Home Standby - 16kW
Air-Cooled Gas Engine Generator Sets
Continuous Standby Power Rating — 16kW 60Hz
Models: ASPBS1CCA016 (Steel)
Ultra Quiet Mode
Low Speed Exercise
59 dB(A) at 23 feet
ASPBA1CCA016 (Aluminum)
INCLUDES:
• Automatic Transfer
Switch With Built-In 16-Circuit
Emergency Load Center
• Electronic Governor
• Pre-wired External
Connection Box
• Flexible Fuel Line
• Composite Mounting Pad
• Pre-wired conduits
• Natural Gas or LP Gas Operation
• UL 2200 Listed to U.S. and Canadian Standards
FEATURES
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of
CARRIER’S success in “IMPROVING POWER BY DESIGN.” But it
doesn’t stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose CARRIER with the confidence that these systems will provide
superior performance.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard
on all models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine.
SINGLE SOURCE SERVICE RESPONSE from Carrier’s dealer network
provides parts and service know-how for the entire unit, from the engine
to the smallest electronic component. You are never on your own when
you own a CARRIER SYSTEM.
TEST CRITERIA:
>
>
>
>
PROTOTYPE TESTED
CARRIER TRANSFER SWITCHES. Long life and reliability are
synonymous with CARRIER. One reason for this confidence is that the
CARRIER product line includes its own transfer systems and controls
for total system compatibility.
SYSTEM TORSIONAL TESTED
NEMA MG1-22 EVALUATION
MOTOR STARTING ABILITY
Home Standby - 16kW
GENERATOR
Model ASPBS1CCA016 - Steel, Model ASPBA1CCA016 - Aluminum
Rated Maximum Continuous Power Capacity (LP)................................................................................................ 16,000 Watts*
Rated Maximum Continuous Power Capacity (NG)............................................................................................... 15,000 Watts*
Rated Voltage.............................................................................................................................................................. 120/240
Rated Maximum Continuous Load Current
120 Volts ........................................................................................................................................................ 133.3 LP/125 NG
240 Volts ....................................................................................................................................................... 66.6 LP/62.5 NG
Main Line Circuit Breaker .......................................................................................................................................... 65 Amp
Phase ............................................................................................................................................................................... 1
Number of Rotor Poles ....................................................................................................................................................
Rated AC Frequency .................................................................................................................................................... 60Hz
Power Factor ....................................................................................................................................................................
2
1
Battery Requirement (not included) .................................................................... Group 26, 12 Volt Netgative Ground and 525 Cold-cranking Amperes Minimum
Unit Weight ................................................................................................................................................ 445 lbs. (Steel), 414 lbs. (Alum)
Dimensions (L” x W” x H”).................................................................................................................................... 48 x 24 x 28-1/4
Sound output in dB(A) at 23 ft. with generator operating at full load.............................................................................. 71.5
Sound output in dB(A) at 23 ft. with generator in Ultra Quiet exercise mode ................................................................ 59
ENGINE
Model ASPBS1CCA016 - Steel, Model ASPBA1CCA016 - Aluminum
Type of Engine........................................................................................................................................................ OHVI V-TWIN
Number of Cylinders.........................................................................................................................................................
2
Rated Horsepower................................................................................................................................................ 30 @ 3,600 rpm
Displacement................................................................................................................................................................ 992cc
Cylinder Block............................................................................................................................................ Aluminum w/Cast Iron Sleeve
Valve Arrangement................................................................................................................................................ Overhead Valve
Ignition System................................................................................................................................................. Solid-state w/Magneto
Governor System........................................................................................................................................................ Electronic
Compression Ratio......................................................................................................................................................... 9.5:1
Starter........................................................................................................................................................................... 12Vdc
Oil Capacity Including Filter................................................................................................................................. Approx. 1.7 Qts.
Standby Operating RPM.............................................................................................................................................. 3,600
Exercise RPM ............................................................................................................................................................. 2400
Fuel Consumption
Natural Gas cu.ft./hr.
........................................1/2 Load
........................................Full Load
Liquid Propane
173
245
ft3/hr (gal/hr)
........................................1/2 Load
........................................Full Load
59 (1.59)
92 (2.51)
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
CONTROLS
Mode Switch
-Auto ...............................................................................................................................................
-Off ............................................................................................................................................
-Manual/Test (start) ......................................................................................................................
Automatic Start on Utility failure
7 day exerciser
Stops unit. Power is removed
Control and charger still operate
Start with starter control, unit
stays on. If utility fails, transfer
to load takes place.
Engine Start Sequence
Cyclic cranking: 7 sec. on, 7 rest
(90 sec. maximum duration)
Engine Warm-up ..................................................................................................................................................... 10 seconds
Engine Cool-Down ..................................................................................................................................................... 1 minute
Starter Lock-out ........................................................................................................................................ Starter cannot re-engage until
5 sec. after engine has stopped.
2.5 Amp Timed Trickle Battery Charger .................................................................................................................. Standard
Automatic Voltage Regulator w/Overvoltage Protection ............................................................................................ Standard
Automatic Low Oil Pressure Shutdown ..................................................................................................................... Standard
Overspeed Shutdown ............................................................................................................................................ Standard, 72Hz
High Temperature Shutdown ..................................................................................................................................... Standard
Overcrank Protection ................................................................................................................................................. Standard
Safety Fuse ............................................................................................................................................................... Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with
BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum
power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Home Standby - 16kW
Transfer Switch Features
TRANSFER SWITCH & EMERGENCY LOAD CENTER
Models: ASPBS1CC016 & ASPBA1CC016
No. of Poles .........................................................................................................................................
2
• Electrically operated,
mechanically-held contacts for
fast, positive connections.
Current Rating (amps) ....................................................................................................................... 100
Voltage Rating (VAC) ........................................................................................................................ 250
Utility Voltage Monitor (fixed)
-Pick-up
-Dropout
Return to Utility
................................................................................................... 70%
................................................................................................... 60%
.................................................................................................... approx. 13 sec.
• Rated for all classes of load,
100% equipment rated, both
inductive and resistive.
Exerciser weekly for 12 minutes .................................................................................................... Standard
UL Listed ....................................................................................................................................... Standard
Dimensions (H” x W” x D”) ....................................................................................................... 26.5 x 12.5 x 7
Total of Pre-wired Circuits .................................................................................................................. 16
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
No. 15A 120V ................................................................................................................
No. 20A 120V ................................................................................................................
No. 20A 240V ................................................................................................................
No. 40A 240V ................................................................................................................
No. 50A 240V ................................................................................................................
5
5
1
1
1
Circuit Breaker Protected
Available RMS Symmetrical
• Main contacts are silver plated
or silver alloy to resist welding
and sticking.
Fault Current @ 250 Volts .................................................................................................... 10,000
• Nema 1 enclosure is standard
on the 100 amp switch.
Mechanical Dimensions (in inches)
W2
Current
No. of
Height
H2
29.25
Width
W2
12.5
Depth
7
W1
Rating
Poles
H1
W1
100 UL Listed
2
26.5
8.14
Terminal Wire Ranges
ATS Rated Amps
Switch Terminal
1 x 1/0-12
Neutral Lug/Stud
1 x 3/8-16 Stud
Ground Lug
1 x 2/0-14
H1
H2
100A 2-Pole UL
Conduit sizes
vary depending
on model #
C A R R I E R , I N C .
•
7 3 1 0 W E S T M O R R I S S T R E E T
•
I N D I A N A P O L I S , I N 4 6 2 3 1
W E B S I T E : w w w . c a r r i e r . c o m
CarrierAC16kW 9.06
CATALOG NO. ASPBS16-1SS
© 2006 Carrier Corporation. All rights reserved. All specifications are subject to change without notice.
|