GE Air Conditioner AZ22E09DP User Manual

GE Appliances  
AZ22E09D*P - GE Zoneline Dry Air 25 Series Cooling and Electric Heat Unit  
Electrical Wiring  
Wall Case Dimensions  
Maximum Cord Extension  
(in inches)  
All wiring, including installation of receptacle, must be made in accordance with local electrical  
codes and regulations.  
Note: Aluminum wiring may pose special problems—consult a qualified electrician.  
RAB71A = 20-7/8  
RAB77A = 21  
7-1/8  
Grille  
A
Resistance Heat  
Resistance heat or back-up heat determined by Quick Connect power cord on the Premium Series  
and selected heater size for the Value Series (15 amp. 8,600 BTU, 20 amp. 11,700 BTU and 30  
amp. 17,000 BTU @ 230 volt).  
RAB71A = 16  
RAB77A = 16-1/4  
SIDE  
VIEW  
C
Grille Options  
Inside  
Outside  
Stamped Aluminum GrilleRAG60  
Molded Exterior Architectural Louvers (Cycoloy)  
RAG61 or RAG64 (Beige)  
RAG62 or RAG65 (Maple)  
Ducted Applications  
2200 and 3200 series can be used with ductwork to heat or cool more than one room. RAK605 Duct  
Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied to right or left  
of adaptor. Locally fabricated ductwork may be added to extend to maximum recommended distance  
of 15 feet.  
RAG63 or RAG66 (Bittersweet)  
RAG67 (Extruded Aluminum)  
B
Room  
Cabinet  
RAB71 Insulated Wall Case  
Heavy-gauge galvanized steel, with insulation.  
A-42", B-13-3/4", C-16"  
RAB77 Wall Case  
Molded SMC fiberglass-reinforced polyester compound.  
A-42-1/8", B-13-7/8", C-16-1/4"  
Electrical Connection  
21  
58  
230/208 volt units may be plugged into a receptacle. 265 volt units and special application 230/208  
volt units require direct connection. See Architects and Engineers Design Data Manual for electrical  
connection information including use of sub-base for direct connected units. Installation must  
comply with local electrical codes and regulations.  
Wall Opening Dimensions  
Inside  
Add 1/4" to A and C dimensions for all cut-out size.  
Zoneline Installation  
Simple Three-Step Installation  
1. Frame the Opening. The RAB77A SMC wall case requires an opening of 16-1/2" high x 42-3/8"  
wide. Position the sleeve, secure it to the studs and then caulk. Complete instructions are furnished  
with each unit.  
2. Connect the Electrical Supply. Each Zoneline unit requires a 230/208V power supply. It is  
strongly recommended that electrical connections be made by a qualified electrician. All wiring,  
including installation of the receptacle, must be in accordance with local codes.  
Zoneline heat pumps and heat/cool units are designed for easy installation, off or flush with the floor.  
When the SMC fiberglass-reinforced polyester sleeve is installed, the chassis simply slides into place.  
Compatibility with existing Zoneline wall cases and rear grilles simplifies retrofit installations. A new  
chassis simply slides into the already installed wall case; the existing rear grille may be used as is, or  
with a minor modification for greater operating efficiency.  
3. Slide In Chassis. With the wall sleeve, electrical receptacle, and exterior grille in place, the  
separate chassis simply slides into position. Install the roomside cabinet, and plug into the electrical  
receptacle. You are now ready for many years of quiet comfort.  
®
For answers to your Monogram, GE Profile Performance Series, GE Profile, and  
GE appliance questions, call GE Answer Center® service, 800.626.2000.  
Created 3/99  
 

Cradlepoint Modem MC100W User Manual
Cub Cadet Automobile M466 User Manual
Cuisinart Coffeemaker DCC 1200C User Manual
Dimplex Vacuum Cleaner SV8000 User Manual
Edimax Technology Network Router BR 6204WG User Manual
ELANsat Tech Camera Accessories CF232 User Manual
Fisher Price Video Games P8897 User Manual
Frontier Labs Spreader MS1102G User Manual
GE Dishwasher GLC4000 User Manual
GE Ventilation Hood SCA2000BBB User Manual