Hardened VDSL Ethernet Extender
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo
descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a
personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La
colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede
bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de
aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como
radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que
producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en
el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo
no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni
pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los
contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del
fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un
largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre
la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
3
Hardened VDSL Ethernet Extender
Preface
This manual describes how to install and use the Hardened VDSL Ethernet Extender.
The Hardened VDSL Ethernet Extender introduced here provides one channel for
Ethernet over VDSL.
The Hardened VDSL Ethernet Extender fully complies with IEEE802.3 10Base-T and
IEEE802.3u 100Base-TX/FX standards.
In this manual, you will find:
y Product overview
y FEATURES ON THE HARDENED VDSL ETHERNET EXTENDER
y Illustrative LED functions
y Installation instructions
y Specifications
4
Hardened VDSL Ethernet Extender
Introduction
The Hardened VDSL Ethernet Extender provides one channel for Ethernet over VDSL.
This Hardened VDSL Ethernet Extender solution is perfectly fitted in the industrial
applications or rugged environment.
Product Overview
Product Features
y Meets NEMA TS1/TS2 Environmental requirements such as temperature, shock,
and vibration for traffic control equipment
y
y
y
Meets IEC61000-6-2 EMC Generic Standard Immunity for industrial environment
Operates transparent to higher layer protocols such as TCP/IP
Ethernet Port: Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps,
full/half-duplex; Auto MDI/MDIX
y
VDSL port: Symmetrical on the VDSL, high-speed full-duplex 50Mbps
communications link over existing copper telephone line
y
y
One DIP switch for configuring Local (Loc) and Remote (Rmt)
Ten speeds with speed indicator LEDs on front panel of unit, up to 50Mbps @
about 300meters (984ft.), down to 1Mbps @ about 1,900meters (6,233ft.)
Operating voltage and Max. current consumption: 0.225A @ 12VDC, 0.113A @
24VDC. Power consumption: 2.7W Max.
y
y
Power Supply: Redundant 12-30VDC Terminal Block power inputs and 12VDC
DC JACK with 100-240VAC external power supply
y
y
Operating temperature ranges from -34 to 74
Supports Din-Rail, Panel, or Rack Mounting installation
Packing List
When you unpack this product package, you will find the items listed below. Please
inspect the contents, and report any apparent damage or missing items immediately to
our authorized reseller.
6
Hardened VDSL Ethernet Extender
The Hardened VDSL Ethernet Extender
USER’S MANUAL
AC to DC Power Adaptor and Power Cable (optional)
7
Hardened VDSL Ethernet Extender
One-Channel Hardened VDSL Ethernet Extender
Ports
The Hardened VDSL Ethernet Extender provides one TX port and one VDSL port.
For the TX port, it uses RJ-45 connector and auto senses the speed of 10/100Mbps.
For the VDSL port, it uses RJ-11 and Terminal Block connectors and auto senses the
speed of 1/3/5/10/15/20/25/30/40/50Mbps.
VDSL Mode Settings
VDSL mode settings are made very simple by means of a DIP (Dual Inline Package)
switch on the top panel of the Hardened VDSL Ethernet Extender.
DIP switch
There is one pin on the DIP switch for VDSL mode settings. Refer to the table below
for more details.
Loc
Rmt
The device operates in local
mode
The device operates in remote
mode
8
Hardened VDSL Ethernet Extender
Front Panel & LEDs
LED Indicators
The LED indicators give you instant feedback on status of the Hardened VDSL
Ethernet Extender:
LEDs
State
Indication
Power on
Power1
Steady
Power2
Power3
Ethernet
Off
Power off
Steady
A valid Ethernet connection established
Transmitting or receiving Ethernet data
ACT stands for ACTIVITY
Flashing
Link/ACT
FDX
Neither valid Ethernet connection established nor
transmitting/receiving Ethernet data
Off
Ethernet Connection in full-duplex mode
FDX stands for FULL-DUPLEX
Steady
Off
Ethernet Connection in half-duplex mode
Ethernet over VDSL
Green
The VDSL port transmitting/receiving at 1Mbps, up to 1900M
The VDSL port transmitting/receiving at 3Mbps, up to 1800M
The VDSL port transmitting/receiving at 5Mbps, up to 1600M
The VDSL port transmitting/receiving at 10Mbps, up to 1400M
The VDSL port transmitting/receiving at 15Mbps, up to 1200M
The VDSL port transmitting/receiving at 20Mbps, up to 1000M
The VDSL port transmitting/receiving at 25Mbps, up to 800M
The VDSL port transmitting/receiving at 30Mbps, up to 700M
The VDSL port transmitting/receiving at 40Mbps, up to 600M
The VDSL port transmitting/receiving at 50Mbps, up to 300M
The device operates in remote mode
1
Amber
Green
2
Amber
Green
3
Amber
Green
4
Amber
Green
5
Amber
Remote
Local
Error
Steady
Steady
Steady
Steady
The device operates in local mode
Error occurred
Link
A valid VDSL connection established
9
Hardened VDSL Ethernet Extender
Installation
This chapter gives step-by-step installation instructions for the Hardened VDSL
Ethernet Extender.
Selecting a Site for the Equipment
As with any electric device, you should place the equipment where it will not be
subjected to extreme temperatures, humidity, or electromagnetic interference.
Specifically, the site you select should meet the following requirements:
• The ambient temperature should be between -34 to 74 degrees
Celsius.
• The relative humidity should be less than 95 percent, non-condensing.
• Surrounding electrical devices should not exceed the electromagnetic
field (RFC) standards.
• Make sure that the equipment receives adequate ventilation. Do not
block the ventilation holes of the equipment.
• The power outlet should be within 1.8 meters of the product.
DIN Rail Mounting
Fix the DIN rail attachment plate to the back panel of the Hardened VDSL Ethernet
Extender.
Installation: Place the Hardened VDSL Ethernet Extender on the DIN rail from above
using the slot. Push the front of the Hardened VDSL Ethernet Extender toward the
mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the Hardened VDSL Ethernet
Extender from the DIN rail.
10
Hardened VDSL Ethernet Extender
Connecting to Power
Redundant DC Terminal Block Power Inputs or 12VDC DC Jack:
12VDC DC Jack
Step 1: Connect the supplied AC to DC power adapter to the receptacle
on the topside of the Hardened VDSL Ethernet Extender.
Step 2: Connect the power cord to the AC to DC power adapter and
attach the plug into a standard AC outlet with the appropriate AC
voltage.
Redundant DC Terminal Block Power Inputs
There are two pairs of power inputs can be used to power up this device. You only need
to have one power input connected to run the Hardened VDSL Ethernet Extender.
Step 1: Connect the DC power cord to the plug-able terminal block on
the Hardened VDSL Ethernet Extender, and then plug it into a standard
DC outlet.
Step 2: Disconnect the power cord if you want to shut down the
Hardened VDSL Ethernet Extender.
Power Input Assignment
Power1
12VDC
DC Jack
+
-
+
-
12-30VDC
Power Ground
12-30VDC
Power Ground
Power2
Terminal Block
Power3
Earth Ground
DIP Switch Assignment
Loc
Rmt
The device operates in local mode
The device operates in remote mode
11
Hardened VDSL Ethernet Extender
Specifications
Applicable Standards
IEEE802.3 10Base-T
IEEE802.3u 100Base-TX
Ethernet over VDSL
Fixed Ports
1 x 10/100Mbps Ethernet port with RJ-45 connector
1 x Ethernet over VDSL port with RJ-11 and Terminal
Block connectors
Speed
10Base-T
10/20Mbps for half/full-duplex
100/200Mbps for half/full-duplex
100Base-TX
Ethernet over VDSL
1, 3, 5, 10, 15, 20, 25, 30, 40, 50Mbps
Switching Method
Forwarding rate
Cable
Store-and-Forward
14,880/148,810pps for 10/100Mbps
10Base-T
100Base-TX
2-pair UTP/STP Cat. 3, 4, 5 up to 100m
2-pair UTP/STP Cat. 5 up to 100m
Ethernet over VDSL Cross-over telephone wires
LED Indicators
Per Unit (3 LEDs)-
Power1, Power2, Power3
Per Port-
RJ-45 (2 LEDs): Link/ACT, FDX
RJ-11, Terminal Block (9 LEDs): Remote,
Local, Error, Link, 1, 2, 3, 4, 5
Dimensions
50mm (W) × 110mm (D) x 136mm (H)
(1.97” (W) x 4.33” (D) x 5.35” (H))
Weight
Power
0.8Kg (1.76lbs.)
Terminal Block: 12-30VDC
DC Jack: 12VDC, External AC/DC required
Operating Voltage &
Max.
0.225A @ 12VDC, 0.113A @ 24VDC
Current Consumption
Power Consumption
Operating Temperature
Storage Temperature
Humidity
2.7W Max.
-34°C ~ 74°C (-29°F ~ 165°F)
-40°C ~ 85°C (-40°F ~ 185°F)
10 ~ 95%, non-condensing
UL60950, EN60950, IEC60950
Safety
Emissions
FCC Part 15, Class A
CE: EN61000-6-2
EN61000-6-3
12
Hardened VDSL Ethernet Extender
Standards
ESD Standard (EN61000-4-2)
Radiated FRI Standards (EN61000-4-3)
Burst Standards (EN61000-4-4)
Surge Standards (EN61000-4-5)
Induced RFI Standards (EN61000-4-6)
Magnetic Field Standards (EN61000-4-8)
Voltage Dips Standards (EN61000-4-11)
Environmental Test Compliance:
Vibration Resistance (IEC60068-2-6)
Shock (IEC60068-2-27)
Free Fall (IEC60068-2-32)
NEMA TS1/2 Environmental requirements for
traffic control equipment
13
|