GARDENA
WP 700 S
Art. 7851
WP 1500 S Art. 7857
D
Gebrauchsanweisung
Solar-Wasserspielpumpen-Set
GB Operating Instructions
Solar-Powered Fountain Pump Set
F
Mode d’emploi
Pompe solaire pour jets d’eau
NL Gebruiksaanwijzing
Waterspelpompset Solar
S
I
Bruksanvisning
Fontän Pump Set med solcellsdrift
Istruzioni per l’uso
Pompa a energia solare per giochi d’acqua
E
Manual de instrucciones
Set de bomba solar para juegos de agua
DK Brugsanvisning
Solcelledrevet Springvandspumpe Sæt
G
GARDENA Solar-Powered Fountain Pump Set
WP 700 S / WP 1500 S
Welcome to GARDENA aquamotion ...
Please read these operating instructions carefully and observe
the notes given.
Use the instructions to familiarise yourself with the equipment,
the operating controls, their correct use, and the notes on safety.
For safety reasons, children under 16 as well as persons not
familiar with these operating instructions should not use this
pump.
Keep these operating instructions in a safe place.
The Applications Range of Your Pump
Intended purpose
GARDENA Fountain Pumps have been designed for private use.
They are not designed for operating watering tools and systems.
Attention
A GARDENA Fountain Pumps have not been designed for
constant use in the industrial sector.
Corrosive, easily combustible, aggressive or explosive sub-
stances (e.g. petrol, petroleum, nitro thinner) as well as salt-
water or food / drinking water must not be pumped.
A
For Your Safety
Visual check
Before operating the pump, look to see if there is any damage
of the pump. A damaged pump must not be used. In case of
damage, please have the pump checked by our GARDENA
Service Centre or by an authorised electrician.
Do not use power cable
to carry the pump
Do not use the power cable to carry the pump or to pull the plug
out of the socket. Protect the power cable from heat, oil and
sharp edges.
Temperature of the liquid
used
The temperature of the liquid used must not be below 4°C or
above 35°C.
Wear and reduced
output
Sand and other abrasive substances in the liquid cause in-
creased wear and reduce the output of the pump.
Caution!
Low voltage
GARDENA pumps and plug connections have been designed
exclusively for the use with low voltage. When connected
to 230 V your life is at risk! Use the solar panel only to operate
the GARDENA Fountain Pump WP 700 S or WP 1500 S.
Observe local noise
Please observe the local noise prevention regulations.
prevention regulations
11
G
G
Applications:
Operation
Examples – System Extensions – Product Recommendations
Installing the pump
1. Remove the pump from the filter basket and screw the regulator
supplied onto the second opening of the pump up to the limit
stop (➔ max. delivery capacity on the vertical outlet). Then
replace the pump in the filter basket.
Water jets for
26,5 mm (G 3/4) thread
connections
➔ Example for application:
Water jets may be integrated into water features.
2. Put the pump on a stable base to ensure that the upper edge of
the filter tank is completely immersed in water.
Model
Cascade
7814*
Water
Bell
Foaming
Jet Spray Fleur-de-Lis
Water
Water-
fall
Cascade
Rotating
Art.
No.
7816
7818
7820
7822
7823
WP 700 S
7851
7857
×
×
×
×
×
×
×
×
–
×
–
–
Caution: Submersion depth
Assembling the solar panel
Please note the maximum submersion depth (see “Technical Data”).
WP 1500 S
Insert both aluminium poles
into the holes in the side sections
1
3
. Place one of the O-rings
2
on each of the swivel pins
of the
4
* contained in delivery volume
solar panel
then screw both side sections to the solar panel.
5
4
4
➔ Example for application:
To aerate the pond.
Pond aeration
3
Important: when tightening the screws, ensure that you do not
screw them too tight to ensure that the solar panel can still be
easily adjusted.
3
➔ Product:
GARDENA Pond Aerator
Art. No. 7936
Zeolith fulfils the following functions:
Filling the filter tank
with zeolith
2
.
Filters the water (➔ protection for the pump).
1
.
.
.
Bonds with excessive nutrients and causes their decomposition
by bacteria (➔ Ion exchange and the bonding of e.g. nitrate).
Helps to keep the pond clean and maintain the biological
balance.
Positioning the solar panel
Position the solar panel in such a way that it will be exposed
to direct sunlight. No shadow should be cast on it.
The ideal positioning angle is 30° from the vertical.
Provides stability for the pump
A The solar panel must not be positioned near easily flammable
GARDENA Zeolith, 1 l
GARDENA Zeolith, 5 l
Art. No. 7914
Art. No. 7915
substances.
After adjusting tighten the screws firmly.
Note:
To ensure the zeolith functions correctly, we recommend you
replace or clean it every 6 months (e.g. in salt water).
.
Permanent installation
of the solar panel
The solar panel can be permanently installed in an outdoor area.
For this purpose you should attach the appliance to a wall, e.g.
with wooden bolts.
.
Always unplug the pump first before working on it.
Information
.
Before assembling system extensions first unscrew the pre-
.
For permanent installation of the appliance you should ensure
assembled cascade and if necessary also the telescopic tube
of the pump and then screw one of the water jets on again
(➔ the ball-and-socket joint ensures that the water jet is ver-
tical.)
that it is exposed to maximum solar radiation.
.
The special glazing of the solar panel ensures complete protec-
tion against hailstones and other adverse weather conditions.
.
Follow the Safety and Assembly Information attached to the
Starting the pump
Connect the power cable of the pump to the socket of the solar
panel.
operating instructions.
The pump will start as soon as enough energy has been
generated from solar radiation in the solar panel.
12
13
G
G
Avoid dry operation
Avoid dry operation of the pump as dry running will produce
undesirable heat and destroy the pump.
Dismantling
1. Disconnect the plug from the solar panel!
2. Remove the pump from the water.
3. If necessary remove the gravel.
.
Horizontal or
second outlet
Loosen the regulator by turning it anti-clockwise until you
achieve the desired water flow from the vertical pipe of the
fountain/water feature.
4. Pull the pump pointing vertically upwards out of the filter tank.
6
5. Pull the suction filter casing
wards and remove it.
for-
.
1
You may connect other terminals to the second outlet.
For example, a separately installed water jet may be operated
via the GARDENA Fountain/Light Bracket, Art. No. 7886.
If necessary fix the bracket with two screws.
5
6. Remove the foam filter
suction piece of the pump.
7. Turn the pump casing to the left
to the limit stop and then
pull it straight towards the front and
remove it! Do not tilt!
from the
2
4
3
1
3
Information:
2
This significantly reduces the volume of the vertical water jet.
.
If the max. delivery capacity of the second outlet is to be used
8. Pull the feed impeller
out of the
4
then the vertical outlet should be closed with the end cap sup-
plied.
motor casing
.
6
.
Then assemble all the fittings reversing the order and direction
in which they were dismantled. Please take care that the seal
.
Example: Hose pipe connection with the GARDENA
Fountain/Light Bracket
ring
is properly re-fitted.
5
We recommend the use of a 3/4” (19 mm) GARDENA Pond
Hose Pipe, Art. No. 7895, connected to with the GARDENA
“Profi” Maxi-Flow-System with Tap Connector (Art. No. 2801
and 2802) and the GARDENA “Profi” Maxi-Flow-System Hose
Connectors (Art. No. 2817).
➔ Make sure while assembling that you attach the pump casing
with the pressure joint being cated, press it firmly and then
turn it straight to the right.
➔ Observe the markings.
Care Instructions
Storage
Cleaning the filter tank
Filter tank and pump should be free from dirt particles!
Where to store
A The pump should be stored out of the reach of children.
1. Remove the pump from the pond and store away from frost
before the first frost sets in.
2. Clean and check the pump carefully.
3. Store the pump in a container filled with water.
The mains plug must not be submerged.
How to clean:
.
Disconnect the plug from the solar panel!
.
Remove the pump from the water.
.
If necessary remove the gravel.
Clean the pump and the filter using a water jet.
.
.
If there are deposits of dirt inside the pump then dismantle the
casing (➔ see “Dismantling”) and carefully clean the interior
fittings with water.
Information
Information: Do not use any hard objects or strong detergents!
Complaints/Repairs
If you have any problems with your Fountain Pump, please con-
tact our Service or return the defective unit together with a short
description of the problem – in case of guarantee, with the
warranty card duly completed and signed – postage paid to one
of the GARDENA Service Centres listed on the back of this leaflet.
Blocked feed impeller
If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).
Product liability
We expressly point out that, in accordance with the product
liability law, we are not liable for any damage caused by our
units if it is due to improper repair or if parts exchanged are not
original GARDENA parts or parts approved by us, and, if the
repairs were not carried out by a GARDENA Service Centre or
an authorised specialist. The same applies to spare parts and
accessories.
14
15
G
G
Technical Data
Guarantee
Type
WP 700 S
WP 1500 S
GARDENA guarantees this
product for 3 years (from date
of purchase). This guarantee
covers all serious defects
of the unit that can be proved
to be material or manufacturing
faults. Under warranty we will
either replace the unit or repair
it free of charge if the following
conditions apply:
ments of the operating in-
structions. Neither the pur-
chaser nor a non-authorised
third party have attempted
to repair the unit.
In the event of a fault, please
send the defective unit together
with the receipt and a descrip-
tion of the fault, postage paid,
to one of the GARDENA
Service Centres on the back
of this page.
Art. No.
7851
7857
Rated power
Flow
Max. delivery head
Max. submersion depth
Connection cable
Fitting
8 W
12 l/min
1.4 m
17 W
25 l/min
2.1 m
1.0 m
2.0 m
Parts subject to wear (e.g.
feed impeller) are excluded
from this guarantee.
12 V DC
26.5 mm (G 3/4)
male thread
35 °C
12 V DC
26.5 mm (G 3/4)
male thread
35°C
Max. media temperature
Mains voltage
This manufacturer’s guarantee
does not affect the user’s exist-
ing warranty claims against the
dealer/seller.
.
The unit must have been
12-24 V DC
12-24 V DC
handled properly and in
keeping with the require-
1)
Noise level LWA
48 dB(A)
48 dB(A)
Solar panel
Solar cells
monocrystalline
silicium cells
monocrystalline
silicium cells
Cover
shock-resistant
compound glass
10 W at 16.6 V/0.6 A
shock-resistant
compound glass
10 W at 16.6 V/0.6 A
Power
1) Measuring method according to EN 60335-1
EU Certificate of Conformity
The undersigned
GARDENA Kress + Kastner GmbH · Hans-Lorenser-Str. 40 · D-89079 Ulm
hereby certifies that, when leaving our factory, the units indicated below are in accordance with the
harmonised EU guidelines, EU standards of safety and product specific standards.
This certificate becomes void if the units are modified without our approval.
Description of the units:
Solar-Powered Fountain
Pumps
EU directives:
Machinery Directive 98/37/EC
Directive 93/68/EC
Year of CE marking:
1999
Type:
WP 700 S / WP 1500 S
Harmonised
European standards:
EN 292-1
EN 292-2
EN 60335-1
Ulm, 01.06.1999
Art. No.:
7851 / 7857
Thomas Heinl
EN 60335-2-41
Technical Dept. Manager
16
17
Garantiekarte
Solar-Wasserspielpumpen-Set
WP 700 S
❏
❏
Warranty Card
Bon de garantie
Garantiekaart
Solar-Powered Fountain Pump Set
Pompe solaire pour jets d’eau
WP 1500 S
Waterspelpompset Solar
Garantikort
Fontän Pump Set med solcellsdrift
Pompa a energia solare per giochi d’acqua
Set de bomba solar para juegos de agua
Solcelledrevet Springvandspumpe Sæt
Certificato di garanzia
Tarjeta de garantía
Garantibevis
Wurde gekauft am:
Was purchased on:
Achetée le (date et lieu d’achat) :
Werd gekocht op:
Försäljningsdatum:
Data di acquisto:
Händlerstempel
Dealer’s stamp/Receipt
Cachet du revendeur
Stempel van de handelaar
Återförsäljarens stämpel
Timbro del rivenditore
Sello del comerciante
Firmastempel
Fecha de compra:
Købsdato:
Beanstandung:
Reasons for complaint:
Défaut constaté :
Klacht:
Reklamation:
Reclamo:
Reclamación:
Reklamation:
59
Deutschland
GARDENA Kress + Kastner GmbH
GARDENA Service
Hans-Lorenser-Straße 40
D-89079 Ulm
Produktfragen: (0731) 490-123
Reparaturen: (0731) 490-290
Finland
Norway
Habitec Oy
GARDENA Norge A/S
Postboks 214
2013 Skjetten
Martinkyläntie 52
01720 Vantaa
France
Poland
GARDENA France
Service Après-Vente
BP 50080
GARDENA Polska Sp. z o.o.
Szymanów 9 d
Argentina
05-532 Baniocha
Argensem S.A.
95948 ROISSY CDG Cedex
Portugal
Venezuela 1075
Great Britain
MARKT (Portugal), Lda.
Recta da Granja do Marquês
Edif. GARDENA
(1618) El Talar - Buenos Aires
GARDENA UK Ltd.
27-28 Brenkley Way
Blezard Business Park
Seaton Burn
Australia
NYLEX Corporation Ltd.
25-29 Nepean Highway
P.O. Box 68
Algueirão
2725-596 Mem Martins
Newcastle upon Tyne
NE13 6DS
Russia / Россия
АО АМИДА ТТЦ
Mentone, Victoria 3194
Austria
Greece
ул. Моcфилмовcкая 66
117330 Моcква
GARDENA Österreich Ges. m.b.H. Agrokip G. Psomadopoulos & Co.
Stettnerweg 11-15
2100 Korneuburg
20, Lykourgou str.
Kallithea - Athens
Singapore
Variware
Belgium
Hungary
Holland Road Shopping Centre
227-A 1st Fl., Unit 29
Holland Avenue
Singapore 1027
MARKT (Belgium) NV/SA
Sterrebeekstraat 163
1930 Zaventem
GARDENA Magyarország Kft.
Késmárk utca 22
1158 Budapest
Brazil
Iceland
Heimilistaeki hf
Saetun 8
P.O. Box 5340
125 Reykjavik
Slowenia / Croatia
Silk d.o.o. Trgovina
Brodišče 15
M. Cassab
Av. das Nações Unidas, 20.882
Santo Amaro, CEP 04795-000
São Paulo - S.P.
1236 Trzin
South Africa
Bulgaria / България
ДЕНЕКС ООД
бул. „Черни връх“ 43
София 1407
Republic of Ireland
Michael McLoughlin & Sons
Hardware Limited
Long Mile Road
GARDENA South Africa (Pty.) Ltd.
P.O. Box 11534
Vorna Valley 1686
Spain
Dublin 12
Canada
ANMI Andreu y Miriam S.A.
Calle Pere IV, 111
08018 Barcelona
GARDENA Canada Ltd.
100, Summerlea Road
Brampton, Ontario
Canada L6T 4X3
Italy
GARDENA Italia S.r.l.
Via Donizetti 22
20020 Lainate (Mi)
Sweden
GARDENA Svenska AB
Box 9003
Chile
Japan
Antonio Martinic Y CIA. LTDA.
Gilberto Fuenzalida 185 Loc.
Las Condes - Santiago de Chile
KAKUDAI Mfg. Co. Ltd.
1-4-4, Itachibori Nishi-ku
Osaka 550
20039 Malmö
Switzerland
GARDENA Kress + Kastner AG
Bitziberg 1
Costa Rica
Luxembourg
Magasins Jules Neuberg
Grand Rue 30
Case Postale No. 12
Luxembourg 2010
Compania Exim
Euroiberoamericana S.A.
350 Sur del Automercado
Los Yoses
8184 Bachenbülach
Ukraine / Украина
АОЗТ АЛЬЦЕСТ
ул. Гайдара 50
г. Киев 01033
San Pedro
Netherlands
Cyprus
MARKT (Holland) BV
Postbus 219
Turkey
FARMOKIPIKI LTD
P.O. Box 7098
74, Digeni Akrita Ave.
1641 Nicosia
Dost Diþ Ticaret Mümessillik A.Þ.
Yeþilbaðlar Mah. Baþkent
Cad. No. 26
Pendik - Ýstanbul
USA
GARDENA
1380 AE Weesp
Neth. Antilles
Jonka Enterprises N.V.
Sta. Rosa Weg 196
P.O. Box 8200
Czech Republic
GARDENA spol. s.r.o.
Ripská 20
Curaçao
3085 Shawnee Drive
Winchester, VA 22604
62700 Brno
New Zealand
NYLEX New Zealand Limited
Private Bag 94001
South Auckland Mail Centre
10 Offenhauser Drive
East Tamaki, Manukau
Denmark
GARDENA Danmark A/S
Naverland 8
7851-20.960.05/0001
GARDENA Kress + Kastner GmbH
Postfach 27 47, D-89070 Ulm
http://www.gardena.de
2600 Glostrup
|