Where Applicable
Commercial Energy Saver Gas
Millivolt Models
Standard Equipment Features:
Bradford White is ISO registered
to the 9001-standard.
9001
S
T
A
N
D
A
R
D
I Non-CFC foam insulation.
I Vitraglas® lined tank.
I Factory installed Hydrojet® Sediment
Reduction System.
I Factory installed dielectric fittings.
I Flue damper.
I Continuous pilot-ignition.
I Magnesium anode rods.
I Hand hole cleanout.
I Millivolt controls.
I Brass drain valve.
I T&P relief valve installed.
I Millivolt models are available from 125,000
to 270,000 BTUH (36.6 KW to 79.1 KW)
I Three year limited warranty.
I One year limited parts warranty.
I Design certified by CSA International
(formerly AGA and CGA)
I All models listed with California Energy
Commission.
Optional Features:
I NSF construction available.
I ASME code available on all models
above 200,000 BTUH (58.6KW)
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS:
7,063,133 B2; 5,954,492; 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117;
6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770;
5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448;
4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184;
4,861,968; 4,672,919; Re. 34,534. OTHER U.S. AND FOREIGN PATENT
APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043;
1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105.5.
Dimensions
Millivolt Models
B
H
B
H
T & P
T & P
HOT
HOT
G
G
C
A
A
D
D
CLEANOUT
E
COLD
E
F
F
Water Connections
Water Connections
Front and Rear
DM75T160
Top and Front
DM75T125
Top Front, Rear
DM100L199, 250, 270
DM100S199, 250
DM80T180, 199, 250
DM100T199, 250
DM38T155
Sample Specification
The water heater shall be a Bradford White model with a storage capacity of not less than ____________ gallons (____________ liters), a minimum
gas input of ____________ BTUH (KWH), and a minimum recovery of _______ GPH (LPH) at 100°F (56°C). temperature rise. It shall be design
certified by CSA International (formerly AGA and CGA) for 180°F (82°C). application, either with or without a separate storage tank. The tank shall
be lined with Vitraglas® vitreous enamel and shall have a bolted hand hole cleanout. The tank shall have ____________ extruded magnesium anode
rods installed in separate head couplings and extended to within three inches of the bottom. The heater shall be insulated with non-CFC foam
insulation. This water heater shall be equipped with an ASME rated T&P relief valve, a continuous pilot ignition system and flue damper. The entire
installation shall be made in compliance with state and local codes and ordinances.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
MILLIVOLT MODELS Includes installed T&P Valve and Flue Damper with Continuous Pilot Ignition.
DIMENSIONS IN INCHES
WEIGHT
RECOVERY GPH
AT DEGREE RISE
NAT
& LP
INPUT
BTU
1ST HR.
DEL. GAL.
AT 100°F
RISE
STG.
CAP.
U.S.
C
D†
F&R
HW
E†
F&R
CW
G
TOP
WTR.
F
TOP
VENT
HT.
H
VENT
DIA.
WTR.
CONN.
DIA.
GAS RELIEF
CONN. VALVE
DIA. OPEN.
A
HT.
B
DIA.
GAS
MODEL NUMBER
40°
100°
147
121
151
175
194
242
194
242
194
242
262
194
242
140°
GAL.
CONN. CONN. CONN. CONN.
STD. ASME
L
L
1
3
3
5
1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
DM-38T-155-3N
155,000
125,000
160,000
180,000
199,999
250,000
199,999
250,000
199,999
250,000
270,000
199,999
250,000
174
174
204
231
250
298
263
311
264
312
332
264
312
368
303
378
436
485
606
485
606
485
606
655
485
606
105
86
38
75
75
80
80
80
98
98
100
100
100
100
100
43
65
65
28 ⁄
4
4
—
34 ⁄
2
4
19 ⁄
8
4 ⁄
4
8
51
72 ⁄4
6
5
6
6
6
6
6
6
6
6
6
6
6
1
⁄
2
2
⁄
⁄4
⁄4
⁄4
⁄4
⁄4
⁄4
⁄4
⁄4
⁄4
⁄4
⁄4
4
⁄
⁄4
⁄4
⁄4
4
438
520
520
540
540
540
610
—
—
—
—
—
1
1
1
3
1
1
DM-75T-125-3N
28 ⁄
67 ⁄
8
54 ⁄
34
4 ⁄
1 ⁄
DM-75T-160-3N(LP)
DM-80T-180-3N
108
124
139
173
139
173
139
173
187
139
173
28 ⁄
4
67 ⁄
8
54 ⁄
56
56
56
67
2
34
4 ⁄
4
72 ⁄
4
1
⁄
1
2
1
1
1
3
1
1
1
1
1
1
3
3
64 ⁄
2
2
28 ⁄
4
66 ⁄
4
4
19 ⁄
2
4 ⁄
4
72 ⁄
8
1 ⁄
2
L
L
L
L
L
L
L
L
L
L
DM-80T-199-3N(LP)
DM-80T-250-3N(A)(LP)
DM-100T-199-3N
DM-100T-250-3N(A)(LP)
DM-100L-199-3N
DM-100L-250-3N(A)
DM-100L-270-3N(A)*
DM-100S-199-3N
DM-100S-250-3N(A)
64 ⁄
28 ⁄
4
66 ⁄
19 ⁄
2
4 ⁄
4
72 ⁄
8
1 ⁄
1
2
⁄4
1
1
1
1
3
3
1
1
1
1
1
3
3
64 ⁄
2
28 ⁄
4
66 ⁄
4
19 ⁄
2
4 ⁄
4
72 ⁄
8
1
1 ⁄
⁄
2
1
590
—
1
1
1
1
3
3
1
3
75 ⁄
2
28 ⁄
4
77 ⁄
4
19 ⁄
2
4 ⁄
4
83 ⁄
8
2
⁄4
1
1
1
1
3
3
1
75 ⁄
2
28 ⁄
4
77 ⁄
67
67
67
75
75
4
67
19 ⁄
2
4 ⁄
4
83 ⁄
8
1 ⁄
2
1
610 690
725
1
1 ⁄
2
(T&F)
1
1
1
1
3
65
65
30 ⁄
4
56 ⁄
2
23 ⁄
2
4 ⁄
2
75
75
⁄4
—
2(R)
1
1 ⁄
2
(T&F)
1
1
1
1
30 ⁄
4
56 ⁄
2
23 ⁄
2
4 ⁄
2
1
725 765
725 765
2(R)
1
1 ⁄
2
(T&F)
1
1
1
1
65
30 ⁄
4
56 ⁄
2
23 ⁄
2
4 ⁄
2
75
1
2(R)
1
1 ⁄
2
(T&F)
7
1
1
3
1
3
3
72 ⁄
8
28 ⁄
4
60 ⁄
2
20 ⁄
4
4 ⁄
2
76 ⁄
4
⁄4
667
—
2(R)
1
1 ⁄
2
(T&F)
7
1
1
3
1
3
72 ⁄
8
28 ⁄
4
60 ⁄
2
20 ⁄
4
4 ⁄
2
76 ⁄
4
⁄4
1
667 702
2(R)
DIMENSIONS IN MILLIMETERS
WEIGHT
RECOVERY LPH
AT DEGREE RISE
1ST HR.
DEL. LTR.
AT 56°C
RISE
C
D†
F&R
HW
E†
G
TOP
WTR.
F&R
CW
F
TOP
VENT
HT.
H
VENT
DIA.
WTR.
CONN.
DIA.
GAS RELIEF
CONN. VALVE
STD
WT.
(KG)
ASME
WT.
(KG)
KW
STG.
LITERS
A
HT.
B
DIA.
GAS
CONN.
MODEL NUMBER
INPUT
22°
56°
78°
CONN. CONN. CONN.
DIA.
19
19
19
19
19
19
19
19
19
19
19
19
19
OPEN.
L
L
DM-38T-155-3N
45.4
36.6
46.8
52.7
58.6
73.2
58.6
73.2
58.6
73.2
79.0
58.6
73.2
659
659
772
874
946
1128
995
1177
999
1181
1257
999
1391
1147
1431
1650
1836
2294
1836
2294
1836
2294
2479
1836
2294
556
458
572
662
734
916
734
916
734
916
992
734
916
397
326
409
469
526
655
526
655
526
655
708
526
655
144
284
284
303
303
303
1092
1651
1651
1638
1638
1638
718
718
718
718
718
718
—
883
492
864
864
495
495
495
117
121
121
121
121
121
1295
1835
1835
1838
1838
1838
152
127
152
152
152
152
38
38
38
38
38
38
38
38
19
19
19
19
19
25
19
25
19
25
25
19
25
199
236
236
245
245
245
277
277 313
329
329 347
329 347
—
—
—
—
—
DM-75T-125-3N
1705 1384
1705 1384
1683 1422
1683 1422
1683 1422
DM-75T-160-3N(LP)
DM-80T-180-3N
L
L
L
L
L
L
L
L
L
L
DM-80T-199-3N(LP)
DM-80T-250-3N(A)(LP)
DM-100T-199-3N
DM-100T-250-3N(A)(LP)
DM-100L-199-3N
DM-100L-250-3N(A)
DM-100L-270-3N(A)*
DM-100S-199-3N
DM-100S-250-3N(A)
268
—
371 1918 718 1962 1702 495
371 1918 718 1962 1702 495
121 2118 152
121 2118 152
114 1905 152
114 1905 152
114 1905 152
114 1949 152
114 1949 152
38 (T&F)
51(R)
379
379
379
379
379
1651 768
1651 768
1651 768
1851 718
1851 718
1702 1435
1702 1435
1702 1435
1905 1537
1905 1537
597
597
597
527
527
—
38 (T&F)
51(R)
38 (T&F)
51(R)
38 (T&F)
302
302 318
—
51(R)
38 (T&F)
51(R)
1181
For LP models change suffix “N” to “X”
- 80% Thermal Efficient
(A) - ASME
T - Top Water Connection
F - Front Water Connection
R - Rear Water Connection
* - Available with natural gas only.
Energy Saver Series feature Hand Hole Cleanout on all models.
L
Recoveries and First Hour Delivery Rating are based on Thermal Efficiencies ranging
up to 80%.
150 PSI Working Pressure, 300 PSI Test Pressure.
† Rear connections offered as standard on the "L" and "S" models. DM38T155 also
features rear connections.
For LowNOx compliance to meet SCAQMD requirements, place
an “E” following the BTU Input identifier of the model number.
Example: DM-75T-125E-3N
Ambler, PA
Efficiency in compliance with CSA International (formerly AGA/CGA)
For U.S. and Canada field service,
contact your professional installer or
local Bradford White sales representative.
ANSI Z21.10.3 requirements. These models meet or exceed the Thermal
efficiency and standby loss requirements of ASHRAE 90.1b (current
edition).
Sales/800-523-2931
Fax/215-641-1670
(LP) Propane Gas Inputs
1ST HR. DEL.
GAL. @ 100°F RISE/
LITER @ 56°C RISE
RECOVERY @ DEGREE RISE
GPH/LPH
40°F/22°C 100°/56°C 140°/78°C
Technical Support/800-334-3393
Fax/269-795-1089
75T-160
80T-199
80T-250
100T-250
155,000BTU/H/45.4KW
190,000BTU/H/55.7KW
235,000BTU/H/68.9KW
235,000BTU/H/68.9KW
199/753
240/908
284/1075
297/1124
366/1385 147/556 105/397
461/1745 184/696 132/500
570/2157 228/863 163/616
570/2157 228/863 163/616
Warranty/800-531-2111
Fax/269-795-1089
International:
Telephone/215-641-9400
Telefax/215-641-9750
All models are design certified by CSA International (formerly AGA and
CGA) for up to 180°F (82°C) application as an Automatic Storage Heater,
and an Automatic Circulating Tank Heater.
Fax on Demand:
888-538-7833
As an Automatic Storage Heater, all models are complete self-contained
water heating systems. It needs no separate storage tank, pump, wiring
or elaborate piping network. When equipped with a mixing valve, it will
supply 180°F (82°C) sanitizing and 140°F (60°C). general purpose hot
water simultaneously. These models can be used either as a single unit or
in multiples connected in parallel.
Mississauga, ON
Sales/Technical Support
866-690-0961
905-238-0100
Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
©2006 Bradford White Corporation. All rights reserved.
Fax/905-238-0105