MODEL T10006
50 Kg DIGITAL CRANE SCALE
OWNER'S MANUAL
COPYRIGHT © OCTOBER, 2007 BY GRIZZLY INDUSTRIAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#JM9992 PRINTED IN CHINA
Safety Instructions for Crane Scales
8.
ALWAYS DISCONNECT FROM
POWER SOURCE BEFORE
SERVICING. Make sure switch is in
OFF position, charger is unplugged,
and battery disconnected before
servicing.
1.
2.
READ THROUGH THE ENTIRE
MANUAL BEFORE USING. This
crane scale presents serious injury
hazards to untrained users.
NEVER ALLOW UNQUALIFIED
PERSONNEL TO SERVICE THIS
SCALE. Servicing the scale incor-
rectly may reduce the maximum
holding capacity of the load cell or
cause the scale to give incorrect
readings, which may result in over-
loading.
9.
CHECK FOR DAMAGED PARTS
BEFORE USING SCALE. Check
for broken parts, loose bolts,
cracked or worn components and
any other conditions that may
affect machine operation. Repair or
replace damaged parts.
3.
4.
DO NOT LIFT MORE THAN
THE MAXIMUM SUGGESTED
CAPACITY. Be aware that the load
weight, harnesses and load bear-
ing equipment all contribute to the
total load weight. Overloading may
cause the load to fall.
10. USE RECOMMENDED ACCES-
SORIES. Refer to the instruction
manual for recommended acces-
sories. The use of improper acces-
sories may increase risk of injury.
11. NEVER LET LOADS SWING.
Unsteady loads may become unbal-
anced and fall. Swinging motions
cause wear on components and
may cause them to break.
NEVER LIFT HEAVY LOADS
WHEN TIRED, OR UNDER THE
INFLUENCE OF DRUGS OR
ALCOHOL. Be mentally alert at all
times when lifting or moving heavy
loads.
12. USE CORRECT HARNESSES.
Never use oversized or multiple
harnesses.
5.
6.
7.
ONLY ALLOW TRAINED AND
PROPERLY SUPERVISED PER-
SONNEL TO OPERATE SCALE.
Make sure operation instructions
are safe and clearly understood.
13. CHARGE ONLY USING THE
SUPPLIED
CHARGER
AND
BATTERY. Do not use with other
batteries, chargers or scales.
NEVER LEAVE A LOAD WHILE
SUSPENDED. Lower the load to
the ground and un-hook all loads
and harnesses before leaving the
crane scale unattended.
14. DO NOT EXPOSE BATTERY OR
CHARGER TO WET OR RAINY
CONDITIONS. Moisture greatly
increases the risk of a shock haz-
ard.
NEVER SUSPEND THE LOAD
OVER OR NEAR
A
PERSON.
Loads may fall at any given time
due to overloading, improper load-
ing procedures, or failure of a com-
ponent.
15. DO NOT STORE BATTERY WITH
CONDUCTIVEMATERIALS.Storing
the battery in a box of screws or
nails can cause shorting across the
battery poles.
-2-
Model T10006 50 Kg Digital Crane Scale
SECTION 2: INTRODUCTION
Foreword
Contact Info
It is our pleasure to provide this manual
with the Model T10006. It was written to
encourage safety considerations and guide
you through general operating procedures
and maintenance.
If you have any comments regarding this
manual, please contact us:
Grizzly Industrial, Inc.
C/O Technical Documentation Manager
P.O. Box 2069
The specifications, details, and photo-
graphs in this manual represent the Model
T10006 as supplied when the manual was
prepared. However, owing to Grizzly’s pol-
icy of continuous improvement, changes
may be made at any time with no obligation
on the part of Grizzly.
Bellingham, WA 98227-2069
Email: [email protected]
Most importantly, we stand behind our
tools. If you have any service questions or
parts requests, please call or write us at
the location listed below.
Grizzly Industrial, Inc.
1203 Lycoming Mall Circle
Muncy, PA 17756
Machine Data
Phone: (570) 546-9663
Fax: (800) 438-5901
E-Mail: [email protected]
Maximum Capacity............50 Kg (110 lbs.)
Minimum Load.................0.4 Kg (0.88 lbs.)
Crane Battery...........Rechargeable 6V/5Ah
Crane Battery Life..........................50+ hrs.
Crane Battery Adapter.........DC9V/1500mA
Operating Temperature.........-10ºC – 40ºC/
14°F – 104°F
Operating Humidity..................85% or Less
Remote Control Battery..............#5, 1.5Vx2
Digital Display...................5 Digit LCD/LED
Character Display.....................30mm High
Scale Body..........Die-Cast Aluminum Case
Scale Weight ...............................10.35 lbs.
Read the manual before operation.
Become familiar with this scale, its
safety instructions, and its operation
before beginning any work. Serious
personal injury may result if safety or
operational information is not under-
stood or followed.
Model T10006 50 Kg Digital Crane Scale
-3-
SECTION 3: SETUP
Unpacking
Site Consideration
Weight Capacity
Your crane scale was carefully packaged
for safe shipping. If you discover any dam-
age after you have signed for delivery,
immediately call Customer Service at (570)
546-9663 for advice.
The Model T10006 crane scale has a
maximum capacity of 50 Kg (110 lbs.).
When choosing a mounting site, verify that
the hardware and the site can withstand
at least the maximum loading capacity
as well as any possible overloading that
may occur.
Save the containers and all packing materi-
als for possible inspection by the carrier or
its agent. Otherwise, filing a freight claim
can be difficult.
Working Clearances
Consider existing and anticipated needs,
dimensions of your weighing platform, size
of material to be processed, and whether
you need the scale to be mobile or in a
stationary location when establishing an
installation site for your crane scale. For
an accurate reading, there must not be any
items near the scale or weighing platform
that may lean or fall and add weight.
When you are completely satisfied with
the condition of the shipment, you should
inventory the contents.
Inventory
Model T10006 Inventory (Figure 1)
A. Crane Scale ....................................... 1
B. Remote Control.................................. 1
C. Scale Battery Charger ....................... 1
Power Outlets
The Model T10006 crane scale includes a
remote control and scale battery charger.
When establishing a site for your scale,
make sure outlets are located near the
scale so power or extension cords are
clear of high-traffic areas.
A
B
C
Do not place crane scale in areas of high
electrical fields. Electrical fields can pre-
vent scale accuracy.
Figure 1. Model T10006 inventory
No list of safety guidelines is complete, because every work environment is
different. Always consider safety first and use common sense. Failure to use this
tool with caution and respect could result in serious personal injury.
-4-
Model T10006 50 Kg Digital Crane Scale
Loading Hardware
When attaching your crane scale:
13⁄16"
1. DO NOT use multiple chains or har-
nesses. Only one point of contact
should be used on the hook and shack-
le to lessen the chance of the load fall-
ing and to allow proper load alignment.
2 3⁄4
"
2. DO NOT use oversized items or har-
nesses. Oversized items creates mul-
tiple points of contact and will not fit
properly with the crane scale hardware.
Inaccurate readings, uneven, and dan-
gerous loads may result.
3
⁄4"
Refer to Figures 2 & 3 for Model T10006
dimensions.
8 3⁄4
"
Figure 3. Scale side view measurements.
4"
Like all tools there is potential danger
when operating this tool. Accidents
are frequently caused by lack of
familiarity or failure to pay attention.
If normal safety precautions are
overlooked or ignored, serious
personal injury may occur.
����
���
��
��
����
����
To maintain accuracy, the scale
should remain hanging and not be
allowed to rest on the ground for a
significant amount of time.
Figure 2. Scale front view measurements.
Model T10006 50 Kg Digital Crane Scale
-5-
SECTION 4: OPERATIONS
Scale Functions
Hold LED Display
Load Stable LED Display
���
����
Tare LED Display
Zero LED Display
��
��
����
����
ON/OFF Button
Weight in lbs.
Tare Button
Remote Receiver Window
Zero Button
Figure 4. Scale face.
Turning the Scale ON
Tare Function
After your crane scale has been properly
mounted, familiarize yourself with the func-
tions both on the scale and on the remote
control. Begin by holding down the
button on the scale to turn it ON (Figure
4). Each time the scale is turned on, it will
flash a series of displays. Use the table
below to familiarize yourself with the dis-
play and its meanings.
The tare function will allow you to auto-
matically deduct the weight of the weigh-
ing platforms or containers, resulting in a
final weight of only the items that you want
weighed (the net weight). When your scale
is ready, attach your weighing platform to
the lifting hook at the bottom of the scale,
then wait until the "STB" light comes on.
Before placing any items on the platform,
deduct the weight of the platform by press-
F
u
n
c
t
i
o
n
Di
s
p
l
a
y
Action
ing the
button on the scale (Figure 4),
Off/On 8.8.8.8.8 Start up, display twice
110.25 Maximum capacity, display twice
U X.XX Current battery voltage
- - - - - Wait signal
or by pressing Tare on the remote control.
After you have selected the Tare function
for the platform, the scale will return to
0.00 between loads until you turn off the
scale.
0.00 STB light will engage, ready
To guarantee accuracy for your crane
scale, allow it warm up without a load for
3-5 minutes.
Power Saving
If the load is left at stable status, ("STB"
as shown in Figure 4) for longer than 15
minutes, the screen will flash "–" to save
power and will return to normal weighing
readings when the load is changed. If
the load is left at stable status for over 60
minutes, the scale will turn OFF automati-
cally.
Zero Function
Generally, your scale will read the weight
of the hook. To return your scale to zero,
press the
4), or on the
control.
button on the scale (Figure
button on the remote
�
-6-
Model T10006 50 Kg Digital Crane Scale
Overload Warning
Remote Control
Functions
If the load exceeds the maximum capacity
(net + tare weight), -OL- will be displayed
on the screen. DO NOT overload the
scale. Failure to stay below the maximum
load rating may result in injury, damage the
scale, and void your warranty.
Display LED
Turning the Scale OFF
To turn the scale OFF, hold down the
button on the scale or hold down the OFF
button on the remote control.
Zero
Tare
�
����
Note: The scale will not turn off unless it is
at the main weighing screen.
MR
��
M+
��
�����
���
Clear
��
��
F1
Hold
������
Do not use this scale during lighting
and rain storms or other inclement
weather. Turn the scale off, unplug
any charging equipment and remove
the battery.
����
Off
If this scale is used for the selling of
goods, it must be "Legal for Trade"
and calibrated regularly.
Figure 5. Remote control buttons.
Lb/Kg Conversion
The crane scale can display either in
pounds or kilograms. To change between
the measures of weight, press MR button
on the remote and the screen will display
SHIFT. Press HOLD and the screen will
display UN=0 if converting to kilograms,
or UN=1 if converting to pounds. If the
current weight is in pounds, the "lb" light
on the scale will light up. If the current
weight is in kilograms then the "lb" light
will be off.
Model T10006 50 Kg Digital Crane Scale
-7-
Scale Battery
Advance Tare Weight
The scale will automatically display the
current scale battery voltage when you
turn the scale ON and OFF. To check the
voltage during use, press the MR button
on the remote control and the screen will
display SHIFT. Press the F1 button and the
screen will display U X.XX. To return to the
main display, press MR again.
To input a known tare weight before weigh-
ing an item, press MR and the screen
will display SHIFT. Press TARE, and the
screen will display 000.00. To input the
desired weight, scroll to the right by press-
ing the right arrow (TARE) on the remote
control until you come to the number that
you would like to change. To increase
the number from zero, press the left but-
When the battery voltage is lower than
U 5.80, the screen will flash to alert you.
The scale will continue to display for
approximately one minute longer until -Lb-
is displayed on the screen, and then turn
OFF automatically. The scale will need to
be charged before further use.
ton (
) on the remote control. To
�
decrease the number, press CLEAR on
the remote control. When you are satis-
fied with the current number, press the
M+ to move to the left. To submit the tare
amount, press MR and the TARE light will
come on the scale, automatically deduct-
ing the imputed tare weight. The tare
weight will stay the same until the scale is
turned OFF.
To recharge the battery:
1. Turn the scale OFF.
Clear Function
2. Connect the supplied adapter into the
socket located in the back of the scale,
then into a grounded 110V outlet. The
light turns orange while charging and
turns red when charging is complete.
To clear, press the CLEAR button and
the screen will flash CLr. If you would
like to approve the clear command, press
MR and the screen will display 888.88,
confirming the deletion. If you would like
to cancel the clear command, press the
CLEAR button again. The screen will dis-
play noCLr canceling the deletion.
Note: The battery should re-charge for
at least 8 hours.
Hold Function
Search Overload Times
When the load has been added to the
scale, wait until the STB light goes off sig-
nifying that the load is stable (Figure 4). If
you would like the weight value to remain
on the screen, press the HOLD button on
the remote control. To clear the screen,
press the HOLD button again.
To review how many instances the scale
has been overloaded, press the MR button
and the screen will display SHIFT. Press
the CLEAR button and the screen will
display OL=XX, showing how many times
the scale has exceeded its maximum
capacity.
Current Zero Value:
Display Function
The current zero value is the tare weight
that was selected. To view the current
zero scale value, press the MR button and
the screen will display SHIFT. Press the
To change the brightness of the display,
press F1. Display brightness ranges from 1
(minimum light) to 5 (maximum light). The
default display setting is 2.
button on the remote control to
display the current zero value.
�
-8-
Model T10006 50 Kg Digital Crane Scale
Note: The remote control is a generic
remote and may contain buttons that will
not be used with this particular model.
Should you lose the included remote con-
trol, these functions can not be completed.
To obtain a replacement controller from
Grizzly; call 1-800-523-4777.
D
i
s
p
lay
Action
- - - - - Wait signal
Err10 Accumulated weight below capacity
Err11 Accumulated times exceed (30+)
Err12 Accumulated weight exced (999.99)
CLr Delete weight?
noCLr Cancel deletion
88888 Confirm deletion
noACC No accumulated value
SHIFt Weight conversion
Reference Guide
UX.XX Current battery voltage
SCALE Enter weight adjustment
SEtUP Enter parameter adjustment
UAdJ Enter voltage adjustment
-OL- Overload warning
For quick references and questions about
scale displays, use the charts below for
assistance.
-Lb- Low battery warning
End Parameter adjustment ready
OFF Turn off
Function
Button
D
i
s
p
la
y
Action
ON
8.8.8.8.8
110.25
U X.XX
- - - - -
0 Scale is ready for use
OFF
OFF/
U X.XX
OFF
Scale is OFF
Zero
Tare
Hold
0.00
Display reads 0, "Zero" LED is on
Display reads 0, Tare LED is on
Weight is held, press HOLD to exit
TARE/
HOLD
0.00
XXX.XX
Brightness F1
1 through 5 1=lowest, 5=highet setting
Function
Button Display
Button
Action
Lb/Kg Conversion MR
SHIFT
HOLD
UN=O (weight in Kg, "lb" LED is off)
UN=1 (weight in lb, "lb" LED is on)
Battery Voltage
Current Zero Value MR
Advance Tare MR
MR
SHIFT
F1
U X.XX, press MR to exit
SHIFT
SHIFT
/
XXX.XX Current zero value
TARE to scroll right
�
TARE/
to increase number
CLEAR to decrease number
M+ to submit and scroll left
�
MR to submit total, "TARE" LED is on
Overload Review MR
Clear
SHIFT
CLEAR
OL=XX (Overload= XX times)
CLEAR CLR
MR
CLEAR
888.88 = confimation of clear
noCLR = cancel clear
Model T10006 50 Kg Digital Crane Scale
-9-
SECTION 5: MAINTENANCE
If the scale becomes dirty, clean the
General
screen with a soft cloth using a mild win-
dow cleaner or detergent. Avoid using
paper towels. DO NOT use solvents,
Regularly check mounting hardware for
chemicals or other corrosive materials to
cracks, unsafe wear, deformation, or
clean the scale.
warping. DO NOT attempt to fix these
items! Discard and replace all damaged
If the scale will not be used for a prolonged
hardware. Regularly check for loose pins,
amount of time, remove the battery. Hang
rings, screws, and safety latches. Tighten
the scale at all times and do not allow it to
or replace any loose items. Damaged or
rest on the ground.
loose parts may cause the load to fall and
may result in serious injury.
Always keep the scale in a hanging posi-
tion to relieve strain on the load cell. Never
leave a load or weighing equipment on the
scale when not in use. This may cause
excessive strain on the precision weighing
device and may result in inaccurate read-
ings and shorten the life of your scale.
!
When re-charging the scale battery, charge
for at least 8 hours. Excessive charging
will not damage the battery. Batteries must
be recycled or disposed of properly.
Always DISCONNECT POWER before
servicing, adjusting, or doing main-
tenance to reduce the risk of acci-
dental injury or electrocution.
If your scale malfunctions permanently,
do not attempt to fix it yourself. Contact a
certified professional for any electrical or
detailed calibration work.
BATTERY MUST BE RECYCLED OR DISPOSED
OF PROPERLY. Consult your local disposal com-
pany for recycling options in your area.
-10-
Model T10006 50 Kg Digital Crane Scale
SECTION 6: SERVICE
Troubleshooting
Symptom
Possible Cause
Solution
No display when
the scale is turned
ON.
1. Battery is dead or damaged.
1. Check and charge or
replace battery.
2. Tighten the battery contact.
2. Battery contact is loose.
1. Low battery.
Display flashes.
1. Recharge battery.
Scale will not turn
ON or OFF.
1. ON/OFF button is damaged.
1. Check and clean the button
and button contact.
2. Scale is still in function mode. 2. Exit out of the function to
the main screen, then turn
OFF the scale.
Display will not
show a stable
weight.
1. The load is unstable.
2. Load cell cable is damaged.
1. Stabilize the load.
2. Check and replace load
cell.
3. The scale has been in a damp 3. Put the scale in a dry envi-
environment for a prolonged
amount of time.
ronment.
Recharge indicator 1. Damaged adaptor.
light will not turn
1. Check or replace the adap-
tor.
ON.
2. The adaptor is not fully
plugged into the scale or out-
let.
2. Insert the plug again.
Scale unable to
tare.
1. Damaged TARE button.
1. Check and clean the button
and button contact.
Large weight error. 1. Scale is not hung properly.
1. Check the scale, har-
nesses, etc. Review Setup
section on Page 4.
Battery unable to
charge.
1. Battery is damaged.
2. Outlet is damaged.
1. Replace the battery.
2. Replace the outlet.
Remote will not
work.
1. Remote control is too far away 1. Move the remote closer to
from the scale
the scale.
2. Dirty receiver window.
3. Remote control batteries are
low.
2. Check and clean window.
3. Replace controller batter-
ies.
The display will not 1. The scale has not had enough 1. Allow the scale to warm up
show "0" with an
empty load.
time to warm up.
for 3-5 minutes after turning
it on.
2. The scale has been placed on 2. Hang the scale.
the ground and not hung for a
prolonged time.
Model T10006 50 Kg Digital Crane Scale
-11-
T10006 Parts Breakdown
�
�� ��
�
��
��
�
��
��
��
�
�
�
�
��
��
��
��
��
��
��
��
��
��
����
����
�
�
��
����
����
��
��
REF PART #
DESCRIPTION
REF PART #
18 PFH07M
DESCRIPTION
FLAT HD SCR M5-.8 X 10
1
2
3
4
5
6
7
8
9
PT10006001 SCALE BATTERY 6V
PT10006002 BRACKET
19 PT10006019 LOAD CELL ASSEMBLY
20 PT10006020 CIRCUIT BOARD
PW07M
PLW09M
PS79M
FLAT WASHER 3MM
LOCK WASHER 3MM
21 PT10006021 LONG BOW SHACKLE ASSEMBLY
22 PT10006022 TWO WIRE ASSEMBLY
PHLP HD SCR M3-.5 X 8
PT10006006 BACK PANEL
PT10006007 BACK PANEL WIRE ASSEMBLY
23 PS111M
PHLP HD SCR M3-.5 X 4
24 PT10006024 THREE WIRE ASSEMBLY
PLW09M
PS79M
LOCK WASHER 3MM
25 PT10006025 GRVD HDLESS CLEVIS PIN 12 X 40
PHLP HD SCR M3-.5 X 8
26 PW06M
27 PR48M
FLAT WASHER 12MM
10 PT10006010 SPACER
EXT RETAINING RING 11MM
11 PN07M
12 PS55M
13 PSB39M
HEX NUT M3-.5
28 PT10006028 HOOK ASSEMBLY
28-1 PT10006028-1 HOOK
PHLP HD SCR M3-.5 X 10
CAP SCREW M4-.7 X 20
28-2 PS98M
PHLP HD SCR M3-.5 X 16
14 PT10006014 REMOTE CONTROL
28-3 PT10006028-3 SAFTEY LATCH
15 PT10006015 LOAD CELL WIRE ASSEMBLY
28-4 PLN13M
LOCK NUT M3-.5
16 PS79M
PHLP HD SCR M3-.5 X 8
32 PT10006032 BATTERY CHARGER
17 PT10006017 FRONT PANEL
-12-
Model T10006 50 Kg Digital Crane Scale
WARRANTY
Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original
purchaser from the date of purchase. This warranty does not apply to defects due directly or
indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of mainte-
nance. This is Grizzly’s sole written warranty and any and all warranties that may be implied
by law, including any merchantability or fitness, for any particular purpose, are hereby limited
to the duration of this written warranty. We do not warrant or represent that the merchandise
complies with the provisions of any law or acts unless the manufacturer so warrants. In no
event shall Grizzly’s liability under this warranty exceed the purchase price paid for the prod-
uct and any legal actions brought against Grizzly shall be tried in the State of Washington,
County of Whatcom.
We shall in no event be liable for death, injuries to persons or property or for incidental,
contingent, special, or consequential damages arising from the use of our products.
To take advantage of this warranty, contact us by mail or phone and give us all the details.
We will then issue you a “Return Authorization Number,” which must be clearly posted on
the outside as well as the inside of the carton. We will not accept any item back without this
number. Proof of purchase must accompany the merchandise.
The manufacturers reserve the right to change specifications at any time because they
constantly strive to achieve better quality equipment. We make every effort to ensure that
our products meet high quality and durability standards and we hope you never need to use
this warranty.
Please feel free to write or call us if you have any questions about the machine or the
manual.
Grizzly Industrial, Inc.
1203 Lycoming Mall Circle
Muncy, PA 17756
Phone: (570) 546-9663
Fax: (800) 438-5901
E-Mail:
Thank you again for your business and continued support. We hope to serve you again
soon!
|