®
System Configuration and Order-information Guide
TX200 S3
March 2008
PRIMERGY TX200 S3
Instruction
This document contains basic product and configuration information that will enable you
to configure your system.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete
PRIMERGY Rack system.
You can configure your individual PRIMERGY servers in order to meet your specific requirements.
Please follow the lines. If there is a junction, you can choose which way or component
you would like to take.
Go through the configurator by following the lines from the top to the bottom.
The color of the junction means as follows.
Key to
Or
And
PRIMERGY TX200 S3
Data Sheet
Type
Dual-Processor Tower Server
PGUT2033A
Base Unit
CPU
Xeon® 5110 (1.60GHz)
Frequencies
Quad-Core Intel® Xeon® X5355 (2.66GHz) *6 / E5310 (1.60GHz) *7 /
Dual-Core Intel® Xeon® 5160 (3GHz) *8 / 5130 (2GHz) *9 / 5110 (1.60GHz)
Second-Level-Cache
Multi-Processor
2x4MB ( Quad-Core Intel® Xeon® X5355 (2.66GHz) / E5310 (1.60GHz) ) /
4MB ( Dual-Core Intel® Xeon® 5160 (3GHz) / 5130(2GHz) / 5110 (1.60GHz) )
1 (max. 2)
Front-Side-Bus
1333MHz ( Quad-Core Intel® Xeon® X5355 (2.66GHz) / Dual-Core Intel® Xeon® 5160 (3GHz) / 5130 (2GHz) ) /
1066MHz ( Quad-Core Intel® Xeon® E5310 (1.60GHz) / Dual-Core Intel® Xeon® 5110 (1.60GHz) )
Chipset
Memory
Intel® 5000V
1GB (512MB ECC DDR2 SDRAM Fully Buffered DIMM x 2, PC2 5300F) (SDDC(Single Device Data Correction) supported)
Standard
16GB (ECC DDR2 SDRAM Fully Buffered DIMM, PC2 5300F)
Maximum *1
Graphics Controller
Resolution *2 640x480 dot
800x600 dot
incl. Remote Management Controller, VRAM : 1.7MB
16777216 colors
16777216 colors
1024x768 dot
65536 colors
1280x1024 dot
256 colors
Internal Bays
3.5 inch
HDD
Number of bays
Available HDD *3
6 ( 8 by applying Internal HDD Unit Bay Conversion kit (PG-BC103) ) (hot plug)
73.4GB (PG-HDB75A) 15krpm, SAS
146.8GB (PG-HDB45A) 15krpm, SAS
(SAS)
300.0GB (PG-HDB35A) 15krpm, SAS
Maximum *3
1.8TB ( 2.4TB by applying Internal HDD Unit Bay Conversion kit (PG-BC103) ) *10
3 (2 free bays) ( 1 (0 free bay) by applying Internal HDD Unit Bay Conversion kit (PG-BC103) )
standard (Max. 24 ATAPI)
Internal Bays 5inch
CD-ROM
PCI Slots
PCI Express (x8) [x8]
1
PCI Express (x4) [x8]
1
PCI-X (64bit/100MHz) [3.3V] *4
PCI (32bit/33MHz) [5.0V]
PCI-X (64bit/100MHz) [3.3V]
2 (1 x Full Size)
1 (1 x Full Size)
1 ( SAS Controller occupies one slot. )
RAID Controller
SAS Controller
Internal FDD
standard (SAS Controller)
SAS x 8ports (Installed as standard) (with RAID1 function)
3.5inch (1.44MB/720KB)
Network Controller (onboard)
Interfaces
1 port (1000BASE-T/100BASE-TX/10BASE-T)
Display (Analog RGB), Serial Port x 2 (D-SUB 9pins), Parallel Port (optional, D-SUB 25pins)
Keyboard (PS/2type Mini DIN 6pins), Mouse (PS/2type Mini DIN 6pins)
USB x 5 (ver. 2.0) (Internal : x 2,External : x 3)
ServerView (Standard)
Server Management Software
Remote Service function
connector
standard (onboard, Remote Management Controller)
1 port (100BASE-TX/10BASE-T)
Power supply Voltage
AC 100-127V (50/60Hz) / AC 200-240V (50/60Hz) x 1
( AC 100-127V (50/60Hz) / AC 200-240V (50/60Hz) x 2 when Power Supply Conversion kit (PGBRSU104) is applied. )
575W / 2070kJ/h (max.)
Power consumption
Redundant power supply
optional (hot plug when Power Supply Conversion kit (PGBRSU104) is applied.)
optional (hot plug when Power Supply Conversion kit (PGBRSU104) is applied.)
Tower : 174 (286 incl. protruding parts)(W) x 755 (D) x 474 (H)
Rackmount ( when Rack Conversion kit for TX200 S3 (PG-R1CK20/PGBR1CK20) is applied.)
: 483 (W) x 700 (750 incl. protruding parts) (D) x 177 (4U) (H)
Tower : 38kg (max.) / Rackmount: 40kg (max.)
Redundant Fan
Dimensions (mm)
Weight
Environmental Conditions
OS Support *5
Temperature10-35°C / Humidity 20-80% (non condensing )
Windows Server® 2003 R2, Standard Edition / Windows Server® 2003 R2, Standard Edition (SP2 *11)
Windows Server® 2003 R2, Enterprise Edition / Windows Server® 2003 R2, Enterprise Edition (SP2 *11)
Windows Server® 2003, Standard Edition (SP1/SP2 *11) / Windows Server® 2003, Enterprise Edition (SP1/SP2 *11)
Windows Server® 2003 R2, Standard x64 Edition / Windows Server® 2003 R2, Standard x64 Edition (SP2 *11)
Windows Server® 2003 R2, Enterprise x64 Edition / Windows Server® 2003 R2, Enterprise x64 Edition (SP2 *11)
Windows Server® 2003, Standard x64 Edition / Windows Server® 2003, Standard x64 Edition (SP2 *11)
Windows Server® 2003, Enterprise x64 Edition / Windows Server® 2003, Enterprise x64 Edition (SP2 *11)
Windows® 2000 Server (SP4) / Windows® 2000 Advanced Server (SP4)
Red Hat Enterprise Linux AS (v.3 for x86) *12 *13 / Red Hat Enterprise Linux ES (v.3 for x86) *12 *13
Red Hat Enterprise Linux AS (v.4 for x86) *12 / Red Hat Enterprise Linux ES (v.4 for x86) *12
Red Hat Enterprise Linux AS (v.4 for EM64T) *12 / Red Hat Enterprise Linux ES (v.4 for EM64T) *12
Red Hat Enterprise Linux 5 (for x86) *12 *14 / Red Hat Enterprise Linux 5 (for Intel64) *12 *14
ServerStart (Setup Support tool) *15
Attached tool (Standard)
*1. Available memory capacity will be changed by the type of OS. Please find more details in Notes[Memory OS Compatibility List].
*2. Resolution is determined by functions of the display monitor and OS.
*3. HDD capacity is calculated according to the formulas 1GB=1000 3 byte and 1TB=10004 byte.
*4. Frequency will be changed by the spec of PCI card and number of cards mounted.
*5. Drivers for Linux are not attached. Please download and use drivers of the following URL.
*6. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon X5355(2.66GHz/2x4MB) (PGBFU405) is available for upgrading to Quad-Core Intel® Xeon® X5355 2.66GHz.
*7. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon E5310(1.60GHz/2x4MB) (PGBFU403) is available for upgrading to Quad-Core Intel® Xeon® E5310 1.60GHz.
*8. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon 5160(3GHz/4MB) (PGBFU30T2) is available for upgrading to Dual-Core Intel® Xeon® 5160 3GHz.
*9. CPU Conversion kit: Xeon 5110(1.60GHz/4MB) -> Xeon 5130(2GHz/4MB) (PGBFU30S2) is available for upgrading to Dual-Core Intel® Xeon® 5130 2GHz.
*10. In case that SAS Controller installed as standard is used for RAID configuration, only 2 HDDs of same capacity and same rpm can be connected.
*11. There are some notes for Windows 2003 SP2. Please refer to Notes of Support Matrix.
*12. Regarding supported kernel versions of Linux, please refer to the following list.
*13. Quad-Core Intel® Xeon® X5355 (2.66GHz) / E5310 (1.60GHz) are not included.
*14. Total number of cores of CPU(s) should be four or more for using VM (Virtual Machine) function.
*15. ServerStart doesn't support Linux.
*. Noise level is 37dB. ( Noise level is 47dB when Power Supply Conversion kit (PGBRSU104) is applied. )
PRIMERGY TX200 S3
Configuration Diagram
Power Supply Unit
Power Supply Unit
CPU
Xeon®
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
When Internal HDD Unit Bay Conversion kit (PG-
BC103) is applied. ( HDD x 2ports )
Internal Backup Device cannot be mounted
because 5inch Bay x 2 is used by HDDs.
*2
5 inch Bay 3
5 inch Bay 2
*1
5 inch Bay 1
CD-ROM Drive / FDD
5130 (2GHz)/
5110 (1.60GHz)
Bay 8
SAS
Memory
Xeon®
DIMM Slot 3B
DIMM Slot 2B
DIMM Slot 1B
DIMM Slot 3A
DIMM Slot 2A
DIMM Slot 1A
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
Bay 7
SAS
3.5 inch HDD Bay 6
(hot plug)
Hard Disk 3.5inch Bay (hot plug)
Standard Drive Cage ( HDD x 6ports )
3.5 inch HDD Bay 5
(hot plug)
PCI Slots
3.5 inch HDD Bay 4
(hot plug)
Bay 6
SAS
PCI5 PCI 32bit/33MHz
PCI4 PCI Express (x4)
PCI3 PCI Express (x8)
3.5 inch HDD Bay 3
(hot plug)
Bay 5
SAS
3.5 inch HDD Bay 2
(hot plug)
PCI2 PCI-X 64bit/100MHz *3
PCI1 PCI-X 64bit/100MHz *3
PCI10 PCI-X 64bit/100MHz
3.5 inch HDD Bay 1
(hot plug)
Bay 4
SAS
Bay 3
SAS
*1. By applying Internal HDD Unit Bay Conversion kit (PG-BC103), 5 inch bay x 2 can be converted
to 3.5 inch bay x 2.
When Internal HDD Unit Bay Conversion kit (PG-BC103) is applied, Internal Backup Device
cannot be mounted on 5inch Bay.
Bay 2
SAS
*2. By applying Power Supply Conversion kit (PGBRSU104), non-redundant structure (Power Supply x1,
FAN x2) can be converted to redundant structure (Power Supply x2, FAN x6).
*3. Frequency will be changed by the spec of PCI card and number of cards mounted.
Bay 1
SAS
*Components installed as standard configuration marked in grey.
Mountable I/O Options
PCI Slot
10
1
2
3
4
5
PCI-X
PCI Express
PCI
Mount
Priority
Max No.
of Mount
Mountable Cards
Bus
Remarks
64bit/
100MHz
64bit/
100MHz *1
x8
x4
32bit/
33MHz
lane
lane
Full Height
x8 socket
3.3V
5.0V
-
SAS Controller
(8ports)
-
PCI-X/64bit
PCI-X/64bit
PCI-X/64bit
PCI-X/64bit
PCI/32bit
#
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
1
Standard, Internal array
Internal array
High
PG-140F /
PGB140F
SAS RAID Ctrl
[1]
[1]
[1]
[1]
[1]
[1]
[2]
[2]
-
-
-
1
1
2
2
2
2
PG-140G /
PGB140G
SAS RAID Ctrl
-
-
-
Internal array
PG-1892 /
PGB1892
Eth. Ctrl 1000-BASE-T Cu
[2]
[2]
[2]
[2]
[1]
[1]
-
-
-
[3]
[3]
[3]
[3]
[3]
[3]
-
Eth. Ctrl 1x1Gbit PCI
1000-BASE-T
PG-1853 /
PGB1853
* No AFT/ALB Support
-
-
2
3
Eth. Ctrl 1000-BASE-SX
Fibre LC
PG-1882
PG-1863
PCI-X/64bit
PCI-X/64bit
PCI/64bit
-
-
Eth. Ctrl 2x1Gbit PCI-X
1000-BASE-T
-
-
RAID Ctrl 2-Channel 128MB PG-142E3 /
w/ BBU
-
-
2
2
2
2
2
2
External array
PGB142E3
Low
PG-1281 /
PGB1281
Internal/External SCSI
Controller
SCSI Ctrl U160
PCI/64bit
-
-
PG-FC202 /
PGBFC202
PCI Express
(x4)
Fibre Channel Controller
[1]
[1]
[1]
[1]
[2]
[2]
[2]
[2]
PCI Express Card
PCI Express Card
PCI Express Card
PCI Express Card
High
Eth. Ctrl 2x1Gbit PCI-E
1000-BASE-T
PG-2861 /
PGB2861
PCI Express
(x4)
-
-
-
Eth. Ctrl 1x1Gbit PCI-E
1000-BASE-T
PG-289 /
PGB289
PCI Express
(x1)
-
-
-
Low Eth. Ctrl 1x1Gbit PCI-E
1000BASE-SX
PCI Express
(x4)
PG-288
-
-
-
* [n] : Installation Priority
* # : standard
* - : cannot be installed
*1.Frequency will be changed by the spec of PCI card and number of cards mounted.
PRIMERGY TX200 S3
Connection Table
Form factor conversion
(Tower to Rackmount)
Rack Conversion kit for TX200 S3
(Tower to Rackmount (4U))
PG-R1CK20
PGBR1CK20 (for CTO)
CPU
Max: 2 CPU
Processor Xeon X5355 2.66GHz/2x4MB
PG-FG405
CPU
Slot
PGBFG405 (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon X5355(2.66GHz/2x4MB) (PGBFU405) is applied.
Processor Xeon E5310 1.60GHz/2x4MB
PG-FG403
PGBFG403 (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon E5310(1.60GHz/2x4MB) (PGBFU403) is applied.
Processor Xeon 5160 3GHz/4MB
PG-FG30T
PGBFG30T (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon 5160(3GHz/4MB) (PGBFU30T2) is applied.
Processor Xeon 5130 2GHz/4MB
PG-FG30S
PGBFG30S (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB) -> Xeon 5130(2GHz/4MB) (PGBFU30S2) is applied.
Processor Xeon 5110 1.60GHz/4MB
PG-FG30R
PGBFG30R (for CTO)
*. This option is available when the processor of the base unit
is Processor Xeon 5110(1.60GHz/4MB).
*CPU Conversion Kit (available only as a Configure To Order (CTO) option; no separate shipment is possible)
Type
Product ID
PGBFU405
CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB)
-> Xeon X5355(2.66GHz/2x4MB)
(for CTO)
Dual-Core Intel® Xeon® 5110(1.60GHz/4MB) -> Quad-Core Intel® Xeon® X5355(2.66GHz/2x4MB)
Convert the CPU installed as standard in the base unit to the other.
(Note: This option can be ordered only as coupled with the base unit.
A separate shipment is not possible.)
CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB)
-> Xeon E5310(1.60GHz/2x4MB)
(for CTO)
Dual-Core Intel® Xeon® 5110(1.60GHz/4MB) -> Quad-Core Intel® Xeon® E5310(1.60GHz/2x4MB)
Convert the CPU installed as standard in the base unit to the other.
(Note: This option can be ordered only as coupled with the base unit.
A separate shipment is not possible.)
PGBFU403
PGBFU30T2
PGBFU30S2
CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB)
-> Xeon 5160(3GHz/4MB)
(for CTO)
Dual-Core Intel® Xeon® 5110(1.60GHz/4MB) -> Dual-Core Intel® Xeon 5160(3GHz/4MB)
Convert the CPU installed as standard in the base unit to the other.
(Note: This option can be ordered only as coupled with the base unit.
A separate shipment is not possible.)
CPU Conversion Kit:
Xeon 5110(1.60GHz/4MB)
-> Xeon 5130(2GHz/4MB)
(for CTO)
Dual-Core Intel® Xeon® 5110(1.60GHz/4MB) -> Dual-Core Intel® Xeon® Xeon 5130(2GHz/4MB)
Convert the CPU installed as standard in the base unit to the other.
(Note: This option can be ordered only as coupled with the base unit.
A separate shipment is not possible.)
PRIMERGY TX200 S3
Memory (PC2 5300F)
Max: 16GB
Memory
Slot
Memory Module-1GB (512MB FB-DIMM x 2)
PG-RM1CE
Standard Memory Module: 1GB (512MB FB-DIMM x 2)
Memory Module-2GB (1GB FB-DIMM x 2)
PG-RM2CE
Memory Module-4GB (2GB FB-DIMM x 2)
PG-RM4CE
Memory Module-8GB (4GB FB-DIMM x 2)
PG-RM8CE
Memory Module Conversion kit (for CTO)
Memory
Slot
Memory Module Conversion kit-2GB (1GB FB-DIMM x 2)
PGBRU2CE (for CTO)
1GB -> 2GB
1GB -> 4GB
Memory Module Conversion kit-4GB (2GB FB-DIMM x 2)
PGBRU4CE (for CTO)
* Notes on installing memory
1. Memory is installed by pairs of FB-DIMMs of the same capacity. Installation of one FB-DIMM or a mixed -capacity pair is impossible.
2. The memory capacities of the slots should be in ascending order in the following sequence:
DIMM slots 1A,1B (Bank 1) -> DIMM slots 2A,2B (Bank 2) -> DIMM slots 3A,3B (Bank 3)
(Available Memory Area)
Mounted Memory
Available Memory Area
~3.0GB
4.0GB
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"
Same as the size of mounted memory
Windows® 2000 Server (SP4)
~7.0GB
8.0GB
Windows® 2000 Advanced
Server (SP4)
Others
~16.0GB
*. Spare Memory function
In the case of using Spare Memory function, same DIMMs of two or more banks are required to be installed.
Available memory capacity is "installed memory" minus "capacity of Spare Memory ( 1 Bank )".
PRIMERGY TX200 S3
Connecting Internal HDD and Internal Backup Devices
If you would like to order internal HDDs and internal backup devices, please order optional cards/cables according to the following table.
Type of HDD connection
Internal Backup Devices PRIMERGY TX200 S3
Connection
Drive Cage
Standard Drive Cage
(6bays)
Interface
USB (''1) Connection
SCSI Wide (''2) Connection
SAS Controller (standard)
*. In case that SAS Controller installed as standard
is used for RAID configuration, only 2 HDDs of same
capacity and same rpm can be connected.
Onboard USB
(internal port)
SCSI Card (PG-1281/PGB1281)
SCSI Cable (PG-CBLS025) (''3)
SAS /
RAID
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
SAS Controller (standard)
*. Only SAS Configuration is supported.
-
-
(not connect)
(not connect)
Standard Drive Cage
(6bays)
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
Onboard USB
(internal port)
SCSI Card (PG-1281/PGB1281)
SCSI Cable (PG-CBLS025) (''3)
RAID
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
-
-
(not connect)
(not connect)
(''1) USB Backup Devices: PG-DT504
(''2) SCSI Wide Backup Devices: PG-LT302/PG-LT201/PGBLT201C1/PG-LT102
(''3) If you order internal backup devices by CTO, SCSI cable is attached with backup devices.
Internal HDD
SAS / RAID Configuration
HDD SAS 15k 73GB hot plug 3.5inch
PG-HDB75A
PCI Bus
SAS Controller
( installed as standard )
PGBHDB75A (for CTO)
*. In case that SAS Controller installed
as standard is used for RAID configuration,
only 2 HDDs of same capacity and same
rpm can be connected.
HDD SAS 15k 147GB hot plug 3.5inch
PG-HDB45A
Internal HDD Unit Bay
Conversion kit
PGBHDB45A (for CTO)
*. RAID1 configuration can be set.
*. Hot spare disk cannot be set.
PG-BC103
HDD SAS 15k 300GB hot plug 3.5inch
PG-HDB35A
RAID Configuration
PGBHDB35A (for CTO)
PCI Bus
*. When Internal HDD Unit Bay Conversion kit
(PG-BC103) is applied, up to 8 Internal HDDs
can be mounted but internal backup devices
cannot be mounted on 5inch Bays.
SAS RAID Ctrl
(without BBU)
PG-140F
PGB140F (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
To set RAID configuration, two or more HDDs
which are same capacity and same rpm
should be connected to SAS Controller
installed as standard.
SAS RAID Ctrl
(with BBU)
PG-140G
PGB140G (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
To set RAID configuration, two or more HDDs
which are same capacity and same rpm
should be connected to SAS Controller
installed as standard.
PRIMERGY TX200 S3
Internal backup device
Tape Drv LTO3 Ultrium3/Ultrium2 400GB
PG-LT302
( In case that internal backup device is ordered by CTO. )
*. One SCSI cable is attached with backup device ordered
PCI Bus
Tape Drv LTO3 Ultrium3/Ultrium2 400GB
SCSI Ctrl U160
PG-1281
by CTO and can be connected to multiple backup devices.
*. One internal backup device can be ordered by CTO.
w/ SCSI Cable
PGBLT302C (for CTO)
*. One internal backup device can
be ordered by CTO.
PGB1281 (for CTO)
( In case that internal backup device is ordered without CTO. )
Tape Drv LTO2 Ultrium2 200GB
PG-LT201
Tape Drv LTO2 Ultrium2 200GB
w/ SCSI Cable
SCSI Cable 1.7m
PGBLT201C1 (for CTO)
*. One internal backup device can
be ordered by CTO.
PG-CBLS025
*. One SCSI cable can be connected to multiple backup devices.
Tape Drv LTO Ultrium1 100GB
PG-LT102
*. In case that internal backup device is ordered by CTO,
SCSI Ctrl U160 (PGB1281) should be ordered too.
*. One internal backup device can be ordered by CTO.
*. When internal HDD Unit Bay Coversion kit (PG-BC103) is applied,
internal backup devices can not be mounted on 5 inch bays.
Tape Drv LTO Ultrium1 100GB
w/ SCSI Cable
2 slots / Max: 2
PGBLT102C (for CTO)
*. One internal backup device can
be ordered by CTO.
Internal backup device (USB)
Tape Drv DAT72 36GB internal
PG-DT504
USB Interface
(internal)
PGBDT504 (for CTO)
*. One internal backup device can
be mounted.
*. One internal backup device(USB) can be ordered by CTO.
*. When internal HDD Unit Bay Coversion kit (PG-BC103) is applied,
internal backup devices can not be mounted on 5 inch bays.
Internal DVD-RAM
Onboard IDE
Controller
DVD-RAM Conversion kit (CD-ROM Drive -> DVD-RAM Drive)
PGBDVAU104 (for CTO)
Internal backup device (PRIMERGY SX10)
*PRIMERGY SX10 is available for rack install type.
PCI Bus
SCSI Ctrl U160
PG-1281
SCSI Cable HDCI 1.5m
PG-CBLS001
PRIMERGY SX10
PG-R1BC4
PGB1281 (for CTO)
SCSI Cable HDCI 5m
PG-CBLS002
*Please find more information on the internal backup devices for PRIMERGY SX10
in Rackmount[Internal Backup Devices with PRIMERGY SX10 ]
Power Supply Units/ Fan (CTO only)
Power Supply Slot/ Fan
Power Supply Conversion kit
PGBRSU104 (for CTO)
( non-redundant structure (Power Supply x1, FAN x2)
-> redundant structure (Power Supply x2, FAN x6) )
PRIMERGY TX200 S3
LAN Card (Standard PCI Slot)
On-board LAN
Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T
PG-2861
PCI Express Bus
Twist Pair Cable ( Category 5e)
PGB2861 (for CTO)
* Dual Port
Eth. Ctrl 1x1Gbit PCI-E 1000-BASE-T
PG-289
PGB289 (for CTO)
Eth. Ctrl 1x1Gbit PCI-E 1000BASE-SX
PG-288
Multi Mode Fibre Channel Cable
Twist Pair Cable ( Category 5e)
Eth. Ctrl 2x1Gbit PCI-X 1000-BASE-T
PCI Bus
PG-1863
* Dual Port
Eth. Ctrl 1000-BASE-T Cu
PG-1892
PGB1892 (for CTO)
Eth. Ctrl 1x1Gbit PCI 1000-BASE-T
PG-1853
PGB1853 (for CTO)
* No AFT/ALB Support
Eth. Ctrl 1000-BASE-SX Fibre LC
PG-1882
Multi Mode Fibre Channel Cable
Server Management (Remote Management Controller)
LAN interface for Remote
Management Controller
Twist Pair Cable ( Category 5e)
Remote Management Ctrl Upgrade kit
PG-RMCU1
Parallel Port Option
Back-side Panel
Parallel Port Option
PG-PP04
Specifications are subject to change without notice. For the latest detailed information, contact your local representative.
All brand names and product names are trademarks and registered trademarks of their respective holders.
©2006 Fujitsu Limited. All rights reserved. Printed in Japan.
Global Business Development & Marketing
Business Strategy & Planning
System Products
|