SC & SI Remote Interface Description  
en SC & SI Remote  
Interface Description  
 
SC & SI Remote Interface Description  
en | 3  
1
Introduction  
1.1  
Purpose  
The purpose of this document is to describe the remote interface for system configuration and system  
installation. The document specifies the interface between the CCU and third party software.  
1.2  
Scope  
This document describes the remote interface for system configuration and system installation. It is meant for  
developers who want to use this remote interface to control/access system configuration and system  
installation, present in the CCU, remotely.  
For a complete description of the System Set-up can be referred to [SRS_INF].  
1.3  
Definitions, Acronyms and Abbreviations  
CCU  
Central Control Unit. This can be either a Single-CCU system or a  
Multi-CCU system.  
DCN  
SC  
Digital Congress Network  
System Configuration  
SI  
System Installation  
DQS  
OMF File  
Database Query Services  
An executable file in a special format that can be programmed or  
downloaded into the ReadOnlyMemory on the CCU  
Trunc Communication Board  
TCB  
MTB  
UnitId  
Multi Trunc Board  
Unit identification, also called unit-number. A unique identification of  
a unit within the CCU system.  
remote controller  
Device (e.g. PC) connected to the CCU which remotely controls a  
part of the applications present in the CCU.  
1.4  
References  
[SRS_INF]  
General Remote Interface Description  
[USERDOC_DB] User Manual LBB 3580  
[USERDOC_SI] User Manual LBB 3585  
This document must be referenced as [SRS_SCSIINF].  
1.5  
Overview  
Chapter 2 gives a brief explanation on System Configuration and System Installation. Also a short description  
of the different CCU system modes is given in this chapter. For system configuration, the remote functions  
and update notifications are described in chapters 3 and 4. For system installation, the remote functions and  
update notifications are described in chapters 5 and 6.  
Appendix Appendix A gives an overview of the constants used in combination with the remote functions and  
update notifications described in this document.  
Appendix Appendix B gives an overview of the possible error’s that could be returned upon execution of a  
remote function.  
Appendix Appendix C shows some examples on typical System Configuration or System Installation topics.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 4  
2
System configuration and system installation  
2.1  
Introduction  
The System Configuration and System Installation Remote Interface is part of the DCN software which allows  
another controlling entity, not being the DCN Control PC, to use the System Configuration and System  
Installation applications.  
2.2  
Remote System Configuration and System Installation  
System Configuration (SC) is the application that monitors the hardware configuration of the congress system  
and the link between hardware items and user information. Typical SC issues are, e.g. checking the  
communication status, determining the system mode and replacing units.  
System Installation (SI) is the application that allows for assigning seatnumbers to units to create a one to one  
link between a unique user chosen identifier and a congress unit in the conference hall.  
Maintaining the system configuration or performing a system installation with a remote interface is done by  
means of calling a defined set of Remote Functions and acting upon a defined set of Update Notifications.  
The general concept of remote functions and update notifications is described in [SRS_INF]. [SRS_INF] also  
defines the protocol and hardware conditions concerning the remote interface. This document gives the set of  
remote functions and the set of update notifications concerning SC and SI. The relation between remote  
function and update notifications is given in the description of each separate remote function.  
The system configuration and system installation process however, are also influenced by the actions of the  
users performed upon the actual units. Actions such as pressing the microphone button or disconnecting a  
unit from the system also results in update notifications being sent to the remote controller. The relation  
between unit/user events and update notifications can be found in the user event matrices in sections 4.1.2  
en 6.1.1.  
2.3  
System Modes  
To understand the SC and SI functions, one should have some knowledge on the behaviour of the CCU  
depending on the various so called system modes. This section gives a brief, although complete, description  
of these modes.  
The CCU system as a whole is always running in one of the system modes. Each application on the CCU has  
its own behaviour in each system mode. The purpose of the system mode is to have a clear division of  
functions and an easy way of separating them. It should be impossible for instance to start the installation  
mode while the CCU is still booting, i.e. the CCU is in the Init-mode.  
The following system modes are used:  
init  
One time mode after start-up of the CCU. The CCU can  
start with default data (defined as ‘cold start’), or with data  
the last time used (so called ‘warm start’).  
config  
congress  
In this system mode the DCN configuration can be  
changed, for instance installing units, assigning  
seatnumbers, assigning audio channels etc.  
This is the 'normal' system mode. In this mode most  
applications will do their work, for instance starting a  
voting round, turning on a microphone, interpreting etc.  
maintenance In this system mode the DCN system can be maintained,  
for instance testing microphones, testing audio channels,  
factory testing and equalisation.  
download  
In this system mode new CCU software can be  
downloaded.  
down  
One time system mode just before shutdown of the CCU.  
Figure 1 below gives an overview of possible system mode changes.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 5  
Init  
Config  
Congress  
Download  
Maintenance  
Down  
Figure 1: CCU System modes  
Some remote functions are supported in more than one system mode, or in an other mode than the congress  
system mode.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 6  
3
System Configuration Functions  
3.1  
Introduction  
The system configuration functions described in this section are needed to query the set-up of the DCN-  
system from the CCU. The system configuration functions allow the remote controller to monitor any changes  
in the DCN system configuration. This chapter defines the set of remote functions for system configuration.  
3.1.1 Remote function item explanation  
Each description consists of the following items:  
Purpose  
A global description of the purpose of the function.  
Availability  
CCU System modes in which the function is available. See section 2.3.  
Parameter structure for the function  
The input parameters needed to fulfil the function. When the function requires no parameters, no  
structure is described here.  
Response structure from the function  
The output information returned by the function called. This information is only valid when the  
‘wError’ field of the received response information equals SC_E_NOERROR, SI_E_NOERROR or  
DQSE_NOERROR.  
Error codes returned  
The error values returned in the ‘wError’ field of the response information. All different error codes  
are described in appendix Appendix B.  
Update notifications  
The update notifications which are generated during the execution of the remote function. When  
there are no notifications generated, then this part will be omitted.  
Related functions  
The related function in conjunction with the function described. It refers to other remote functions  
and to related update notifications.  
3.2  
SC_C_CHECK_LINK  
Purpose  
Function, which does no execution on the CCU. This function is to check the communication link between the  
CCU and the remote controller. When executed, the function returns immediately. Therefor quickly returning  
SC_E_NOERROR to the remote controller when there is a connection.  
Availability  
This function is available in CCU system mode's init, maintenance, config and congress.  
Parameter structure for the function  
The function has no additional parameters.  
Response structure from the function  
The function has no response parameters.  
Error codes  
SC_E_NOERROR  
3.3  
SC_C_START_DCN  
Purpose  
Indicates the CCU that the remote controller wants update notifications from the SC application inside the  
CCU. After receiving this function the CCU increments the update ‘use’ count. As long as the update use  
count is greater than zero, the CCU will send update notifications to the remote controller.  
The returned update use count can be used to detect if the remote controller is connected too often.  
When you omit the execution of this remote function, you can still execute remote functions, but no update  
messages will be send to the remote controller.  
Availability  
This function is available in CCU system modes config and congress.  
Parameter structure for the function  
The function has no additional parameters.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 7  
Response structure from the function  
The function returns the following structure:  
WORD  
wNrOfInstances  
where:  
wNrOfInstances  
The value of the update use count for the SC application at the  
end of the function handling. It contains the number of times a  
remote PC has been connected over the same communication  
medium. E.g. the first time the function SC_C_START_DCN is  
called, it contains the value 1.  
Error codes returned  
SC_E_NOERROR  
Related functions  
SC_C_STOP_DCN  
3.4  
SC_C_STOP_DCN  
Purpose  
Indicates the CCU that the remote controller no longer requires updates from the SC application inside the  
CCU. After receiving this function the CCU decrements the update ‘use’ count. As long as the update use  
count is greater than zero, the CCU remains sending the update notifications to the remote controller.  
Note that:  
Upon communication lost this function will be activated, if SC_C_START_DCN was  
activated. The activation of this function is repeated till the update use count  
becomes zero.  
Availability  
This function is available in CCU system modes config and congress.  
Parameter structure for the function  
The function has no additional parameters.  
Response structure from the function  
The function has the same response structure as the remote function SC_C_START_DCN (section 3.3).  
Error codes returned  
SC_E_NOERROR  
Related functions  
SC_C_START_DCN  
3.5  
SC_C_GET_CCU_VERSIONINFO  
Purpose  
This function is used to query the CCU version information. Usually this will be the first function called after  
start-up of the remote controller to check the correct version of the CCU software.  
Availability  
This function is available in CCU all system modes.  
Parameter structure for the function  
The function has no additional parameters.  
Response structure from the function  
The function returns the following structure:  
typedef struct  
{
WORDtOperatingMode;  
CHARszSwVersion [SC_C_MAX_VERSION_LENGTH];  
BYTEbyMajorVersionOfDownloadedSw;  
BYTEbyMinorVersionOfDownloadedSw;  
BYTEbyMajorVersionOfResidentSw;  
BYTEbyMinorVersionOfResidentSw;  
BYTEbySystemMode;  
BYTEbyReservedForSwInfo [SC_C_MAX_SOFTWARE_INFO];  
SC_T_CCU_TYPE  
tCCUType;  
BYTEbyMTBVersion;  
BYTEbyTCBVersion;  
BYTEbyReservedForHwInfo [SC_C_MAX_HARDWARE_INFO];  
CHARszSWRelNum[VERSION_C_LENGTH];  
} SC_T_CCU_VERSION_INFO;  
where:  
tOperatingMode  
The current operating mode of the CCU. It gives information  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 8  
about the environment the CCU is functioning. The value is an  
‘OR’ mask of the following settings:  
SC_C_STANDALONE  
SC_C_EXTENDED  
SC_C_SINGLETRUNC  
SC_C_MULTITRUNC  
SC_C_MASTER  
SC_C_SLAVE  
szSwVersion  
The current operating mode of the CCU in readable text. The  
string is zero (‘\0’) terminated. If e.g. it is a Single CCU running  
extended software, this string would read:  
“EXTENDED SingleTrunc Version”.  
byMajorVersionOfDownloadedSw, byMinorVersionOfDownloadedSw  
The major and minor version numbers of the downloaded  
software (OMF-file). If no downloaded software is present, then  
both will be zero.  
If e.g. the downloaded software is DCN 7.0,  
byMajorVersionOfDownloadedSw will be ‘7’ and  
byMinorVersionOfDownloadedSw will be ‘0’  
byMajorVersionOfResidentSw, byMinorVersionOfResidentSw  
The major and minor version numbers of the resident software  
(Boot-software).  
If e.g. the resident software is of version 2.1,  
byMajorVersionOfResidentSw will be ‘2’ and  
byMinorVersionOfResidentSw will be ‘1’.  
bySystemMode  
The Current System Mode of the CCU. Value according to  
following type:  
DCNC_SM_DOWN  
DCNC_SM_INIT  
DCNC_SM_CONFIG  
DCNC_SM_CONGRESS  
DCNC_SM_MAINTENANCE  
DCNC_SM_DOWNLOAD  
byReservedForSwInfo Reserved space for extra software information.  
tCCUType  
Type of CCU connected to. Value according to following type:  
SC_C_LBB3500_00  
SC_C_LBB3500_10  
SC_C_LBB3500_30  
SC_C_LBB3511_00  
byMTBVersion  
byTCBVersion  
Hardware version of the Multi-Trunk Board inside the CCU.  
(zero if not present.)  
Hardware version of the Trunk Communication Board inside the  
CCU.  
byReservedForHwInfo Reserved space for extra hardware information.  
szSWRelNum  
Software version number as ASCII string. The string is zero  
(‘\0’) terminated. Normally this is the string representation of  
byMajorVersionOfDownloadedSw plus  
byMinorVersionOfDownloadedSw, e.g. if the version of the  
downloaded software is 7.00, this string will read “7.00”  
Error codes returned  
SC_E_NOERROR  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 9  
3.6  
SC_C_GET_CCU_CONFIG  
Purpose  
Retrieve information about all units connected to the congress network. This function returns for each unit  
connected its unit-number and type.  
Availability  
This function is available in CCU system mode congress.  
Parameter structure for the function  
The function requires the following structure as parameter:  
WORD  
wClusterIndex;  
where:  
wClusterIndex  
Determines which cluster is to be returned as response. Zero  
(0) to retrieve the first cluster of SC_C_CLUSTER_MAX units.  
One (1) for the second cluster of SC_C_CLUSTER_MAX units,  
etc.  
When the cluster is not completely filled, then that cluster is the  
last cluster available.  
All cluster indexes greater than this one will have an empty  
tUnitData array. However, the other three elements of the  
response structure will still contain correct data.  
Response structure from the function  
The function returns the following structure:  
typedef struct  
{
WORDwNumberOfSlaveCCUs;  
WORDwNumberOfUnitsConnected;  
WORDwNumberOfUnits;  
SC_T_UNIT_DATA tUnitData [SC_C_CLUSTER_MAX];  
} SC_T_CCU_CONFIGURATION;  
where the SC_T_UNIT_DATA is defined as:  
typedef struct  
{
WORDwUnitId;  
BYTEbyUnitType;  
} SC_T_UNIT_DATA;  
where:  
wNumberOfSlaveCCUs  
The number of Slave-CCU’s connected within a Multi-CCU  
system, which ranges from 0 to 16. In case of a Single-CCU  
system this number will be zero.  
WNumberOfUnitsConnected  
The actual number of units present in the system, even if the  
total number is larger than the maximum size of the ‘tUnitData’  
array. wNumberOfUnitsConnected ranges from 0 to  
DBSC_MAX_ACT_UNIT.  
When there are more units than the size of the ‘tUnitData’  
structure, the structure is completely filled and the unit data for  
the other units must be queried by using another clusterindex.  
This number will be the same for all clusters requested.  
wNumberOfUnits  
tUnitData []  
wUnitId  
The number of units present in the tUnitData array. Only this  
amount of array elements is transmitted. This number will be  
limited to the upper bound of the tUnitData array-size.  
Array holding the unit-information of each unit. Each array  
element is defined as a SC_T_UNIT_DATA structure. The  
elements of this structure are described below.  
The unit identifier of a unit. Also called unit-number.  
byUnitType  
The type of the unit, which is on of the following:  
DCNC_UNIT_DELEGATE  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 10  
DCNC_UNIT_CHAIRMAN  
DCNC_UNIT_DELEGATE_CARD  
DCNC_UNIT_INTERPRETER  
DCNC_UNIT_DUAL_MIC  
DCNC_UNIT_PC  
DCNC_UNIT_DATA_COMM  
DCNC_UNIT_CCU_CONTROL  
DCNC_UNIT_FLUSH_CHAIRMAN  
DCNC_UNIT_FLUSH_DELEGATE  
DCNC_UNIT_AMBIENT_MIC  
DCNC_UNIT_DATA_COMM_RS232  
DCNC_UNIT_2000_DELEGATE  
DCNC_UNIT_2000_CHAIRMAN  
DCNC_UNIT_2000_DELEGATE_CARD  
DCNC_UNIT_AUDIO_IO  
DCNC_UNIT_DAI_CHAIRMAN  
DCNC_UNIT_DISC_DELEGATE  
DCNC_UNIT_DISC_CHAIRMAN  
DCNC_UNIT_ENTRANCE  
DCNC_UNIT_EXIT  
DCNC_UNIT_FLUSH_DEL_NODISP  
DCNC_UNIT_FLUSH_CHR_NODISP  
Note that future unit extensions of the DCN system can  
lead to new unit-type, not presented in this list.  
Error codes returned  
SC_E_NOERROR  
3.7  
SC_C_START_DQS  
Purpose  
Indicate the CCU that the remote controller wants to communicate with the delegate database in the CCU.  
When the execution of this remote function is omitted, all other remote database functions have no effect and  
will return the error DQSE_APP_NOT_STARTED.  
Availability  
This function is available in CCU system mode congress.  
Parameter structure for the function  
The function requires the following structure as parameters.  
typedef struct  
{
BYTEbyControlType;  
} DQST_APP_CONTROL;  
where:  
byControlType  
Identify that the remote controller likes to perform actions on the  
database of the CCU. Valid values are:  
The remote controller likes to have  
control over the database of the CCU.  
SC_C_DQS_CONTROL  
Note that the second start of the application (without a stop) always results in an error.  
Response strcuture from the function  
The function has no response parameters.  
Error codes returned  
DQSE_NOERROR  
DQSE_INCONTROL_OTHER_CHANNEL  
DQSE_INCONTROL_THIS_CHANNEL  
DQSE_ILLEGAL_CONTROL_TYPE  
Related functions  
SC_C_STOP_DQS  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 11  
3.8  
SC_C_STOP_DQS  
Purpose  
Indicate the CCU that the remote controller no longer requires to access the database inside the CCU. A call  
to this function does not clear the database. The database present remains active till the CCU is restarted or  
accessed by the database functions (after first calling SC_C_START_DQS).  
Note that:  
activated.  
Upon communication loss this function will be activated, if SC_C_START_DQS was  
Availability  
This function is available in CCU system mode congress.  
Parameter structure for the function  
The function has no additional parameters.  
Response strcuture from the function  
The function has no response parameters.  
Error codes returned  
DQSE_NOERROR  
DQSE_APP_NOT_STARTED  
related functions  
SC_C_START_DQS  
3.9  
SC_C_MAINT_CCU_DB  
Purpose  
The delegate database in the CCU can be filled or changed using this remote function. To manage the  
delegate database, SC uses the DQS sublink on the CCU.  
Availability  
This function is available in CCU system mode congress. However, if another application is making use of the  
delegate database inside the CCU, e,g, Voting or Access Control, this function will return the errorcode  
DQSE_DELEGATE_DATA_BLOCKED  
Parameter structure for the function  
typedef struct  
{
BOOLEAN bFirstCluster;  
BOOLEAN bLastCluster;  
SWORD  
SWORD  
iPinSize;  
iFillLevel;  
DQST_PERDELEGATE DelCluster[ DQSC_MAX_N_DL_DEL_REC];  
} DQST_CCUMAINREC ;  
with DQST_PERDELEGATE defined as :  
typedef struct  
{
DWORD  
DWORD  
DWORD  
lDelId;  
lCard;  
lPin;  
WORDwUnitNr;  
SWORD  
DWORD  
iDeskLang;  
lVWeight;  
BOOLEAN bMicAut;  
BOOLEAN bVotingAut;  
BOOLEAN bInterAut;  
CHARszSLine [DBSC_NCHAR_SCREENLINE];  
} DQST_PERDELEGATE;  
where:  
bFirstCluster  
bLastCluster  
iPinSize  
Indicates if this block is the first cluster.  
Indicates if this block is the last cluster.  
Indicated current pincode size. Possible values are 3,  
4 and 5  
iFillLevel  
DelCluster;  
lDelId  
The DelCluster array is filled with iFillLevel entries.  
The following items per array entry are available :  
Delegate identification number. A unique number in  
the range 1..DBSC_MAX_DELEGATE. It is  
recommended to use DelegateId’s in an increasing  
order, starting from 1.  
lCard  
Delegate card code. A unique number in the range  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 12  
1..MAX_CARD_CODE. This is the numeric code  
present on the identification card handed over to the  
delegate and which is to be used in combination with  
attendance registration and access control.  
lPin  
Delegate pincode. A numeric value in the range  
111..555551. PIN codes are used for attendance  
registration and access control, but do not have to be  
unique.  
wUnitNr  
The unit number that the delegate is assigned to by  
default. This unit number must equal UnitId retrieved  
with SC_C_GET_CCU_CONFIG  
iDeskLang  
Delegate display language. One of:  
DCNC_VER_ENGLISH  
DCNC_VER_FRENCH  
DCNC_VER_GERMAN  
DCNC_VER_ITALIAN  
DCNC_VER_SPANISH  
DCNC_VER_SIXTH  
lVWeight  
Delegate vote weight. A value in the range  
1..MAX_VOTE_WEIGTH to be used by the voting  
application.  
bMicAut  
TRUE: this delegate has microphone authorisation.  
FALSE: this delegate has no micro. authorisation  
TRUE: this delegate has voting authorisation.  
FALSE: this delegate has no voting authorisation  
TRUE: this delegate has intercom authorisation.  
FALSE: this delegate has no intercom authorisation.  
Delegate screenline. A string to represent a delegate  
e.g. on a Hall Display.  
bVotingAut  
bInterAut  
szSLine  
If more than DQSC_MAX_N_DL_DEL_REC records should be send to the CCU, more calls of this remote  
function will be needed. In this case the ‘bFirstCluster’ and ‘bLastCluster’ indicate the start and termination of  
the complete delegate database download.  
Response structure from the function  
The function has no response parameters.  
Error codes returned  
DQSE_NOERROR  
DQSE_SET_PINSIZE_FAILED  
(when pincode size update fails)  
DQSE_DELEGATE_LIST_TOO_BIG  
(when iFillLevel is greater than  
DQSC_MAX_N_DL_DEL_REC)  
DQSE_INSERT_DELEGATE_FAILED (when delegate insert failed)  
DQSE_DELEGATE_DATA_BLOCKED  
DQSE_APP_NOT_STARTED  
Related functions  
SC_C_START_DQS  
SC_C_DOWNLOAD_CCU_DB  
SC_C_CLEAR_CCU_DB  
SC_C_CCU_APPLY_ONE  
3.10 SC_C_DOWNLOAD_CCU_DB  
Purpose  
This function is equal to SC_C_MAINT_CCU_DB except that it does not contain a field for the delegates  
screenline in the parameter structure.  
1 Although the PIN code is identified as a variable of the type ‘long’, the real PIN code is a 6-based number. This means  
that only digits 1 - 5 are allowed to be part of the PIN code. Besides, the PIN code also depends on the iPinSize variable.  
If e.g. iPinSize is 3, the possible values for lPin range from 111 to 555. If iPinSize is 5 then lPin ranges from 11111 to  
55555. So, lPin must always contain iPinSize digits in the range 1..5.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 13  
Availability  
This function is available in CCU system mode congress.  
Parameter structure for the function  
typedef struct  
{
BOOLEAN bFirstCluster;  
BOOLEAN bLastCluster;  
SWORD  
SWORD  
DQST_DEL_NO_SLINE  
iPinSize;  
iFillLevel;  
DelCluster [DQSC_MAX_N_DL_DEL_REC];  
} DQST_CCUDOWNLOADREC ;  
with DQST_DEL_NO_SLINE defined as :  
typedef struct  
{
DWORD  
DWORD  
DWORD  
lDelId;  
lCard;  
lPin;  
WORDwUnitNr;  
SWORD  
DWORD  
iDeskLang;  
lVWeight;  
BOOLEAN bMicAut;  
BOOLEAN bVotingAut;  
BOOLEAN bInterAut;  
} DQST_DEL_NO_SLINE;  
All fields in the structures used within this function have the same meaning and range as the corresponding  
fields of the structures used within SC_C_MAINT_CCU_DB.  
Response structure from the function  
The function has no response parameters.  
Error codes returned  
DQSE_NOERROR  
DQSE_SET_PINSIZE_FAILED  
(when pincode size update fails)  
DQSE_DELEGATE_LIST_TOO_BIG  
(when iFillLevel is greater than  
DQSC_MAX_N_DL_DEL_REC)  
DQSE_INSERT_DELEGATE_FAILED (when delegate insert failed)  
DQSE_DELEGATE_DATA_BLOCKED  
DQSE_APP_NOT_STARTED  
Related functions  
SC_C_START_DQS  
SC_C_MAINT_CCU_DB  
SC_C_CLEAR_CCU_DB  
SC_C_CCU_APPLY_ONE  
3.11 SC_C_CLEAR_CCU_DB  
Purpose  
This function clears the delegate database in the CCU.  
Availability  
This function is available in CCU system mode congress. As with SC_C_MAINT_CCU_DB this function  
returns the error DQSE_DELEGATE_DATA_BLOCKED if another application is currently using the delegate  
database in the CCU.  
Parameter structure for the function  
The function has no additional parameters.  
Response structure from the function  
The function has no response parameters.  
Error codes returned  
DQSE_NOERROR  
DQSE_DELEGATE_DATA_BLOCKED  
DQSE_APP_NOT_STARTED  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 14  
Related functions  
SC_C_START_DQS  
SC_C_MAINT_CCU_DB  
SC_C_DOWNLOAD_CCU_DB  
SC_C_CCU_APPLY_ONE  
3.12 SC_C_CCU_APPLY_ONE  
Purpose  
With this function it is possible to add or update just one record in the delegate database in the CCU.  
Note that using this function you can only add or update a record of an existing database on the CCU. You  
cannot create a database using this function.  
The delegateId as present in the structure is used to determine if the record will be added or updated:  
When the delegateId is not present in the database, the record will be added to the database.  
When the delegateId already exist in the database, the record of that delegate will be updated.  
Only the following fields may be changed:  
wUnitNr  
Unit number where the delegate resides  
Desk language of the delegate  
Voting weight of the delegate  
Microphone authorisation  
Voting authorisation  
Intercom authorisation  
iDesklang  
lVWeight  
bMicAut  
bVotingAut  
bInterAut  
szSline  
The screenline of the delegate  
All other fields of the structure must have the same value as the information stored in the database.  
Availability  
This function is available in CCU system mode congress.  
Parameter structure for the function  
DQST_PERDELEGATE  
tDelegate (for description see section 3.9)  
Response structure from the function  
The function has no response parameters.  
Error codes returned  
DQSE_NOERROR  
DQSE_UPD_DEL_UNIT_IN_USE  
DQSE_UPD_DEL_CARD_CHANGED  
DQSE_UPD_DEL_PIN_CHANGED  
DQSE_UPDATE_DELEGATE_FAILED  
DQSE_INSERT_DELEGATE_FAILED  
DQSE_NO_DATABASE  
(if somebody else is using default seat)  
(if a card code change is detected)  
(if a pin code change is detected)  
(database function to update delegate record failed)  
(database function to insert delegate record failed)  
(No database available)  
DQSE_APP_NOT_STARTED  
Related functions  
SC_C_START_DQS  
SC_C_MAINT_CCU_DB  
SC_C_DOWNLOAD_CCU_DB  
SC_C_CLEAR_CCU_DB  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 15  
4
System Configuration notifications  
4.1  
Introduction  
This chapter defines the set of update notifications concerning SC send by the CCU.  
4.1.1 Update Notification item explanation  
Each description consists of the following items:  
Purpose  
A global description of the purpose of the notification.  
Notify structure with this update  
The information passed with the update notification.  
4.1.2 Unit/user event relations  
In the previous chapter a description is given of each remote function with a summary of update notifications  
being the result of executing that function. However, update notifications are also the results of user actions  
done on the actual units or CCU’s. This section gives unit/user event matrices for the SC application in which  
the possible user events are linked with the corresponding update notification(s) depending on the system  
set-up. For some events also the required remote functions to continue SC monitoring and maintaining are  
given.  
The update notifications themselves are described in the remaining sections of this chapter. The  
recommended functions from the SI group are described in chapter 5.  
UNIT-EVENT MATRIX  
Single CCU System (Remote Controller connected as specified in [SRS_INF])  
Event  
Switch On CCU  
Update Notification  
SC_C_CCU_REBOOT  
Continue with remote function  
SC_C_START_DCN  
Recommended before continuing:  
SC_C_GET_CCU_VERSIONINFO  
SC_C_GET_CCU_CONFIG  
SI_C_START_INSTALL and run  
installation as described in  
example-1 in Appendix Appendix C  
Recommended before continuing:  
SI_C_START_INSTALL and run  
installation as described in  
example-2 in Appendix Appendix C  
Connect a unit  
SC_C_CONNECT_UNIT  
Disconnect a unit  
SC_C_DISCONNECT_UNIT  
Multi CCU System (Remote Controller connected to the Master as specified in [SRS_INF])  
Event  
Update Notification  
<None>  
Continue with remote function  
Switch On a Slave  
CCU, while Master CCU  
is still off  
Switch On Master CCU  
SC_C_CCU_REBOOT  
SC_C_START_DCN  
Recommended before continuing:  
SC_C_GET_CCU_VERSIONINFO  
SC_C_GET_CCU_CONFIG  
SI_C_START_INSTALL and run  
installation as described in  
example-1 in Appendix Appendix C  
Recommended before continuing on  
the unit connect updates:  
SI_C_START_INSTALL and run  
installation as described in  
example-2 in Appendix Appendix C  
Switch On a Slave CCU SC_C_CONNECT_SLAVE_CCU  
and a few seconds later for  
every unit connected to that  
Slave CCU separately  
SC_C_CONNECT_UNIT  
Switch Off a Slave  
CCU  
Connect a Unit  
SC_C_DISCONNECT_SLAVE_CCU  
SC_C_CONNECT_UNIT  
Recommended before continuing:  
SI_C_START_INSTALL and run  
installation as described in  
example-2 in Appendix Appendix C  
Disconnect a Unit  
SC_C_DISCONNECT_UNIT  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 16  
Single-Multi System, i.e. a Multi CCU system but one or more of the Slave CCU’s configured to run in Single  
Mode  
Event  
Update Notification  
Continue with remote function  
Remote Controller connected to CCU-A, a CCU configured to run in Single CCU mode  
Switch On CCU-A  
SC_C_CCU_REBOOT  
SC_C_START_DCN  
Recommended before continuing:  
SC_C_GET_CCU_VERSIONINFO  
SC_C_GET_CCU_CONFIG  
SI_C_START_INSTALL and run  
installation as described in  
example-1 in Appendix Appendix C  
Switch On the Master  
CCU  
<None>  
Switch On another CCU <None>  
(Slave or Single-  
Mode)  
Disconnect another  
CCU (Slave or Single-  
Mode)  
<None>  
Connect a unit to  
CCU-A.  
SC_C_CONNECT_UNIT  
Recommended before continuing:  
SI_C_START_INSTALL and run  
installation as described in  
example-2 in Appendix Appendix C  
Disconnect a unit  
from CCU-A.  
Connect a unit to  
another CCU (Slave or  
Single-Mode).  
SC_C_DISCONNECT_UNIT  
<None>  
Disconnect a unit  
from another CCU  
(Slave or Single-  
Mode).  
<None>  
Remote Controller connected to the Master CCU  
Switch On CCU-A  
Switch On the Master  
CCU.  
<None>  
SC_C_CCU_REBOOT  
SC_C_START_DCN  
Recommended before continuing:  
SC_C_GET_CCU_VERSIONINFO  
SC_C_GET_CCU_CONFIG  
SI_C_START_INSTALL and run  
installation as described in  
example-1 in Appendix Appendix C  
Recommended before continuing on  
the unit connect updates:  
SI_C_START_INSTALL and run  
installation as described in  
example-2 in Appendix Appendix C  
Switch On a Slave CCU SC_C_CONNECT_SLAVE_CCU  
and a few seconds later for  
every unit connected to that  
Slave CCU separately  
SC_C_CONNECT_UNIT  
Switch On another  
Single-Mode CCU  
Switch Off a Slave  
CCU  
Switch Off another  
Single-Mode CCU  
Connect a unit to  
CCU-A.  
<None>  
SC_C_DISCONNECT_SLAVE_CCU  
<None>  
<None>  
Disconnect a unit  
from CCU-A.  
<None>  
Connect a unit to a  
Slave CCU.  
SC_C_CONNECT_UNIT  
Recommended before continuing:  
SI_C_START_INSTALL and run  
installation as described in  
example-2 in Appendix Appendix C  
Disconnect a unit  
from a Slave CCU.  
Connect a unit to  
another Single-Mode  
CCU.  
SC_C_DISCONNECT_UNIT  
<None>  
Disconnect a unit  
from another Single-  
Mode CCU.  
<None>  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 17  
4.2  
SC_C_CCU_REBOOT  
Purpose  
Notifies the remote controller that the CCU has restarted. This notification is always send at start-up of the  
CCU and is the only notification message send by the CCU till the update request function  
SC_C_START_DCN is executed.  
This notification should be monitored to detect a restart of the CCU. The remote controller should take  
appropriate actions to restore the settings.  
Notify structure with this update  
The update comes with the same structure as used for the response of the remote function  
SC_C_GET_CCU_VERSIONINFO (section 3.5).  
4.3  
SC_C_CONNECT_UNIT  
Purpose  
Notifies the remote controller that a new unit has connected to the CCU. The remote controller can use this  
notification to add this unit to its functionality.  
Notify structure with this update  
The update uses the following structure:  
SC_T_UNIT_DATA  
tUnitData;  
where:  
tUnitData  
Information about the unit that is connected. The elements  
present in the structure are defined in section 3.6.  
4.4  
SC_C_DISCONNECT_UNIT  
Purpose  
Notifies the remote controller that a unit has lost his connection with the CCU (i.e. the unit is disconnected  
from the ACN-trunk). This notification informs the remote controller that the unit is no longer available.  
Notify structure with this update  
The update comes along with the same structure as defined in section 4.3.  
4.5  
SC_C_CONNECT_SLAVE_CCU  
Purpose  
Notifies the remote controller that a slave-CCU has connected to the master-CCU.  
Notify structure with this update  
The update comes with the following structure:  
typedef struct  
{
BYTE  
WORD  
bySlaveId;  
wFillLevel;  
SC_T_UNIT_DATA tConnectedUnits[SC_C_CLUSTER_MAX];  
} SC_T_CCU_CONNECT;  
where:  
bySlaveId  
wFillLevel  
The identification number of the slave-CCU involved.  
The number of units present in the tConnectedUnits array. Only  
this amount of array elements is transmitted.  
tConnectedUnits  
A list of units that are connected to the slave in question. This  
means that all units reported in the list are also connected.  
Each list element is defined as a SC_T_UNIT_DATA structure  
which is defined in section 3.6.  
Note: Although the list is defined with SC_C_CLUSTER_MAX  
elements, only the maximum number of units possible for  
one slave will be transmitted.  
Currently the wFillLevel parameter will always be zero. Due to the nature of the units and the control flow  
used with the CCU (slave and master), each unit will connect itself using the notification  
SC_C_CONNECT_UNIT. Therefor no units are reported in this list. Future extension in the software could  
build a list of units connected to a slave. That list should then be reported in the tConnectedUnits list.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 18  
4.6  
SC_C_DISCONNECT_SLAVE_CCU  
Purpose  
Notifies the remote controller that the master-CCU has lost connection to one of his slave-CCU’s. Along with  
this notification a list of all units connected to that slave is send. This notification tells the remote controller  
that the listed units are no longer available.  
Notify structure with this update  
The update comes with the following structure:  
typedef struct  
{
BYTE  
WORD  
bySlaveId;  
wFillLevel;  
SC_T_UNIT_DATA tDisconnectedUnits[SC_C_CLUSTER_MAX];  
} SC_T_CCU_DISCONNECT;  
where:  
bySlaveId  
wFillLevel  
The identification number of the slave-CCU involved.  
The number of units present in the tDisconnectedUnits array.  
Only this amount of array elements is transmitted.  
tDisconnectedUnits  
A list of units that are connected to the slave in question at the  
moment of disconnecting the slave. This means that all units  
reported in the list are also disconnected. Each list element is  
defined as a SC_T_UNIT_DATA structure which is defined in  
section 3.6.  
Note: Although the list is defined with SC_C_CLUSTER_MAX  
elements, only the maximum number of units possible for  
one slave will be transmitted.  
This notification differs from SC_C_CONNECT_SLAVE_CCU such that wFillLevel and the  
tDisconnectedUnits array does inform the remote controller about units being disconnected together with this  
Slave-CCU. This implies that the units listed in the ‘tDisconnectedUnits’ do not notify themselves as  
disconnected with SC_C_DISCONNECT_UNIT.  
4.7  
SC_C_CCU_MODE_CHANGE  
Purpose  
Notifies the remote controller that the CCU changed its operation mode. For more information about the  
different modes see 3.5.  
Notify structure with this update  
typedef struct  
{
WORD  
WORD  
wCurrentMode;  
wNewMode;  
} SC_T_CCU_MODE_CHANGE;  
where:  
wCurrentMode  
The current CCU system mode, so before the mode  
change. Possible system mode values are defined in the  
bySystemMode field of the structure used within the  
function SC_C_GET_CCU_VERSIONINFO (see section  
3.5 ).  
wNewMode  
The new CCU system mode, so after the mode change.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 19  
5
System Installation Functions  
5.1  
Introduction  
The system installation functions provide functionality to connect unit identification with the seat numbers  
used within the congress-hall. This process is also called seat-assignment. This chapter defines the set of  
remote functions needed for system installation. Each description is according to the definition given in  
section 3.1.1.  
5.2  
SI_C_START_INSTALL  
Purpose  
Start the installation mode. The remote controller can choose among 2 modes of installation, which are:  
Mode Description  
SI_C_GLOBAL_INSTALL_MODE  
Global installation mode. When activating this mode, the CCU stops all  
applications running and only runs the installation application. When the  
function is successfully executed, the CCU has changed the system mode  
from congress to config.  
Entering the system mode config enables the update notification  
SI_C_REGISTER_UNIT which informs the remote controller about  
someone pressing a soft-key on a unit. The remote controller must use this  
notification message to link the unit with a seat.  
By pressing a soft-key on all units in order of the seat-numbers the remote  
controller can build a list of units with the seat-numbers as index. An  
example using this mode is presented in appendix Appendix C.  
SI_C_OPERATIONAL_INSTALL_MODE  
Operational installation mode. During this mode all applications keep on  
running. The CCU remains in the congress mode.  
No special update notification for registration will be enabled. The remote  
controller must select a proposed unit and the seat-number must be  
searched to link them together.  
To finish the installation the remote controller must execute the function SI_C_STOP_INSTALL.  
Availability  
This function is available in CCU system mode congress.  
Parameter structure for the function  
The function requires the following information as parameter:  
WORD  
wInstallMode;  
where:  
wInstallMode  
The installation mode to be used. This parameter can have one  
of the following values:  
SI_C_GLOBAL_INSTALL_MODE  
SI_C_OPERATIONAL_INSTALL_MODE  
Response structure from the function  
The function has no response parameters.  
Error codes returned  
SI_E_NOERROR  
SI_E_FAILED  
(SI mode already in use)  
Update Notifications  
SC_C_CCU_MODE_CHANGE  
Related functions  
SI_C_STOP_INSTALL  
SI_C_SELECT_UNIT  
5.3  
SI_C_STOP_INSTALL  
Purpose  
This function stops the installation started with the function SI_C_START_INSTALL. The CCU will return to  
normal congress mode if that is not the current system mode. The selected units will be deselected.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 20  
Note that:  
Upon communication loss this function will be activated, if SI_C_START_INSTALL  
was activated.  
Availability  
This function is available in CCU system mode config.  
Parameter structure for the function  
The function has no additional parameters.  
Response structure from the function  
The function has no response parameters.  
Error codes returned  
SI_E_NOERROR  
SI_E_FAILED  
(another controller has the SI mode in use)  
Update Notifications  
SC_C_CCU_MODE_CHANGE  
Related functions  
SI_C_START_INSTALL  
SI_C_SELECT_UNIT  
5.4  
SI_C_SELECT_UNIT  
Purpose  
Select a unit for linking to a seat by means of flashing all LED’s on the unit. Only one unit can be selected at  
the same time. When the second unit is selected the first unit is deselected automatically before the selection  
of the second.  
This function will only select a unit if the unit selected represents an installable unit. An installable unit is an  
unit which can be assigned with a seat number.  
Installable unit types are  
DCNC_UNIT_DELEGATE  
DCNC_UNIT_CHAIRMAN  
DCNC_UNIT_DELEGATE_CARD  
DCNC_UNIT_DUAL_MIC  
DCNC_UNIT_FLUSH_CHAIRMAN  
DCNC_UNIT_FLUSH_DELEGATE  
DCNC_UNIT_2000_DELEGATE  
DCNC_UNIT_2000_CHAIRMAN  
DCNC_UNIT_2000_DELEGATE_CARD  
DCNC_UNIT_DAI_CHAIRMAN  
DCNC_UNIT_DISC_DELEGATE  
DCNC_UNIT_DISC_CHAIRMAN  
DCNC_UNIT_FLUSH_DEL_NODISP  
DCNC_UNIT_FLUSH_CHR_NODISP  
When called during the installation mode SI_C_GLOBAL_INSTALL_MODE the microphone of the unit will be  
turned on as long as the unit is selected.  
Availability  
This function is available in CCU system modes config and congress.  
Parameter structure for the function  
The function requires the following structure as parameter:  
typedef struct  
{
WORD  
BOOLEAN  
wUnitId;  
bSelectOn;  
} SI_T_SELECT_UNIT;  
where:  
wUnitId  
The unit identifier of the unit selected.  
bSelectOn  
TRUE: All LED’s of the unit will be flashing.  
FALSE: All LED’s of the unit will be off  
Response structure from the function  
The function has no response parameters.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 21  
Error codes returned  
SI_E_NOERROR  
SI_E_FAILED  
SI_E_INVALID_UNITTYPE  
Related functions  
SI_C_START_INSTALL  
SI_C_STOP_INSTALL  
5.5  
SI_C_SET_MASTER_VOL  
Purpose  
To set the master audio volume. The audio loudness of the delegates loudspeakers, line-out and rec-out can  
be changed.  
Availability  
This function is available in CCU system modes config and congress.  
Parameter structure for the function  
WORD  
wMasterVolume;  
where:  
wMasterVolume  
The new overall volume setting for the system. A number in  
the range 0..15. In this range, a zero value means mute all  
delegate loudspeakers. The values 1 up untill 15 correspond  
with an audio amplification of -14dB up untill 0dB in steps of  
1 dB.  
Response structure from the function  
The function has no response parameters.  
Error codes returned  
SI_E_NOERROR  
SI_E_FAILED  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 22  
6
System Installation notifications  
6.1  
Introduction  
This chapter defines the set of update notifications concerning SI send by the CCU. Each description is  
according to the definition given in section 4.1.1.  
6.1.1 Unit/user event relations  
As for the SC application, update notifications for SI are also the results of user actions done on the actual  
units. This section gives a unit/user event matrix for the SI application in which the possible user events are  
linked with the corresponding update notification(s). For some events also the required remote functions to  
continue the System Installation process are given.  
The update notifications themselves are described in the remaining sections of this chapter.  
UNIT-EVENT MATRIX  
Event  
Update Notification  
Continue with remote function  
Installation not yet started  
Press a Soft-key on  
a unit  
<None>  
Started Installation with SI_C_START_INSTALL (SI_C_GLOBAL_INSTALL_MODE)  
Press a Soft-key on  
a unit  
SI_C_REGISTER_UNIT  
SI_C_SELECT_UNIT  
See example-1 in Appendix Appendix  
C
Started Installation with SI_C_START_INSTALL (SI_C_OPERATIONAL_INSTALL_MODE)  
Press a Soft-key on  
a unit  
<None>  
6.2  
SI_C_REGISTER_UNIT  
Purpose  
Notifies the remote controller that during global installation (which implies that the CCU is in config mode, see  
SI_C_START_INSTALL section 5.2) a soft key is pressed on a installable unit. A installable unit is a unit  
which can be assigned with a seat number.  
An overview of installable unit types is given in section 5.4.  
The remote controller should use this update to assign a seat number to the unit identifier given with this  
update notification.  
Notify structure with this update  
The update comes with the following structure:  
typedef struct  
{
WORDwUnitId;  
BYTEbyUnitType;  
} SI_T_UNIT_STRUCT;  
where:  
wUnitId  
The unit identifier of a unit. Also called unit-number.  
byUnitType  
The type of the unit. The different unit types possible are given  
in section 3.6.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 23  
APPENDIX A. VALUES OF THE DEFINES  
In this document a lot of definitions are given, which have values connected to them. In this appendix all  
defines will be connected to their values.  
The values are presented in ‘C’-syntax and are grouped on related purpose.  
#define DCNC_APP_SI 17  
#define DCNC_APP_SC 16  
#define SC_C_MAINT_CCU_DB  
#define SC_C_CLEAR_CCU_DB  
MKWORD (1,DCNC_APP_SC)  
MKWORD (2,DCNC_APP_SC)  
#define SC_C_GET_CCU_VERSIONINFO MKWORD (6,DCNC_APP_SC)  
#define SC_C_START_DCN MKWORD (7,DCNC_APP_SC)  
#define SC_C_STOP_DCN  
#define SC_C_CONNECT_UNIT  
#define SC_C_DISCONNECT_UNIT  
#define SC_C_GET_CCU_CONFIG  
#define SC_C_CONNECT_SLAVE_CCU  
MKWORD (8,DCNC_APP_SC)  
MKWORD (9,DCNC_APP_SC)  
MKWORD (10,DCNC_APP_SC)  
MKWORD (12,DCNC_APP_SC)  
MKWORD (13,DCNC_APP_SC)  
#define SC_C_DISCONNECT_SLAVE_CCUMKWORD (14,DCNC_APP_SC)  
#define SC_C_CCU_REBOOT MKWORD (15,DCNC_APP_SC)  
#define SC_C_CCU_MODE_CHANGE  
#define SC_C_CCU_APPLY_ONE  
MKWORD (16,DCNC_APP_SC)  
MKWORD (17,DCNC_APP_SC)  
#define SC_C_CHECK_LINK MKWORD (18,DCNC_APP_SC)  
#define SC_C_DOWNLOAD_CCU_DB  
MKWORD (20,DCNC_APP_SC)  
#define SC_C_START_DQS MKWORD (21,DCNC_APP_SC)  
#define SC_C_STOP_DQS  
MKWORD (22,DCNC_APP_SC)  
#define SI_C_SELECT_UNIT MKWORD (1,DCNC_APP_SI)  
#define SI_C_START_INSTALL  
#define SI_C_STOP_INSTALL  
#define SI_C_REGISTER_UNIT  
#define SI_C_SET_MASTER_VOL  
MKWORD (4,DCNC_APP_SI)  
MKWORD (5,DCNC_APP_SI)  
MKWORD (9,DCNC_APP_SI)  
MKWORD (10,DCNC_APP_SI)  
#define DBSC_MAX_ACT_UNIT  
#define DBSC_MAX_DELEGATE  
#define DBSC_NCHAR_SCREENLINE  
512 single CCU system, 4000 multi CCU system  
DBSC_MAX_ACT_UNIT  
33  
#define DCNC_UNIT_DELEGATE  
#define DCNC_UNIT_CHAIRMAN  
1
2
(unit LBB3550/00 or LBB3551/00)  
(unit LBB3554/00)  
#define DCNC_UNIT_DELEGATE_CARD 3  
(unit LBB3550/10 or LBB3551/10)  
(unit LBB3520/00)  
(unit LBB3535/00)  
#define DCNC_UNIT_INTERPRETER  
#define DCNC_UNIT_DUAL_MIC  
4
5
#define DCNC_UNIT_PC6  
(Network card for PC LBB3510/00)  
#define DCNC_UNIT_DATA_COMM  
#define DCNC_UNIT_CCU_CONTROL  
7
8
(Data Distribution board LBB3512/00)  
(CCU LBB3500/xx)  
#define DCNC_UNIT_FLUSH_CHAIRMAN 10 (unit LBB3540/00 set to ‘chairman’)  
#define DCNC_UNIT_FLUSH_DELEGATE 11 (unit LBB3540/00 set to ‘delegate’)  
#define DCNC_UNIT_AMBIENT_MIC  
13  
#define DCNC_UNIT_DATA_COMM_RS23215  
#define DCNC_UNIT_2000_DELEGATE 17 (unit LBB3544 or LBB3545)  
#define DCNC_UNIT_2000_CHAIRMAN 18 (unit LBB3546)  
#define DCNC_UNIT_2000_DELEGATE_CARD 19  
(unit LBB3547)  
(unit LBB3513)  
#define DCNC_UNIT_AUDIO_IO  
20  
#define DCNC_UNIT_DAI_CHAIRMAN  
21  
#define DCNC_UNIT_DISC_DELEGATE 22  
#define DCNC_UNIT_DISC_CHAIRMAN 23  
#define DCNC_UNIT_FLUSH_DEL_NODISP  
#define DCNC_UNIT_FLUSH_CHR_NODISP  
26  
27  
#define DCNC_UNIT_ENTRANCE  
#define DCNC_UNIT_EXIT  
30  
31  
#define DCNC_VER_ENGLISH 0  
#define DCNC_VER_FRENCH 1  
#define DCNC_VER_GERMAN 2  
#define DCNC_VER_ITALIAN 3  
#define DCNC_VER_SPANISH 4  
#define DCNC_VER_SIXTH 5  
(depending on downloaded OMF-file)  
#define SC_C_LBB3500_00 0  
#define SC_C_LBB3500_10 1  
#define SC_C_LBB3500_30 3  
#define SC_C_LBB3511_00 4  
#define SC_C_STANDALONE 0x01  
#define SC_C_EXTENDED  
0x02  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 24  
#define SC_C_SINGLETRUNC 0x04  
#define SC_C_MULTITRUNC 0x08  
#define SC_C_MASTER 0x10  
#define SC_C_SLAVE 0x20  
#define SI_C_GLOBAL_INSTALL_MODE 1  
#define SI_C_OPERATIONAL_INSTALL_MODE 2  
#define SC_C_DQS_CONTROL 1  
#define SC_C_MAX_HARDWARE_INFO  
#define SC_C_CLUSTER_MAX 1500  
#define SC_C_MAX_SOFTWARE_INFO  
50  
29  
#define SC_C_MAX_VERSION_LENGTH 50  
#define DQSC_MAX_N_DL_DEL_REC  
#define VERSION_C_LENGTH 50  
50  
#define MAX_CARD_CODE  
999999999  
#define MAX_VOTE_WEIGTH 99999999  
#define DCNC_SM_DOWN0  
#define DCNC_SM_INIT1  
#define DCNC_SM_CONFIG 2  
#define DCNC_SM_CONGRESS 3  
#define DCNC_SM_MAINTENANCE  
#define DCNC_SM_DOWNLOAD 5  
4
#define TRUE1  
#define FALSE  
0
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 25  
APPENDIX B. ERROR CODES  
Responses returned upon a remote function request contain an error field (‘wError’). In this appendix an  
overview is given of the possible errors and their values.  
System Configuration Error code  
Explanation  
Value  
SC_E_NOERROR  
0
The execution of the remote function was successful.  
SC_E_FAILED  
The execution of the remote function failed. This error code is  
1
currently not used.  
System Installation Error code  
Explanation  
Value  
SI_E_NOERROR  
0
1
The execution of the remote function was successful.  
SI_E_FAILED  
The execution of the remote function failed. Only one remote  
controller (currently using the installation mode) may use this  
remote function.  
SI_E_INVALID_UNITTYPE  
The selected unit represents no seat. For example the entry exit  
4323  
unit and interpreter desks.  
Database Query Services Error code  
Explanation  
Value  
DQSE_NOERROR  
0
The execution of the remote function was successful.  
DQSE_SET_PINSIZE_FAILED  
Setting a new size for the PIN Code into the Delegate Database  
10401  
10402  
10403  
10404  
failed.  
DQSE_DELEGATE_LIST_TOO_BIG  
The iFillLevel parameter in SC_C_MAINT_CCU_DB has a value  
larger then DQSC_MAX_N_DL_DEL_REC.  
DQSE_INSERT_DELEGATE_FAILED  
Inserting the current DQST_PERDELEGATE structure into the  
Delegate Database failed.  
DQSE_UPDATE_DELEGATE_FAILED  
Updating the delegate database with the current  
DQST_PERDELEGATE structure failed.  
DQSE_UPD_DEL_PIN_CHANGED  
Update failed because the PIN code changed.  
DQSE_UPD_DEL_CARD_CHANGED  
Update failed because the cardcode is changed.  
DQSE_UPD_DEL_UNIT_IN_USE  
10405  
10406  
10407  
Update of database failed because someone else is already using  
the proposed default seat.  
DQSE_PENDING_REQUEST  
10408  
Setting/updating the Delegate Database failed because a delegate  
with a pending Request to Speak was tried to delete from the  
database.  
DQSE_DELEGATE_DATA_BLOCKED  
10409  
10410  
Updating the delegate database with the current  
DQST_PERDELEGATE structure failed.  
DQSE_NO_DATABASE  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 26  
Database Query Services Error code  
Explanation  
The use of function SC_C_CCU_APPLY_ONE is not possible,  
because currently there is no database present in the CCU.  
DQSE_APP_NOT_STARTED  
Value  
10411  
10412  
10413  
10414  
The remote controller has not called the SC_C_START_DQS yet.  
Therefore any remote function call to access the database fails with  
this error.  
DQSE_INCONTROL_THIS_CHANNEL  
The database is already under control by this remote controller (on  
the same channel). Probably you have called the  
SC_C_START_DQS function twice.  
DQSE_INCONTROL_OTHER_CHANNEL  
The SC_C_START_DQS function could not finish successfully  
because the database is already controlled by another remote  
controller using another channel.  
DQSE_ILLEGAL_CONTROL_TYPE  
The control-type passed to the function SC_C_START_DQS is not  
within range of valid values (see appendix Appendix A for the  
correct control-type values).  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 27  
APPENDIX C. EXAMPLES  
In the examples below the remote functions and update notifications, that are defined in this document as  
constant values for the wFnId parameter of the message (see [SRS_INF]), are presented as functions  
described in a ‘C’ syntax. The parameter structures of these functions are according the input, output or notify  
structures described in the appropriate section.  
For every function is assumed that the function will create his structure, transport the parameters to the CCU  
and waits for the result information coming from the CCU.  
For both the remote functions as the update notifications the same names are used as their identifier, but  
without the constant mark “C” and using mixed case names. So, e.g. remote function  
SC_C_CONNECT_UNIT shall be referenced as function as:  
SC_Connect_Unit (SC_T_UNIT_DATA tUnitData);  
C.1. Assigning seats using global installation  
This example shows how the remote controller can assign his seats to the unit-numbers present in the  
conference hall.  
Assumed is that the conference hall has a number of seats numbered starting with 1. For this proposed  
installation one person must walk through the conference hall and press one of the soft-keys on the units in  
order of the seats (starting with seat 1). On each unit a soft-key is only pressed once.  
For this seat assignment the global installation mode of the CCU will be used. therefore we start with  
activating that mode.  
error = SI_Start_Install (SI_C_GLOBAL_INSTALL_MODE);  
if (error != SI_E_NOERROR)  
{
/* do error handling */  
}
After this function the CCU is in global installation mode, all displays are off and no applications are running.  
We now initialise the current seat and unit-number, assuming seatnumbers are chosen to be purely numeric:  
wCurrentSeatNumber = 1;  
The system is now ready to accept the key-presses on the units in order of the seats. When a soft-key is  
pressed the CCU sends a notification. During the processing of that function we select the unit where the key  
is pressed, and assign the current seat number to the provided unit number.  
This result in the following function:  
void SI_Register_Unit (SI_T_UNIT_STRUCT *tUnitStruct)  
{
/* First turn off the previous selected unit */  
/* ........ */  
error = SI_Select_Unit (tUnitStruct->wUnitId, TRUE);  
if (error != SI_E_NOERROR)  
{
/* do error handling */  
}
/* assign the current seat to the unit */  
MyAssignSeat (wCurrentSeatNumber, tUnitStruct->wUnitId);  
/* Increment to the next seat */  
wCurrentSeatNumber = wCurrentSeatNumber + 1;  
/* and save the unitId to turn off during the assignment of the next seat */  
/* ........ */  
}
Note that this function is only an example to shown how the interaction between update notifications and  
remote functions can appear. For instance, when you press a soft-key the second time, this function will fail.  
Better is to look if the selected unit has already a seat assigned. If not, the assign and increment, if assigned,  
just keep the assignment.  
When done with all seats present in the conference hall, we can leave the global installation mode. This is  
done using the following sequence:  
/* first turn off the last selected unit */  
/* ........ */  
error = SI_Stop_Install ();  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 28  
if (error != SI_E_NOERROR)  
{
/* do error handling */  
}
This ends the global seat assignment. The remote controller has now a complete list of all seats and their  
corresponding unit-numbers.  
C.2. Replacing defective units during operation  
This example shows how the remote controller can assign a seat to a unit in the conference hall which is  
replaced by a new unit (due to failure of the old unit).  
Assumed is that previously all units have been assigned a seat-number on the remote controller. After  
detection that a unit fails, the following actions are performed by the technical staff of the conference hall:  
1. The defective unit is removed from the system. Note that disconnecting the unit also may  
disconnect other (chained) units.  
2. A new unit is inserted into the unit-chain and connected to the system.  
3. The new unit is de-initialised, and initialised again to be sure that the added unit has no  
address conflict with other units.  
During these actions the following notifications are reported to the remote controller (assumed is that the  
application SC is registered by the CCU:  
Microphone off notifications if any of the disconnected units has their microphone on or  
had a pending request (present in the Request To Speak list).  
SC_C_DISCONNECT_UNIT for all units in the chain disconnected. The remote controller  
remembers these units to disable the functionality.  
SC_C_CONNECT_UNIT for all units connected. Most of the unit-numbers are known in  
the disconnect-list and can be restored (e.g. the functionality will be enabled). The new  
unit(s) connected to the system is not known.  
For these units the remote controller must start the operational installation mode. The operational installation  
mode is activated using the following remote function request:  
error = SI_Start_Install (SI_C_OPERATIONAL_INSTALL_MODE);  
if (error != SI_E_NOERROR)  
{
/* do error handling */  
}
After this the CCU has enabled the operational installation mode. The remote controller can start the  
sequence to assign the new unit-numbers to seats not yet assigned.  
while (there are new units and unassigned seats)  
{
WORD wUnitId;  
wUnitId = First_new_unit_available;  
/* select the unit */  
error = SI_Select_Unit (wUnitId, TRUE);  
if (error != SI_E_NOERROR)  
{
/* do error handling */  
}
/* Let the operater determine which seat should be assigned to the selected  
unit. Normally the operator will view which unit is flashing, checks the  
seat-number and pass the seat-number found to the remote controller.  
The seat-number is stored in the variable ‘wSeatNumber’  
*/  
/* assign the current seat to the unit */  
MyAssignSeat (wSeatNumber, wUnitId);  
/* assignment finished, deselect the unit */  
error = SI_Select_Unit (wUnitId, FALSE);  
if (error != SI_E_NOERROR)  
{
/* do error handling */  
}
}
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 29  
After this sequence handling the newly added units are again assigned to seats. This also finished the  
operational installation mode, so we can leave the installation mode.  
error = SI_Stop_Install ();  
if (error != SI_E_NOERROR)  
{
/* do error handling */  
}
The remote controller can now continue with normal operation.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
SC & SI Remote Interface Description  
en | 30  
APPENDIX D. ERROR CODES  
Responses returned upon a remote function request contain a error field (‘wError’). In this appendix an  
overview is given of the possible errors and their values.  
Remote Function Services Error code  
Explanation  
Value  
RFSE_BADFUNCTIONID  
10901  
The remote function called is not registered by the Remote  
Function Services. Either the function does not exist or the CCU  
is operating in a wrong mode.  
RFSE_ALLOCFAILED  
10904  
10907  
The requested data-area for the function response could not be  
allocated. The CCU went out of memory during the remote  
function call.  
RFSE_NOACCESSPERMISSION  
The remote function is not accessible. The remote interface is  
not installed.  
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description  
 
© 2003 Bosch Security Systems B.V.  
Data subject to change without notice  
December 2003 | SC & SI Remote Interface Description  
 

Beko Washer WMB 651241 L User Manual
Blackberry Cell Phone 9300 Version 50 User Manual
Black Box Network Hardware Hardened Ethernet Extender User Manual
Blue Rhino Outdoor Fireplace WAD850SP User Manual
Brother Label Maker DK1201 User Manual
Cadco Food Warmer CMLB C2RT User Manual
Canon Camcorder 3i MC User Manual
Canon Camcorder 8152B005 User Manual
Chicago Electric Cordless Sander 67707 User Manual
Christie Digital Systems DVR CINEX35 User Manual