off to allow  
the tank to completely dry. Continue to  
clean the other parts of your humidifier.  
3. The PermaWick™ Filter should be cleaned  
in a vinegar and water solution to remove  
any mineral buildup. Place in a solution of  
one (1) gallon of water and eight (8) ounces  
of undiluted white vinegar. Allow the filter  
to soak for 20 minutes.  
4. After soaking, rinse it several times with  
clean water. Place the PermaWick™ Filter  
9. Remove the water diffuser cap and sponge.  
Rinse the sponge in clean water to remove  
any debris. If the sponge contains hard  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
HUNTER FAN CO.  
41574-01 10/14/2002  
8
water residue, soak it in a mixture of 11. Once all the parts are clean, reas-  
one (1) gallon of water and eight (8)  
ounces of vinegar for 20 minutes. Rinse  
well and reinstall sponge and diffuser cap  
in unit. Do not expose motor or other  
electrical components to water.  
semble the humidifier, and follow the  
USING YOUR HUMIDIFIER to con-  
tinue use. If you are storing the hu-  
midifier, make sure the parts are  
completely dry, reassemble, and  
store in a dry location.  
10. Wipe the surfaces of the main housing with  
a soft cloth.  
Service Parts  
To obtain a service part for your humidifier, call customer service at 1-888-830-1326 or e-mail us  
at Te[email protected]. Please be prepared to tell the operator the model number of  
your humidifier and the name of the part you need to replace and the part number. Refer to  
Figure 1 for part names.  
Filter  
Frame  
Water  
Tank  
Power/Speed  
Control  
Tank  
Cap  
Perma wick  
Filter  
Model No.  
Base  
33205  
33207  
33255  
33257  
33285  
33287  
34305  
34307  
34335  
34337  
34355  
34357  
37205  
37207  
37255  
37257  
37305  
37307  
37355  
37357  
64171-01-000  
64171-01-001  
92849-01-325 92851-01-326  
74080  
74082  
64171-03-000 92850-01-325 92852-01-326  
64101-01-325 74079-01-325  
64171-01-000  
92849-01-325 92851-01-326  
67171-01-001  
74080  
74082  
64171-03-000 92850-01-325 92852-01-326  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
41574-01 10/14/2002  
9
HUNTER FAN CO.  
Hunter Fan Company  
The Care Free® Humidifier Plus Evaporative Humidifier  
5 YEAR LIMITED WARRANTY  
The Hunter Fan Company, Inc. makes the NO WARRANTY, EXPRESSED OR IM-  
following warranty to the original residen- PLIED, INCLUDINGANYWARRANTYOF  
tial user or consumer purchaser of The Care MERCHANTABILITYOR FITNESS FORA  
Free® Humidifier Plus Evaporative Humidi- PARTICULAR PURPOSE, IS MADE IN RE-  
fier:  
SPECT TO THE FILTER.  
If any part of The Care Free® Humidifier Plus THIS WARRANTY IS IN LIEU OF ALL  
Evaporative Humidifier (“Humidifier”) mo- OTHER EXPRESSWARRANTIES. THE DU-  
tor fails during the first 5 (five) years from the RATION OF ANY IMPLIED WARRANTY,  
date of installation due to a defect in mate- INCLUDING BUT NOT LIMITED TOANY  
rial or workmanship, we will provide a re- IMPLIED WARRANTY OF MERCHANT-  
placement part free of charge. If no replace- ABILITYOR FITNESS FORAPARTICULAR  
ment part can be provided for such motor, we PURPOSE, IN RESPECT TO THE MOTOR  
will replace your humidifier.  
IS EXPRESSLYLIMITED TO THE PERIOD  
OF THE EXPRESS WARRANTY SET  
FORTHABOVE.  
If your Humidifier motor fails any time  
within 1 (one) year after the date of instal-  
lation due to a defect in material or work- This warranty is voided if your Humidi-  
manship, labor to repair the defect will be fier is not purchased and used in the USA  
provided free of charge at our nearest ser- or Canada.  
vice centre or at our Service Department in  
This warranty excludes and does not cover  
Memphis, Tennessee. You will be respon-  
defects, malfunctions, or failures of the Hu-  
sible for all parts and labor costs after this  
midifier which were caused by repairs by per-  
one-year period.  
sons not authorized by us, use of parts, or  
If your Humidifier water tank, filter fame, base, accessories not authorized by us, mishan-  
knobs, or tank cap fail any time within 1 (one) dling, modifications, or damage to the Hu-  
year after the date of sale to you due to a midifier while in your possession, or unrea-  
defect in material or workmanship, we will sonable use, including failure to provide rea-  
repair or, at our option, replace the water tank, sonable and necessary maintenance. This  
filter frame, base, knobs, or tank cap free of warranty does not cover humidifiers used in  
charge for parts or labor performed at our near- commercial applications. There are no express  
est service centre or our Service Department or implied warranties as to commercial pur-  
in Memphis, Tennessee.  
chasers or users.  
IF THE ORIGINAL RESIDENTIAL USER OR To obtain service, contact the nearest Hunter  
CONSUMER PURCHASER CEASES TO authorized service centre or the Hunter Fan  
OWNTHE HUMIDIFIER, THISWARRANTY Company Service Department, 2500 Frisco  
ANDANY IMPLIED WARRANTYWHICH Avenue, Memphis, Tennessee 38114, 901-  
THEN REMAINS IN EFFECT, INCLUDING 248-2222. You will be responsible for insur-  
BUT NOT LIMITED TO ANY IMPLIED ance and freight or other transportation to  
WARRANTY OF MERCHANTABILITYOR our factory service center. We will return the  
FITNESS FORAPARTICULAR PURPOSE, Humidifier freight prepaid to you. The Hu-  
AREVOIDED.  
midifier should be properly packaged to  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
10 HUNTER FAN CO.  
41574-01 10/14/2002  
avoid damage in transit since we will not be  
responsible for any such damage. Proof of  
purchase is required when requesting war-  
ranty service. The purchaser must present the  
sales receipt or other document that estab-  
lishes proof of purchase.  
• THE LIMITATION OF THE REM-  
EDIES AND RECOURSES AVAIL-  
ABLE TO THE PURCHASER; OR  
• THE INVALIDITY OF AN EXPRESS  
WARRANTY WHEN A PRODUCT  
IDENTIFIED BY BRAND NAME IS  
NOTUSED (UNLESS SPECIFIC CON-  
DITIONSARE FULFILLED);  
IN NO EVENT SHALLHUNTER FAN COM-  
PANYBE LIABLE FOR DIRECT, INDIRECT,  
SPECIAL, CONSEQUENTIAL OR INCIDEN-  
TAL DAMAGES IN EXCESS OF THE PUR-  
CHASE PRICE OFTHE HUMIDIFIER.YOUR  
SOLE REMEDYWILL BE REPAIR OR RE-  
PLACEMENTAS PROVIDEDABOVE.  
SOTHEABOVE LIMITATIONS OR EXCLU-  
SIONS MAYNOTAPPLYTOYOU.  
THIS WARRANTY GIVES YOU SPECIFIC  
LEGAL RIGHTS AND YOU MAY ALSO  
HAVEOTHERRIGHTSWHICHVARYFROM  
STATETO STATE OR PROVINCE TO PROV-  
INCE.  
SOME AMERICAN STATES AND CANA-  
DIAN PROVINCES DO NOTALLOW  
• LIMITATIONS ON HOW LONG AN  
IMPLIED WARRANTYLASTS;  
• THE EXCLUSION OR LIMITATION  
OF DIRECT, INDIRECT, SPECIAL, IN-  
CIDENTAL OR CONSEQUENTIAL  
DAMAGES;  
• THE EXCLUSION OR INVALIDITY  
OF EXPRESS OR IMPLIEDWARRAN-  
TIES IF THE USER CEASES TO OWN  
THE HUMIDIFIER;  
HUNTER FAN COMPANY  
2500 FRISCO AVENUE  
MEMPHIS, TN 38114, USA  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
11  
41574-01 10/14/2002  
HUNTER FAN CO.  
Other Home Comfort Products from Hunter  
Pre-Fil  
terFilter  
Filter  
Reset  
Hunter Original®  
QuietFlo™  
True HEPA Air  
Purifier  
Programmable  
Thermostat  
To learn more about Hunter Fan Company products, please see our web page at:  
Download from Www.Somanuals.com. All Manuals Search And Downloa©d.2002  
12 HUNTER FAN CO.  
41574-01 10/14/2002  

Graco Yard Vacuum 3000cc User Manual
Grizzly Planer G1037Z User Manual
Haier Dishwasher HDW101WH User Manual
Haier Flat Panel Television 15HL25S User Manual
Haier Washer HM500TX User Manual
Hans Grohe Plumbing Product 06128XX0 User Manual
Harbor Freight Tools Automobile Parts 98480 User Manual
Heatcraft Refrigeration Products Fan BN LOPTB User Manual
HP Hewlett Packard Printer V85 User Manual
Igloo Beverage Dispenser FRW517UK User Manual