Grandstream Networks Telephone Accessories HT286 User Manual |
BroadSoft Partner Configuration Guide
Grandstream HT286/386/486/488/496
Analog Telephone Adapter
&
BT100 SIP Phone
October 2007
Document Version 1.2
Document Revision History
Version
1.1
Reason for Change
Introduced document for HT496 version 1.0.3.96 validation with BroadWorks R14.SP2
Added HT286/386/486/488/BT-100 models.
1.2
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 3 OF 23
Table of Contents
BroadWorks Validation Package Support Level.......................................................................6
3.2 Interoperability Issues...................................................................................................................9
BroadWorks Device Type...........................................................................................................12
6.1 System Level Configuration...................................................................................................... 14
6.2 Subscriber Level Configuration Parameters............................................................................ 15
Enhanced IP Phone Configuration............................................................................................16
Appendix B: BroadWorks Validation Package Test Items ............................................................21
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 4 OF 23
1
Overview
This document describes the configuration procedures required for a Grandstream HT-
286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 to make full use of the capabilities of
BroadWorks.
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 is one of the many access
devices that interoperate with BroadWorks.
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 uses the Session Initiation
Protocol (SIP) to communicate with BroadWorks for call control. It also translates voice to
audio packets for transmission across a packet network.
This guide describes the specific configuration items that are important for use with
BroadWorks. It does not describe the purpose and use of all configuration items on the
HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100. For those details, see the HT-286
/ HT-386 / HT-486 / HT-488 / HT-496 / BT-100 User Manual supplied by Grandstream
Error! Reference source not found..
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 5 OF 23
2
BroadWorks Validation Package Support Level
Devices are validated according to BroadWorks Validation Packages. Each package
validates a subset of features or items. This section describes the device’s support level
for a BroadWorks Validation Package as well as the features or items in the package that
BroadWorks Package
Basic Call
Support Level
Full
Items Not Supported
BroadWorks Enhanced Services
Partial
Ring Splash
Priority Alerting
Priority Call Waiting
Alternate Numbers
Advanced Call Control
DUT Services – Call Control
Partial
Partial
Network Conference 3-Way
Network Conference N-Way
DUT Services – Registration and
Authentication
BroadWorks Authentication
DUT Services – FAX
DUT Services – Busy Lamp Field
Redundancy
Full
None
Partial
Call Setup Failover
Mid-Call Failover
SBC/ALG
Full
Shared Call Appearance
None
None
None
None
Feature Key Synchronization
Video
TCP
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 6 OF 23
3
Device Capabilities and Known Interoperability Issues
This section describes the features supported by the HT-286 / HT-386 / HT-486 / HT-488 /
HT-496 / BT-100, as well as BroadWorks interoperability issues and impact. The following
table describes capabilities.
Verified Revisions shows the results of partner (vendor) testing of a specific BroadWorks
version with a specific partner’s device under test (DUT) version.
Compatible Revisions indicates the maintenance versions that should interface properly
with BroadWorks.
3.1 Capabilities
Device Type
Lines and Appearances
SIP ATA
HT-286: 1 line
1 appearance per line
HT-386: 2 lines 1 appearance per line
HT-486: 1 line
HT-486: 1 line
1 appearance per line
1 appearance per line
HT-496: 2 lines 1 appearance per line
BT-100: 1 line
1 appearance per line
Speaker/Power/Bridge
HT-286: No/No/Yes
HT-386: No/No/Yes
HT-486: No/No/Yes
HT-488: No/No/Yes
HT-496: No/No/Yes
BT-100: Yes/No/Yes
Indicates speaker phone, in-line power, device
bridge/conference.
Verified Revisions
BroadWorks Release: 14.SP2
Grandstream HT-286: 1.1.0.8
Grandstream HT-386: 1.0.3.96
Grandstream HT-486: 1.1.0.8
Grandstream HT-488: 1.0.3.96
Grandstream HT-496: 1.0.3.96
Grandstream BT-100: 1.1.0.8
Compatible Revisions
BroadWorks Release: 14.SP2
Grandstream HT-286: any maintenance version of
1.1.0.8
Grandstream HT-386: any maintenance version of
1.0.3.96
Grandstream HT-486: any maintenance version of
1.1.0.8
Grandstream HT-488: any maintenance version of
1.0.3.96
Grandstream HT496: any maintenance version of
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 7 OF 23
1.0.3.96
Grandstream BT-100: any maintenance version of
1.1.0.8
SIP Proxy FQDN DNS Lookup
(A, SRV, NAPTR)
A, SRV
Outbound Proxy Configurable
Yes
Outbound Proxy FQDN DNS Lookup
(A, SRV, NAPTR)
A, SRV
BroadWorks Redundancy Enabled
BroadWorks Shared Call Appearance
No
N/A
No
BroadWorks Enhanced IP Phone
Configuration
Device Services
Call Forwarding, Call Transfer, 3-Way Conference, Call
Waiting, Call Hold
Device Call Control
Device-Controlled
(Device-Controlled or Flash INFO-
based)
Codecs
RFC 2833 DTMF
T.38 Fax
TCP
PCMU, PCMA, G723.1 G729A/B, iLBC, G726-32
Yes
Yes
No
TLS
No
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 8 OF 23
3.2 Interoperability Issues
This section lists the known interoperability issues between BroadWorks and partner
release(s). For more information on issues related to the particular software release, see
the partner release notes.
None.
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 9 OF 23
4
BroadWorks Device Identity/Profile
BroadWorks configurable device identify/profile is introduced in BroadWorks Release
14.0. This section applies only to BroadWorks Release 14.0 and later.
The following table identifies the required BroadWorks device identity/profile settings for
interoperability between the HT496 and BroadWorks. For an explanation of the profile
For most of the parameters below, an “X” indicates the parameter function is supported
and/or required. If the item is blank, it is not supported.
Grandstream HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100
Identify/Device Profile
Signaling Address Type
Number of Lines
Intelligent Proxy Addressing
HT-286/HT-486/BT-100: 1 line
HT-386/HT-488/HT-496: 2 lines
Ringback Tone/ Early Media
Support
Local Ringback – No Early Media
Authentication
Enabled
X
Registration Capable
Static Registration Capable
E.164 Capable
Trusted
Authenticate REFER
Authentication Override
Video Capable
X
X
RFC 3264 Hold
Route Advance
Wireless Integration
PBX Integration
Use Business Trunking Contact
Forwarding Override
Conference Device
Music On Hold Device
Auto Configuration Soft Client
Web Based Configuration URL
Auto Configuration Type
Reset Event
http//:%BWIPADDRESS%
2 Config File
checkSync
Enable Monitoring
CPE System File Name
ataSystem.txt/bt100System.txt
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 10 OF 23
Device File Format
%BWMACADDRESS%.txt
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 11 OF 23
5
BroadWorks Device Type
This section applies to BroadWorks Release 13.0 and before.
The following BroadWorks device type should be used for Grandstream HT-286 / HT-386
/ HT-486 / HT-488 / HT-496 / BT-100.
Grandstream HT-286
Grandstream HT-386
Grandstream HT-486
Grandstream HT-488
Grandstream HT-496
Grandstream BT-100
The above device types require BroadWorks Release 13 MP<patch number>. If the
BroadWorks system is currently at a lower patch level, either apply the necessary patch or
use the following generic device type until the system can be patched accordingly.
Generic SIP Smart (Proxy Addr)
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 12 OF 23
6
Configuration
Grandstream HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 can be configured
via Web GUI Interface as well as via Configuration File through TFTP or HTTP.
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 accepts configuration files in a
proprietary binary format which is produced by the Grandstream configuration tool. The
configuration tool creates a device configuration file based on a configuration template and
the device’s MAC address. All Grandstream products’ sample configuration templates are
available on Grandstream’s web site. A configuration template file contains all
configuration parameters available for a product, with comments describing allowed
values of the parameters. For a detailed parameter list, please refer to the corresponding
When Grandstream device boots up or reboots, it will issue request for a binary
configuration file named “cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the MAC address of
the device, i.e., “cfg000b820102ab”. The configuration file name should be in lower cases.
Grandstream offers free Configuration File generator software in both Linux/Unix and
Windows platform. Both Configuration File Generators can be downloaded from
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 can be configured with a
configuration file using the Trivial File Transfer Protocol (TFTP) or through its embedded
web server. The following examples describe how to set the parameters using a
configuration file. This configuration description assumes the HT-286 / HT-386 / HT-486 /
HT-488 / HT-496 / BT-100 will use the Dynamic Host Configuration Protocol (DHCP) to
obtain an IP address and other network settings. The HT-286 / HT-386 / HT-486 / HT-488
/ HT-496 / BT-100 should be configured to load the configuration file each time it resets or
re-synchronizes. For detailed information on automated provisioning, please check the
HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 User Manual Error! Reference
source not found..
The capabilities of the HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 have been
verified for use with BroadWorks based on the settings described in the following table.
For more information on the meaning, purpose, and applicability of the individual
configuration items, see the HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100
Configuration Files
Files Provided by Partner
Level
Description
HT-286 / HT-386 / HT-486 / HT-488 / HT-
496 / BT-100 Configuration Template
System and
Subscriber
Contains configurable parameters that
apply to an individual device in a
deployment.
Example: sipp1_config_1.1.0.8.txt
sipp2_config_1.0.3.96.txt
cfgMAC
System and
Subscriber
Binary configuration file generated
from configuration template and an
individual device’s MAC address.
Example: cfg000b82000000
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 13 OF 23
6.1 System Level Configuration
This section describes system-wide configuration items that are generally required for
each HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 to work with BroadWorks.
Subscriber-specific settings are described in the next section.
{THIS IS JUST AN EXAMPLE AND IS NOT INTENDED AS A COMPLETE OR
SUFFICIENT TABLE OF PARAMETERS. EACH DEVICE WILL VARY AND MAY BE
COMPLETELY DIFFERENT. IF YOUR DEVICE DOES NOT SUPPORT CONFIG
FILES USE GUI CAPTURES OR OTHER METHODS TO DESCRIBE THE
CONFIGURATION.}
Step
Command
Purpose
System Configuration Items
Set SIP Proxy/Domain.
Step 1
Set the HT-286 / HT-386 / HT-
486 / HT-488 / HT-496 / BT-100
SIP server to the Fully Qualified
Domain Name (FQDN) for the
BroadWorks Application Server
cluster.
sipProxy = as.broadworks.net
The domain must match the
domain configured for the
BroadWorks subscriber’s
line/port domain.
Set Outbound Proxy.
Step 2
Set the outbound proxy to the
session border controller (SBC)
if one is deployed between the
HT-286 / HT-386 / HT-486 / HT-
488 / HT-496 / BT-100 and
BroadWorks.
outBoundProxy =
sbc.broadworks.net
If there are redundant SBCs, set
it to the FQDN for the SBC
cluster.
Enable DNS SRV lookup.
Step 3
Step 4
Step 5
Step 6
Enable DNS SRV lookups.
Use_DNS_SRV = “Yes” ;
Set register mode.
Enable SIP register.
SIP Registration = “Yes”
Set SIP Timers.
The default registration period is
60 minutes.
Register Expiration = 60
Enable negotiated DTMF type.
Send DTMF = “via RTP (RFC2833)”
Set the HT-286 / HT-386 / HT-
486 / HT-488 / HT-496 / BT-100
to enable inband or RFC 2833
negotiated DTMF.
Disable local feature code
services.
Step 7
Step 8
Disable feature access codes
controlled by the device.
Enable Call Features = “No”
Enable BroadSoft mode.
Set the HT-286 / HT-386 / HT-
486 / HT-488 / HT-496 / BT-100
in BroadSoft mode.
Special Feature = “Broadsoft”
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 14 OF 23
6.2 Subscriber Level Configuration Parameters
This section identifies the device-specific parameters, including registration and
authentication. These settings must be unique across devices in order to be matched with
the settings for a BroadWorks subscriber.
Provisioning a subscriber to register with BroadWorks allows calls to terminate to the
subscriber’s line. Registration requires that a unique address of record (AoR) is
provisioned on BroadWorks and the phone; provisioning an AoR on BroadWorks consists
of setting the line/port parameter to a unique value within the Application Server cluster.
Grandstream HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 supports one SIP
accounts (lines), two SIP accounts, one SIP account, two SIP accounts, two SIP
accounts, and 1 SIP account, respectively. The follow example shows how to configure
subscriber elements for an account.
Step
Command
Purpose
Subscriber Configuration Items
Set Register User ID for each
line.
Step 1
Step 2
The register user ID must
correspond with the line/port
setting on BroadWorks.
Example:
SIP User_ID = "2405551111" ;
Enable SIP Authentication for
each line.
If the Authentication service is
configured on BroadWorks, these
parameters must be configured to
match the BroadWorks settings.
Example:
Authenticate ID =
Authenticate Password =
"welcome"
;
Configure display name for each
line.
Step 3
For each line, configure the name
to be displayed on the device.
Example:
Name = “Claire Smith” ;
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 15 OF 23
7
Enhanced IP Phone Configuration
Enhanced IP Phone Configuration is a BroadWorks feature that enables automatic
generation of device configuration files, given administrator-supplied templates.
For more information on the Enhanced IP Phone Configuration feature, see the Enhanced
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 uses only a phone-specific file
to configure the device. However, the Enhanced IP Phone Configuration feature requires
a system and a phone-specific file for each device. To satisfy the system file requirement,
an empty file (ataDefault.txt, bt100Desfult.txt) will need to be uploaded to BroadWorks as
the system file. This file will be sent to the FTP server but will not actually be used for the
configuration file generation. The group template file is used to build the configuration files
for the devices of this device type assigned to the group. For a sample HT-286 / HT-386 /
HT-486 / HT-488 / HT-496 / BT-100 group template file, see Appendix A.
NOTE: BroadSoft does not manage or distribute template files for use with the Enhanced IP
Phone Configuration feature. Obtain template files from Grandstream or use the configuration
files obtained from Grandstream for the specific Grandstream firmware release to create
template files appropriate for your installation.
Since HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 require the configuration files be
converted into a binary format, an extra step must be performed when using this feature. After
the configuration files have been sent to the TFTP server and before the phone is reset, the
configuration files must be converted to binary format using Grandstream’s configuration tool.
For detailed information on automated provisioning, please check the Grandstream configuration
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 16 OF 23
Appendix A: Sample HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100
Configuration Files
NOTE: The following samples are examples and should be used as a reference only. DO NOT CUT
AND PASTE THESE EXAMPLES TO GENERATE YOUR CONFIGURATION FILES. Use the
configuration files obtained from Grandstream with the specific release to generate your configuration
files.
System Default Parameters:
NOTE: This is an example file and should be used for reference only.
# SIP Default Generic Configuration File
####################################################
# Account 1
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #
####################################################
# SIP Server
P47 = as.broadworks.net
# Outbound Proxy
P48 = sbc.broadworks.net
# Use DNS SRV. 0 - no, 1 - yes.
P103 = 1
# SIP Registration. 0 - no, 1 - yes
P31 = 1
# Register Expiration (in minutes. default 1 hour, max 45 days)
P32 = 60
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO
P73 = 1
# Enable Call Features. 0 - no, 1 – yes
P191 = 0
# Special Feature. 102 – BroadSoft
P198 = 102
####################################################
# Account 2
#
#
#
####################################################
# SIP Server
P747 = as.broadworks.net
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 17 OF 23
# Outbound Proxy
P748 = sbc.broadworks.net
# Use DNS SRV. 0 - no, 1 - yes.
P702 = 1
# SIP Registration. 0 - no, 1 – yes
P731 = 1
# Register Expiration (in minutes. default 1 hour, max 45 days)
P732 = 60
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO
P773 = 1
# Enable Call Features. 0 - no, 1 – yes
P751 = 0
# Special Feature. 102 – BroadSoft
P767 = 102
Phone-Specific Parameters:
NOTE: This is an example file and should be used for reference only.
# SIP Device-specific Configuration File
####################################################
# Account 1
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #
####################################################
# SIP User ID
P35 = 2405551111
# Authenticate ID
P36 = [email protected]
# Authenticate password
P34 = welcome
# Display Name
P3 = Claire Smith
####################################################
# Account 2
#
#
#
####################################################
# SIP User ID
P735 =
# Authenticate ID
P736 =
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 18 OF 23
# Authenticate Password
P734 =
# Display Name
P703 =
Group Template File: ATA-GroupTemplate.txt /BT100- GroupTemplate.txt
NOTE: This is an example file and should be used for reference only.
####################################################
# SIP Default Generic Configuration Parameters
#
####################################################
####################################################
# Account 1
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #
####################################################
# SIP Server
P47 = as.broadworks.net
# Outbound Proxy
P48 = sbc.broadworks.net
# Use DNS SRV. 0 - no, 1 - yes.
P103 = 1
# SIP Registration. 0 - no, 1 - yes
P31 = 1
# Register Expiration (in minutes. default 1 hour, max 45 days)
P32 = 60
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO
P73 = 1
# Enable Call Features. 0 - no, 1 – yes
P191 = 0
# Special Feature. 102 – BroadSoft
P198 = 102
####################################################
# Account 2
#
#
#
####################################################
# SIP Server
P747 = as.broadworks.net
# Outbound Proxy
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 19 OF 23
P748 = sbc.broadworks.net
# Use DNS SRV. 0 - no, 1 - yes.
P702 = 1
# SIP Registration. 0 - no, 1 – yes
P731 = 1
# Register Expiration (in minutes. default 1 hour, max 45 days)
P732 = 60
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO
P773 = 1
# Enable Call Features. 0 - no, 1 – yes
P751 = 0
# Special Feature. 102 – BroadSoft
P767 = 102
####################################################
# SIP Device-specific Configuration Parameters
#
####################################################
####################################################
# Account 1
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #
####################################################
# SIP User ID
P35 = %BWLINEPORT-1%
# Authenticate ID
P36 = %BWAUTHUSER-1%
# Authenticate password
P34 = %BWAUTHPASSWORD-1%
# Display Name (John Doe)
P3 = %BWCLID-1%
####################################################
# Account 2
#
#
#
####################################################
# SIP User ID
P735 = %BWLINEPORT-2%
# Authenticate ID
P736 = %BWAUTHUSER-2%
# Authenticate Password
P734 = %BWAUTHPASSWORD-2%
# Display Name (John Doe)
P703 = %BWCLID-2%
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 20 OF 23
Appendix B: BroadWorks Validation Package Test Items
The following table describes the items tested in each BroadWorks Validation Package.
BroadWorks Validation Package
Items Supported
Basic Call
Basic Call Origination / Termination
Call Failure Codes
Session Audit
Ringback
Dial Plan
Inband DTMF
RFC 2833/Negotiation
DTMF Relay
Codec Renegotiation
BroadWorks Enhanced Services
Basic CommPilot Call Manager Functions
Voice Messaging Audio MWI
Voice Messaging Visual MWI
Ring Splash
Priority Alerting
Priority Call Waiting
Alternate Numbers
Advanced Call Control
Anonymous Call
Remote Restart
Call Park Retrieve – Answer with Hold
DUT Services – Call Control
Call Waiting
Call Hold
Blind Transfer
Attended Transfer
3-Way Call
Network Conference 3-Way
Network Conference N-Way
DUT Services – Registration and
Authentication
Authenticated Registration
Maximum Registration
Minimum Registration
Rejected Registration
Authenticated Origination
Authenticated Re-INVITE
Authenticated REFER
BroadWorks Authentication
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 21 OF 23
BroadWorks Validation Package
Items Supported
DUT Services - FAX
FAX Passthrough
FAX T38
DUT Services – Busy Lamp Field
Redundancy
Basic BLF
DNS
Registration Failover
Call Setup Failover
Mid-Call Failover
SBC/ALG
Registration
Call Origination
Call Termination
Shared Call Appearance
Line Seize
Line Lamp Management
Line Hold/Retrieve
Multiple Call Arrangement
SCA Bridging
Feature Key Synchronization
Video
Feature Key Synchronization
Integrated Video Phone
Video Services
Video Add-On
TCP
Basic
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 22 OF 23
References
[1] Grandstream Networks, Inc. 2007. HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-
100 User Manual. Download at:
AND GUI Interfaces:
[2] Grandstream Networks, Inc. 2007. Grandstream Configuration Tool and Templates.
[3] BroadSoft, Inc. 2006. BroadWorks Enhanced IP Phone Configuration Guide,
[4] BroadSoft, Inc. 2006. BroadWorks Device Inventory Guide, Release 14.0. Available
[5] BroadSoft, Inc. 2006. BroadWorks Redundancy Guide, Release 14.0. Available
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.
DOCUMENT NUMBER
PAGE 23 OF 23
|