Installation
FL-1H
FL-1H, FL-1L
Frequency® Lavatory System
U.S. Pat. No. Des. 507,634
Table of Contents
Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Supplies Required . . . . . . . . . . . . . . . . . . . . . . . .2
Cleaning and Maintenance for Terreon® . . . . . . .3
Dimensions - Front and Top Views . . . . . . . . . . . . . 3
Dimensions - Side Views . . . . . . . . . . . . . . . . . . . . . 4
Rough-Ins. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–8
FL-1L
IMPORTANT!
Read this entire installation manual to ensure proper installation.
When finished with the installation, file this manual with the owner or
maintenance department. Compliance and conformity to local codes
and ordinances is the responsibility of the installer.
Installation
Separate parts from packaging and make sure all parts are accounted
for before discarding any packaging material. If any parts are missing,
do not begin installation until you obtain the missing parts.
Packing List
ꢀ
ꢀ
ꢀ
ꢀ
IS
H
T
E
ID
S
P
U
Make sure that all water supply lines have been flushed and then
completely turned off before beginning installation. Debris in supply
lines can cause valves to malfunction.
Turn OFF electrical power to the electrical outlets, then unplug all
electrical units prior to installation. Electrical power MUST remain off
until installation is completed. After installation is complete, turn on
the water supply first, then turn on the electrical power.
Hardware supplied by installer must be appropriate for wall
construction. Wall anchors used must have a minimum pull-out rating
of 1,000 lbs.
Product warranties may be found under “Product Information” on our
215-1511 Rev. D; EN 07-808
© 2007 Bradley Corporation
P.O. Box 309, Menomonee Falls, WI 53052-0309
Phone: 1-800-BRADLEY Fax: 262-253-4161
Page 1 of 8
5/30/07
Installation
FL-1H, FL-1L
Cleaning and Maintenance for Terreon®
Material Description: Terreon® is an NAHB Certified densified solid surface material composed of polyester resin and is
resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit
abrasives.
Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household cleaner such as
Formula 409® or Windex®.
Stubborn Stains: Remove tough stains with Ajax®, Comet®, or Soft-Scrub® and a green Scotch-Brite® pad or lightly sand in
a circular motion with 240 grit wet/dry sandpaper. The finish can be renewed with a maroon Scotch-Brite® pad.
Special Situations for Material
Scratches: Remove scratches with a green Scotch-Brite® pad. The finish can then be renewed with a maroon Scotch-Brite®
pad, followed by a white Scotch-Brite® pad or 30-micron sandpaper.
Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit
thoroughly after cleaning.
Restoring the surface: Use Hope’s® Solid Surface cleaner and polish to refresh and protect the Terreon® Solid Surface
material. Bradley recommends additional care and maintenance for the darker colored Terreon®, for complete instructions on
this additional maintenance refer to Bradley technical document #1505.
Do not use strong acid or alkaline chemicals and cleansers to clean Terreon®. If these chemicals come in
contact with the surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh
chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects.
Repair Kits: Terreon® repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing
Repair kits are made to order and have a shelf life of 30 days.
Terreon® is a unique, cast solid surface material. Aggregate flow and distribution as well as shades of color can vary from
product to product creating natural characteristics.
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement,
nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and
can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that
Dimaellnpsroidounctss s-hFourlodnbet uasneddinTostpricVt aicecwordsance with package instructions.
FL-1H shown
7-3/4"
FL-1L is similar
(197mm)
22"
(559mm)
FL-1H
30"
(762mm)
30"
FL-1L
(762mm)
37-3/4"
37-3/4"
(959mm)
(959mm)
34" ADA
(864mm)
36"
(914mm)
32"
34"
(864mm)
(813mm)
30" ADA
(762mm)
30"
(762mm)
ADA
COMPLIANT
12-1/4"
(311mm)
12-1/4" ADA
(311mm)
Bradley Corporation • 215-1511 Rev. D; EN 07-808
5/30/07
3
FL-1H, FL-1L
Installation
Dimensions - Side Views
22" (559mm)
19-3/4" (502mm)
FL-1H
14"
(356mm)
36"
37-3/4"
(914mm)
Rim Height
Not ADA
Compliant
(959mm)
4-5/8"
(117mm)
30"
(762mm)
12-1/4"
(311mm)
FL-1L
22" (559mm)
22" (559mm)
19-3/4" (502mm)
19-3/4" (502mm)
Juvenile
Standard
Height
14"
14"
Height
(356mm)
(356mm)
Ages 6–12
37-3/4"
(959mm)
34"
(864mm)
Rim
31"
34-3/4"
(787mm)
Rim
Height
(883mm)
Height
4-5/8"
30"
4-5/8"
(117mm)
27"
(762mm)
(117mm)
(686mm)
12-1/4"
9-1/4"
(311mm)
(235mm)
22" (559mm)
19-3/4" (502mm)
22" (559mm)
TAS Height
Grades Pre-K
through 5 or 6
TAS Height
Grades 6 through
8 or 9
19-3/4" (502mm)
14"
14"
(356mm)
(356mm)
33-3/4"
(857mm)
35-3/4"
(908mm)
32"
(813mm)
Rim
30"
(762mm)
Rim
4-5/8"
Height
Height
4-5/8"
(117mm)
28"
(117mm)
(711mm)
26"
(660mm)
TAS
TAS
10-1/4"
8-1/4" (210mm)
(260mm)
4
5/30/07
Bradley Corporation • 215-1511 Rev. D; EN 07-808
Installation
FL-1H, FL-1L
12-7/8"
(327mm)
12-7/8"
(327mm)
1
Rough-Ins
11"
(279mm)
11"
(279mm)
FL-1H
10-1/2"
(267mm)
10"
(254mm)
A
A
A
A
1-3/8"
(35mm)
33"
B
B
(838mm)
D
D
3/4"
30"
(762mm)
(19mm)
W
E
26-3/8"
(670mm)
H
C
Recommended 240v/208v
or 277v electrical rough-in
location (approx. 3 x 6 )
24"
(610mm)
"
"
24"
(610mm)
18-3/4"
(476mm)
5"
5"
(127mm)
4"
(127mm)
(102mm)
17"
(432mm)
12-7/8"
(327mm)
12-7/8"
(327mm)
11"
(279mm)
11"
(279mm)
10-1/2"
(267mm)
10"
(254mm)
FL-1L
A
A
A
A
31"
B
B
(787mm)
D
D
3/4"
(19mm)
28"
(711mm)
1-3/8"
(35mm)
W
E
26-3/8"
(670mm)
H
C
Recommended 240v/208v
or 277v electrical rough-in
location (approx. 3 x 6 )
24"
(610mm)
"
"
18-3/4"
(476mm)
4"
5"
5"
24"
(610mm)
(102mm)
(127mm)
(127mm)
17"
(432mm)
CODE
DESCRIPTION
QTY.
A
B
3/8" Lav Deck Anchors with a Minimum Pull-Out Force of 1,000 lbs.
#10 Wall Anchors/Fasteners for Mounting Trap/Transition Covers
1/2" NPT Hot/Cold Supplies, Stub-Out 2" From Wall
#10 Wall Anchors/Fasteners for Valve Mounting
110v GFI Protected Electrical Outlet
4
2
1
2
1
1
H, C
D
E
W
1-1/2" NPT Drain, Stub-Out 2" from Wall
VERTICAL HEIGHT ADJUSTMENTS FOR CODES
A–E, H, C and W
RIM HEIGHT
FIXTURE STYLE
34"
32"
31"
30"
None
Standard Height
TAS, Grades 6 through 8 or 9
TAS, Pre-K through Grades 5 or 6
Juvenile Height
Subtract 2"
Subtract 3"
Subtract 4"
Bradley Corporation • 215-1511 Rev. D; EN 07-808
5/30/07
5
FL-1H, FL-1L
Installation
2
Lavatory Deck
FL-1L shown
FL-1H is similar
Refer to the rough-ins to determine
wall-mounting location for optional
mixing valve.
Installer may prefer to install the
faucet before mounting the fixture
to the wall. Refer to page 8 for
faucet installation details.
If necessary, adjust the fixture
height before securing to the
support brackets.
Backing Information
Metal Studs
16"
(406mm)
35"
(889mm)
Securely fasten plywood
to at least (3) metal studs
(plywood to equal
Use 3/8" toggle bolts
and washers to secure
the support brackets to
plywood (2) places.
thickness of drywall, 1/2"
minimum
12"
(305mm)
Drywall
25"
(635mm)
6
5/30/07
Bradley Corporation • 215-1511 Rev. D; EN 07-808
Installation
FL-1H, FL-1L
3
Drain and Tailpiece
FL-1H
FL-1L
Rubber
Friction
Rubber
Friction
Tailpiece
Tailpiece
Nut
Nut
4" (102mm)
4
Faucet Battery Box
FL-1L shown
FL-1H is similar
Install the faucet according to
manufacturer’s instructions
B
1/2" Flexible Hose (qty. 3)
(269-1735)
Faucet Valve
Control Module
Mixing Valve
Hot
Mount the Faucet
Battery Box to the wall
at desired location.
A
Cold
Stop/Check Valve
Bradley Corporation • 215-1511 Rev. D; EN 07-808
5/30/07
7
FL-1H, FL-1L
Installation
5
Optional Tankless Water Heater
3/4" (19mm)
FL-1L shown
FL-1H is similar
Model FL-1L shown,
Model FL-1H is similar
Electric Tankless
Water Heater
Outlet
Inlet
Faucet Inlet
20"
(508mm)
Stop/Check Valve,
Cold Supply Outlet
Finished Floor
6
P-Trap and Trap Cover
FL-1L shown
FL-1H is similar
8
5/30/07
Bradley Corporation • 215-1511 Rev. D; EN 07-808
|