Everpure Water System CES 2750M 101 User Manual

CES 2750 Series  
Water Conditioner  
Water Conditioning for Commercial and Light Industrial Applications  
Available in Single Tank System with 1” Porting  
B E N E F I T S  
Hardness removal of 34,000 to 101,000 grains at  
flow rates up to 20 gallons per minute continuous  
Meter initiated regeneration minimizes salt,  
water, and electrical costs  
Advanced user-friendly controls incorporates  
time-tested hydraulically balanced piston,  
seal and spacer design to pilot service flow  
and regeneration  
Large capacity brine tank maximizes time  
between refills  
Fiberglass reinforced resin vessels with NSF  
approved polyethylene liners eliminate worries  
about corrosion  
Single tank design for simplicity, economy  
and space savings  
CES-2750M-34:  
EV9982-21  
MRS-20T System: EV9797-92  
CES-2750M-51:  
CES-2750M-68:  
CES-2750M-101:  
EV9982-22  
EV9982-23  
EV9982-24  
Fully adjustable 5-cycle control delivers  
controlled upflow backwash, downflow brining  
and slow rinse, rapid rinse, timed brine refill and  
downflow service  
4MR-1 Cartridge: EV9273-69  
A P P L I CA T I ON / S I Z I N G  
I N S T A L L A T I ON T I P S  
OP E R A T I ON T I P S  
Check for softened water each time salt is  
added, by using a soap or hardness test kit  
Locate equipment on a smooth, level surface  
Maintain an air-gap at the end of the drain line  
Warewashing  
Laundry - Linen & Uniform  
Boiler Scale Control  
Use a good quality grade of salt -Solar  
or pellet are preferred  
Secure drain line directly over floor drain or  
stand pipe  
Check the salt level on a regular basis  
Water Heater Scale Protection/Reduction  
General Housekeeping  
When connecting to a water heater, install a  
check valve on the soft water piping to prevent  
hot water back-up  
Maintain at minimum salt depth of 6” to  
ensure a proper regeneration  
On iron bearing waters, use a salt that  
contains an iron “fighting” additive, or use  
a resin cleaner on a regular basis  
When sweating/installing copper piping,  
protect the control valve from excessive heat  
Check local codes for additional equipment  
that may be required, such as backflow  
prevention devices (i.e., RPZ)  
Check the water level in the brine tank  
If abnormally high - refer to IO guide for  
troubleshooting information  
 

Cisco Systems Network Router 1600 User Manual
Code Alarm Automobile Alarm CA 1150 User Manual
Code Alarm Automobile Alarm CA 1551 User Manual
Cornelius Ice Maker SID851A 250S User Manual
Cuisinart Coffeemaker DCC 3000 User Manual
Delfield Refrigerator Shelleybasic User Manual
Elation Professional Landscape Lighting Zoom 575E User Manual
Elation Professional Work Light 108IP User Manual
Garmin Cyclometer 190 01632 36_0A User Manual
Gigabyte Network Router RS16000 User Manual