CyberData Stereo Amplifier VoIP Paging Loudspeaker Amplifier User Manual |
VoIP Paging/Loudspeaker
Amplifier
Configuration Guide
CyberData Corporation
2555 Garden Road
Monterey, CA 93940
(831) 373-2601
Tech Note
CyberData VoIP Paging Amplifier
Configuration Guide
TN086
August 08
1
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
© 2007‐2008 Objectworld Communications Corp.
All rights reserved. Published August 25, 2008
Objectworld, Objectworld Unified Communications Server, Objectworld UC Server, Objectworld UC Client, Objectworld
Connect, Objectworld Connect PLUS, IT Telephony, and The IT Telephony Company are either trademarks or registered
trademarks of Objectworld Communications Corp. in the United States and/or other countries.
All other trademarks or registered trademarks are property of their respective owners.
2
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
Table of Contents
Preparation...................................................................................................................................................... 7
3.1 PC Network Settings ..................................................................................................................................................7
3.2 CyberData VoIP Paging Amplifier Network Settings .................................................................................................. 8
3.3 Upgrading the firmware............................................................................................................................................. 8
4.1 Gathering Information............................................................................................................................................... 9
4.2 Device Configuration ................................................................................................................................................11
Troubleshooting............................................................................................................................................. 12
3
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
1 Introduction
The CyberData SIP‐enabled VoIP Paging Amplifier provides an easy method for implementing an IP‐based overhead paging
system for both new and legacy installations. The amplifier provides direct drive of a standard horn speaker and supports a
line‐out connector for an external amplifier. The purpose of this guide is to provide instructions on configuring the VoIP Paging
Amplifier with UC Server.
4
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
1.1 Network Topology
Below is an example of how the CyberData VoIP Paging Amplifier might be configured in your network.
5
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
2 Known Integration Issues
Known integration issues include:
•
Cannot perform supervised transfers
Performing a supervised transfer to the paging speaker does not function properly and results in the
o
transferrer indicating a successful transfer even though the transfer was not completed.
6
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
3 Preparation
This section provides instructions about how to apply firmware updates (if necessary) and how to set up the device for manual
configuration.
3.1 PC Network Settings
The factory default on CyberData products is a static IP address. To access the device, you must change your PC to the same
address range.
To change the IP Address for your computer, do the following:
NOTE: Make a note of your original network settings before making any changes because you need to change these settings
back after changing the network configuration on the speaker.
For Windows Server 2003/XP
1. Click Windows Start.
2. Click Control Panel.
3. If you have the classic view, click Network Connections.
If you have the category view, click Network and Internet Connections, and then click Network Connections.
4. Double‐click the active LAN or Internet connection.
5. Click Properties.
6. In the General tab, highlight the Internet Protocol (TCP/IP) item, and click Properties.
7. In the General tab, click Use the following IP address, and enter:
IP Address: 192.168.3.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.3.10
8. Click OK.
For Windows Server 2008/Windows Vista
1. Click Windows Start.
2. Click Control Panel.
3. If you have the classic view, click Network and Sharing Center and then click Manage Network Connections.
If you have the category view, click Network and Internet, View network status and tasks and then click Manage
Network Connections.
4. Double‐click the active LAN or Internet connection.
5. Click Properties.
6. In the Networking tab, highlight the Internet Protocol (TCP/IP) item, and click Properties.
7. In the General tab, click Use the following IP address, and enter:
IP Address: 192.168.3.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.3.10
8. Click OK.
7
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
3.2 CyberData VoIP Paging Amplifier Network Settings
The VoIP Paging Amplifier is configured with a static IP address on factory default. This must be changed so that the device is
connected to your network.
To enter network settings for CyberData VoIP Paging Amplifier
1. Open your browser and type the IP Address of the speaker. The factory default is 192.168.3.10.
2. When prompted, use the following default Web Access username and password:
•
•
Web Access Username:
Web Access Password:
admin
admin
3. Click Network Setup.
4. Under IP Addressing, select DHCP.
5. Click Save Settings.
3.3 Upgrading the firmware
Refer to the Technical Note “TN051 – SIP Device Features and Comparisons” (a versioned document located on the
Objectworld web site at www.objectworld.com/support/documentation) to determine the most recently supported version of
firmware for the zone controller.
The factory firmware version can be found on the check‐off list shipped with your device. If the firmware version on the device
is earlier than the version noted in TN051, upgrade the firmware.
3.3.1
TFTP Firmware Upgrade
1. Retrieve the latest firmware from the CyberData web site. (www.cyberdata.net/support/voip/pagingamplifier)
2. Unzip the file to the Objectworld TFTP folder (located in: X:\Program Files\Objectworld\UC Server\Data\TFTP
where X is the drive where the UC Server program files are installed).
3. Open your browser and type the IP Address of the Paging Amplifier.
4. When prompted, use the following default Web Access username and password:
Web Access Username:
Web Access Password:
admin
admin
5. Click the Upgrade button.
6. Enter the IP address of your UC Server in the TFTP Server IP field.
7. Under New Filename, enter the filename of the rom file you unzipped from the firmware zip file.
For example: 400‐romdisk‐spk‐sip.img
8. Click Upload File.
9. After the rom image file finishes uploading, repeat step 6 but upload the image file by entering the filename of
the image.
For example: 400‐image‐spk‐sip.bin
10. Click Upload File.
11. Click the reboot button.
8
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
4 SIP Configuration
4.1 Gathering Information
To configure the device, you need the following information.
SIP User ID:
This is equivalent to the identity address you want to associate with the device.
Authenticate ID:
This is the SIP authentication identifier associated with the above identity. This is required
by any SIP end‐point to register with the SIP PBX.
Authenticate Password:
This is the SIP authentication password associated with the above identity.
To determine the Authentication ID and Password, do the following:
4.1.1 Determining the Authentication ID and Password as the user (that owns the identity) in UC Client
1. Start UC Client.
2. Login as the user you want to associate to the device.
3. In the bottom left pane, take note of the identity name.
4. Click the icon on the right and select SIP Authentication.
5. Record the User/login name and password from the following dialog because you will need it later to configure
the device.
4.1.2 Determining the Authentication ID and Password as the administrator in UC Client
1. Start UC Client.
9
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
2. Login as the admin user.
3. Select the Identities tab in the left pane.
4. Go to View > Display identities for all Profiles.
5. Find the identity in the list that you want to use and double‐click the entry.
6. Click SIP Authentication.
10
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
7. Record the User/login name and password from the following dialog because you will need it later to configure the
device.
4.2 Device Configuration
1. Open your browser and type the IP Address of the Paging Amplifier.
2. When prompted, use the following default Web Access username and password:
Web Access Username:
Web Access Password:
admin
admin
3. Click the SIP Setup button.
4. Enter the following information:
SIP Server: <IP Address of UC Server>
SIP User ID: <SIP User ID>
SIP Authenticate ID: <SIP User ID>
SIP Password: <Authenticate Password>
SIP Registration: Yes
5. Click Save Settings.
The figure below shows an example of how to complete the required fields.
11
Objectworld Communications Corp. • 308 Legget Drive • Ottawa, ON • Canada • K2K 1Y6 • T: 613‐599‐9698 • F: 613‐599‐7457 •www.objectworld.com
5 Troubleshooting
1. You receive a voicemail prompt when dialing the identity of the device.
Verify the following:
•
•
•
The identity was created in UC Server and the correct User ID and password are configured on the device
See section 4
The SIP Server address on the device is set to the correct IP Address of UC Server
See section 4.2
SIP Registration is enabled on the device
See section 4.2
o
o
o
2. You are unable to access the Web interface to configure the paging device.
Verify the following:
•
Your PC is set to the same address range as the device for first time configuration.
See section 3.1
•
3. No audio when calling into paging device.
Verify the following:
•
The volume level is set correctly on the speaker.
12