GE Printer CBR PB3 WD User Manual

Kalatel CBR-PB3-WD ProBridge  
Receipt Printer Interface  
Product Overview & Installation Manual  
 
Table of Contents  
1
CBR-PB3-WD ProBridge.................................................. 5  
1.1  
Kalatel CBR-PB3-WD Description......................................................5  
Additional Equipment Provided by the Installer...................................5  
Compatibility.....................................................................................5  
Disclaimer.........................................................................................5  
1.2  
1.3  
1.4  
2
Before You Begin........................................................... 6  
2.1  
Installation Summary.........................................................................6  
How to Use this Manual.....................................................................6  
Kalatel Components:.........................................................................6  
Installation Environment ....................................................................7  
Power...............................................................................................7  
2.2  
2.3  
2.4  
2.5  
3
4
5
ProBridge Diagram......................................................... 9  
Connection Diagram.................................................... 11  
Detailed Installation Steps.......................................... 13  
5.1  
5.2  
PB3 Physical Installation................................................................. 13  
Configuring the PB3 for POS Interface............................................. 14  
6
Special Functions ........................................................ 16  
6.1  
6.2  
6.3  
Display Memory.............................................................................. 16  
Demo (Simulated Message) Mode................................................... 16  
Reset – Clear Memory .................................................................... 17  
7
8
9
Troubleshooting........................................................... 19  
Text to Camera Address.............................................. 21  
Manual Switch Config.................................................. 23  
9.1  
Manual Dipswitch Settings Available................................................ 23  
9.1.1 Baud Rate ...................................................................................... 23  
9.1.2 Protocol.......................................................................................... 24  
10 HyperTerminal Setup................................................... 26  
10.1 Equipment Required ....................................................................... 26  
10.2 Setting up the ProBridge for HyperTerminal Operation ................... 27  
10.3 Manual HyperTerminal Configuration............................................... 28  
11 PB3-POS with DVMRe-CD/CS Units.............................. 31  
11.1 DVMRe-CS/CD Setup..................................................................... 31  
Kalatel CBR-PB3-WD  
3
0150-0261A  
 
12 Cable Specifications.................................................... 33  
13 Specifications.............................................................. 35  
14 Warranty and Service .................................................. 36  
14.1 Factory Service............................................................................... 36  
14.2 Warranty......................................................................................... 36  
Kalatel CBR-PB3-WD  
4
0150-0261A  
 
1CBR-PB3-WD ProBridge  
1.1 Kalatel CBR-PB3-WD Description  
The Kalatel CBR-PB3-WD is a specific ProBridge unit for interfacing the DVMRe  
family of digital video multiplex/recorders Wayne Plus Receipt Printers (WP/RJ).  
One CBR-PB3-WD is required per cash register. Where multiple cash registers  
are connected to a single DVMRe unit, the individual CBR-PB3-WD’s are  
interconnected via the PB3’s built-in RS-485 network.  
1.2 Additional Equipment Provided by the  
Installer  
Installations requiring multiple CBR-PB3-WD units are interconnected via the  
unit’s built-in RS-485 network, the installer will need to provide suitable length  
RS-485 cable terminated with RJ-45 connectors.  
1.3 Compatibility  
The CBR-PB3-WD is compatible with the following DVMRe products:  
DVMRe Type  
DVMRe-CD/CS  
Software Version  
V 3.07 (and above)  
V 3.20 (and above)  
V 4.0 (and above)  
V 4.03 (and above)  
V 4.06 (and above)  
PPC Version  
V 3.07 (and above)  
DVMRe-eZ  
V 3.14 (and above)  
DVMRe-CT (Triplex)  
DVMRe-eZT (Triplex)  
StoreSafe Advanced  
N/A  
N/A  
N/A  
To verify the software version in your unit, either note the display which identifies  
the version when the unit boots-up, or view the version information by clicking the  
About box in the unit’s menu system.  
1.4 Disclaimer  
The Kalatel ProBridge components identified within this document provide means  
of capturing transaction text/data for use by the DVMRe family of digital video  
recording/transmission products. The ProBridge components translate the data  
into a usable format by the DVMRe and permits associating transaction data with  
specific cameras. Kalatel assumes no responsibility for the amount and type of  
information available, the operation, non-operation or erroneous operation of the  
customer provided equipment the ProBridge connects to.  
Kalatel CBR-PB3-WD  
5
0150-0261A  
 
2Before You Begin  
2.1 Installation Summary  
The basic steps to install the CBR-PB3-WD unit are:  
1. Connect the PB3 to the Receipt Printer using the supplied cable. (If  
more than two PB3 units are used, verify that proper termination is set  
on each individual PB3 unit.  
2. Connect the PB3 to the DVMRe-CT/eZT/StoreSafe unit using the  
supplied cable (RJ45-to-RJ45). (If your unit is a DVMRe-CD/CS, the  
required interconnect cable is also provided (RJ45-to-DB9 - see Section  
11 for the specific requirements for the DVMRe-CD/CS).  
3. On each PB3, set the Camera ID switches for each PB3 that is to be  
associated with a specific camera.  
4. Program the DVMRe unit to record in the way desired to meet your  
specific sites.  
2.2 How to Use this Manual  
We recommend that at least the following pages be reviewed before attempting  
an installation.  
q
q
q
ProBridge 3 Diagram on page 9.  
Connection Diagram on page 11.  
Installation & Configuration on pages 13-15.  
2.3 Kalatel Components:  
(1) CBR-PB3-WD ProBridge includes:  
·
·
(1) CBR-PB3-WD ProBridge unit.  
(1) P/N 4310-0034B: RJ45 to RJ45 cable. Connects the ProBridge to  
RS-485 Network. This cable is 6’ in length.  
·
·
(1) P/N 4310-0047B: RJ45 to DB9F cable. Connects the ProBridge to  
the DVMRe. This cable is 6’ in length.  
(1) P/N 4310-0078A: DB9F to DB9M to DB9F ‘Y’ cable. Connects the  
ProBridge to the Electronic Cash Register (ECR) and the Receipt  
Printer This cable is 6’ in length.  
·
·
(1) P/N 4010-0007: 12VDC 120VAC Power Supply or  
(1) P/N 4010-0008: 12VDC 220VAC Power Supply.  
(1) P/N 0150-0261A: Product Overview and Installation Manual.  
Kalatel CBR-PB3-WD  
6
0150-0261A  
 
2.4 Installation Environment  
Power: Ensure that the installation site’s AC power is stable and within the rated  
voltage of the external power supply. If the site’s AC power is likely to have  
spikes or dips, use power line conditioning or an Uninterruptible Power Supply.  
Temperature: Observe the unit’s ambient temperature specifications when  
choosing a location for the unit. Extremes of heat or cold beyond the specified  
operating temperature limits may cause the unit to fail. Do not install this unit on  
top of other hot equipment.  
Moisture: Do not expose the unit to rain or moisture. Moisture can damage  
internal components. Do not install this unit near sources of water.  
RS-232 Limitations: Cable length between the POS device and the ProBridge is  
limited to 50’. Cable length between the ProBridge unit and the DVMRe is also  
limited to 50’. If the supplied cables are replaced by custom made cables to  
address distances between components, ensure the cable is manufactured to  
ANSI standards for RS-232 communication.  
RS485 Limitations: If multiple PB3 units are connected to a single DVMRe unit,  
the distance between the first and last ProBridge unit is limited to 3,000 feet (RS-  
485 communications).  
2.5 Power  
The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use  
any other power supply with this product. The manufacturer accepts no  
responsibility for damage caused by the use of any other power supply.  
Make sure installation is complete and all connections are made before applying  
power to the unit.  
4310-0007 120VAC Power Supply  
Power Supply Input  
Voltage: 120 Volt AC  
Tolerance: ±10%  
Frequency: 60 Hz  
Power Supply Output  
Voltage: 12 Volt DC  
Current: 110mA  
Power: 1.3 Watts  
Connector: 2.1mm female barrel. Center Positive  
Kalatel CBR-PB3-WD  
7
0150-0261A  
 
4310-0008 220VAC Power Supply  
Power Supply Input  
Voltage: 220 Volt AC  
Tolerance: ±10%  
Frequency: 50 Hz  
Power Supply Output  
Voltage: 12 Volt DC  
Current: 110mA  
Power: 1.3 Watts  
Connector: 2.1mm female barrel. Center Positive  
Kalatel CBR-PB3-WD  
8
0150-0261A  
 
3ProBridge Diagram  
SW1  
Dipswitch 1-8  
Port 1  
RS232 Connection  
to Triplex/DVMRe  
or PC  
SW2  
Dipswitch 1-8  
SW3  
Dipswitch 1-8  
Port 0  
RS485 Network Bus  
If multiple PB3s are  
connected together  
(use either connector)  
SW4  
Dipswitch 1-8  
Port 2  
Connects to ECR  
and Receipt Printer  
Power Supply  
Connector 12VDC  
Port 0 and Port 1 each have identical looping RJ45  
connectors.  
NOTE  
Dipswitch Position Legend  
Kalatel CBR-PB3-WD  
9
0150-0261A  
 
Default (Factory) Dipswitch Settings  
SW1  
SW2  
Down  
SW3  
Down  
SW4  
1
2
3
4
5
6
7
8
Up  
Up  
Up  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Up  
Up  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Down  
Up  
Down  
Up  
Up  
Up  
Up  
Up  
Down  
Up  
Up  
The default camera assignment is for the PB3’s transaction information to be  
associated with Camera 1.  
Important Switch Assignments  
SW1  
Dipswitch 1-4 Special Functions (see Section 6)  
Dipswitch 5-8 Camera Assignment  
SW2  
Dipswitch 1  
Reserved  
Dipswitch 2-4 Baud Rate  
Dipswitch 5-8 Protocol  
SW3  
SW4  
Dipswitch 1-8 Receipt Printer Device Select  
Dipswitch 3  
ProBridge Termination  
Kalatel CBR-PB3-WD  
10  
0150-0261A  
 
4Connection Diagram  
ECR  
Receipt  
Printer  
CBR-PB3-WD  
DB9M  
RJ45 (Port 0)  
DB9F  
DB9F  
4310-0078A Cable  
ECR  
Receipt  
Printer  
CBR-PB3-WD  
DB9M  
RJ45 (Port 1)  
4310-0034B Cable  
RJ45 (Port 0)  
DB9F  
4310-0078A Cable  
DB9F  
RS232 Port 2  
DVMRe Triplex  
If the distance between the nearest register PB3 is  
greater than 50’ (RS-232 distance limitation), an  
additional PB3 can be added near the DVMRe  
allowing RS-485 communication between the PB3  
units. If there are more than (2) two PB3’s required  
per installation, please verify proper termination.  
NOTE  
Kalatel CBR-PB3-WD  
11  
0150-0261A  
 
Termination Switch  
Termination is set on SW4 for PORT 0 (Dipswitch #3)  
Termination is important whenever multiple PB3  
units are interconnected via the unit’s built-in RS-  
485 network. The default termination setting on the  
ProBridge 3 unit is with termination set to ON.  
Whenever there are more than two PB3’s,  
termination on some of the PB3 units will change. The first PB3 and the last  
PB3 on the RS-485 network will have termination set to ON (Down), all  
others between these two units will have their termination set to OFF (Up).  
Sample Systems Termination:  
Kalatel CBR-PB3-WD  
12  
0150-0261A  
 
5Detailed Installation  
Steps  
5.1 PB3 Physical Installation  
1. Disconnect the existing Receipt Printer cable from the back of the POS  
system and install the ECR Interconnect Cable (4310-0078A) to the  
Receipt Printer as shown on page 11.  
2. Reconnect the Receipt Printer Cable to one of the D9F connectors on  
the ECR Interconnect Cable as shown  
on page 11.  
3. Connect the other end (DB9F) to the DB9M connector on the PB3 unit.  
4. Connect the PB3 Power Supply to the unit.  
If only one (1) PB3 unit (one cash register) is to be connected, skip to Step 8  
below.  
5. If more than one cash register interface is to be installed repeat steps 1-  
4 above for each additional cash register.  
6. Connect each PB3 unit together by using an RS-485 cable with RJ-45  
connectors on each end. Connect to either receptacle on Port 0 to  
interconnect the PB3 units using an “in” and “out” method. (For details  
on the RS-485 cable, review the cable specifications in Section 13).  
Note: This cable shall be provided by the installer.  
7. Confirm that each PB3 has the proper termination setting per the  
instructions on page 12.  
8. Connect all ECR cameras to their associated inputs on the DVMRe unit  
(ECR#1 = Camera 1 Input, ECR#2 = Camera 2 Input….)  
9. Connect the PB3 closest to the DVMRe using the supplied cable (4310-  
0043B) from Port 1 (RJ45 outer receptacle) of the PB3 to the RS232/2  
port on the DVMRe unit.  
Kalatel CBR-PB3-WD  
13  
0150-0261A  
 
5.2 Configuring the PB3 for POS Interface  
1. Associating ECR data to a specific camera.  
Dipswitches 5-8 on SW1 are used for assigning an  
ECR’s transaction text to a specific camera.  
Please refer to Section 8 for the specific dipswitch  
camera assignments. The default setting is for  
switches 5-8 to be all OFF (All switches Up =  
Camera 1).  
2. Program the DVMRe for the desired recording functions based upon  
the presence of transaction text. In addition make sure the RS-232 port  
on the DVMRe is configured correctly set via the DVMRe Setup Menus:  
a. COMMUNICATIONS>RS-232>PORT (1 OR 2)>19200  
i. Port 2 is used if DVMRe-CT/eZT/StoreSafe  
ii. Port 1 is used if DVMRe-CS/CD/eZ  
Transaction text is captured with video regardless of the  
recording mode (Time-Lapse, Time-Lapse + Event, or Event  
NOTE  
Only). If Time-Lapse + Event or Event Only recording  
modes must have at least one (1) second set for the pre-  
event duration.  
3. Process several POS transactions at the Cash Register.  
a. To verify proper operation with a DVMRe-CT/eZT/StoreSafe  
unit:  
i. Select full-screen on the Main Monitor (A) the camera  
associated with a PB3 unit. Press the camera button  
until the text box window appears in the display.  
ii. The text box will display any transaction data as it is  
passed to the PB3 unit from the POS device. Be  
aware that some POS devices only send transaction  
data until the end of the transaction (when the receipt  
is printed).  
Kalatel CBR-PB3-WD  
14  
0150-0261A  
 
iii. If the unit fails to display transaction text, please go to  
the troubleshooting section of this manual.  
b. To verify proper operation using a DVMRe–CS/CD/eZ, please  
refer to Section 11.  
Kalatel CBR-PB3-WD  
15  
0150-0261A  
 
6Special Functions  
If these settings are used, they must be turned off before normal  
transaction processing will resume.  
NOTE  
6.1 Display Memory  
This setting displays all internal memory settings through Port 1 on the text box  
window of the selected camera on a DVMRe Triplex. This allows you to quickly  
check what settings are in your unit.  
To access this mode:  
SW1  
1
2
3
4
Down  
Down  
Up  
Up  
To exit this mode, return the dipswitches to the following position:  
SW1  
1
2
3
4
Up  
Up  
Up  
Up  
6.2 Demo (Simulated Message) Mode  
This setting permits the PB3 to send a simulated ATM transaction message to  
the DVMRe/Triplex. This is useful for either for troubleshooting or for  
demonstrating PB3 functionality without having an ATM connected.  
Kalatel CBR-PB3-WD  
16  
0150-0261A  
 
As a troubleshooting tool, this element allows you to verify that the PB3 is able to  
send messages and have the DVMRe correctly capture data coming from the  
PB3. In this mode, if text can be received and displayed, yet when attempting to  
process ECR data fails, then some other problem exists with respect to the ECR  
connection (cabling) or interface setup.  
To access this mode:  
SW1  
1
2
3
4
Down  
Down  
Up  
Down  
To exit this mode return the dipswitches to the following position:  
SW1  
1
2
3
4
Up  
Up  
Up  
Up  
6.3 Reset – Clear Memory  
This is primarily a troubleshooting tool that allows the user to clear the non-  
volatile memory of all settings. This will restore all factory defaults as a first step  
to reconfiguring the unit.  
To access this mode:  
SW1  
1
2
3
4
Down  
Down  
Down  
Down  
Kalatel CBR-PB3-WD  
17  
0150-0261A  
 
To exit this mode return the dipswitches to the following position:  
SW1  
1
2
3
4
Up  
Up  
Up  
Up  
Power must be cycled OFF and then ON to the ProBridge unit before  
the reset command will take effect.  
NOTE  
Kalatel CBR-PB3-WD  
18  
0150-0261A  
 
7Troubleshooting  
If you are unable to verify capture of transaction text, do the following:  
1. Check that each device is properly powered.  
2. Check that the ECR to Camera address is correctly programmed SW1.  
3. Check that all cables and cable connections are correct  
4. If data is being displayed but is not intelligible, the likelihood is that the  
baud rate is different than the default value for the selected register.  
Check with the baud rate settings for the Receipt Printer on your POS  
system.  
To change the Baud Rate, the available settings are controlled via the  
dipswitch settings on SW2 (dipswitches 2-4).  
Legend:  
Up (Off) = U  
Down (On) = D  
SW2  
Switch Setting  
Baud Rate  
2
3
4
Port 2  
1200  
2400  
4800  
9600  
14.4k  
19.2k  
38.4k  
U
U
U
U
D
D
D
U
U
D
D
U
U
D
U
D
U
D
U
D
U
5. If the DVMRe is not receiving data at all, you can use a built-in  
demonstration text message to verify that the PB3 is passing data to the  
DVMRe (see Section 6.2 for demo mode).  
a. Remember to return the dipswitches to the normal mode  
(Demo mode off).  
6. If you are still unable to get the Interface to work, please contact Kalatel  
Technical Support.  
Kalatel CBR-PB3-WD  
19  
0150-0261A  
 
7. Section 4 contains all of the default Jumper Settings, if it is necessary  
for you to manually configure the interface.  
Troubleshooting Guide  
Problem  
Solution  
Red LED is not  
illuminated  
Check to make sure the power transformer is plugged  
in properly.  
Replace power transformer.  
Cannot display  
demo text  
Make sure the Triplex is showing the text box on  
Monitor A.  
Dip switch setting should be SW1: ON ON OFF ON  
Check that the serial cable is plugged into Port  
RS232/2 on the Triplex and Port 1 of the PB3 with the  
RJ45 to RJ45 cable (4310-0034B).  
Ensure the baud rate for Port 2 (RS232) on the Triplex  
is set to 19200 bps.  
Ensure camera addresses are set correctly.  
Check cable connection.  
Cannot connect  
with HyperTerminal  
Ensure the computers com port is enabled in the  
system bios and Windows control panel.  
Verify HyperTerminal’s communication settings are  
19200, 8, N, 1, no flow control.  
Kalatel CBR-PB3-WD  
20  
0150-0261A  
 
8Text to Camera Address  
This section contains dipswitch settings for associating a  
specific Cash Register’s transaction text with a specific  
camera on the DVMRe unit.  
SW1 - Dipswitches 5-8  
Dipswitches 5 thru 8 on SW1 assigns transaction text for that cash register’s  
PB3 unit to a specific camera on the DVMRe.  
Legend:  
Off = (Up)  
On = (Down)  
SW1  
Dipswitch 5- 8  
Camera Assignment  
Dipswitch Numbers  
Camera #  
5
6
UP  
7
8
1
2
UP  
UP  
UP  
UP  
UP  
UP  
DOWN  
UP  
3
UP  
UP  
DOWN  
DOWN  
UP  
4
UP  
UP  
DOWN  
UP  
5
UP  
DOWN  
DOWN  
DOWN  
DOWN  
UP  
6
UP  
UP  
DOWN  
UP  
7
UP  
DOWN  
DOWN  
UP  
8
UP  
DOWN  
UP  
9
DOWN  
DOWN  
DOWN  
10  
11  
UP  
UP  
DOWN  
UP  
UP  
DOWN  
Kalatel CBR-PB3-WD  
21  
0150-0261A  
 
SW1  
Dipswitch 5- 8  
Camera Assignment  
Dipswitch Numbers  
Camera #  
5
6
7
8
12  
13  
14  
15  
16  
DOWN  
DOWN  
DOWN  
DOWN  
DOWN  
UP  
DOWN  
UP  
DOWN  
UP  
DOWN  
DOWN  
DOWN  
DOWN  
UP  
DOWN  
UP  
DOWN  
DOWN  
DOWN  
Kalatel CBR-PB3-WD  
22  
0150-0261A  
 
9 Manual Switch Config  
Manual configuration should only be used if the “POS Device Selection” does  
not conform to your specific device because baud rates or protocols are  
slightly different than the default values for the selected device.  
9.1 Manual Dipswitch Settings Available  
q
Camera Address (SW1 – Dipswitches 5-8)  
– see Section 8  
q
q
Baud Rate (SW2 – Dipswitches 2-4)  
Protocol (SW2 – Dipswitches 5-8)  
9.1.1  
Baud Rate  
Legend:  
Up (Off) = U  
Down (On) = D  
SW2  
Switch Setting  
Baud Rate  
2
3
4
Port 2  
1200  
2400  
4800  
9600  
14.4k  
19.2k  
38.4k  
U
U
U
U
D
D
D
U
U
D
D
U
U
D
U
D
U
D
U
D
U
Kalatel CBR-PB3-WD  
23  
0150-0261A  
 
9.1.2  
Protocol  
Legend:  
Up (Off) = U  
Down (On) = D  
SW2  
Switch Setting  
5
6
7
8
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
Protocol: Asynchronous  
Parity: Even  
U
D
U
D
Code: 8-Bit ASCII  
Mode: 1 Stop Bit  
Protocol: Asynchronous  
Parity: Odd  
U
U
U
U
U
D
U
U
U
U
U
D
D
U
U
U
D
U
D
U
Code: 8-Bit ASCII  
Mode: 1 Stop Bit  
Protocol: Asynchronous  
Parity: None  
Code: 8-Bit ASCII  
Mode: 1 Stop Bit  
Protocol: Asynchronous  
Parity: Even  
Code: 7-Bit ASCII  
Mode: 1 Stop Bit  
Protocol: Asynchronous  
Parity: Odd  
Code: 7-Bit ASCII  
Mode: 1 Stop Bit  
Protocol: Asynchronous  
Parity: None  
Code: 7-Bit ASCII  
Mode: 1 Stop Bit  
Kalatel CBR-PB3-WD  
24  
0150-0261A  
 
SW2  
Switch Setting  
5
6
7
8
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
Protocol: Asynchronous  
Parity: Even  
D
U
D
D
Code: 8-Bit ASCII  
Mode: 2 Stop Bit  
Protocol: Asynchronous  
Parity: Odd  
D
D
D
U
U
U
U
U
D
D
D
U
U
D
D
U
D
U
D
U
Code: 8-Bit ASCII  
Mode: 2 Stop Bit  
Protocol: Asynchronous  
Parity: None  
Code: 8-Bit ASCII  
Mode: 2 Stop Bit  
Protocol: Asynchronous  
Parity: Even  
Code: 7-Bit ASCII  
Mode: 2 Stop Bit  
Protocol: Asynchronous  
Parity: Odd  
Code: 7-Bit ASCII  
Mode: 2 Stop Bit  
Protocol: Asynchronous  
Parity: None  
Code: 7-Bit ASCII  
Mode: 2 Stop Bit  
Kalatel CBR-PB3-WD  
25  
0150-0261A  
 
10 HyperTerminal Setup  
Manual configuration can also be completed using Windows HyperTerminal in  
lieu of the dipswitches. Manual configuration should only be used if the “POS  
Device Selection” does not conform to your specific device because baud  
rates or protocols are slightly different than the default values for the selected  
device.  
10.1 Equipment Required  
q
(1) Windows 98/NT/2000/XP Desktop or Laptop PC.  
(1) DB9F to RJ45 cable (included with your unit).  
q
Configuration using Windows HyperTerminal uses  
the supplied RJ45-to-DB9 cable provided with  
your unit. Disconnect the PB3 unit from the  
DVMRe and hook-up the cable as follows:  
The RJ45 end connects to the outside receptacle  
of Port 1 of the PB3 unit and the DB9 end  
connects to your PC’s COM Port (typically  
COM1).  
IMPORTANT: If you program the ProBridge via  
HyperTerminal you must BACKUP (Save) the  
program information via the BACKUP option so that  
everytime the unit is powered up, the settings you  
configured will be used.  
NOTE  
Kalatel CBR-PB3-WD  
26  
0150-0261A  
 
10.2 Setting up the ProBridge for  
HyperTerminal Operation  
1. Start HyperTerminal and open a new Connection (FILE>NEW):  
Give the connection a name and select  
an Icon.  
Click OK.  
2. Under “Connect Using” option  
select “COM1”.  
3. The Com1 Properties menu will  
appear. Select the following  
settings to complete the setup:  
a. Bits per Second = 19200  
b. Data Bits = 8  
c. Parity = None  
d. Stop Bits = 1  
e. Flow Control = None  
4. Power up the ProBridge unit by  
plugging in the power supply.  
Kalatel CBR-PB3-WD  
27  
0150-0261A  
 
10.3 Manual HyperTerminal Configuration  
q
The configurable settings are:  
o
o
o
o
o
o
Protocol  
Baud Rate  
Parity  
# of Stop Bits  
Charcter Set  
POS Device Type  
1. The following screen (or similar) will confirm that you are in HyperTerminal  
programming mode.  
Initializing from DIP  
Switches  
Kalatel ProBridge III POS  
Ver: 2.10  
Camera: 16  
2. Once HyperTerminal mode is set up, press the “Enter” key twice. The  
following menu will appear:  
Main Menu  
1. Exit  
2. Port #2  
3. Backup  
To make a menu selection, enter the number of the element and press  
“Enter”.  
For example:  
Input the following  
2
ENTER  
(Port #2)  
Kalatel CBR-PB3-WD  
28  
0150-0261A  
 
3. Setup Option 2 (Port #2)  
Port #2 is an RS-232 port that connects the PB3 unit to the Receipt Printer  
Interconnect Cable. The settings will vary based upon the type of Receipt  
Printer in use.  
Once you have selected this option, there will be multiple selections  
available for each element. Entering the number for the element will switch  
to the next option for that element. Continue to enter the same element  
number until the desired entry appears.  
The menu options are presented similar to the following screen:  
RS-232 Options  
1. Main Menu  
2. Protocol: Async  
3. Baud Rate: 9600  
4. Parity: None  
5. Mode: 1-stop  
6. Code: 8-Bit ASCII  
7. Device: Wayne Dresler  
To return to the Main Menu at any time press “1” and  
hit “Enter”  
NOTE  
a. Menu Selection 2 – Protocol Options  
q
Asynchronous  
Kalatel CBR-PB3-WD  
29  
0150-0261A  
 
b. Menu Selection 3 – Baud Rate  
Baud Rate is only used if Protocol option selected is  
Asynchronous.  
q
q
q
q
q
q
q
1200  
2400  
4800  
9600  
14.4K  
19.2K  
38.4K  
c. Menu Selection 4 – Parity  
q
q
q
None  
Odd  
Even  
d. Menu Selection 5 – Mode  
The available selections are:  
q
q
1-Stop (bit)  
2-Stop (bit)  
e. Menu Selection 6 – Code (Character)  
The available selections are:  
q
q
7-Bit ASCII  
8-Bit ASCII  
f. Menus Selection 7 – Device Type  
q
q
q
q
Generic Receipt Printer  
Epson Printer  
Citizen Printer  
…other printers may be included  
IMPORTANT: You must BACKUP (Save) the program  
information via the BACKUP option so that everytime  
the unit is powered up, the settings you configured  
NOTE  
will be used. Go back to the Main Menu and select element  
#3 BACKUP and select the option to Save the settings.  
Kalatel CBR-PB3-WD  
30  
0150-0261A  
 
11 PB3-POS with DVMRe  
-CD/CS Units  
If the unit to be connected to the PB3 is a DVMRe-CD (Duplex) or a DVMRe-CS  
(Simplex) unit, please note the following changes to the normal installation and  
configuration process below.  
Kalatel recommends using a DVMRe-CT (Triplex) unit to  
initially connect the PB3 unit to. The on-screen text  
display will make it easy to confirm successful capture of  
POS transactions. Once you have confirmed proper  
operation, disconnect the Triplex unit and hook-up the  
Duplex (or Simplex) unit as indicated below.  
NOTE  
Alternatively, you can confirm configuration using a  
Laptop/PC running Windows HyperTerminal.  
11.1 DVMRe-CS/CD Setup  
Follow the installation steps in Section 5.1 through step number 8:  
Connecting the PB3 to a DVMRe-CS/CD:  
The PB3 connects to either RS-232/1 or RS-232/2 port of the DVMRe-  
CD/CS depending on if a modem is installed on RS-232/1 port.  
a. NO MODEM  
i. ProBridge Port #1 (RJ45) connects to RS-232/1 Port of  
the DVMRe-CD/CS using the supplied RJ45 to DB9F  
cable.  
ii. The DVMRe communications port needs to be  
programmed as follows:  
Communications>RS-232>Port 1 > ATM Activate  
b. MODEM (Connected to RS-232/1 Port of DVMRe-CD/CS)  
i. ProBridge Port #1 (RJ45) connects to RS-232/2 Port of  
the DVMRe-CD/CS using a RJ45 to DB9M cable. The  
provided RJ45 to DB9F cable can be used provided a  
Kalatel CBR-PB3-WD  
31  
0150-0261A  
 
gender changer is added to match the DB9M connector  
needed for the port on the DVMRe-CD/CS.  
ii. Modem must be configured for Port 1. The menu setup is:  
Communications>RS-232>Port 1> POTS.  
iii. The unit will have to be opened and a specific jumper  
setting set to allow text insertion on RS-232/2 Port.  
Contact Kalatel Tech Support for instructions on  
configuring the PORT 2 for text insertion.  
Transaction text is captured with video regardless of recording  
mode (Time-Lapse, Time-Lapse+Event or Event only). If Time-  
Lapse+Event or Event only recording modes must have at least  
one second set for the pre-event duration.  
NOTE  
Final Testing  
After hooking up the Duplex or Simplex unit, have some POS transactions  
generated. Allow sufficient time (2-3 minutes) before stopping recording and  
performing a text search from the DVMRe-CD/CS unit. Search for events based  
upon text and place a “*” in the text field and then select “Start Search”. All  
captured Cash Register transactions will be displayed in the list.  
Kalatel CBR-PB3-WD  
32  
0150-0261A  
 
12 Cable Specifications  
ProBridge to Triplex (DVMRe-CT)  
Part Number : 4310-0034B  
Pin 8:  
Pin 8:  
Communication Type: RS232  
Connector Type: RJ-45, RJ-45  
Pin 7: Common  
Pin 6: A-  
Pin 7: Common  
Pin 6: A-  
Pin 5: Rcv  
Pin 4: Tx  
Pin 5: Rcv  
Pin 4: Tx  
Cable Required: 5 Foot RJ-45 to RJ-45  
Triplex RS232 Cable (Supplied).  
Pin 3: A+  
Pin 2:  
Pin 3: A+  
Pin 2:  
Pin 1: Common  
Pin 1: Common  
Connects ProBridge to DVMRe-CT.  
RJ-45  
Connector  
RJ-45  
Connector  
to Triplex  
to PB3  
RJ-45 Connector  
RJ-45 Connector  
ProBridge to DVMRe (DVMRe-CD/S)  
Part Number : 4310-0047B  
Pin 9  
Communication Type: RS232  
Pin 8  
Pin 8  
Pin 7  
Pin 7  
Connector Type: RJ-45 ,DB9F  
Pin 6  
Pin 6  
Pin 5: Common  
Pin 5: Common  
Pin 4  
Cable Required: 6 Foot RJ-45 to DB9F  
Pin 4  
RS232 Cable (Supplied). Connects  
ProBridge to DVMRe-CD/CS.  
Pin 3: Rcv  
Pin 3: Rcv  
Pin 2: Tx  
Pin 1  
Pin 2: Tx  
Pin 1  
NOTE: This cable also used for  
Programming ProBridge via Windows  
RJ-45  
DB-9F  
Connector  
Connector  
to PB3  
to Duplex  
HyperTerminal  
RJ-45 Connector  
DB9F Connector  
Kalatel CBR-PB3-WD  
33  
0150-0261A  
 
ProBridge to ProBridge Cable  
Part Number : Installer Provided  
Pin 8:  
Pin 8:  
Communication Type: RS-485  
Connector Type: RJ45, RJ45  
Pin 7: Common  
Pin 6: A-  
Pin 7: Common  
Pin 6: A-  
Pin 5: Rcv  
Pin 4: Tx  
Pin 5: Rcv  
Pin 4: Tx  
Cable Required: RS-485 Interconnect  
Cable (up to 3,000’)). Interconnects  
multiple PB3’s in a RS485 network.  
Pin 3: A+  
Pin 3: A+  
Pin 2:  
Pin 2:  
Pin 1: Common  
Pin 1: Common  
RJ-45  
Connector  
RJ-45  
Connector  
RJ45 Connector  
RJ45 Connector  
ProBridge to ECR and Receipt Printer  
Pin 9  
Pin 9  
Pin 8  
Pin 7  
Pin 6  
Pin 5  
Pin 4  
Pin 3  
Pin 2  
Pin 1  
Part Number : 4310-0078A  
Pin 8  
Pin 7  
Communication Type: RS232  
Pin 6  
Pin 5  
Pin 4  
Connector Type: DB9F to DB9M to  
DB9F.  
Pin 3  
Pin 2  
Pin 1  
Cable Required: 6 Foot RS232 Cable  
(Supplied). Connects PB3 to the ECR  
DB9F  
DB9M  
and the Receipt Printer.  
Pin 9  
Pin 8  
Pin 7  
Pin 6  
Pin 5  
Pin 4  
Pin 3  
Pin 2  
Pin 1  
DB9F  
Connector  
DB9F Connector  
DB9F and DB9M Connector  
Kalatel CBR-PB3-WD  
34  
0150-0261A  
 
13 Specifications  
Physical  
Housing  
Metal enclosure.  
Dimensions  
(W x L x H)  
4.0” x 7.0” x 1.0”. (100mm x  
175mm x 25 mm)  
Nominal Weight  
Shipping Weight  
4.8 oz (136 g)  
1 lb (453 g) packaged, including  
the external AC power supply and  
manual.  
Color  
Black.  
Environmental  
Temperature  
0 to 40 °C, operating.  
Relative Humidity  
90%, non-condensing.  
Electrical  
AC Power  
Voltage Range:  
Current:  
External AC power supply included.  
110 to 240 VAC + 10%  
200 mA  
DC Power  
DC jack, positive center.  
Power Supply Voltage: 12 VDC  
Current:  
Power:  
110 mA  
1.5 W  
All specifications are subject to change without notice. Kalatel  
believes that all specifications are correct, however no liability is  
assumed for omissions or errors.  
NOTE  
Kalatel CBR-PB3-WD  
35  
0150-0261A  
 
14 Warranty and Service  
14.1 Factory Service  
If the unit requires factory service, contact the dealer who supplied the unit to you for the  
correct procedures on returning the unit to the factory or the nearest factory service center.  
If the dealer is not available, contact the manufacturer of the unit as detailed below and  
request a Return Material Authorization number (RMA). The unit’s serial number must be  
provided before an RMA number can be issued. Units returned to the factory for service  
must have freight and insurance prepaid, and must show the RMA number clearly on all  
shipping documents. The failure symptoms must be clearly described by the operator and  
enclosed with the unit together with a copy of the original supplier’s invoice. Failure to  
comply with these instructions will delay service of the unit, and may result in the unit not  
being accepted by the Repair Center.  
Factory Address  
Kalatel  
Attention: Repair Center  
3197-C Airport Loop Drive  
Costa Mesa, CA 92626  
United States of America  
Telephone: 800-343-3358 (7:00 AM to 4:30 PM, Pacific Time)  
In Oregon: 541-754-9133  
Fax: 541-754-7162 (24 hours a day)  
For warranty information, see the following page.  
14.2 Warranty  
Kalatel warrants all of its equipment for three years from the date of purchase. This  
warranty covers any defects in materials and workmanship. Equipment failures that are due  
to improper installation, modification, abuse, or acts of nature will not be covered by this  
warranty. The repair department will evaluate all equipment returned for repair to determine  
warranty coverage. The Tech Support Manager will resolve any questions that may arise  
during evaluation to make a final determination.  
Note: The three-year warranty does not apply to the following products:  
MobileView® and the monitor CRT, which carry a 12-month warranty from the date of  
purchase.  
The warranty specifically covers any defects in material and workmanship and does not  
cover equipment that has been abused, damaged, or modified.  
For all warranty repairs, Kalatel will cover all costs, including parts, labor, and shipping.  
Repaired equipment will be returned via the same method of shipment in which it was  
received. If a customer requests a faster return shipment, the difference will be charged.  
Kalatel CBR-PB3-WD  
36  
0150-0261A  
 
For all non-warranty repairs, the customer will be billed for parts, labor, and shipping.  
Labor will be billed in half-hour increments.  
Note: Customers requesting an estimate prior to repair will be notified by phone. If they  
cannot be reached, they will be notified by fax. If we are unable to reach the contact person  
for repair authorization after one phone attempt and two fax attempts, the equipment will be  
returned without being repaired. We will hold equipment no longer than two weeks.  
Advance Replacement Policy  
When an advance replacement is required, we will send the customer replacement  
equipment from our stock and receive the returned product in exchange. The received  
equipment will be evaluated and the repair department will determine whether it is a  
warranty replacement. If it is non-warranty, see our repair policy above for details. The  
following guidelines will be used for all advance replacements:  
·
·
·
Fewer than 45 days from purchase, Kalatel will replace the product with new  
equipment.  
From 45 days to 1 year from purchase, Kalatel will replace the product with  
refurbished equipment.  
From 1 year to 3 years from purchase, the product must be sent in for repair.  
Advance replacements will be sent for a fee of $100.  
If you have questions about this policy, please contact Kalatel’s RMA Department at  
800-469-1676.  
Kalatel CBR-PB3-WD  
37  
0150-0261A  
 

Eton Stereo System ES50 User Manual
Everpure Water System CG53 10 User Manual
Excalibur electronic Motorized Toy Car PR11BK 2 User Manual
Extron electronic Stereo Amplifier HPA 2001 100V User Manual
Field Controls Ventilation Hood PVO 300 User Manual
First Alert Smoke Alarm SA710 User Manual
Fujitsu Photo Scanner P3PC E807 01ENC2 User Manual
GE Air Conditioner ASV18DK User Manual
GE Freezer ZIFP360NX User Manual
GE Universal Remote 20621 User Manual