Instructions–Parts List
STAINLESS STEEL
Check–Mate 200 Pumpst
WITH PRIMING PISTON, AND
SEVERE-DUTY ROD AND CYLINDER
308200D
Model 222839, Series A
23:1 Ratio Monarkr Pump
180 psi (1.2 MPa, 12 bar) Maximum Air Input Pressure
4140 psi (29 MPa, 285 bar) Maximum Fluid Working Pressure
Model 222907, Series A
46:1 Ratio Presidentr Pump
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
4600 psi (32 MPa, 317 bar) Maximum Fluid Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Table of Contents
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Model 222907 Shown
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Service
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Disconnecting the Displacement Pump . . . . . . . . 12
Reconnecting the Displacement Pump . . . . . . . . 13
Displacement Pump Service . . . . . . . . . . . . . . . . . 14
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Mounting Hole Layout . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Graco Phone Numbers . . . . . . . . . . . . . . . . . . . . . . . . . 30
01057
WARNING
SKIN INJECTION HAZARD
Spray from the spray gun/dispense valve, hose leaks or ruptured components can inject fluid into your
body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes
or on the skin can also cause serious injury.
D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate
surgical treatment.
D Do not point the gun/valve at anyone or at any part of the body.
D Do not put your hand or fingers over the spray tip/nozzle.
D Do not stop or deflect leaks with your hand, body, glove or rag.
D Do not “blow back” fluid; this is not an air spray system.
D Always have the tip guard and the trigger guard on the spray gun when spraying.
D Check the gun diffuser operation weekly. Refer to the gun manual.
D Be sure the gun/valve trigger safety operates before spraying/dispensing.
D Lock the gun/valve trigger safety when you stop spraying/dispensing.
D Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve pres-
sure; stop spraying/dispensing; clean, check, or service the equipment; and install or clean the
spray tip/nozzle.
D Tighten all fluid connections before operating the equipment.
D Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.
D Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the
hose from rupture caused by kinks or bends near the couplings.
MOVING PARTS HAZARD
Moving parts, such as the priming piston, can pinch or amputate your fingers.
D Keep clear of all moving parts when starting or operating the pump.
D Keep hands and fingers away from the priming piston during operation and whenever the pump is
charged with air.
D Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the
equipment from starting unexpectedly.
308200
3
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
D Ground the equipment and the object being sprayed. Refer to Grounding on page 6.
D If there is any static sparking or you feel an electric shock while using this equipment, stop spray-
ing/dispensing immediately. Do not use the equipment until you identify and correct the problem.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being sprayed/dispensed.
D Keep the spray/dispense area free of debris, including solvent, rags, and gasoline.
D Electrically disconnect all equipment in the spray/dispense area.
D Extinguish all open flames or pilot lights in the spray/dispense area.
D Do not smoke in the spray/dispense area.
D Do not turn on or off any light switch in the spray/dispense area while operating or if fumes are
present.
D Do not operate a gasoline engine in the spray/dispense area.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.
D Know the specific hazards of the fluid you are using.
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.
4
308200
Installation
The Typical Installation on page 7 shows the pump
General Information
(A) mounted on a pneumatic elevator cart (B). The
pump may also be mounted on a 19 liter (5 gal.) pail
ram. In either case, it is used with a wiper plate (C).
Refer to the separate manuals for the cart, ram, and
wiper plate for further information.
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawings.
NOTE: If you supply your own accessories, be sure
they are adequately sized and pressure–rated to meet
the system’s requirements.
Kits 223881 and 224829 are available to mount the
pump on a 200 liter (55 gallon) ram. Refer to the
separate manuals included with the kits for further
information.
Fig. 2 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
Air Line Accessories
Install the following accessories as shown in Fig. 2,
using adapters as necessary:
System Accessories
D A pump runaway valve (G) senses when the
pump is running too fast and automatically shuts off
the air to the motor. A pump which runs too fast can
be seriously damaged. Install closest to the pump
air inlet.
WARNING
Two accessories are required in your system: a
bleed–type master air valve (J) and a fluid drain
valve (N). These accessories help reduce the risk
of serious bodily injury including fluid injection,
splashing in the eyes or on the skin, and injury from
moving parts if you are adjusting or repairing the
pump.
D An air line lubricator (H) provides automatic air
motor lubrication.
D A bleed-type master air valve (J) is required in
your system to relieve air trapped between it and
the air motor when the valve is closed (see the
WARNING at left). Be sure the bleed valve is easily
accessible from the pump, and is located down-
stream from the air regulator.
The bleed–type master air valve relieves air
trapped between this valve and the pump after the
air is shut off. Trapped air can cause the pump to
cycle unexpectedly. Locate the valve close to the
pump.
D An air regulator (K) controls pump speed and
outlet pressure by adjusting the air pressure to the
pump. Locate the regulator close to the pump, but
upstream from the bleed-type master air valve.
The fluid drain valve assists in relieving fluid pres-
sure in the displacement pump, hose, and gun.
Triggering the gun to relieve pressure may not be
sufficient.
D An air line filter (L) removes harmful dirt and
moisture from the compressed air supply.
Air and Fluid Hoses
Be sure all air and fluid hoses are properly sized and
pressure-rated for your system. Use only grounded air
and fluid hoses. Fluid hoses must have a braided
stainless steel cover (or have spring guards on both
ends).
D A second bleed-type air valve (M) isolates the air
line accessories for servicing. Locate upstream
from all other air line accessories.
D An air line quick disconnect coupler (F) is
required for pumps mounted on the pneumatic
elevator cart. The female coupler attaches to the
end of the air hose (D), and the male coupler
screws into the air manifold (E). See the separate
cart manual for further information.
Mounting Accessories
Mount the pump (A) to suit the type of installation
planned. The pump dimensions and mounting hole
layouts are shown on pages 28 and 29.
308200
5
Installation
Fluid Line Accessories
W
Install the following accessories in the positions shown
in Fig. 2, using adapters as necessary:
X
Z
Y
D A fluid drain valve (N) is required in your system
to relieve fluid pressure in the hose and gun (see
the WARNING at left). Screw the drain valve into
the open branch of a tee mounted in the fluid line.
Install the drain valve pointing down, but so the
handle points up when opened.
0864
Fig. 1
D A fluid regulator (P) controls fluid pressure to the
gun/valve, and dampens pressure surges.
D A gun or valve (S) dispenses the fluid. The gun
shown in the Typical Installation is a dispensing gun
for highly viscous fluids.
2. Air and fluid hoses: use only electrically conductive
hoses.
3. Air compressor: follow manufacturer’s recommen-
D A gun swivel (T) allows freer gun movement.
dations.
4. Spray gun/dispense valve: ground through connec-
Grounding
tion to a properly grounded fluid hose and pump.
5. Fluid supply container: follow your local code.
6. Object being sprayed: follow your local code.
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 4.
7. All solvent pails used when flushing: follow your
local code. Use only metal pails, which are con-
ductive, placed on a grounded surface. Do not
place the pail on a nonconductive surface, such as
paper or cardboard, which interrupts the grounding
continuity.
1. Pump: use a ground wire and clamp. See Fig. 1.
Loosen the grounding lug locknut (W) and washer
(X). Insert one end of a 1.5 mm@ (12 ga) minimum
ground wire (Y) into the slot in lug (Z) and tighten
the locknut securely. Connect the other end of the
wire to a true earth ground. Order Part No. 237569
Ground Wire and Clamp.
8. To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
gun/valve firmly to the side of a grounded metal
pail, then trigger the gun/valve.
6
308200
Installation
KEY
A
B
C
D
E
F
G
H
J
K
L
Pump
Pneumatic Elevator Cart
Wiper Plate
MAIN AIR LINE
L
Air Hose
Air Manifold
Air Line Quick Disconnect Coupler
Pump Runaway Valve
Air Line Lubricator
Bleed-Type Master Air Valve (required, for pump)
Air Regulator
Air Line Filter
M
M
N
P
R
S
T
Bleed-Type Master Air Valve (for accessories)
Fluid Drain Valve (required)
Fluid Pressure Regulator
Fluid Hose
Gun or Dispensing Valve
Gun/Valve Swivel
Y
Ground Wire (required)
A
Y
G
H
J
D
K
E
F
B
P
N
R
C
S
T
19 LITER (5 GAL.) PAIL
01058
Fig. 2
308200
7
Operation
Pressure Relief Procedure
Packing Nut/Wet-Cup
Before starting, fill the packing nut (2) 1/3 full with
Graco Throat Seal Liquid (TSL) or compatible solvent.
See Fig. 3. Adjust the packing nut weekly so it is just
snug; do not overtighten.
WARNING
SKIN INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
starting or dispensing accidentally. Fluid
under high pressure can be injected through the
skin and cause serious injury. To reduce the risk of
an injury from injection, splashing fluid, or moving
parts, follow the Pressure Relief Procedure
whenever you:
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure at left.
D are instructed to relieve the pressure,
D stop spraying/dispensing,
D check or service any of the system equipment,
D or install or clean the spray tip/nozzle.
1. Lock the gun/valve trigger safety.
Air Motor Plate
2. Close the pump’s bleed-type air valve (required in
your system).
3. Shut off the master air bleed valve (required in
your system).
4. Unlock the gun/valve trigger safety.
2
5. Hold a metal part of the gun/valve firmly to the side
of a grounded metal pail, and trigger the gun/valve
to relieve pressure.
6. Lock the gun/valve trigger safety.
7. Open the drain valve (required in your system),
having a container ready to catch the drainage.
8. Leave the drain valve open until you are ready to
spray/dispense again.
If you suspect that the spray tip/nozzle or hose is
completely clogged, or that pressure has not been fully
relieved after following the steps above, very slowly
loosen the tip guard retaining nut or hose end coupling
and relieve pressure gradually, then loosen completely.
Now clear the tip/nozzle or hose.
23
01057
Fig. 3
8
308200
Operation
NOTE: When changing fluid containers with the hose
Flush the Pump Before First Use
and gun already primed, be sure to open the bleeder
valve (33), to assist in priming the pump and venting
air before it enters the hose. Close the valve when all
air has been eliminated.
The pump is tested with lightweight oil, which is left in
to protect the pump parts. If the fluid you are using
may be contaminated by the oil, flush it out with a
compatible solvent. See Flushing on page 10.
Starting and Adjusting the Pump
WARNING
SKIN INJECTION HAZARD
WARNING
MOVING PARTS HAZARD
See Fig. 3. The priming piston (23) and
the air motor piston (located behind the
air motor plates) move during operation.
To reduce the risk of fluid injection, do not use
your hand or fingers to cover the bleed hole on the
underside of the bleeder valve body when priming
the pump. Use a crescent wrench to open and
close the bleeder plug. Keep your hands away from
the bleed hole.
Keep hands and fingers away from the priming
piston (23) during operation and whenever the
pump is charged with air. The priming piston ex-
tends beyond the intake cylinder (20) to pull materi-
al into the pump and can amputate a hand or finger
caught between it and the intake cylinder. Follow
the Pressure Relief Procedure on page 8,
before checking, clearing, or cleaning the priming
piston to prevent the pump from starting acciden-
tally.
With the pump and lines primed, and with adequate air
pressure and volume supplied, the pump will start and
stop as the spray gun/dispensing valve is opened and
closed.
Use the air regulator (K) to control the pump speed and
the fluid pressure. Always use the lowest air pressure
necessary to get the desired results. Higher pressures
cause premature tip/nozzle and pump wear.
Never operate the pump with the air motor plates
removed.
WARNING
See the Installation on page 7. If you are using a
pneumatic elevator cart or 19 liter (5 gallon) ram with
the pump, refer to the separate instructions for those
components for set-up and operation instructions.
To reduce the risk of overpressurizing the system,
which could result in component rupture and cause
serious injury, NEVER exceed the specified maxi-
mum incoming air pressure to the pump (see the
Technical Data on pages 24–27).
Lower the pump into a fluid container. Be sure the air
regulator (K) and bleed-type master air valve (J) are
closed. Then open the bleed valve (J). Hold a metal
part of the spray gun/dispensing valve (S) firmly to the
side of a grounded metal pail and hold the trigger
open. Now slowly open the air regulator until the pump
starts.
CAUTION
Do not allow the pump to run dry. It will quickly
accelerate to a high speed, causing damage. A
pump runaway valve (G), which shuts off the air
supply to the pump if the pump accelerates beyond
the pre-set speed, is available. See the Typical
Installation in Fig. 2. If your pump accelerates
quickly, or is running too fast, stop it immediately and
check the fluid supply. If the supply container is
empty and air has been pumped into the lines, refill
the container and prime the pump and the lines with
fluid, or flush and leave it filled with a compatible
solvent. Be sure to eliminate all air from the fluid
system.
Cycle the pump slowly until all the air is pushed out
and the pump and hoses are fully primed. Release the
spray gun/dispensing valve trigger and engage the
safety latch. The pump should stall against pressure
when the trigger is released.
If the pump fails to prime properly, open the bleeder
valve (33) slightly. See Fig. 7 on page 16. Use the
bleeder hole (on the underside of the valve housing) as
a priming valve until the fluid appears at the hole.
Close the bleeder valve.
308200
9
Operation
Shutdown and Care of the Pump
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
For overnight shutdown, stop the pump at the bottom
of the stroke to prevent fluid from drying on the ex-
posed displacement rod and damaging the throat
packings. Relieve the pressure.
Always flush the pump before the fluid dries on the
displacement rod. Refer to Flushing below.
1. Relieve the pressure.
Flushing
2. Remove the spray tip/nozzle from the gun/valve.
WARNING
3. Hold a metal part of the gun/valve firmly to the side
of a grounded metal pail.
FIRE AND EXPLOSION HAZARD
Before operating the pump, read the
section FIRE AND EXPLOSION HAZ-
ARD on page 4. Be sure the entire
system and flushing pails are properly
grounded. Refer to Grounding on page
6.
4. Start the pump. Always use the lowest possible
fluid pressure when flushing.
5. Trigger the gun/valve.
Flush with a fluid that is compatible with the fluid you
are pumping and with the wetted parts in your system.
Check with your fluid manufacturer or supplier for
recommended flushing fluids and flushing frequency.
Always flush the pump before fluid dries on the dis-
placement rod.
6. Flush the system until clear solvent flows from the
gun/valve.
7. Relieve the pressure.
10
308200
Troubleshooting
1. Relieve the pressure.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
2. Check all possible problems and causes before
disassembling the pump.
PROBLEM
CAUSE
SOLUTION
Pump fails to operate. Restricted line or inadequate air supply Clear*; see Technical Data on pages 24–27.
Obstructed fluid hose or gun/valve;
fluid hose ID is too small.
Clear*; use a hose with a larger ID.
Fluid dried on the displacement rod.
Dirty or worn air motor parts.
Clean; see Service on pages 12–19.
Clean or repair; see separate air motor manual.
Pump operates, but Restricted line or inadequate air supply. Clear*; see Technical Data on pages 24–27.
output is low on both
strokes.
Obstructed fluid hose or gun/valve;
fluid hose ID is too small.
Clear*; use a hose with a larger ID.
Close.
Bleeder valve is open.
Air is leaking into the supply container. Check wiper plate seal.
Fluid is too heavy for pump priming. Use bleeder valve (see page 9); use wiper plate
with ram or pneumatic elevator cart.
Worn packings in displacement pump. Replace packings.
Pump operates, but Fluid too heavy for pump priming.
output is low on down-
stroke.
Use bleeder valve (see page 9); use wiper plate
with ram or pneumatic elevator cart.
Held open or worn intake valve or seals. Clear valve; replace seals.
Pump operates, but Held open or worn piston valve or seals. Clear valve; replace seals.
output is low on up-
stroke.
Erratic or accelerated Exhausted fluid supply.
pump speed.
Refill and prime.
Fluid is too heavy for pump priming.
Use the bleeder valve (see page 9); use wiper
plate with ram or pneumatic elevator cart.
Held open or worn piston valve or seals. Clear valve; replace seals.
Held open or worn priming piston. Clear; service.
Worn packings in displacement pump. Replace packings.
* To determine if the fluid hose or gun is obstructed, follow the Pressure Relief Procedure on page 8. Disconnect
the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to start
the pump (about 20–40 psi [0.14–0.3 MPa, 1.4–2.8 bar]). If the pump starts when the air is turned on, the obstruc-
tion is in the fluid hose or gun.
NOTE: If you experience air motor icing, contact your Graco distributor for assistance.
308200 11
Service
2. Relieve the pressure.
Required Tools
D Torque wrench
D Bench vise, with soft jaws
D Rubber mallet
D Hammer
D Razor or other sharp tool
D 8 mm (5/16 in.) dia. brass rod
3. Disconnect the air hose. Hold the fluid outlet fitting
(7) with an adjustable wrench to keep it from being
loosened while you disconnect the fluid hose.
Remove the pump from its mounting. Note the
relative position of the pump’s fluid outlet to the air
inlet.
D 8 mm, 11 mm, 15 mm, 25 mm, 3/4 in., and 7/8 in.
4. Using an adjustable wrench, unscrew the coupling
nut (104) from the connecting rod (103). Remove
the coupling collars (105). Take care not to lose or
drop them. See Fig. 4.
open–end wrenches
D 17 mm box or socket wrench
D 22 mm crow’s–foot wrench
D Adjustable wrenches
5. Hold the tie rod flats with an 11 mm wrench to
keep them from turning. Use the wrench (113)
provided with the pump (or a 17 mm box or socket
wrench) to unscrew the locknuts (106) from the tie
rods (102). Carefully pull the displacement pump
(107) off the air motor (101).
D 24 in. adjustable wrench
D Thread lubricant
D Anaerobic thread sealant
Disconnecting the Displacement Pump
1. Flush the pump, if possible. Stop the pump at the
bottom of its stroke.
6. Refer to page 14 for displacement pump service.
To service the air motor, refer to the separate air
motor manual, supplied.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
Keep hands and fingers away from the priming
piston during operation and whenever the pump is
charged with air. On the pump downstroke the
priming piston extends beyond the intake cylinder
to pull the material into the pump. The priming
piston works under extreme force. During operation
and whenever the pump is charged with air, the
priming piston can severely injure or amputate a
hand or finger, or break a tool, caught between it
and the intake cylinder.
The air motor piston (located behind the air motor
plates) also moves when air is supplied to the
motor. NEVER operate the pump with the air motor
plates removed.
12
308200
Service
Reconnecting the Displacement Pump
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
101
1. Orient the pump’s fluid outlet to the air motor’s air
inlet as was noted in step 3 under Disconnecting
the Displacement Pump. Position the displace-
ment pump (107) on the tie rods (102). See Fig. 4.
108
103
2
102
105
NOTE: If you removed the tie rods (102) from the air
motor (101) or air motor adapter plate, reinstall them
using an 11 mm wrench. Torque the rods to 20-25 N.m
(15-18 ft-lb) on Model 222907, and 34-41 N.m (25-30
ft-lb) on Model 222839.
104
1
1
2. Screw the locknuts (106) onto the tie rods (102)
and torque to 34-41 N.m (25-30 ft-lb), using the
wrench (113) provided (or a 17 mm box or socket
wrench).
2
3
106
3. Place the coupling nut (104) on the displacement
rod (1), then place the collars (105) in the nut.
Screw the nut onto the connecting rod (103)
loosely. Hold the connecting rod flats with an
adjustable wrench to keep it from turning. Using an
adjustable wrench, torque the nut to 41-48 N.m
(30-35 ft-lb).
7
113
4
107
4. Using a torque wrench in the square hole of the
supplied wrench (113), torque the packing nut (2)
to 27-34 N.m (20-25 ft-lb).
1
2
Torque to 30–35 ft–lb (41–48 NSm).
Torque to 15–18 ft–lb (20–25 NSm) on model 222907; 25–30
ft–lb (34–41 NSm) on model 222839.
3
4
Torque to 20–25 ft–lb (27–34 NSm).
Torque to 25–30 ft–lb (34–41 NSm).
5. Mount the pump and reconnect all hoses. Recon-
nect the ground wire if it was disconnected during
repair. Turn on the air and run the pump slowly.
01059
Fig. 4
6. Fill the packing nut/wet-cup 1/3 full of Graco
Throat Seal Liquid or compatible solvent.
308200 13
Service
7. Inspect the rod guide (17) while in place in the
Disassembly
housing (16). Remove the rod guide only if it is
visibly damaged. Using a hammer and brass rod,
gently tap around the outer edge of the guide to
loosen it.
When disassembling the pump, lay out all removed
parts in sequence, to ease reassembly. Refer to Fig. 7.
NOTE: Repair Kit 222784 is available separately to
replace the piston and intake valve seals. For the best
results, use all the new parts in the kit. Kit parts are
marked with one asterisk, for example (8*). See Dis-
placement Pump Parts on page 23.
8. Push the displacement rod (1) down as far as
possible, then pull it and the priming piston rod
(21) out of the outlet housing (9) and cylinder (11).
Repair Kit 222785 is available to replace the throat
packings. For the best results, use all the new parts in
the kit. Kit parts are marked with a check mark, for
example (3n).
9. Remove the packing nut (2) and throat packings
from the outlet housing (9). Do not remove the
fluid outlet nipple (7) and o-ring (8) unless dam-
aged.
1. Disconnect the displacement pump from the air
motor as explained on page 12.
10. Unscrew the plug (AA) of the bleeder valve (33)
completely from the valve housing (BB). Do not
unscrew the valve housing from the outlet housing
(9), because the threads may gall. Clean the valve
threads and the bleed hole on the underside of the
valve housing.
2. Place the pump in a vise, with the jaws on the
outlet housing (9).
3. Hold the flats of the priming piston rod (21) with an
8 mm wrench. Using a 3/4 in. wrench, unscrew the
priming piston nut (22) from the rod. Slide the
priming piston (23) and priming piston guide (24)
off the rod. Inspect the surfaces of the guide (24)
and piston (23) for scoring, wear, or other damage.
11. Use a 24 in. adjustable wrench on the pump
cylinder (11) flats to unscrew it from the housing
(9). Remove the o-rings (10). Inspect the inside of
the cylinder for damage by holding it up to the light
at an angle or running a finger over the surface.
4. Loosen the packing nut (2) using the packing nut
wrench (113, supplied), or a hammer and brass
rod.
12. Inspect the surface of the displacement rod (1)
and priming piston rod (21) for wear, scoring or
other damage by running a finger over the surface.
5. Remove the intake cylinder (20), using a 24 in.
adjustable wrench. Remove the seal (19) and seat
(18) from the intake valve housing (16); always
replace the seal with a new one.
13. Use a vise with soft jaws to hold the displacement
rod (1) by its flats. Place a 15 mm wrench on the
piston flats and unscrew the piston (13) and prim-
ing piston rod (21) from the displacement rod (1).
Remove the piston guide assembly (V) from the
piston (13), and set aside for disassembly later.
6. Unscrew the intake valve housing (16) from the
cylinder (11), using a 24 in. adjustable wrench. Pull
the housing off the pump. The intake check valve
assembly (U) should slide down the priming piston
rod (21) as you remove the housing; if it does not
slide easily, loosen it by firmly tapping the top of
the housing (16) with a rubber mallet. Take care
not to drop the assembly (U) as it comes free. Set
the check valve assembly aside for disassembly
later.
14. It is not necessary to remove the priming piston
rod (21) from the piston (13) unless you see scor-
ing, wear, or other damage to either part. To
disassemble, place the piston flats in a vise. Using
an 8 mm wrench on the rod flats, unscrew the rod.
14
308200
Service
15. To disassemble the piston guide assembly (V),
16. To disassemble the intake check valve assembly
(U), place the nut (27) in a vise and unscrew the
intake valve body (25) from the nut, using a 25 mm
wrench. See Fig. 6. Remove the seal (30) from the
nut (27) and the other seal (26) from the valve
body; always replace them with new ones. Inspect
the mating surfaces of the intake valve body (25)
and seat (18) for wear, scoring, or other damage.
place the flats of the piston seat (15) in a vise.
Close the jaws just tight enough to hold the part; it
can be damaged by squeezing it too tightly. Using
an 8 mm (5/16 in.) dia. brass rod, unscrew the
piston guide (12) from the piston seat (15). See
Fig. 5. Remove the piston seal (14); always re-
place with a new one. Inspect the mating surfaces
of the piston (13) and piston seat (15) for nicks,
scoring or wear.
27
15
Brass
Rod
25
0206
Fig. 6
12
NOTE: The seal (30) is press-fit in the nut (27), and
may require cutting with a razor to ease removal.
0205
Fig. 5
17. Inspect all parts and threads, and clean with a
compatible solvent. To reassemble, see page 17.
308200 15
Service
DETAIL OF THROAT PACKINGS
1
2
4
3
5
9
6
33
8
AA 1
7
3
BB
10
2
DETAIL OF
PISTON CHECK VALVE
11 (REF)
12
11
V (See detail at left.)
16
16 (REF)
14
U (See detail below.)
15
13
10
DETAIL OF
INTAKE CHECK VALVE
17 (REF)
21
20
24
30
27
25
26
17
23
22
1
2
3
Remove.
18
19
Leave installed; clean bleed hole on underside.
Remove only if damaged.
16
308200
Fig. 7
01060
Service
4. Place the outlet housing (9) in a vise. If the bleeder
Reassembly
Refer to Fig. 8 for reassembly.
valve housing (BB) was removed, apply PTFE
tape to the threads and reinstall it in the outlet
housing (9), making sure the bleed hole faces
toward the bottom of the outlet housing. Then
screw the valve plug (AA) fully into the valve
housing (BB).
1. Place an 8 mm (5/16 in.) dia. brass rod lengthwise
in a vise. Install a new piston seal (14*) on the
piston seat (15). Apply thread lubricant to the
threads of the piston guide (12). Place the piston
guide (12) securely on the brass rod. Using a 22
mm crow’s-foot, screw the piston seat (15) into the
piston guide. Torque to 35–41 N.m (26–30 ft-lb).
NOTE: The bleeder valve plug (AA) has two sets of
threads. When reassembling, be sure the plug is fully
screwed into the valve housing (BB).
2. If it was necessary to remove the priming piston
rod (21) from the piston (13), apply thread lubricant
to the female threads of the piston. Place the flats
of the piston (13) in a vise. Hold the flats of the rod
with an 8 mm wrench, and screw the rod into the
piston. Torque to 35-41 N.m (26-30 ft-lb). Be
NOTE: It is not ordinarily necessary to remove the
outlet nipple (7) and o-ring (8*). However, if they were
replaced because of damage, lubricate the o-ring (8*)
and place it on the nipple (7). Screw the nipple into the
outlet housing (9). Torque to 60-84 N.m (44–62 ft-lb).
careful not to create burrs on the flats of the rod.
3. Use a vise with soft jaws to hold the flats of the
displacement rod (1). Install the assembled piston
guide/seat on the piston (13). Apply thread lubri-
cant to the female threads of the piston, and screw
the piston assembly onto the rod, using a 15 mm
wrench on the piston flats. Torque to 35-41 N.m
(26-30 ft-lb). There will be a small gap between the
top of the piston (13) and the shoulder of the rod
(1).
308200 17
Service
5. Lubricate the o-rings (10*) and install them on the
11. Lubricate a new intake valve seal (26*) and slide it
onto the rod, being careful not to damage the seal
when passing over the flats of the rod. Slide the
seal up until it reaches the packing nut (27). Apply
thread lubricant to the female threads of the intake
valve body (25), and slide it onto the rod until it
reaches the nut (27).
cylinder (11). Apply thread lubricant to the top
threads of the cylinder. Using a 24 in. adjustable
wrench on the flats of the cylinder, screw it into the
outlet housing (9). Torque to 159–221 N.m
(117–163 ft-lb).
6. Lubricate the throat packings and glands, and
install them in the outlet housing (9) one at a time
in the following order, with the lips of the v-pack-
ings facing down: male gland (6n), UHMWPE
v-packing (5n), PTFE v-packing (3n), UHMWPE
(5n), PTFE (3n), UHMWPE (5n), and female
gland (4n). Apply thread lubricant to the packing
nut (2) and install it loosely in the outlet housing.
12. Place a 7/8 in. wrench on the hex of the packing
nut (27) and a 25 mm wrench on the flats of the
valve body (25). Screw the nut into the body,
making certain they remain in position above the
flats of the rod (21). Torque to 35–41 N.m (26–30
ft-lb). Slide the assembled intake check valve (U)
up the priming piston rod and into the rod guide
(17) as far as possible; this may be difficult due to
high friction between the seal (26*) and rod (21).
7. Carefully insert the displacement rod (1) into the
bottom of the cylinder (11). Push the rod up into
the cylinder and through the outlet housing (9),
until it protrudes from the packing nut (2). Be
careful not to damage the piston seal (14*) while
performing this step.
13. Position the intake valve seat (18) so its large
beveled side faces down toward the pump intake.
Slide the seat (18) onto the priming piston rod (21)
and into the intake valve housing (16) until it seats
on the rod guide (17) . Lubricate a new seal (19*)
and push it up into the beveled gap around the
bottom outer edge of the seat (18). Be sure the
seal is fully and uniformly positioned in the gap.
8. Apply thread lubricant to the bottom threads of the
cylinder (11). Be sure the o-ring (10*) is in place on
the cylinder. Guide the intake valve housing (16)
up onto the priming piston rod (21). Screw the
valve housing onto the cylinder, using a 24 in.
adjustable wrench. Torque to 159–221 N.m
(117–163 ft-lb).
14. Apply thread lubricant to the threads of the intake
cylinder (20) and screw the cylinder into the intake
valve housing (16), using a 24 in. adjustable
wrench. Torque to 159–221 N.m (117–163 ft-lb).
Installation of the intake cylinder (20) will seat the
parts of the intake valve assembly (U) securely in
the proper position.
9. If the rod guide (17) was removed from the intake
valve housing (16), reinstall it with the open end
facing down toward the pump intake.
15. Slide the priming piston guide (24) onto the rod
(21) until it stops. Then install the priming piston
(23), with the flat side facing up toward the pump.
Apply thread lubricant to the female threads of the
priming piston nut (22). Hold the rod (21) steady
with an 8 mm wrench on the flats, and screw the
priming piston nut (22) onto the rod with a 3/4 in.
wrench. Torque to 35-41 N.m (26-30 ft-lb).
10. With the beveled side facing up, press the seal
(30*) into the recess of the intake packing nut (27)
until it snaps into place. The nose of the seal
should be flush with or slightly recessed into the
face of the packing nut. With the threads facing
down toward the pump intake, slide the nut up
onto the priming piston rod (21) until it clears the
flats of the rod.
16. Reconnect the displacement pump to the air motor
as explained on page 13.
18
308200
Service
DETAIL OF THROAT PACKINGS
1
n4
1
2
3
1
Torque to 35–41 NSm (26–30 ft-lb).
2
If removed, apply PTFE tape to threads.
3n
Bleed hole must face toward bottom of
outlet housing (9).
n5
7
4
5
6
Torque to 159–221 NSm (117–163 ft-lb).
9
Flat side must face up.
n6
3
33
Apply thread lubricant and torque to
35-41 NSm (26-30 ft-lb).
*8
Lips of V–packings must face down.
7
8
BB
2
Remove only if damaged. Torque to
60–84 NSm (44–62 ft-lb).
7
8
9
Apply lubricant to female threads.
Apply lubricant to threads.
AA
10*
10
11
DETAIL OF
PISTON CHECK VALVE
Large bevel must face down.
1 (REF)
11 (REF)
11
4
6
V (See detail at left.)
12
14*
15
9
16
4
1
U (See detail below.)
DETAIL OF
INTAKE CHECK VALVE
9
13
17
10*
*30
16 (REF)
17 (REF)
1 27
1
21
*26
10
20
4
25
24
23
5
18
11
22
6
*19
308200 19
01060
Fig. 8
Parts
Model 222839, Series A
23:1 Ratio Monark Pump
(includes items 101–113)
Ref.
No.
101
Part No. Description
Qty.
101
222791
AIR MOTOR, Monark
1
(see 307043 for parts)
102
103
104
105
106
24B190
184162
184100
184131
109209
KIT, tie rod
ROD, adapter
NUT, coupling
3
1
1
2
3
COLLAR, coupling
NUT, hex, self-locking; with
nylon insert; M10 x 1.5
PUMP, displacement
(see pages 23–22 for parts)
PIN, cotter
SCREW, cap, socket hd;
3/8–16 unc–3a x 0.75” (19 mm)
PLATE, adapter
108
110
107
222814
1
108
109
101946
109212
1
3
109
110
113
184077
184119
1
1
WRENCH, packing nut
105
104
103
102
113
106
107
20
308200
Parts
Model 222907, Series A
46:1 Ratio President Pump
(includes items 101–113)
Ref.
No.
101
Part No. Description
Qty.
101
222772
AIR MOTOR, President
1
(see 306982 for parts)
102
103
104
105
106
24B190
184160
184100
184131
109209
KIT, tie rod
ROD, adapter
NUT, coupling
COLLAR, coupling
NUT, hex, self-locking; with
nylon insert; M10 x 1.5
PUMP, displacement
(see pages 23–22 for parts)
PIN, cotter
3
1
1
2
3
108
103
107
222814
1
108
113
101946
184119
1
1
WRENCH, packing nut
102
105
104
106
113
107
01059
308200 21
Displacement Pump Parts
Model 222814, Series A
Displacement Pump
(includes items 1–33)
2
17
1
30}l
4{n
3{n
27
12
n5
26*l
25l
n{6
9
14}
33
42
15
*8
18
l*19
13
10*
7
21
20
11
21 (REF)
*10
24
23
16
1 (REF)
22
01062B
22
308200
Displacement Pump Parts
Model 222814, Series A Displacement Pump
(includes items 1–42)
Ref.
No.
Ref.
No.
Part No. Description
Qty.
Part No. Description
184438 GUIDE, priming piston; sst
Qty.
1
2
184101
184423
ROD, displacement; sst
NUT, packing; sst
1
1
2
1
3
1
1
24
1
1
1
1
1
25l 184433
26*l 184114
27
VALVE BODY, intake; sst
SEAL, intake valve; PTFE
NUT, packing, intake valve; sst
SEAL, valve; PTFE
3{n 109301
4{n 184171
5n
6{n 184221
7
V–PACKING, PTFE
GLAND, female; sst
V–PACKING, UHMWPE
GLAND, male; sst
184432
109251
30}l 184553
33
42
184392
190293
HOUSING, valve; sst; 3/8–18 npt 1
x 1/2–20 unf–2b
PLUG, valve; sst; 1/2–20 unf–2a
184424
FITTING, outlet; M27 x 1.5(m);
1/2 npt(m); sst
1
8*
9
109450
184422
109451
184106
15K690
184426
184554
184428
184430
184431
184435
O–RING; PTFE
HOUSING, outlet; sst
O–RING, PTFE
CYLINDER, pump; sst
GUIDE, piston; sst
PISTON; sst
SEAL, piston; PTFE
SEAT, piston; sst
HOUSING, intake valve; sst
GUIDE, rod; sst
SEAT, intake valve; sst
SEAL; acetal
CYLINDER, intake; sst
ROD, priming piston; sst
NUT, priming piston; sst
PISTON, priming; sst
2
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
*
These parts are included in Seal Repair Kit 222784,
which may be purchased separately.
10*
11
12
13
14}
15
16
17
18
{ These parts are included in Throat Packing Conver-
sion Kit 222786, which may be purchased sepa-
rately.
n These parts are included in Throat Packing Repair
Kit 222785, which may be purchased separately.
19*l 184296
l These parts are included in Intake Valve Repair Kit
20
21
22
23
184437
184117
184440
184439
222908, which may be purchased separately.
} Keep these spare parts on hand to reduce down
time.
308200 23
Technical Data (222839 Monark)
WARNING
Be sure that all fluids and solvents used are chemically compatible with the
Wetted Parts listed below. Always read the manufacturer’s literature before
using fluid or solvent in this pump.
Category
Data
Maximum fluid working pressure
Maximum air input pressure
4140 psi (29 MPa, 285 bar)
180 psi (1.2 MPa, 12 bar)
130
Pump cycles per 3.8 liters (1 gal.)
Maximum recommended pump speed for continuous
operation
40 cycles/min
Maximum recommended pump speed
Maximum flow at 60 cycles/min
Air motor effective diameter
Stroke length
60 cycles/min
1.74 liters/min (0.46 gpm)
76 mm (3”)
76 mm (3”)
Displacement pump effective area
Maximum pump operating temperature
Air inlet size
2 cm@ (0.310 in.@)
65.5_C (150_F)
3/8 npt (f)
Fluid outlet size
1/2 npt (m)
Weight
19.5 kg (43 lb)
Wetted parts
AISI 304, 316, PH 13–8 MO, and 17–4 PH grades of
Stainless Steel; Chrome; PTFE; Glass–Filled PTFE;
Acetal; Ultra–High Molecular Weight Polyethylene;
Molybdenum Disulfide
24
308200
Technical Data (222839 Monark)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid
flow (lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
To find Pump Air Consumption (m#/min or scfm) at a specific
fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve.
2. Read vertical line up to intersection with selected air consump-
tion curve.
3. Follow left to scale to read fluid outlet pressure.
3. Follow left to scale to read air consumption.
A
B
C
D
180 psi (1.25 MPa, 12.5 bar) air pressure
100 psi (0.7 MPa, 7 bar) air pressure
70 psi (0.49 MPa, 4.9 bar) air pressure
40 psi (0.28 MPa, 2.8 bar) air pressure
A
B
C
D
180 psi (1.25 MPa, 12.5 bar) air pressure
100 psi (0.7 MPa, 7 bar) air pressure
70 psi (0.49 MPa, 4.9 bar) air pressure
40 psi (0.28 MPa, 2.8 bar) air pressure
psi
scfm
m#/min
30
0.84
24
0.672
18
0.504
Fluid Outlet Pressure
Air Consumption
MPa, bar
4000
28, 280
A
B
A
B
3000
21, 210
2000
14, 140
12
0.336
C
D
C
D
1000
7, 70
6
0.168
0
0
0.000
0.120
0.435
0.240
0.870
0.360
1.306
0.000
0.120
0.435
0.240
0.870
0.360
1.306
gpm
liters/minute
gpm
liters/minute
1.741
1.741
FLUID FLOW (TEST FLUID: 1900 CENTIPOISE OIL)
FLUID FLOW (TEST FLUID: 1900 CENTIPOISE OIL)
psi
MPa, bar
4000
scfm
m#/min
30
Fluid Outlet Pressure
Air Consumption
0.84
24
0.672
18
0.504
28, 280
A
A
3000
21, 210
2000
14, 140
B
C
B
C
12
0.336
1000
7, 70
6
0.168
0
0
0.000
0.120
0.435
0.240
0.870
0.360
1.306
0.000
0.120
0.435
0.240
0.870
0.360
1.306
gpm
liters/minute
gpm
liters/minute
1.741
1.741
FLUID FLOW (TEST FLUID: 11,000 CENTIPOISE SEALANT)
FLUID FLOW (TEST FLUID: 11,000 CENTIPOISE SEALANT)
308200 25
Technical Data (222907 President)
WARNING
Be sure that all fluids and solvents used are chemically compatible with the
Wetted Parts listed below. Always read the manufacturer’s literature before
using fluid or solvent in this pump.
Category
Data
Maximum fluid working pressure
Maximum air input pressure
4600 psi (32 MPa, 317 bar)
100 psi (0.7 MPa, 7 bar)
100
Pump cycles per 3.8 liters (1 gal.)
Maximum recommended pump speed for continuous
operation
40 cycles/min
Maximum recommended pump speed
Maximum flow at 60 cycles/min
Air motor effective diameter
Stroke length
60 cycles/min
2.28 liters/min (0.6 gpm) at 60 cycles/min
108 mm (4.25”)
102 mm (4”)
Displacement pump effective area
Maximum pump operating temperature
Air inlet size
2 cm@ (0.310 in.@)
65.5_C (150_F)
1/2 npt (f)
Fluid outlet size
1/2 npt (m)
Weight
21.8 kg (48 lb)
Wetted parts
AISI 304, 316, PH 13–8 MO, and 17–4 PH grades of
Stainless Steel; Chrome; PTFE; Glass–Filled PTFE;
Acetal; Ultra–High Molecular Weight Polyethylene;
Molybdenum Disulfide
26
308200
Technical Data (222907 President)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid
flow (lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
To find Pump Air Consumption (m#/min or scfm) at a specific
fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve.
2. Read vertical line up to intersection with selected air consump-
tion curve.
3. Follow left to scale to read fluid outlet pressure.
3. Follow left to scale to read air consumption.
A
B
C
100 psi (0.7 MPa, 7 bar) air pressure
70 psi (0.49 MPa, 4.9 bar) air pressure
40 psi (0.28 MPa, 2.8 bar) air pressure
A
B
C
100 psi (0.7 MPa, 7 bar) air pressure
70 psi (0.49 MPa, 4.9 bar) air pressure
40 psi (0.28 MPa, 2.8 bar) air pressure
psi
scfm
m#/min
30
Fluid Outlet Pressure
Air Consumption
MPa, bar
5000
0.840
24
0.672
18
0.504
35, 350
4000
28, 280
A
B
A
B
C
3000
21, 210
C
2000
14, 140
12
0.336
1000
7, 70
6
0.168
0
0
0.00
0.15
0.57
0.30
1.14
0.45
1.70
0.60
2.28
0.00
0.15
0.57
0.30
1.14
0.45
1.70
0.60
2.28
gpm
liters/minute
gpm
liters/minute
FLUID FLOW (TEST FLUID: 1900 CENTIPOISE OIL)
FLUID FLOW (TEST FLUID: 1900 CENTIPOISE OIL)
psi
MPa, bar
4000
scfm
m#/min
36
Fluid Outlet Pressure
Air Consumption
1.008
28, 280
A
A
3000
24
21, 210
0.672
B
C
2000
14, 140
B
C
12
0.336
1000
7, 70
0
0
0.00
0.15
0.57
0.30
1.14
0.45
1.70
0.60
2.28
0.00
0.15
0.57
0.30
1.14
0.45
1.70
0.60
2.28
gpm
liters/minute
gpm
liters/minute
FLUID FLOW (TEST FLUID: 11,000 CENTIPOISE SEALANT)
FLUID FLOW (TEST FLUID: 11,000 CENTIPOISE SEALANT)
308200 27
Dimensions
Model 222907 Shown
B
D
A
C
Pump
Model
A
B
C
D
222-839
1147 mm
(45.2 in.)
365 mm
(14.35 in.)
782 mm
(30.8 in.)
328 mm
(12.9 in.)
222-907
1207 mm
(47.5 in.)
418 mm
(16.45 in.)
789 mm
(31.0 in.)
328 mm
(12.9 in.)
01057
28
308200
Mounting Hole Layout
Model 222907 PRESIDENT PUMP
Model 222839 MONARK PUMP
63.5 mm
(2.50”)
54.1 mm
63.5 mm
(2.130”)
(2.50”)
22.2 mm
(0.875”)
62.50 mm
(2.461”)
31.25 mm
(1.230”)
38.5 mm
(1.516”)
31.2 mm
(1.230”)
62.50 mm
(2.461”)
7.1 mm
7.9 mm
(0.281”)
11.4 mm
(0.312”)
diameter (2)
(0.449”)
diameter (2)
diameter (3)
11.4 mm
(0.449”)
diameter (3)
44.5 mm
(1.750”)
54.1 mm
(2.131”)
0213
0214
308200 29
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,
Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be
defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais-
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Phone Numbers
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
1–800–328–0211 Toll Free
612–623–6921
612–378–3505 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 308200
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
Copyright 1992, Graco Inc. is registered to ISO 9001
Revised 12/2008
30
308200
|