Review the following examples to ensure a trouble free  
installation using the duct cover accessory.  
DUCT COVER REQUIREMENTS  
These decorative duct covers are designed to conceal  
8 ft. Ceiling  
the ductwork running from the top of the hood to the  
ceiling. The duct cover can be used to fill a 12" space by  
using the outer piece alone, or using both pieces it will  
expand from 24" to 34" heights. Read this page to be  
sure the duct cover accessory fits your installation  
situation.  
8 ft. Ceilings: The hood must  
be installed at 30above the  
cooking surface (or 66above  
12"  
the floor). The duct cover will  
not fit if the hood is installed at  
a lower or higher height. Use  
the outside 12section, discard  
the inside section.  
Duct Cover Accessory:  
• Use the decorative duct  
cover to conceal ductwork  
running from the top of  
the hood to the ceiling.  
30"  
9 ft. Ceiling  
12"  
• The duct cover accessory  
consists of 2 pieces. The  
24"  
30"  
outside piece is 12high,  
the inside piece is 22.  
Nested together they are  
24min., expanding to  
a total maximum height  
of 34.  
22"  
12"  
30"  
24"  
• The outside piece can be  
used alone to fill a 12″  
height.  
• For heights over 12, the  
ceiling bracket must be  
12"  
9 ft. Ceilings: Install the hood 24min. and up to a maximum of 30″  
above the cooking surface. The duct cover will expand to reach  
ceiling height.  
11"  
10 ft. Ceiling  
installed to secure the cover at the top.  
30"  
34"  
To avoid unsightly gaps, plan the hood installation height  
for duct cover use.  
• The cover will fit a 12min. height from the top of the  
hood to the ceiling,  
– or 24min. and expanding up to 34from the top of  
the hood to the ceiling.  
36" Max.  
32"  
THE DUCT COVER CANNOT BE USED WHEN THE  
DISTANCE ABOVE THE TOP OF THE HOOD IS  
BETWEEN 12AND 24.  
10 ft. Ceilings: Install the hood 32min. to 36max. above the cooking  
surface. The duct cover will expand to a maximum of 34above the  
top of the hood to meet the ceiling.  
 

Dyson Fan AM 01 User Manual
Dyson Vacuum Cleaner DC08 User Manual
Echo Bear Cat Chipper CH4540 73454 User Manual
Electro Voice Speaker EVID User Manual
Fujitsu All in One Printer DL3300 User Manual
Furuno SONAR ch250s User Manual
Gardena Lawn Mower 36 A Li User Manual
Garmin Headphones VIB10 11 User Manual
GE Mouse HO97663 User Manual
Gigabyte Network Router GN BR01G User Manual