Braun Thermometer 950787 User Manual

Vistabasic  
Instructions for Use  
Rx Only  
950787 Rev H 02/03  
 
Vistabasic  
Contents  
CONTENTS  
Warnings & Cautions.................................................................. 3  
Introduction ................................................................................ 5  
Preparing the Infusion ................................................................ 7  
Continuous Mode....................................................................... 8  
Options: Piggyback.......................................................................... 11  
Ramp/Taper Mode............................................................ 12  
Program Mode............................................................ 14  
Delay A Mode ................................................................... 15  
Dosage Calculation........................................................... 16  
Bolus Mode, Interval Bolus (Intermittent Mode)................ 17  
Total Infused, Standby................................................. 18  
Occlusion Pressure, Drop Sensor, Battery ....................... 19  
Data Lock, Contrast Selection .......................................... 20  
Adjust Clock, Loudness .................................................... 21  
Alarms........................................................................................ 22  
AC, 12V, Battery, & CC Interface............................................... 23  
Maintenance, Storage, & Service............................................... 24  
Specifications............................................................................. 25  
The Vista basic is a volumetric infusion  
pump intended to provide accurate and  
continuous flow of parenteral and  
enteral fluids.  
Qualified medical staff should decide  
how the device should be used based  
on its features and specifications.  
For more details, please read the  
Instructions for Use.  
Rx only.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
2/25  
 
WARNINGS & CAUTIONS  
The following should be observed to avoid patient/user injury. This Instructions  
for Use manual contains detailed instructions and warnings on the use of the  
Vistabasic Infusion Pump. Please read it completely prior to using this device.  
This manual is intended to reinforce the teaching given to the user by a trained  
health care professional or an authorized B. Braun representative.  
WARNINGS  
Do not operate this device in  
environments where there is an  
explosion hazard! A possible  
explosion hazard exists if the pump  
is used in the presence of  
B. Braun will assume no  
responsibility for incidents which  
may occur if the product is not used  
in accordance with product labeling.  
flammable anesthetics.  
Make sure the pump is stable, either  
fastened securely to the IV pole or  
resting on a flat surface.  
The EMC-limits (Electro-magnetic  
compatibility) according to IEC/EN  
60601-1-2 and IEC/EN 60601-2-24  
are maintained. If the equipment is  
operated near other equipment  
which may cause high levels of  
interference (e.g. HF surgical  
equipment, nuclear spin tomography  
units, mobile telephones, etc.)  
maintain the recommended  
protective distances for these  
devices. Under certain conditions,  
malfunctions may occur which lead  
to a device alarm with permanent  
alarm tone. Interference may occur  
e.g. at electro-magnetic fields > 10  
[V/m] resp. electro-magnetic  
Prior to use, always check the  
audible and visual alarms (and staff  
call, where applicable).  
Connection of pump tubing to the  
patient should only be made after  
the tubing is loaded and the unit is  
turned on. Disconnect tubing from  
patient when changing solution  
containers to avoid the danger of  
incorrect dosage.  
Ensure there are no kinks in the  
tubing.  
Always read and follow the  
instructions that accompany the  
source container and IV  
discharges > [8 kV].  
administration sets you are using.  
Carefully follow the instructions for  
loading, removing, and reloading the  
set, as well as the recommended set  
change intervals.  
Monitoring of the patient and  
infusion status is necessary to  
ensure the infusion is being  
delivered as anticipated. The Vista  
basic has been designed to stop  
fluid flow to the patient under certain  
alarm conditions. Also, prior to  
starting an infusion, verify that no  
drops are falling in the drip chamber  
and the programmed information is  
correct.  
Change pumping section on tubing  
every 24 hours. Do not use tubing  
for more than 72 hours or per  
current facility protocol.  
Always check pump data prior to  
starting infusion.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
3/25  
 
WARNINGS & CAUTIONS  
After starting an infusion, make sure  
drops are falling in the drip chamber.  
If no drops are falling, make sure the  
roller clamp is open. If the roller  
clamp is open and still no drops are  
falling, replace and dispose of the  
set.  
Use only equipment, accessories,  
parts, and disposables that are  
intended for use with the Vista  
basic.  
Do not clean, disinfect, or sterilize  
any part of the device by autoclaving  
or with ethylene oxide gas. Doing  
so may damage the device and void  
the warranty. Only external parts of  
the pump should be disinfected.  
See “Maintenance, Storage, &  
Service” for suggested cleaning  
solutions.  
The air detector cannot recognize  
the introduction of air at 3-way  
stopcocks, infusion ports, and other  
lines/tubes below the pump.  
See section entitled “Drop Sensor”  
for additional information on using  
the device without a drop sensor.  
Technical specifications are not  
guaranteed with any other tubing  
than that approved for use with the  
Vista basic.  
To avoid mechanical or electronic  
damage, do not steam autoclave or  
immerse the pump in any fluids or  
cleaning solutions. Always  
disconnect electrical power cord  
from outlet before cleaning to  
prevent electrical shock.  
Any analog and digital components  
connected must demonstrate that  
they meet EN specifications (i.e. EN  
60950 for data processing  
equipment and EN 60601 for  
electrical medical equipment).  
CAUTIONS  
Only an authorized system  
Rx only.  
configuration technician responsible  
for meeting the specifications of  
standard EN 60601-1-1 may  
connect additional devices to the  
signal inputs or outputs.  
Do not attempt to infuse two fluids  
simultaneously using the Vista™  
basic.  
Variations in pressure, e.g. caused  
by change in level of fluid container,  
may affect the accuracy of the  
device.  
SAFETY STANDARD  
The Vista basic meets all safety  
standards for medical electrical devices,  
corresponding to IEC 60601-1 and IEC  
60601-2-4.  
NOTE: IEC 60601-1 corresponds to  
European Standard EN 60601.  
If several pieces of infusion  
equipment are connected together,  
it is possible there may be mutual  
influence. Possible incompatibilities  
can be found in the instructions for  
use for the drug or for the other  
appliances.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
4/25  
 
INTRODUCTION  
Handle for carrying  
Display  
All essential information is  
displayed in plain language.  
Green background lighting  
illuminates only when  
connected to AC power, or, in  
battery operation, only when a  
key is pressed.  
Clear Key  
Keyboard  
Allows data entry  
Resets a  
value to  
zero  
Alarm Light  
Lights up during an alarm.  
Display will also show  
flashing AAA.A.  
Infusing Light  
Indicates pump is infusing  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
5/25  
 
INTRODUCTION  
Door Open Button  
Aluminum Case  
Easy upkeep, drip proof, and  
resistant to disinfectants  
Function Keys  
Allow choices of YES, NO, OK,  
INFO, OPTS, etc.  
ON/OFF (Power) Key  
Alarm Silence Key  
Silences alarm tone for 2  
minutes  
START/STOP Key  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
6/25  
 
PREPARING THE INFUSION  
Prepare the Pump  
1. Check for cleanliness, completeness, and damage. If unit appears  
damaged, do not use it.  
2. Attach the pump to an IV pole by turning the knob on the pole clamp  
clockwise, or place the pump on a flat, stable surface.  
3. Plug the pump’s power cord into an electrical outlet.  
Turn on the Pump  
1. Press  
(ON/OFF).  
2. Listen for 3 loud beeps.  
3. Check screen for completeness of all pixels on the display. The Alarm ()  
and Infusing (6) lights will blink once.  
Load the Set  
1. Prepare the solution container and prime the administration set according to  
the instructions provided on the set package. Close the roller clamp.  
2. Check that the drip chamber is about 1/3 full  
and there is no air in the set.  
3. Open the pump door by pressing the Door  
Open Button on the top right corner of the  
pump.  
4. Push and hold open the clamp at the top of  
the fluid path.  
5. Insert tubing in clamp and release clamp.  
6. Thread the tubing down the fluid path, making  
sure the tubing is pressed into the Air-in-Line  
detector at the bottom of the fluid path. The  
roller clamp should be below the pump.  
7. Close the door and open the roller clamp.  
Check that no drops are falling in the drip  
chamber.  
8. Place drop sensor on drip chamber (optional).  
9. Connect set to patient site.  
Turning off the Pump  
1. Press  
to stop the infusion.  
2. Close the roller clamp.  
3. Press and hold  
for 2 seconds.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
7/25  
 
Continuous Mode  
When the pump is turned on, it may display: Tubing Type VISTA Pump Set  
Confirm you are using a Vista™ Pump Set, then press YES.  
The pump may then display: Is This a New Therapy?  
YES  
NO  
Begins in Continuous Mode with all  
data cleared.  
Returns to the beginning of the last  
program with all data retained.  
The pump may then display: Prime Set?  
YES  
YES  
Press YES to begin priming set.  
Press YES to begin priming set.  
Press STOP to end priming.  
Press STOP to end priming.  
Press EXIT to begin Continuous  
Mode.  
Press EXIT to return to the  
beginning of the last program with  
all data retained.  
NO  
NO  
Returns to the beginning of the last  
program with all data retained.  
Begins in Continuous Mode with all  
data cleared.  
Press the green key below your  
answer.  
CONTINUOUS MODE  
This section explains how to program a Continuous Mode infusion. For  
directions on how to program other Modes and Options, refer to those sections  
later in this manual.  
There are three ways to enter infusion data in Continuous Mode:  
RATE and VTBD (Volume To Be Delivered)  
1. Enter rate in ml/hr.  
2. Press VTBD (Volume To Be Delivered).  
3. Enter bag volume in ml.  
4. Press OK. (To leave screen without saving changes, press EXIT.)  
5. Press  
to begin the infusion. Check for drops in the drip  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
8/25  
 
Continuous Mode  
chamber.  
VTBD and TIME  
1. Press VTBD.  
2. Enter bag volume in ml.  
3. Press OK. (To leave screen without saving changes, press EXIT.)  
4. Press TIME.  
5. Enter infusion time in hours and minutes.  
NOTE: For a 2 hour infusion, enter 2, 0, 0. The pump will show: Time: 02h00m  
6. Press OK. (To leave screen without saving changes, press EXIT.) The  
pump calculates the rate and asks: Accept Rate?  
7. Press OK.  
8. Press  
to begin the infusion. Check for drops in the drip  
chamber.  
RATE and TIME  
1. Enter rate in ml/hr.  
2. Press TIME.  
3. Enter infusion time in hours and minutes.  
4. Press OK. (To leave screen without saving changes, press EXIT.)  
5. Press  
to begin the infusion. Check for drops in the drip  
chamber.  
To Change the Rate  
1. Press  
to stop the infusion.  
2. Press  
. The display will reset to 000.0 ml/h.  
3. Enter a new rate.  
4. Press  
to begin the infusion. Check for drops in the drip chamber.  
To Change the Rate While Infusing  
1. Enter a new rate.  
2. Press OK.  
NOTE: If the OK key is not pressed within 10 seconds of the change, the infusion will  
continue at the old rate.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
9/25  
 
Continuous Mode  
KEEP VEIN OPEN RATE  
After an infusion is complete, the pump will alarm and begin pumping at 1.0 ml/hr  
or the current infusion rate, whichever is less.  
1. Stop the infusion.  
2. Turn off the pump or reset the program.  
INFORMATION KEY  
This key is only available while the pump is infusing.  
1. Press INFO.  
2. The Total Infused value and the Total Time of the infusion completed are  
displayed.  
3. Press INFO again and the Battery Left and Total Operation time of the pump  
is displayed.  
4. The pump will return to the main infusion screen after 10 seconds.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
10/25  
 
OPTIONS  
Piggyback  
The Vistabasic contains many options to allow custom programming. To  
access the various options, press OPTS while the pump is stopped. Pressing  
OPTS each time will move you to the next option. Eventually, the OPTS key will  
bring you back to the mode from which you began.  
Depending on the model, some modes/options may have been disabled and will  
not appear on the display when the OPTS key is pressed.  
PIGGYBACK  
The Piggyback feature allows programming of a secondary (Piggyback) infusion.  
The pump automatically switches from the Piggyback to the Continuous Mode  
infusion when the Piggyback program is complete. The option is only available if  
there is data in the Continuous Mode.  
1. Connect the Piggyback set to the injection site on the  
tubing above the pump on the primary set. Open the  
roller clamp on the Piggyback set.  
2. Hang the Piggyback solution container at least 8 inches  
above the primary solution container.  
3. Program the continuous infusion in the Continuous Mode  
(see “Continuous Mode”).  
4. Press OPTS.  
5. Press ON to turn the Piggyback feature on.  
6. Press END. PIGY will now be displayed in the lower left corner.  
7. Press PIGY.  
8. Enter the Piggyback infusion data as you would Continuous Mode data.  
9. Press  
to start the Piggyback infusion.  
10. Check that drops are falling in the Piggyback drip chamber.  
CAUTION: Do not attempt to infuse both Continuous and Piggyback fluids at the same time. Use  
primary sets with check valves.  
NOTE: To prevent incorrect delivery, the programmed Piggyback volume to be delivered must equal  
the amount of fluid in the Piggyback container. Automatic Piggyback is not intended for the infusion  
of fluids requiring flushing before and after administration.  
NOTE: If the Piggyback container is not empty, the remaining Piggyback fluid will be delivered at the  
Continuous Mode rate once the pump transitions back to the Continuous Mode.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
11/25  
 
OPTIONS  
Piggyback, Ramp/Taper Mode  
To Exit Piggyback  
1. Press  
to stop the infusion.  
2. Press END.  
3. Press OPTS.  
4. Press OFF to turn Piggyback off  
5. Press END to return to Continuous Mode.  
RAMP/TAPER MODE  
The Ramp/Taper Mode is designed to deliver infusions, such as Total Parenteral  
Nutrition (TPN), which require gradual ramp up and taper down rates. The pump  
automatically calculates the rate changes required to match the volume, total  
time, and ramp/taper time parameters.  
1. Press OPTS until display shows RAMP TAPER MODE.  
2. Press ON.  
3. Enter the total bag VOLUME to be delivered.  
4. Press OK.  
5. Enter the RAMP UP time, in hours and minutes.  
NOTE: The pump defaults to 01h00m. To change, press  
, and enter the time.  
, and enter the time.  
6. Press OK.  
7. Enter the TAPER DOWN time, in hours and minutes.  
NOTE: The pump defaults to 01h00m. To change, press  
8. Press OK.  
9. Enter the TOTAL Time for the infusion.  
10. Press OK  
Note: The pump calculates the maximum rate and asks: Accept Rate?  
11. Press OK.  
12. Press  
to start the infusion. Check for drops in the drip chamber.  
To Review or Change Ramp/Taper Mode Data  
1. Press OPTS until display shows RAMP TAPER MODE.  
2. Press ON.  
3. Review the data on each screen and press OK if data is correct or press  
to clear the current data and re-enter new data. Press OK to accept  
new data.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
12/25  
 
OPTIONS  
Ramp/Taper Mode  
To Clear Ramp/Taper Mode  
1. Press OPTS until display shows RAMP TAPER MODE.  
2. Press CLR.  
3. Press YES to clear all the data in Ramp/Taper Mode.  
4. Press ON and continue to program a new Ramp/Taper program.  
To Exit Ramp/Taper Mode  
1. When infusion is complete, press  
2. Press EXIT.  
to stop the KVO.  
3. Press END to return to Continuous Mode.  
Fast Taper  
The infusion can be interrupted to begin an early taper down process during the  
Ramp/Taper Mode Infusion.  
1. Stop the infusion.  
2. Press FAST.  
3. Enter the FAST Taper Time in hours and minutes.  
4. Press OK.  
5. Press  
to start the infusion. Check for drops in the drip chamber.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
13/25  
 
OPTIONS  
Program Mode  
PROGRAM MODE  
Program Mode is for infusions requiring up to 9 separate rates and volumes to be  
delivered one after another. This is designed to deliver infusions for stepped  
oncology drugs, circadian medication delivery, and other custom programs.  
1. Press OPTS until display shows PROGRAM MODE.  
2. Press ON.  
3. Enter the rate of the first Step.  
4. Press OK.  
5. Enter the volume of the first Step.  
6. Press OK.  
7. Continue to enter the rates and volumes for Steps 2-9.  
8. If less than 9 Steps are needed, press OK with a rate of zero.  
9. Press OK to accept the total Program Volume.  
NOTE: Pressing CHNG on this screen returns to Step 1 for review and changes.  
10. Press  
to start the infusion. Check for drops in the drip chamber.  
To Review or Change Program Mode data  
1. Press OPTS until display shows PROGRAM MODE.  
Note: If Program Mode is infusing, stop the infusion and press EXIT.  
2. Press ON.  
3. Review the data on each screen and press OK if data is correct or press  
to clear the current data and re-enter new data. Press OK to accept  
new data.  
4. OR, press CHNG on Accept Program Volume screen (see #9 NOTE above).  
To Clear Program Mode  
1. Press OPTS until display shows PROGRAM MODE.  
Note: If Program Mode is infusing, stop the infusion and press EXIT.  
2. Press CLR.  
3. Press YES to clear all the data in Program Mode.  
4. Press ON and continue to program a new Program.  
To Exit Program Mode  
1. When infusion is complete, press  
2. Press EXIT.  
to stop the KVO.  
3. Press END to return to Continuous Mode.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
14/25  
 
OPTIONS  
Delay A Mode  
DELAY A MODE  
The start of Continuous, Piggyback, Ramp/Taper, and Program Modes may all  
be delayed. The Vistabasic also provides an option to extend the Infusion  
Complete alarm at the end of the infusion.  
1. Program the infusion.  
2. Press OPTS until display shows DELAY A MODE.  
3. Press ON.  
4. Enter in how many hours and minutes the infusion should begin.  
NOTE: This is NOT a clock time like 12:30 pm.  
5. Press OK.  
6. Enter how long, in hours and minutes, after the end of the infusion the pump  
should wait before alarming.  
7. Press OK.  
8. Press YES if the pump should run at KVO during the delay times. Press NO  
if the pump should not infuse during the delay times.  
9. Review the data and press OK. To change the data, press EXIT and begin  
with #3 above.  
10. Press  
to begin the delayed infusion.  
To Exit Delay A Mode  
1. Stop the infusion.  
2. Press OPTS until display shows DELAY A MODE.  
3. Press OFF.  
4. Press END to return to the previously active mode.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
15/25  
 
OPTIONS  
Dosage Calculation  
DOSAGE CALCULATION  
This feature allows a rate to be calculated given the concentration and dose.  
1. Press OPTS until display shows DOSAGE CALC.  
2. Press ON.  
3. If concentration unit desired is other than the one displayed, press button  
under the mcg? until units desired appear in the CONCENTRAT. (0*/ml) line.  
4. Enter the concentration of the solution. If the concentration of the solution is  
not known, go to #6 below. Press C to clear current data and re-enter new  
data.  
5. Press OK.  
6. To calculate the concentration of the solution, use to move the * to the mg  
field. Enter the amount of drug in the solution. Then press to move the *  
to the ml field. Enter the amount of solution.  
7. Press OK.  
8. Enter the body weight if part of the dosing parameters, then press OK. If  
body weight is not part of the dosing parameters, press OK with 0 in the body  
weight field.  
9. If time unit desired is other than the one displayed, press button under the  
/h? until time unit desired appears in the first line. Enter the dose or use Æ to  
move the * to the rate field and enter the rate.  
10. Press OK.  
11. Press  
to begin the infusion.  
To Review Data During Infusion  
1. Press INFO twice.  
To Exit Dosage Calculation  
1. Stop the infusion.  
2. Press OPTS until display shows DOSAGE CALC.  
3. Press OFF.  
4. Press END.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
16/25  
 
OPTIONS  
Bolus Mode, Interval Bolus (Intermittent Mode)  
BOLUS MODE  
This feature allows a bolus to be given during a Continuous Mode infusion.  
1. Press OPTS until display shows BOLUS MODE.  
2. Press ON.  
3. Press RATE.  
4. Enter the rate at which the bolus should infuse, then press OK.  
5. Press END.  
6. To give a bolus during the infusion, press BOL.  
7. Enter the amount of bolus to be given in ml.  
8. Press OK.  
Bolus Without Entering a Volume  
1. During the infusion, press BOL and hold down until a second BOL is  
displayed to the right.  
2. Continue to hold down the first BOL while also pressing the second BOL.  
A bolus will be given as long as both BOL keys are held down. The pump  
will display the amount of bolus being administered and will beep once after  
each milliliter delivered.  
INTERVAL BOLUS (INTERMITTENT MODE)  
The basal/KVO rate and entire bag volume must be entered in CONTINUOUS  
MODE first.  
1. Press OPTS until display shows BOLUS MODE.  
2. Press ON.  
3. Press TIME.  
4. Enter the time between the start of each dose, then press OK.  
5. Press RATE.  
6. Enter the rate at which the dose is to be given, then press OK.  
7. Press VTBD.  
8. Enter the volume of each dose, then press OK.  
9. Press END.  
10. Press  
. The pump will deliver at the basal/KVO rate for the interval  
time, then begin delivery of the first dose.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
17/25  
 
OPTIONS  
Total Infused, Standby Function  
TOTAL INFUSED  
The Total Infused information screen displays the total amount of fluid in ml that  
has been pumped since the last time the Total Infused was cleared.  
To Clear the Total Infused  
1. Press OPTS until display shows Tot Infused=.  
2. Press  
.
3. Press END.  
STANDBY  
This function allows the pump to be put on standby while retaining all set infusion  
data. This function is only available in Continuous Mode.  
1. Press OPTS until display shows STANDBY  
2. Press ON.  
3. Enter time in hours and minutes the pump is to stand by.  
4. Press C to clear the current data and re-enter new data. Press OK to  
accept new data.  
4. Press OK.  
The pump will count down to zero and then alarm Pump Stopped!  
To Exit Standby Function  
1. Press EXIT to return to Continuous Mode.  
Note: If countdown has already started, press END to return to Continuous  
Mode.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
18/25  
 
OPTIONS Occlusion Pressure, Drop Sensor, Battery  
OCCLUSION PRESSURE  
The pressure at which a downstream occlusion alarm will be triggered may be  
varied. The higher the pressure limit, the less sensitive the pump is to changes  
in fluid resistance.  
1. Press OPTS until display shows OCCLUSION PRESSURE.  
2. Press (--) to change pressure to Low. Press (+) to change pressure to High.  
3. Press END to return to Continuous Mode.  
NOTE: Low corresponds to approximately 8 PSI and high to approximately 17 PSI.  
High pressure limits may increase the severity of an infiltration without alarming.  
DROP SENSOR  
Using a drop sensor eliminates the need for pre-setting a VTBD in Continuous  
Mode and senses upstream occlusions and empty solution containers.  
NOTE: Turning the Drop Sensor feature off forces volumes to be entered and prevents  
sensing of upstream occlusions.  
To Turn On the Drop Sensor  
1. Press OPTS until display shows DROP SENSOR.  
2. Press ON.  
3. Press END to return to Continuous Mode.  
To Turn Off the Drop Sensor  
1. Press OPTS until display shows DROP SENSOR.  
2. Press OFF.  
3. Press END to return to Continuous Mode.  
BATTERY CAPACITY  
This is an indicator of the remaining battery time in hours and minutes. This  
screen also indicates the amount of time the pump has been in operation.  
1. Press OPTS until display shows Battery Left =.  
2. Press END to return to Continuous Mode  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
19/25  
 
OPTIONS  
Data Lock, Contrast Selection  
DATA LOCK  
This features prevents unauthorized use by locking out all keys except  
,and  
,
.
1. Press OPTS until display shows DATA LOCK.  
2. Press ON.  
3. Press END to return to Continuous Mode.  
To Turn Off Data Lock  
1. Press OPTS until display shows DATA LOCK.  
2. Press the decimal key.  
3. Press OFF.  
4. Press END to return to Continuous Mode.  
CONTRAST SELECTION  
This feature allows the contrast of the screen to be changed for best possible  
viewing.  
1. Press OPTS until display shows CONTRAST SELECTION.  
2. Press (+) to increase the contrast (make the text darker). Press (--) to  
decrease the contrast (make the text lighter).  
3. Press END to return to Continuous Mode.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
20/25  
 
OPTIONS  
Adjust Clock, Loudness  
ADJUST CLOCK  
This feature allows the time and date to be changed.  
1. Press OPTS until display shows ADJUST CLOCK.  
2. Press DAT to enter the date. (Press C to clear the current data and re-  
enter new data.)  
3. Enter the date using two digits for month, day and year.  
Example: November 5, 2001 is entered as 11 05 01  
4. Press OK  
5. Press TIME to enter the time of day.  
Note: The time is set using 24 hour Military Time.  
Example: 6:30pm is entered as 18:30  
6. Press OK  
7. Press END to return to Continuous Mode.  
LOUDNESS  
This feature allows the volume of the alarm tone to be changed.  
1. Press OPTS until display shows LOUDNESS.  
2. Press (+) to increase the alarm volume. Press (--) to decrease the volume.  
3. Press END to return to Continuous Mode.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
21/25  
 
OPTIONS  
Alarms  
In alarm situations, press  
the infusion by pressing  
to silence the alarm. Correct the problem. Resume  
.
Alarm  
Possible Cause  
Action  
Air-In-Line!  
Air bubble in air-in-line sensor  
Remove air from system  
Check Drop  
Sensor!  
Free Flow!  
Solution container empty  
Roller clamp closed  
Set loaded incorrectly  
Replace solution container  
Open roller clamp  
Re-load set  
Not Enough Drops!  
Too Many Drops!  
Kinks, closed clamps, or  
blockage  
Check for blockage  
Droplets on wall of drip chamber  
Drop sensor out of position  
Shake drip chamber  
Reposition drop sensor  
Door Open!  
Door opened during infusion  
Close door  
Dwnstream  
Occlusion!  
Downstream tubing kinked  
Filter blocked  
Closed clamp  
Correct kinks  
Correct blocked filter  
Open clamps  
IV positional or infiltrated  
Catheter or vein too small  
Occlusion limit too low  
Check IV site  
Increase occlusion limit  
Invalid data!  
Entered data is out of range  
Press  
; re-enter data  
Keep Vein Open  
Rate: Infusion  
Complete  
Programmed infusion is  
complete  
Stop infusion  
Low Battery!  
30 minutes until battery is fully  
discharged  
Silence alarm and connect  
pump to AC power  
Plug In Now!  
Battery is discharged  
Connect pump to AC power  
Silence alarm; begin infusion  
Pump Stopped!  
No key panel activity for 2  
minutes or Standby time expired  
Unit Malfunction!  
Internal error  
Press  
until display reads:  
“Do not press any key until  
display is off;” wait until pump  
turns off, turn device on. If  
alarm repeats, return for  
service.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
22/25  
 
AC, 12 V, BATTERY, & CC INTERFACE  
AC and 12 V  
CC Interface  
Interface descriptions available from  
B. Braun. Connection to interface  
input uses MFC plug.  
Check AC voltage as per  
rating label.  
Insert/screw on power lead  
(12 V lead in ambulance car)  
on back.  
Documentation  
All operating data of the  
Vistabasic can be called up  
and logged via external  
computer  
Battery Operation  
Switching to internal battery is  
automatic in the event of  
power failure or if 12 V or AC  
is not connected.  
Charge battery on initial use,  
following a battery alarm, or  
after 2 months of non-use.  
Charging time: approx. 16  
hours. Longer charging has  
no detrimental effect.  
Full battery provides operation  
for 3.5 hours at 125 mL/hr.  
Battery capacity is approx.  
50% after 2 years.  
The service life of the battery  
can be extended by  
completely discharging it from  
time to time and then fully  
recharging it on AC power.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
23/25  
 
MAINTENANCE, STORAGE, & SERVICE  
Maintenance  
Storage  
Clean the pump with a soft, lint-free  
cloth or swab dampened with soap  
and water, a general non staining  
chemical disinfectant, isopropyl  
alcohol (15%), derivatives of  
phenylphenol (5%) or ammonium  
chloride (10%).  
Store the pump away from excessive  
heat, cold, or humidity. Keep devices  
plugged into electrical power during  
storage.  
Service  
If the pump fails to respond to the  
operating or troubleshooting procedures  
listed in this manual and the cause  
cannot be determined, discontinue use  
and forward it to an authorized B. Braun  
Service Center.  
As a general recommendation for  
cleaning and disinfecting this  
device, use a lint-free cloth  
dampened (not soaked) with a 0.5%  
bleach (Sodium Hypochlorite)  
solution (10% solution with water).  
The solution is most effective when  
prepared weekly and allowed to  
remain on the device for  
Should it be necessary to return a pump  
for repair, contact Technical Support at  
B. Braun Customer Service at 800-627-  
PUMP. A Returned Materials  
approximately 10 minutes prior to  
wiping off.  
Authorization number will be provided.  
Carefully pack the pump (preferably in  
the original packing) and ship it prepaid  
to:  
Do not use acetone solutions  
containing glutaraldehyde or  
abrasive cleansers on the  
pump. If necessary, Betadine  
or Iodine solutions may be  
used, but they will stain the  
pump.  
B. Braun Medical Inc.  
Attn: Service Manager  
1601 Wallace Drive  
Suite 150  
Carrollton, TX 75006 USA  
Do not use abrasive cleaning  
tools or pressurized spraying  
devices as these may damage  
the device.  
Do not sterilize the pump using  
ethylene oxide (EtO) gas.  
Do not steam autoclave or  
immerse the pump in any fluids  
or cleaning solutions.  
B. Braun cannot assume responsibility  
for loss or damage to returned pumps  
while they are in transit.  
Product complaints may be sent to the  
Quality Manager at the above address.  
With each complaint, please include  
pump serial number and full description  
of difficulty, including all settings, types  
of fluids, times, and alarm messages.  
Return set used if possible. Contact  
Technical Support for an RMA number  
prior to return.  
Always turn off the pump and  
disconnect it from the electrical  
outlet prior to cleaning.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
24/25  
 
SPECIFICATIONS  
Mechanism  
Dimensions WxHxD  
Weight  
Linear peristaltic volumetric infusion pump  
5.5 in (14cm) x 9.4 in (24cm) x 7.8 in (20cm)  
6.8 lbs. (3.1 kg)  
Power Requirements  
Leakage Current  
Battery  
Battery Operating Time  
Rate Range  
100-120 VAC, 50-60 Hz, 13 Watts  
Max 30µA  
7.2V, 1.2 Ah NiCd (rechargeable)  
=3.5 hours at 125 mL/hr  
0.1 to 800.0 mL/hr in 0.1 mL increments with Vista™  
tubing  
Volume to be Infused  
Range  
0.1 to 9999.9 mL  
Occlusion Pressure  
KVO Rate  
Flow Rate Accuracy  
Alarms  
Variable Settings Low: 8 PSI High: 17 PSI  
1 mL/hr or selected rate, whichever is lower  
± 5% measurement time 8hr, temp. 71.6° F  
Air-in-Line, Low Battery, Plug In Now, Bag Empty,  
Downstream Occlusion, Door Open, Pump Stopped,  
KVO, Unit Malfunction  
Air-in-Line Alarm  
Memory  
Air bubble size 0.3mL* or 1.5mL/hr**  
*Can be set from 0.01 to 0.3 mL in service  
program  
**Can be set from 0.5 to 3.5 mL/hr in service  
program  
User option to retain last Continuous and Piggyback  
Mode data upon power up. Permanent data  
retention in Program and Ramp/Taper Modes after  
pump is turned off  
Tubing  
Modes/Features  
B. Braun Vista™ administration sets  
Continuous and Piggyback Modes, Program Mode  
for variable infusions, Ramp/Taper Mode for TPN  
infusions and Delay A Mode for postponing infusion  
start and finish  
Operating  
Temperatures  
Operating: 64.4° F to 95° F, 10.15 PSI to 15.37PSI  
Non-Operating: -13° F to 131° F, 10.15 PSI to  
15.37 PSI  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
25/25  
 
B. Braun Medical Inc.  
824 Twelfth Ave.  
Bethlehem, PA 18018  
Tel 800-227-2862  
©2001 B. Braun Medical Inc.  
Vistabasic Instructions for Use  
950787 Rev H 02/03  
 

Black Box Network Hardware ACU1022A User Manual
Bosch Appliances Home Security System DS938Z User Manual
Bose Headphones On Ear Headphone User Manual
Braun Mixer MR 5500 M User Manual
Breckwell Fire Pit P23FSA User Manual
Broil King Charcoal Grill CROWN 20 User Manual
Brother Fax Machine FAX T98 User Manual
Bryan Boilers Boiler AH FS151250D User Manual
Carrier Furnace 58DHL User Manual
Casio Electronic Keyboard HMEC 45 CA User Manual