OWNER’S MANUAL
DH-711
BABY’S BREATH™
VAPORIZER
Models DH-711, DH-712, DH-721 and DH-722 Series
INTRODUCTION
®
Thank you for purchasing a Duracraft Baby’s Breath™
Vaporizer manufactured by Honeywell. If you would like
more information on our full line of products please visit our
M O D E L D H - 7 1 1 , D H - 7 1 2 , D H - 7 2 1 a n d D H - 7 2 2
Your vaporizer is made up of two parts:
Steam
Assembly
Base
SET UP
NOTE: We recommend that the humidifier be disinfected prior to first use.
Please see CLEANING instructions.
• Select a firm, level, flat location — at least six inches (15 cm) from any wall
for proper air flow and convenient to an electrical outlet (Fig. 1).
Place vaporizer where it is out of the reach of children. Make sure cord is
not in an area where it can be tripped over or pulled on. Be sure that the
steam outlet is pointed away from any person.
• Place the vaporizer on a water-resistant surface, as water can damage
®
furniture and some flooring. Duracraft will not accept responsibility for
property damage caused by water spillage.
Fig. 1
Fig. 2
WALL
6" minimum
Full Level
Indent
FILLING
1. To remove the Steam Assembly, hold the Base and turn the Steam Assembly
counter-clockwise then pull up.
2. Fill the Base with COOL tap water to the indent marked “Full Level” located on
the back of the unit (Fig. 2). DO NOT USE HOT WATER. Doing so may
damage the vaporizer.
3. Replace the Steam Assembly back onto the Base. Turn it clockwise
to lock in place. Once the Steam Assembly has been positioned, do not
attempt to move vaporizer. If it has to be moved, unplug it and empty the
Base first.
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN
ELECTRIC SHOCK COULD OCCUR.
4. Plug the filled vaporizer into a polarized 120V outlet. DO NOT FORCE THE
POLARIZED PLUG INTO THE OUTLET; it will only fit one way.
OPERATION
IMPORTANT: When your vaporizer is plugged in, it is ON - however it will take
time (20-25 minutes) for the vaporizer to heat the water and produce steam.
The heating process is silent, so the vaporizer will not make any noise until
the water comes to a boil, at which time you may hear a gentle bubbling or
boiling sound.
1. If the Vaporizer does not start producing steam within 25 minutes…
Your water’s mineral content is too low to allow for electrical current flow and
the water will not come to a boil.
• Unplug and remove the Steam Assembly.
• Add 1/4 teaspoon of baking soda per gallon of water (or 1 packet of
Duracraft’s DuraStart following the directions on the package) to help the
water come to a boil. Be sure to thoroughly mix the Baking Soda or
DuraStart with the water in the Base.
NOTE: Adding too much baking soda or DuraStart can cause boiling and/or
hot water spurting, which may cause burns.
2. If the Vaporizer boils excessively, spurts hot water or blows fuses…
Your water’s mineral content is too high.
• Make sure no chemicals have been added to the water. If any chemicals
were added, turn off and unplug the vaporizer. Empty Base and refill with
tap water only.
• If no chemicals have been added, turn off and unplug the vaporizer.
CLean per the cleaning instructions.
• Refill using 1/2 tap water and 1/2 distilled water, which will lower the
mineral content of your water and prevent excessive boiling.
• When you are finished using the vaporizer, unplug it and clean after
each use.
• ALWAYS be sure to discard any unused water in the base before storing
or refilling.
FEATURES
A U T O - S H U T O F F F E AT U R E :
• The vaporizer will shut off when the water level drops below the bottom of
the Steam Assembly.
• Refill the Base per the FILLING instructions.
• Once filled, the vaporizer will automatically turn back on.
M E D I C I N E C U P :
A medicated vapor can be distributed into the air by using the Medicine Cup at
the top of the Steam Assembly.
Fig. 3
Place Medicine Here
To add medicine to the Medicine Cup:
1. Unplug the vaporizer and allow at least 10 minutes for the unit to cool.
2. Carefully add liquid medication; fill cup only halfway (Fig. 3).
3. After use, clean any residue from the cup.
WARNING: DO NOT use any liquid medicine other than those specifically rec-
ommended for use with a steam vaporizer. DO NOT pour medicine directly
into the water as this may cause excessive boiling or spurting of hot water.
Honeywell assumes no responsibility for consequences resulting
from the uses of medication in this vaporizer.
CLEANING
D A I LY
We recommend cleaning the vaporizer daily by wiping all surfaces dry using a
paper towel or soft sponge. It is normal for mineral deposits to collect at the
bottom of the Base. Deposits may appear as black flecks and should be rinsed
out after every use.
W E E K LY
The vaporizer should also be cleaned once a week, according to the instruc-
tions listed below.
Cleaning involves two steps SCALE REMOVAL and DISINFECTING. Be sure to
perform these in the proper order to avoid harmful chemical interactions.
•Unplug the vaporizer. Wait at least 10 minutes for the unit to cool.
•Remove the Steam Assembly and set aside.
•Discard any remaining water from the Base.
•Clean all outside surfaces with a dry, soft cloth. DO NOT USE WATER. THIS
MAY DAMAGE THE VAPORIZER OR CAUSE ELECTRIC SHOCK.
STEP ONE:
STEP TWO:
SCALE REMOVAL
DISINFECTING
1. Fill the Base with either:
• one cup (8 ozs) of undiluted
white vinegar
1. Fill the Base with:
• 1 teaspoon of household bleach
• 1 gallon of water.
OR
• DuraRinse™ Humidifier
Cleaner, part no. AC-816,
following bottle instructions
2. Let stand for 20 minutes.
3. Rinse with water until the odor of
bleach is gone.
2. Let solution stand for 20 minutes.
3. With the vinegar or DuraRinse™
in the Base clean all interior
surfaces with a soft cloth or
brush to help remove scales.
4. Rinse the Base thoroughly with
water to remove scale and
cleaning solution.
NOTE: THE USE OF OTHER WATER TREATMENT PRODUCTS, SOAPS, DETER-
GENTS OR ABRASIVE CLEANERS NOT RECOMMENDED IN THE MANUAL
MAY CAUSE DAMAGE TO THE VAPORIZER OR AFFECT PERFORMANCE.
END-OF-THE-SEASON CARE AND STORAGE
• Follow weekly CLEANING instructions when the vaporizer will not be used
for at least one week or more, or at the end of the season.
• Let the vaporizer dry completely before storing. DO NOT store with water
inside the Base.
• Pack the unit in it’s original carton and store in a cool, dry location.
• Before next use, remember to clean the vaporizer.
ELECTRICAL RATINGS
This DH-711, DH-712, DH-721 and DH-722 are rated 5.0 amps at 120V,
60Hz.
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR VAPORIZER, PLEASE
SEE THE WARRANTY INSTRUCTIONS. PLEASE DO NOT ATTEMPT TO OPEN
OR REPAIR THE VAPORIZER YOURSELF. DOING SO WILL VOID THE WAR-
RANTY AND COULD CAUSE DAMAGE TO THE UNIT OR PERSONAL INJURY.
IF THE PROBLEM PERSISTS PLEASE CONTACT THE CONSUMER SERVICE CEN-
TER.
CUSTOMER ASSISTANCE
Mail questions or comments to:
Honeywell
Consumer Service Center
250 Turnpike Road
Southborough, MA 01772
Please be sure to specify model number.
Call us toll-free at:
1-800-332-1110
Or visit our website at:
TROUBLE SHOOTING
Q: I set up the vaporizer, but it isn’t making any noise. Is it working?
A: The heating process is silent, so the vaporizer will not make any noise until
the water comes to a boil (20-25 minutes), at which time you may hear a
bubbling or boiling sound.
Q: I used the vaporizer last night. When I went to refill it this morning, I
noticed black flecks in the base. Is this normal?
A: It is normal for mineral deposits to collect at the bottom of the Base. It may
appear as black flecks and should be rinsed out after every use. This is nor-
mal and will not affect the operation of the vaporizer if cleaned out daily.
Q: My vaporizer has been plugged in for 30 minutes and still is not
producing steam, what’s wrong?
A: It means that your water’s mineral content is too low to allow for electrical
current flow and the water will not come to a boil.
• Unplug and remove the Heating Assembly
• Add 1/4 teaspoon of baking soda per gallon of water (or 1 packet of
Duracraft’s DuraStart following the directions on the package) to help the
water come to a boil. Be sure to thoroughly mix the Baking Soda or
DuraStart with the water in the Base.
Q: My vaporizer is over boiling and spurting hot water, what’s wrong?
A: It means that your water’s mineral content is too high.
• Make sure no chemicals have been added to the water. If any chemicals
were added, turn off and unplug the vaporizer. Empty the water tank and
refill with tap water only.
• If no chemicals have been added, turn off and unplug the vaporizer.
Clean per the cleaning instructions.
• Refill using 1/2 tap water and 1/2 distilled water, which lower the
mineral content of your water and prevent excessive boiling.
CARE PRODUCTS
®
If your local dealer is out of stock, Duracraft replacement parts and care products
may be ordered directly. You can call 1-800-332-1110 to order with a MasterCard,
Visa or Discover or fill out the form below and mail it along with a check or money
order (sorry no COD’s accepted) to:
Honeywell
Consumer Service Center
250 Turnpike Road
Southborough, MA 01772
Please allow four to six weeks for delivery.
Massachusetts residents please add 5% Sales Tax.
Item
Item No.
Qty.
Total
US Price CAN Price
Base for DH-711
Base for DH-712
DH711-1
DH712-1
$ 6.00
6.00
$8.10
8.10
Base for DH-721
DH721-1
DH722-1
DH711-2
7.00
7.00
8.00
9.45
9.45
10.85
Base for DH-722
Heating Assembly for DH-711
Heating Assembly for DH-712
DH712-2
DH721-2
DH722-2
AC-820
AC-816
8.00
8.00
8.00
5.00
5.00
19.99
10.85
10.85
10.85
6.65
Heating Assembly for DH-721
Heating Assembly for DH-722
DuraStart Vaporizer Steam Starter
DuraRinse™ Humidifier Cleaner (32 oz.)
6.65
Digital Hygrometer and Thermometer (F°/C°) HAC-555
Measure room temperature and humidity level.
Free standing can be used anywhere in the room.
27.00
%
0
30
50
100
DAMP
DRY
COMFORT
SUBTOTAL
MA Residents add 5% Sales Tax/CAN residents only add 7% GST
(US residents add $4.95/CAN residents add $7.00)
Shipping and Handling
TOTAL ENCLOSED
Name
Check or Money Order Enclosed
Address
Credit Card No.
Exp. Date
Day Time Phone
Signature
LIMITED WARRANTY
B A B Y ’ S B R E AT H ™
VA P O R I Z E R
This product has been engineered and crafted with great care for your satisfaction.
Please read all instructions before attempting to use this product. Be sure to fill
out and return the enclosed card within 7 days of purchase.
A.This 3 year limited warranty applies to repair or replacement of product found to
be defective in material or workmanship. This warranty does not apply to dam-
age resulting from commercial, abusive, unreasonable use or supplemental dam-
age. Defects that are the result of normal wear and tear will not be considered
manufacturing defects under this warranty. THE MANUFACTURER IS NOT LIABLE
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY
IMPLIED WARRANTY, INCLUDING MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE
DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion
or limitation of incidental or consequential damages, or limitations on how long
an implied warranty lasts, so the above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights, and you also may have other
rights which vary from jurisdiction to jurisdiction. This warranty applies only to
the original purchaser of this product from the original date of purchase.
B. At its option, the manufacturer will repair or replace this product if it is found
defective in material or workmanship. Defective product should be returned
directly to the manufacturer.
C.This warranty does not cover damage resulting from any unauthorized attempts
to repair or from any use not in accordance with this manual.
D.Return defective product to the place of purchase in accordance with store policy
or to the following address with a brief description of the problem. Include proof
of purchase and a U.S. $7.00/ Can.$9.75 check or money order for handling,
return packing and shipping charges. Please include your name, address and a
daytime phone number. You must prepay shipping charges. Mark
carton“Attention Returns Department.” Ship to:
In the US:
In Canada:
Honeywell
Honeywell
ATTN: Returns Department
Southpoint Distribution Center
4755 Southpoint Drive
Memphis, TN 38118, U.S.A.
1-800-332-1110
ATTN.: Returns Department
510 Bronte Street
Milton, ON L9T 2X6
Canada
©2000 All rights reserved. Honeywell Inc.
P/N: 000-00000-000
HU4018.00
|