Instructions – Parts List
2” BUNG MOUNT, 200 LITER (55 GALLON) DRUM SIZE
10:1 Ratio Presidentr Pump
308738C
Part No. 239326, Series A
62 bar (6.2 MPa, 900 psi) Maximum Fluid Working Pressure
6.2 bar (0.62 MPa, 90 psi) Maximum Air Input Pressure
Read warnings and instructions.
Refer to page 2 for the Table of Contents.
0359
II 1/2 G T2
ITS03ATEX11228
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 1998, Graco Inc. is registered to I.S. EN ISO 9001
WARNING
INJECTION HAZARD
Spray from the gun/valve, hose leaks, or ruptured components can inject fluid into your body and
cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the
skin can also cause serious injury.
D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medi-
cal attention.
D Do not point the gun/valve at anyone or at any part of the body.
D Do not put your hand or fingers over the spray tip/nozzle.
D Do not stop or deflect leaks with your hand, body, glove or rag.
D Do not “blow back” fluid; this is not an air spray system.
D Always have the tip guard and the trigger guard on the gun when spraying.
D Check the gun diffuser operation weekly. Refer to the gun manual.
D Be sure the gun/valve trigger safety operates before spraying/dispensing.
D Lock the gun/valve trigger safety when you stop spraying/dispensing.
D Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve pres-
sure; stop spraying/dispensing; clean, check, or service the equipment; and install or clean the
spray tip/nozzle.
D Tighten all fluid connections before operating the equipment.
D Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.
D Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the
hose from rupture caused by kinks or bends near the couplings.
MOVING PARTS HAZARD
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
D Keep clear of all moving parts when starting or operating the pump.
D Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the
equipment from starting unexpectedly.
308738
3
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
D If there is any static sparking or you feel an electric shock while using this equipment, stop spray-
ing/dispensing immediately. Do not use the equipment until you identify and correct the problem.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being sprayed/dispensed.
D Keep the spray/dispense area free of debris, including solvent, rags, and gasoline.
D Electrically disconnect all equipment in the spray/dispense area.
D Extinguish all open flames or pilot lights in the spray/dispense area.
D Do not smoke in the spray/dispense area.
D Do not turn on or off any light switch in the spray/dispense area while operating or if fumes are
present.
D Do not operate a gasoline engine in the spray/dispense area.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.
D Know the specific hazards of the fluid you are using.
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.
4
308738
Installation
NOTES:
D Pump: Use a ground wire and clamp. See Fig.1.
Loosen the grounding lug locknut (W) and washer
(X). Insert one end of a 12 ga (1.5 mm@) minimum
ground wire (Y) into the slot in lug (Z) and tighten
the locknut securely. Connect the other end of the
wire to a true earth ground. For a ground wire and
clamp, order Part No. 237569.
D Reference numbers and letters in parentheses in
the text refer to the callouts in the figures and
drawings.
D Always use Genuine Graco Parts and Accessories,
available from your Graco distributor. If you supply
your own accessories, be sure they are adequately
sized and pressure-rated to meet the system’s
requirements.
Z
Y
D Fig. 2 is only a guide for selecting and installing
system components and accessories. Contact your
Graco distributor for assistance in designing a
system to suit your particular needs.
Prepare the Operator
X
All persons who operate the equipment must be
trained in the safe, efficient operation of all system
components as well as the proper handling of all fluids.
All operators must thoroughly read all instruction
manuals, tags, and labels before operating the
equipment.
W
0720
Fig. 1
D Air and fluid hoses: Use only electrically conductive
hoses with 150 m (500 ft) maximum combined hose
length to ensure grounding continuity.
Prepare the Site
D Air compressor: Follow manufacturer’s
Ensure that you have an adequate compressed air
supply. Refer to the performance chart on page 15 to
find the air consumption of your pump.
recommendations.
D Spray gun or dispensing valve: Connect to a
properly grounded fluid hose and pump.
Keep the site clear of any obstacles or debris that
could interfere with the operator’s movement.
D Object being sprayed: Follow your local code.
D Fluid supply container: Follow your local code.
Have a grounded, metal pail available for use when
flushing the system.
D Solvent pails used when flushing: Follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding
continuity.
Mounting the Pump
Screw the bung adapter (B) tightly into the drum bung
hole and tighten the thumbscrew to hold the pump
about 13 mm (0.5 in.) off the bottom of the drum.
Loosen the drum vent plug to prevent forming a
vacuum. The pump dimensions are shown on page 13.
D To maintain proper grounding continuity when
flushing or relieving pressure, always hold the metal
part of the spray gun/dispense valve firmly to the
side of a grounded metal pail, then trigger the
gun/valve.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 4.
308738
5
Installation
Typical Installation
KEY
F
G
A
B
C
D
Pump
Bung adapter
Air line lubricator
Bleed-type master air valve (required for pump)
See Warning on page 7 for part number.
Pump air regulator
E
F
G
H
J
Air line filter
Bleed-type master air valve (for accessories)
Electrically conductive air supply hose
Air line moisture trap and drain valve
Pump runaway valve
E
D
C
K
Y
H
K
A
B
L
Fluid drain valve (required)
See Warning on page 7 for part numbers.
Electrically conductive fluid supply hose
Ground wire (required)
M
Y
Part No. 237569. See page 5 for installation instructions.
J
M
L
07201
Fig. 2
6
308738
Installation
Air Line Accessories
System Accessories
Install the following accessories in the order shown in
Fig. 2, using adapters as necessary:
WARNING
D Air line lubricator (C)
A bleed-type master air valve (D) and a fluid drain
valve (L) are required in your system. These
accessories help reduce the risk of serious injury
including fluid injection, splashing in the eyes or on
the skin, and injury from moving parts if you are
adjusting or repairing the pump.
Provides automatic air motor lubrication.
D Bleed-type master air valve (D)
Required in your system to relieve air trapped
between it and the air motor when the valve is
closed (see the WARNING at left). Be sure the
bleed valve is easily accessible from the pump, and
is located downstream from the air regulator (E).
The bleed-type master air valve relieves air trapped
between this valve and the pump after the air is
shut off. Trapped air can cause the pump to cycle
unexpectedly. Locate the valve close to the pump.
Order Part No. 113333.
D Air regulator (E)
Controls pump speed and outlet pressure by
adjusting the air pressure to the pump. Locate the
regulator close to the pump, but upstream from the
bleed-type master air valve (D).
The fluid drain valve assists in relieving fluid pres-
sure in the displacement pump, hose, and gun.
Triggering the gun to relieve pressure may not be
sufficient. Order one of the following:
D Pump runaway valve (K)
Senses if the pump is running too fast and shuts off
the air supply to the motor. A pump which runs too
fast can be seriously damaged.
Part No. Description
238635
210657
210658
210659
239018
235992
1/4 npt (mbe), carbon steel
1/4 npt (mbe), carbon steel
3/8 npt (mbe), carbon steel
1/4 npt x 3/8 npt (mbe), carbon steel
1/4 npt (mbe), stainless steel
1/4 npt x 3/8 npt (mbe), stainless steel
D Air line filter (F)
Install an air line filter (F) and a moisture trap and
drain valve (J) to help remove moisture and
contaminants from the compressed air supply.
D Second bleed-type air valve (G)
Air and Fluid Hoses
Isolates the air line accessories for servicing.
Locate upstream from all other air line accessories.
Be sure all air and fluid hoses are properly sized and
pressure-rated for your system. Use only electrically
conductive air and fluid hoses. Use a 13 mm (1/2 in.)
I.D. (minimum) air hose (H) to supply air to the pump.
Fluid Line Accessories
Install the following accessories in the positions shown
in Fig. 2, using adapters as necessary:
Fluid hoses must have spring guards on both ends.
Connect a fluid hose (M) to the pump’s 3/4 npt(f) fluid
outlet. Use of a short whip hose between the main
fluid hose and the gun allows freer gun movement.
D Fluid drain valve (L)
Required in your system to relieve fluid pressure in
the hose and gun (see the WARNING at left).
Install the drain valve so that it points down and the
handle points up when it is opened.
308738
7
Operation
Pressure Relief Procedure
Packing Nut/Wet-Cup
WARNING
WARNING
INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
starting or spraying accidentally. Fluid
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure at left.
Keep the packing nut/wet-cup (S) filled with Graco
Throat Seal Liquid (TSL) or compatible solvent to help
prolong the packing life. Check the tightness of the
packing nut weekly; tighten just enough to prevent
leakage; do not overtighten it. See Fig. 3 on page 11.
Relieve the pressure before adjusting the packing nut
or adding TSL.
under high pressure can be injected through the
skin and cause serious injury. To reduce the risk of
an injury from injection, splashing fluid, or moving
parts, follow the Pressure Relief Procedure
whenever you:
D are instructed to relieve the pressure,
D stop spraying,
D check or service any of the system equipment,
D or install or clean the spray tip.
Starting and Adjusting the Pump
Begin these steps before you install the spray
tip/nozzle.
1. Lock the gun trigger safety.
1. Ensure that the air regulator (E) and bleed-type
master air valve (D) are closed. See Fig. 2 on
page 6.
2. Shut off the air supply to the pump.
3. Close the bleed-type master air valve (required in
your system).
2. Hold a metal part of the gun/valve firmly to the side
of a grounded metal pail and hold the trigger open.
4. Unlock the gun/valve trigger safety.
3. Open the pump’s bleed-type master air valve (D).
5. Hold a metal part of the gun/valve firmly to the side
of a grounded metal pail, and trigger the gun/valve
to relieve pressure.
4. Slowly open the air regulator (E) until the pump
starts; approximately 2.8 bar (0.28 MPa, 40 psi).
6. Lock the gun/valve trigger safety.
5. Cycle the pump slowly until all the air is pushed
out and the pump and hoses are fully primed.
7. Open the drain valve (required in your system),
and have a container ready to catch the drainage.
6. Release the gun/valve trigger and lock the trigger
safety. The pump should stall against pressure
when you release the trigger.
8. Leave the drain valve open until you are ready to
spray again.
If you suspect that the spray tip/nozzle or hose is
completely clogged, or that pressure has not been fully
relieved after following the steps above, very slowly
loosen the tip guard retaining nut or hose end coupling
and relieve pressure gradually, then loosen it
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure at left.
completely. Then clear the tip/nozzle or hose.
7. Relieve the pressure.
Flush the Pump Before First Use
The pump is tested with lightweight oil, which is left in
to protect the pump parts. If the fluid you are using
may be contaminated by the oil, flush it out with a
compatible solvent before using the pump. If the pump
is being used to supply a circulating system, allow the
solvent to circulate until the pump is thoroughly
flushed. See Flushing the Pump on page 9.
8. Install the spray tip/nozzle in the gun/valve.
8
308738
Operation
Flushing the Pump
WARNING
COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause
WARNING
FIRE AND EXPLOSION HAZARD
Before flushing, read the section FIRE
AND EXPLOSION HAZARD on page
4. Be sure the entire system and
flushing pails are properly grounded.
Refer to Grounding on page 5.
component rupture and serious injury,
never exceed the specified maximum air input
pressure to the pump (see Technical Data on
page 14).
9. Control the pump speed and fluid pressure with
the air regulator (E). Always use the lowest air
pressure necessary to get the desired results.
Higher pressure causes premature spray
tip/nozzle and pump wear.
Flush with a fluid that is compatible with the fluid you
are pumping and with the wetted parts in your system.
Check with your fluid manufacturer or supplier for
recommended flushing fluids and flushing frequency.
Always flush the pump before fluid dries on the
displacement rod.
10. With the pump and lines primed, and with
adequate air pressure and volume supplied, the
pump starts and stops as the gun/valve is opened
and closed. In a circulating system, the pump runs
continuously and speeds up or slows down as
supply increases or decreases until the air supply
is shut off.
CAUTION
Never leave water or water-base fluid in the pump
overnight. If you are pumping water-base fluid, flush
with water first, then with a rust inhibitor such as
mineral spirits. Relieve the pressure, but leave the
rust inhibitor in the pump to protect the parts from
corrosion.
CAUTION
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a high
speed, possibly damaging itself. If your pump accel-
erates quickly, or is running too fast, stop it immedi-
ately and check the fluid supply. If the supply con-
tainer is empty and air has been pumped into the
lines, refill the container and prime the pump and the
lines with fluid, or flush and leave it filled with a
compatible solvent. Be sure to eliminate all air from
the fluid system.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
1. Relieve the pressure.
2. Remove the spray tip/nozzle from the gun/valve.
Shutdown and Care of the Pump
3. Hold a metal part of the gun/valve firmly to the side
of a grounded metal pail.
WARNING
4. Start the pump. Always use the lowest possible
fluid pressure when flushing.
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
5. Trigger the gun/valve.
6. Flush the system until clear solvent flows from the
gun/valve.
For overnight shutdown, relieve the pressure, and
always stop the pump at the bottom of the stroke to
prevent the fluid from drying on the exposed
7. Relieve the pressure.
displacement rod and damaging the throat packings.
Always flush the pump before the fluid dries on the
displacement rod. See Flushing the Pump.
308738
9
Troubleshooting
1. Relieve the pressure.
WARNING
2. Check all possible problems and solutions before
disassembling pump.
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
Problem
Cause
Restricted line or inadequate air
Solution
Pump fails to operate.
Clear; increase air supply.
supply.
Insufficient air pressure; closed or
clogged air valves, etc.
Open; clean (be sure to use air fil-
ter).
Exhausted fluid supply.
Refill; purge all air from pump and
fluid lines.
Damaged air motor.
Service air motor. See manual
306982.
Fluid intake or piston valve needs
adjustment.
Adjust. See manual 307044.
Pump operates but output is low on Restricted line or inadequate air
Clear; increase air supply.
both strokes.
supply.
Insufficient air pressure; closed or
clogged air valves, etc.
Open; clean (be sure to use air
filter).
Exhausted fluid supply.
Refill; purge all air from pump and
fluid lines.
Clogged fluid line, valves, etc.
Clear*.
Loose packing nut or worn throat
packings.
Tighten packing nut (see page 8);
replace throat packings.
Damaged riser tube o-rings.
Replace. See manual 307044.
Pump operates but output is low on Held open or worn intake valve.
downstroke.
Clear; service. See manual 307044.
Damaged riser tube o-rings.
Replace. See manual 307044.
Pump operates but output is low on Held open or worn fluid piston valve Clear; service. See manual 307044.
upstroke.
or packings.
Erratic or accelerated operation.
Exhausted fluid supply.
Refill; purge all air from pump and
fluid lines.
Held open or worn intake valve.
Clear; service. See manual 307044.
Held open or worn fluid piston valve Clear; service. See manual 307044.
or packings.
Damaged riser tube o-rings.
Replace. See manual 307044.
* To determine if the fluid hose or gun is obstructed, relieve the pressure and disconnect the fluid hose, and place
a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump; about 1.4 to
2.8 bar (0.14 to 0.28 MPa, 20 to 40 psi). If the pump starts when the air is turned on, the obstruction is in the
fluid hose or gun.
10
308738
Service
Disconnecting the Displacement Pump
1
Lubricate.
Torque to 27 to 41 NSm (20 to 30 ft-lb).
2
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
1. Flush the pump if possible. Stop the pump at the
bottom of its stroke. Relieve the pressure.
1
2. Disconnect the air and fluid hoses. Unscrew the
bung adapter (4) from the bung hole in the drum
cover and pull the pump out of the drum. Note the
relative position of the fluid outlet (N) to the air inlet
(P). See Fig. 3.
P
9
6
1
3. Unscrew the tie rod locknuts (7) from the tie rods
(6). Remove the cotter pin (8). Carefully pull the
displacement pump (2) off the air motor (1).
Unscrew the displacement rod (R) from the air
motor (1). Inspect the o-ring (9).
R
S
7
8
2
4. Refer to manual 307044 for displacement pump
service. To service the air motor, refer to manual
306982.
N
5
4
Reconnecting the Displacement Pump
2
1. Lubricate the o-ring (9) and check that it is in place
on the displacement rod (R).
2. Orient the fluid outlet (N) to the air inlet (P) as
noted in step 2 under Disconnecting the
Displacement Pump. Position the displacement
pump (2) on the tie rods (6). See Fig. 3.
07200
Fig. 3
3. Screw the displacement rod (R) into the shaft of
the air motor (1) until the pin holes are aligned.
Install the cotter pin (8). Screw the locknuts (7)
onto the tie rods (6) loosely.
4. Mount the pump and reconnect all hoses.
Reconnect the ground wire if it was disconnected
during repair. Tighten the packing nut (S). Fill the
wet-cup with Graco Throat Seal Liquid or
compatible solvent.
5. Tighten the tie rod locknuts (7) evenly, and torque
to 27 to 41 NSm (20 to 30 ft-lb). Start the pump
and run it at about 2.8 bar (0.28 MPa, 40 psi) air
pressure, to check that it is operating properly.
308738 11
Parts
Part No. 239326, Series A
Ref
No.
Part
No.
Description
Qty
1
2
3
207352
220465
222308
AIR MOTOR
1
see manual 306982
DISPLACEMENT PUMP ASSY,
see manual 307044
BUNG ADAPTER;
1
1
consists of items 4 and 5
. ADAPTER
. CAPSCREW
ROD, tie; carbon steel; 89 mm
(3.5 in.) shoulder to shoulder
NUT, lock, 3/8–16
PIN, cotter, stainless steel
O-RING; buna-N
1
1
1
4
5
6
210834
104542
166237
6
7
9
3
3
1
1
7
8
9
101566
100103
156082
8
2
5
4
07200
12
308738
Dimensions
Dimension
Measurement
883 mm (34.75 in.)
1454 mm (57.25 in.)
1/2 npt(f)
A
B
D
E
F
3/4 npt(f)
3/4 npt(f)
G
2 in. npt
D
(air inlet)
B
E
(fluid outlet)
G
(bung
adapter)
A
F
(fluid intake)
07199
308738 13
Technical Data
Category
Data
Ratio
10:1
Maximum fluid working pressure
Maximum air input pressure
Fluid flow at 60 cycles per minute
Maximum pump operating temperature
Wetted parts
62 bar (6.2 MPa, 900 psi)
6.2 bar (0.62 MPa, 90 psi)
11 liters/min (3 gpm)
82_C (180_F)
Refer to manual 307044.
Sound Pressure Levels (dBa)
(measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
Air Motor
2.8 bar (0.28 MPa, 40 psi)
73.6 dB(A)
4.8 bar (0.48 MPa, 70 psi)
7 bar (0.7 MPa, 100 psi)
80.9 dB(A)
President
78.3 dB(A)
Sound Power Levels (dBa)
(tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
Air Motor
2.8 bar (0.28 MPa, 40 psi)
4.8 bar (0.48 MPa, 70 psi)
7 bar (0.7 MPa, 100 psi)
President
87.4 dB(A)
92.1 dB(A)
94.6 dB(A)
14
308738
Technical Data
Performance Chart
KEY:
psi
Fluid Outlet Pressure – Black Curves
Air Consumption – Gray Curves
cycles per minute
scfm
bar, MPa
m#/min
10
20
30
40
50
60
900
60
A
B
C
6.2 bar (0.62 MPa, 90 psi) Air Pressure
4.9 bar (0.49 MPa, 70 psi) Air Pressure
2.8 bar (0.28 MPa, 40 psi) Air Pressure
A
B
62, 6.2
1.68
To find fluid outlet pressure (bar/MPa/psi) at a
specific fluid flow (lpm/gpm) and operating air
pressure (bar/MPa/psi):
40
1.12
600
42, 4.2
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with
selected fluid outlet pressure curve (black).
Follow left to scale to read fluid outlet pressure.
A
B
To find pump air consumption (m#/min or scfm)
at a specific fluid flow (lpm/gpm) and air pressure
(bar/MPa/psi):
C
20
0.56
300
21, 2.1
C
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with
selected air consumption curve (gray). Follow
right to scale to read air consumption.
0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
gpm
liters/minute
1.9
3.8
5.7
7.6
9.5
11.4
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
308738 15
The Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,
Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be
defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or
substitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility
of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties
reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures
judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
1–800–328–0211 Toll Free
612–623–6921
612–378–3505 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Sales Office: Minneapolis
International Offices: Belgium, Korea, Hong Kong, Japan
PRINTED IN USA 308738 01/1998, Revised 05/2004
16
308738
|