RGB 460xi /472xi FSR Series and
AAP 102 FSR Installation Guide
FSR Floor box-Mounted Interface
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500
Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040
Fax +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400
Fax +65.6383.4664
Extron Electronics, Japan
Daisan DMJ Building 6F
3-9-1 Kudan Minami
Chiyoda-ku, Tokyo 102-0074 Japan
+81.3.3511.7655
68-636-05 Rev. A
Printed in the USA
06 03
Fax +81.3.3511.7656
© 2003 Extron Electronics. All rights reserved.
Table of Contents
About this Guide....................................................................... 1
Installation Overview............................................................. 1
Installation Instructions ....................................................... 2
Preparing the site and cables................................................... 2
Mounting the interface or adapter plate to the floorbox .... 3
Specifications ............................................................................. 4
Included Parts............................................................................. 5
Accessories................................................................................... 5
Cables ............................................................................................. 6
Male-to-male VGA cables ........................................................... 6
Male-to-male 90° VGA cables .................................................. 6
Adapter kits .............................................................................. 6
High resolution cables .............................................................. 6
All trademarks mentioned in this manual are the properties of their respective owners.
68-636-05 Rev. A
Printed in the USA
06 03
RGB 460xi/472xi/AAP 102 FSR Series • Table of Contents
i
Table of Contents, cont’d
About this Guide
This guide contains instructions for mounting two different
®
Extron computer interfaces and an adapter plate into FSR floor
boxes. The interfaces are standard RGB 460xi series and RGB
472xi series interfaces tailored to fit the FSR floor box.
The AAP 102 FSR adapter plate is a blank faceplate for the FSR
floor box, to which any standard Extron AAP (Architectural
Adapter Plate) can be mounted.
In this guide, the terms “FSR interface” and “Interface” are used
interchangeably.
For information about operating and wiring the interface, refer
to the RGB 400xi Series User Manual, Part #68-542-01, or the RGB
470xi Series User’s Manual, Part #68-661-01, depending on the
specific product you are using.
Installation Overview
Installation and service must be performed by
authorized personnel only. These products must be
used with UL approved electrical boxes.
CAUTION
Install the interface or adapter plate as follows:
Turn all of the equipment off. Make sure that the
computer, the interface, and the output devices (projector/
monitor, speakers) are all turned off and disconnected
from the power source.
1
Select the installation location and install the electrical
floor box. Refer to the documentation that was included
with the floor box.
2
3
4
Route the cables that connect to the rear of the interface (or
the AAP(s) to be installed in the AAP 102 FSR adapter
plate).
Set the gain and DIP switches (or the switch(es) on the rear of
the AAP(s) to be installed in the AAP 102 FSR adapter plate).
Refer to the RGB 400xi Series User Manual, Part #68-542-01, the
RGB 470xi Series User Manual, Part #68-661-01.
For the AAP 102 FSR adapter plate only, secure the
AAP(s) to the front of the faceplate.
5
6
Connect the video, audio, and power cables to the rear of the
device. Refer to the RGB 400xi Series User Manual, Part #68-
542-01, the RGB 470xi Series User Manual, Part #68-661-01.
Connect power cords and turn on the projector or monitor
and audio device, the interface, and the computer.
7
ii
RGB 460xi/472xi/AAP 102 FSR Series • Table of Contents
RGB 460xi/472xi/AAP 102 FSR Series • Installation Guide
1
Installation, cont’d
The picture should now appear, and sound should be
8
audible. If not, ensure that all devices are plugged in and
receiving power. Check the cabling and switch settings,
and make adjustments as needed.
Plastic Filler Strip
(optional)
T
IF
SH
.
H
R
P
O
IT
N
O
X
M
A
MIN/M
T
U
IN
Disconnect power from all the devices.
R
9
O
IT
N
O
M
IO
D
O
N
AU
R
O
IT
N
O
M
RGB 460xi FSR
Mount the interface or adapter plate into the floor box.
See Mounting the interface or adapter plate to the floor box in
this manual.
10
RGB 460xi FSR
Mounting Plate
Restore power to the devices.
11
Installation Instructions
Installation
Cable
The interface must be installed into an
CAUTION
Underwriters Laboratories (UL) approved FSR
electrical floor box. The floor box is not included
with the interface; the installer is responsible for
obtaining and installing the box.
Preparing the site and cables
Choose a location that allows cable runs without interference.
Allow enough depth for both the floor box and the cables. You
need to run the conduit (if required by local code) and cables
under the floor before installing the interface.
The installation must conform to national and local electrical
codes and to the interface’s size requirements.
1.
2.
3.
Install the floor box in accordance with the documentation
that accompanied the box.
FSR Box
Feed cables through the floor box punch-out holes, and
secure them with cable clamps to provide strain relief.
Screw
Exposed cable shields (braids or foil) are potential sources
of short circuits. Trim back and/or insulate shields with
heat shrink, or ground the shield to the box (figure 1).
Braided Shield
Figure 1 — Securing the RGB 460xi FSR adapter
plate to the floor box and grounding the braided
shield
To prevent short circuits, the outer foil shield can be
cut back to the point where the cable exits the cable
clamp. Both braided and foil shields should be
connected to an equipment ground at the other end
of the cable.
CAUTION
5.
Secure the interface or adapter plate to the floor box with
the screws provided. See Mounting the interface or adapter
plate below.
4.
Set the gain and DIP switches and cable and test the device
before securing it into the floor box. The switches and
cables will be inaccessible after installation.
Mounting the interface or adapter plate to the
floor box
Refer to the RGB 400xi Series User Manual, Part #68-542-01
or the RGB 470xi Series User Manual, Part #68-661-01 for
additional information.
1.
Disconnect the power supply to remove power from the
interface.
2.
If installed, remove the floor box’s top panel and trim frame.
2
RGB 460xi/472xi/AAP 102 FSR Series • Installation Guide
RGB 460xi/472xi/AAP 102 FSR Series • Installation Guide
3
Installation, cont’d
3.
Place the interface or adapter plate through the opening in
Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) /
10% to 90%, non condensing
the floor and into the floor box. Take care not to damage
the cables, which lay behind the interface in the bottom of
the box.
Operating +32° to +122°F (0° to +50°C) /
10% to 90%, non condensing
Rack mount................................... No, but FSR floor box mountable
Enclosure type.............................. Metal
Enclosure dimensions
4.
Mount the interface or adapter plate(s) to the floor box
with the included machine screws.
Install the faceplate with four
machine screws (included).
RGB 460xi/472xi FSR
Plate.......................... 4.5" H x 3.6" W (11.4 cm H x 9.1 cm W)
Back enclosure ........ 2.7" H x 3.3" W x 1.1" D
(6.9 cm H x 8.4 cm W x 2.8 cm D)
(Depth excludes front panel connectors
and controls.)
AAP 102 FSR .................... 4.5" H x 3.6" W (11.4 cm H x 9.1 cm W)
Specifications are subject to change without notice.
Included Parts
These items are included in each order for the indicated interface:
Included parts
Part number
60-373-40
60-515-40
60-301-40
70-055-01
68-542-01
68-661-01
100-216-01
RGB 460xi FSR, black
Install the plastic filler
strips (optional).
RGB 472xi FSR, black
AAP 102 FSR
Figure 2 — AAP 102 FSR, RGB 460xi FSR, and RGB
472xi FSR installed
12VDC, 1.0A external power supply kit
RGB 400xi Series User’s Manual
RGB 470xi Series User’s Manual
Plastic filler strip
5.
If necessary, install a plastic filler strip (included with the
interface or adapter plate) to fill the gap when the devices
are installed in either end position (right or left).
RGB 400xi FSR Series Installation Guide
6.
Install the floor box’s top panel and trim frame.
Reconnect the power supply.
7.
Accessories
Specifications
Accessories
Part number
10-306-01
26-340-01
26-340-02
26-287-01
26-173-01
26-397-01
This guide shows power requirements and physical
3.5 mm stereo plug
Mac/VGA adapter
Mac HV/VGA adapter
Mac 35/VGA 6’ adapter
SY VGA/XGA adapter
SY 15 HDM RGBHVF
specifications only. For electrical and functional specifications,
refer to the RGB 400xi Series User Manual, Part #68-542-01 or the
RGB 470xi Series User’s Manual, Part #68-661-01, depending on
the specific product you are using.
General
Power............................................. 12VDC, 0.42 A, 5 watts, external (the
power supply is included.)
4
RGB 460xi/472xi/AAP 102 FSR Series • Installation Guide
RGB 460xi/472xi/AAP 102 FSR Series • Installation Guide
5
Installation, cont’d
Cables
Male-to-male VGA cables
Part number
26-238-01
VGA M6’ MHR
VGA M3’ MHRA (with audio)
VGA M6’ MHRA (with audio)
VGA M12’ MHRA (with audio)
26-490-01
26-490-02
26-490-03
Male-to-male 90° VGA cables
Part number
VGAM 90 MHRA 6’ (with audio)
26-510-02
Adapter kits
Part number
Mac 15-pin HD F adapter cable kit w/audio
70-156-01
13W3 15-pin HD F adapter cable kit w/audio 70-157-01
High-resolution cables
BNC-5-3’HR
Part number
26-260-15
26-260-01
26-260-02
26-260-03
26-260-04
26-260-16
26-260-05
26-378-01
26-378-02
26-378-03
26-378-04
26-378-05
26-378-06
26-378-07
BNC-5-6’HR
BNC-5-12’HR
BNC-5-25’HR
BNC-5-50’HR
BNC-5-75’HR
BNC-5-100’HR
BNC-5-3’HRP (plenum)
BNC-5-6’HRP (plenum)
BNC-5-12’HRP (plenum)
BNC-5-25’HRP (plenum)
BNC-5-50’HRP (plenum)
BNC-5-75’HRP (plenum)
BNC-5-100’HRP (plenum)
Bulk installation cable
(14-conductor, non-plenum), 500’ HR
22-120-02
22-111-03
Bulk installation cable
(17-conductor, plenum), 500’ HR
6