Bradley Smoker Plumbing Product FL 1H User Manual

Installation  
FL-1H  
FL-1H, FL-1L  
Frequency® Lavatory System  
U.S. Pat. No. Des. 507,634  
Table of Contents  
Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  
Supplies Required . . . . . . . . . . . . . . . . . . . . . . . .2  
Cleaning and Maintenance for Terreon® . . . . . . .3  
Dimensions - Front and Top Views . . . . . . . . . . . . . 3  
Dimensions - Side Views . . . . . . . . . . . . . . . . . . . . . 4  
Rough-Ins. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–8  
FL-1L  
IMPORTANT!  
Read this entire installation manual to ensure proper installation.  
When finished with the installation, file this manual with the owner or  
maintenance department. Compliance and conformity to local codes  
and ordinances is the responsibility of the installer.  
Installation  
Separate parts from packaging and make sure all parts are accounted  
for before discarding any packaging material. If any parts are missing,  
do not begin installation until you obtain the missing parts.  
Packing List  
IS  
H
T
E
ID  
S
P
U
Make sure that all water supply lines have been flushed and then  
completely turned off before beginning installation. Debris in supply  
lines can cause valves to malfunction.  
Turn OFF electrical power to the electrical outlets, then unplug all  
electrical units prior to installation. Electrical power MUST remain off  
until installation is completed. After installation is complete, turn on  
the water supply first, then turn on the electrical power.  
Hardware supplied by installer must be appropriate for wall  
construction. Wall anchors used must have a minimum pull-out rating  
of 1,000 lbs.  
Product warranties may be found under “Product Information” on our  
215-1511 Rev. D; EN 07-808  
© 2007 Bradley Corporation  
P.O. Box 309, Menomonee Falls, WI 53052-0309  
Phone: 1-800-BRADLEY Fax: 262-253-4161  
Page 1 of 8  
5/30/07  
 
Installation  
FL-1H, FL-1L  
Cleaning and Maintenance for Terreon®  
Material Description: Terreon® is an NAHB Certified densified solid surface material composed of polyester resin and is  
resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit  
abrasives.  
Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household cleaner such as  
Formula 409® or Windex®.  
Stubborn Stains: Remove tough stains with Ajax®, Comet®, or Soft-Scrub® and a green Scotch-Brite® pad or lightly sand in  
a circular motion with 240 grit wet/dry sandpaper. The finish can be renewed with a maroon Scotch-Brite® pad.  
Special Situations for Material  
Scratches: Remove scratches with a green Scotch-Brite® pad. The finish can then be renewed with a maroon Scotch-Brite®  
pad, followed by a white Scotch-Brite® pad or 30-micron sandpaper.  
Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit  
thoroughly after cleaning.  
Restoring the surface: Use Hope’s® Solid Surface cleaner and polish to refresh and protect the Terreon® Solid Surface  
material. Bradley recommends additional care and maintenance for the darker colored Terreon®, for complete instructions on  
this additional maintenance refer to Bradley technical document #1505.  
Do not use strong acid or alkaline chemicals and cleansers to clean Terreon®. If these chemicals come in  
contact with the surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh  
chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects.  
Repair Kits: Terreon® repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing  
Repair kits are made to order and have a shelf life of 30 days.  
Terreon® is a unique, cast solid surface material. Aggregate flow and distribution as well as shades of color can vary from  
product to product creating natural characteristics.  
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement,  
nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and  
can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that  
Dimaellnpsroidounctss s-hFourlodnbet uasneddinTostpricVt aicecwordsance with package instructions.  
FL-1H shown  
7-3/4"  
FL-1L is similar  
(197mm)  
22"  
(559mm)  
FL-1H  
30"  
(762mm)  
30"  
FL-1L  
(762mm)  
37-3/4"  
37-3/4"  
(959mm)  
(959mm)  
34" ADA  
(864mm)  
36"  
(914mm)  
32"  
34"  
(864mm)  
(813mm)  
30" ADA  
(762mm)  
30"  
(762mm)  
ADA  
COMPLIANT  
12-1/4"  
(311mm)  
12-1/4" ADA  
(311mm)  
Bradley Corporation • 215-1511 Rev. D; EN 07-808  
5/30/07  
3
 
FL-1H, FL-1L  
Installation  
Dimensions - Side Views  
22" (559mm)  
19-3/4" (502mm)  
FL-1H  
14"  
(356mm)  
36"  
37-3/4"  
(914mm)  
Rim Height  
Not ADA  
Compliant  
(959mm)  
4-5/8"  
(117mm)  
30"  
(762mm)  
12-1/4"  
(311mm)  
FL-1L  
22" (559mm)  
22" (559mm)  
19-3/4" (502mm)  
19-3/4" (502mm)  
Juvenile  
Standard  
Height  
14"  
14"  
Height  
(356mm)  
(356mm)  
Ages 6–12  
37-3/4"  
(959mm)  
34"  
(864mm)  
Rim  
31"  
34-3/4"  
(787mm)  
Rim  
Height  
(883mm)  
Height  
4-5/8"  
30"  
4-5/8"  
(117mm)  
27"  
(762mm)  
(117mm)  
(686mm)  
12-1/4"  
9-1/4"  
(311mm)  
(235mm)  
22" (559mm)  
19-3/4" (502mm)  
22" (559mm)  
TAS Height  
Grades Pre-K  
through 5 or 6  
TAS Height  
Grades 6 through  
8 or 9  
19-3/4" (502mm)  
14"  
14"  
(356mm)  
(356mm)  
33-3/4"  
(857mm)  
35-3/4"  
(908mm)  
32"  
(813mm)  
Rim  
30"  
(762mm)  
Rim  
4-5/8"  
Height  
Height  
4-5/8"  
(117mm)  
28"  
(117mm)  
(711mm)  
26"  
(660mm)  
TAS  
TAS  
10-1/4"  
8-1/4" (210mm)  
(260mm)  
4
5/30/07  
Bradley Corporation • 215-1511 Rev. D; EN 07-808  
 
Installation  
FL-1H, FL-1L  
12-7/8"  
(327mm)  
12-7/8"  
(327mm)  
1
Rough-Ins  
11"  
(279mm)  
11"  
(279mm)  
FL-1H  
10-1/2"  
(267mm)  
10"  
(254mm)  
A
A
A
A
1-3/8"  
(35mm)  
33"  
B
B
(838mm)  
D
D
3/4"  
30"  
(762mm)  
(19mm)  
W
E
26-3/8"  
(670mm)  
H
C
Recommended 240v/208v  
or 277v electrical rough-in  
location (approx. 3 x 6 )  
24"  
(610mm)  
"
"
24"  
(610mm)  
18-3/4"  
(476mm)  
5"  
5"  
(127mm)  
4"  
(127mm)  
(102mm)  
17"  
(432mm)  
12-7/8"  
(327mm)  
12-7/8"  
(327mm)  
11"  
(279mm)  
11"  
(279mm)  
10-1/2"  
(267mm)  
10"  
(254mm)  
FL-1L  
A
A
A
A
31"  
B
B
(787mm)  
D
D
3/4"  
(19mm)  
28"  
(711mm)  
1-3/8"  
(35mm)  
W
E
26-3/8"  
(670mm)  
H
C
Recommended 240v/208v  
or 277v electrical rough-in  
location (approx. 3 x 6 )  
24"  
(610mm)  
"
"
18-3/4"  
(476mm)  
4"  
5"  
5"  
24"  
(610mm)  
(102mm)  
(127mm)  
(127mm)  
17"  
(432mm)  
CODE  
DESCRIPTION  
QTY.  
A
B
3/8" Lav Deck Anchors with a Minimum Pull-Out Force of 1,000 lbs.  
#10 Wall Anchors/Fasteners for Mounting Trap/Transition Covers  
1/2" NPT Hot/Cold Supplies, Stub-Out 2" From Wall  
#10 Wall Anchors/Fasteners for Valve Mounting  
110v GFI Protected Electrical Outlet  
4
2
1
2
1
1
H, C  
D
E
W
1-1/2" NPT Drain, Stub-Out 2" from Wall  
VERTICAL HEIGHT ADJUSTMENTS FOR CODES  
A–E, H, C and W  
RIM HEIGHT  
FIXTURE STYLE  
34"  
32"  
31"  
30"  
None  
Standard Height  
TAS, Grades 6 through 8 or 9  
TAS, Pre-K through Grades 5 or 6  
Juvenile Height  
Subtract 2"  
Subtract 3"  
Subtract 4"  
Bradley Corporation • 215-1511 Rev. D; EN 07-808  
5/30/07  
5
 
FL-1H, FL-1L  
Installation  
2
Lavatory Deck  
FL-1L shown  
FL-1H is similar  
Refer to the rough-ins to determine  
wall-mounting location for optional  
mixing valve.  
Installer may prefer to install the  
faucet before mounting the fixture  
to the wall. Refer to page 8 for  
faucet installation details.  
If necessary, adjust the fixture  
height before securing to the  
support brackets.  
Backing Information  
Metal Studs  
16"  
(406mm)  
35"  
(889mm)  
Securely fasten plywood  
to at least (3) metal studs  
(plywood to equal  
Use 3/8" toggle bolts  
and washers to secure  
the support brackets to  
plywood (2) places.  
thickness of drywall, 1/2"  
minimum  
12"  
(305mm)  
Drywall  
25"  
(635mm)  
6
5/30/07  
Bradley Corporation • 215-1511 Rev. D; EN 07-808  
 
Installation  
FL-1H, FL-1L  
3
Drain and Tailpiece  
FL-1H  
FL-1L  
Rubber  
Friction  
Rubber  
Friction  
Tailpiece  
Tailpiece  
Nut  
Nut  
4" (102mm)  
4
Faucet Battery Box  
FL-1L shown  
FL-1H is similar  
Install the faucet according to  
manufacturer’s instructions  
B
1/2" Flexible Hose (qty. 3)  
(269-1735)  
Faucet Valve  
Control Module  
Mixing Valve  
Hot  
Mount the Faucet  
Battery Box to the wall  
at desired location.  
A
Cold  
Stop/Check Valve  
Bradley Corporation • 215-1511 Rev. D; EN 07-808  
5/30/07  
7
 
FL-1H, FL-1L  
Installation  
5
Optional Tankless Water Heater  
3/4" (19mm)  
FL-1L shown  
FL-1H is similar  
Model FL-1L shown,  
Model FL-1H is similar  
Electric Tankless  
Water Heater  
Outlet  
Inlet  
Faucet Inlet  
20"  
(508mm)  
Stop/Check Valve,  
Cold Supply Outlet  
Finished Floor  
6
P-Trap and Trap Cover  
FL-1L shown  
FL-1H is similar  
8
5/30/07  
Bradley Corporation • 215-1511 Rev. D; EN 07-808  
 

Black Box Computer Hardware RS 449 User Manual
BRK electronic Carbon Monoxide Alarm SCO7B User Manual
Brother Sewing Machine Brother CP 6500 User Manual
Cadet Electric Heater C051 User Manual
Canon All in One Printer 2020 User Manual
Canon Projector LV 7320U User Manual
Casio Camcorder EX Z4 User Manual
Casio Electronic Keyboard AP 220 User Manual
Cecilware Beverage Dispenser 12 20 UL User Manual
Christie Digital Systems Projector 25K User Manual