User Manual
VIRTUBE
VT250
2 x 50-Watt Guitar Amplifier with 2 Independent Channels,
VTC Tube Modeling, Dual FX and 2 Original BUGERA 12" Speakers
VT100 /VT50
100/60-Watt Guitar Amplifier with 2 Independent Channels,
VTC Tube Modeling, Dual FX and Original BUGERA 12" Speaker
VT100 H
100-Watt Guitar Amplifier Head with 2 Independent Channels,
VTC Tube Modeling and Dual FX
3
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
9. Do not defeat the safety purpose of the polarized
TO BIND MUSIC GROUP BY ANY EXPRESS OR IMPLIED
UNDERTAKING OR REPRESENTATION. THIS MANUAL
IS COPYRIGHTED. NO PART OF THIS MANUAL MAY
BE REPRODUCED OR TRANSMITTED IN ANY FORM
Important Safety
Instructions
or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding-type plug
has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the OR BY ANY MEANS, ELECTRONIC OR MECHANICAL,
provided plug does not fit into your outlet, consult an
electrician for replacement of the obsolete outlet.
INCLUDING PHOTOCOPYING AND RECORDING OF ANY
KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS
WRITTEN PERMISSION OF MUSIC GROUP IP LTD.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles,
and the point where they exit from the apparatus.
Terminals marked with this symbol carry
electrical current of sufficient magnitude
to constitute risk of electric shock.
ALL RIGHTS RESERVED.
© 2013 MUSIC Group IP Ltd.
Trident Chambers, Wickhams Cay, P.O. Box 146,
Road Town, Tortola, British Virgin Islands
11. Use only attachments/accessories specified by
the manufacturer.
Use only high-quality professional speaker cables with
¼" TS or twist-locking plugs pre-installed. All other
installation or modification should be performed only
by qualified personnel.
12. Use only with the
cart, stand, tripod, bracket,
or table specified by the
LIMITED WARRANTY
For the applicable warranty terms and conditions
and additional information regarding MUSIC Group’s
Limited Warranty, please see complete details online at
manufacturer, or sold with
the apparatus. When a cart
is used, use caution when
moving the cart/apparatus
combination to avoid
This symbol, wherever it appears,
alerts you to the presence of uninsulated
dangerous voltage inside the
enclosure - voltage that may be sufficient to constitute a
risk of shock.
injury from tip-over.
This symbol, wherever it appears,
alerts you to important operating and
maintenance instructions in the
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power supply cord or plug
is damaged, liquid has been spilled or objects have fallen
into the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has
been dropped.
accompanying literature. Please read the manual.
Caution
To reduce the risk of electric shock, do not
remove the top cover (or the rear section).
No user serviceable parts inside. Refer servicing to
qualified personnel.
Caution
To reduce the risk of fire or electric shock,
do not expose this appliance to rain and
15. The apparatus shall be connected to a MAINS socket
outlet with a protective earthing connection.
16. Where the MAINS plug or an appliance coupler is
used as the disconnect device, the disconnect device shall
remain readily operable.
moisture. The apparatus shall not be exposed to dripping
or splashing liquids and no objects filled with liquids,
such as vases, shall be placed on the apparatus.
Caution
These service instructions are for use
by qualified service personnel only.
To reduce the risk of electric shock do not perform any
servicing other than that contained in the operation
instructions. Repairs have to be performed by qualified
service personnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
LEGAL DISCLAIMER
TECHNICAL SPECIFICATIONS AND APPEARANCES
ARE SUBJECT TO CHANGE WITHOUT NOTICE AND
ACCURACY IS NOT GUARANTEED. BEHRINGER,
KLARK TEKNIK, MIDAS, BUGERA, AND TURBOSOUND
ARE PART OF THE MUSIC GROUP (MUSIC-GROUP.COM).
ALL TRADEMARKS ARE THE PROPERTY OF THEIR
RESPECTIVE OWNERS. MUSIC GROUP ACCEPTS NO
LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED
BY ANY PERSON WHO RELIES EITHER WHOLLY OR
IN PART UPON ANY DESCRIPTION, PHOTOGRAPH
OR STATEMENT CONTAINED HEREIN. COLORS AND
SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT.
MUSIC GROUP PRODUCTS ARE SOLD THROUGH
AUTHORIZED FULLFILLERS AND RESELLERS ONLY.
FULLFILLERS AND RESELLERS ARE NOT AGENTS OF
MUSIC GROUP AND HAVE ABSOLUTELY NO AUTHORITY
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
4
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
1. Introduction
Ensure adequate air supply and to avoid overheating do not place the unit
near radiators etc.
The demands placed on a guitar amp are nowadays very broad. A guitarist should
offer a wide array of sounds. That’s why it is very important to us to be able to
offer you maximum sound diversity as well as a variety of connection possibilities
with your VIRTUBE. Don’t worry: you will quickly master the VIRTUBE and learn
how to use all of its capabilities easily and intuitively. With its up-to-date
circuitry, the VIRTUBE features the functionality and reliability of a truly modern
guitar amp.
◊
Please make sure that all devices are properly grounded/earthed.
For your own safety, never remove or disable the ground/earth
conductors from the devices or on the power cords. The unit
must always be connected to the mains outlet with a protective
grounding connection.
1.1.1 Online registration
VTC Virtual Tube Circuitry
Please register your new BEHRINGER equipment right after your purchase
warranty carefully.
The specially developed VTC Virtual Tube Circuitry gives your sound the unique
vintage flavor of classic tube amps.
Should your BEHRINGER product malfunction, it is our intention to have it
repaired as quickly as possible. To arrange for warranty service, please contact
the BEHRINGER retailer from whom the equipment was purchased. Should your
BEHRINGER dealer not be located in your vicinity, you may directly contact
one of our subsidiaries. Corresponding contact information is included in the
original equipment packaging (Global Contact Information/European Contact
Information). Should your country not be listed, please contact the distributor
nearest you. A list of distributors can be found in the support area of our website
(http://behringer.com).
1.1 Before you get started
Your product was carefully packed at the factory to ensure safe transport.
Nevertheless, if the box is damaged inspect the unit immediately for signs
of damage.
◊
If the unit is damaged please do NOT return it to us, but notify your
dealer and the shipping company immediately; otherwise, claims for
damage or replacement may not be granted.
◊
◊
◊
Otherwise, always use the original box to prevent damage during
storage or transport.
Registering your purchase and equipment with us helps us process your repair
claims more quickly and efficiently.
Make sure that children cannot play unsupervised with the unit or
its packaging.
Thank you for your cooperation!.
Please ensure proper disposal of all packing materials.
Recylce whenever possible.
2. Control Elements
(2)
(9)
(17)
(1) (3) (4) (5) (6) (7) (8) (10) (11) (12) (13) (14) (15) (16) (18) (19) (20) (21) (22) (23)(24) (25) (26)
Fig. 2.1: VIRTUBE control elements (front panel)
2.1 Front panel
(7) The TREBLE control adjusts the treble frequencies on the CLEAN channel.
(1) The INPUT socket is the 1" connector for your guitar. Please use a standard
1" TS connector.
(8) Press the CHANNEL button to switch between the CLEAN and OVERDRIVE
channels. The channel LED lights up when the channel is activated. With all
models you can also switch between channels using the footswitch provided.
2.1.1 CLEAN CHANNEL
2.1.2 OVERDRIVE CHANNEL
(2) The CLEAN CHANNEL LED lights up when the CLEAN channel is active.
(3) The GAIN control determines the volume of the CLEAN channel.
(9) The OVERDRIVE CHANNEL LED lights up when the channel is active.
(10) The GAIN control determines the amount of gain applied and hence the
(4) The CRUNCH button (VT100FXH and VT100FX only) allows you to add some
degree of distortion in the OVERDRIVE channel.
slight distortion to your clean sound, giving it a bit of “dirt” or “crunch”.
(11) The OD1/OD2 button (VT100FXH and VT100FX only) switches between
(5) The BASS control in the EQ section allows you to raise or lower the bass
two different overdrive sounds.
frequencies on the CLEAN channel.
(12) The BASS control in the EQ section allows you to raise or lower the bass
(6) With the MIDDLE control you can raise or lower the midrange frequencies
frequencies on the OVERDRIVE channel.
on the CLEAN channel.
5
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
(13) With the MIDDLE control (VT100FXH and VT100FX only) you can raise or
2.1.4 MASTER section
lower the midrange frequencies on the OVERDRIVE channel.
(22) The MASTER VOLUME control adjusts both the overall volume and
(14) The TREBLE control adjusts the treble frequencies on the OVERDRIVE channel.
the line out/headphones volume.
(15) Use the CONTOUR control for additional, highly characteristic adjustment
of the midrange, allowing you to easily create traditional as well
as ultra-modern guitar sounds.
(23) The VTC push button activates and deactivates the VTC Virtual Tube Circuitry.
(24) The CD IN connector allows you to connect the output signal of a CD player,
tape deck, or CD/MD walkman. For example, you can play back music CDs or
CDs accompanying a guitar tutor while practising. This connector can also
be used as a LINE OUT output. In this case, the guitar signal is output with no
speaker simulation applied and can be routed to an external amp or mixing
console. This will not mute the VIRTUBE’s built-in loudspeaker.
(16) The VOLUME control adjusts the volume level of the OVERDRIVE channel.
2.1.3 DIGITAL FX
(17) The DIGITAL FX LED lights up when the effects processor is active.
(18) Use the FX PRESET control to select one of 16 effects.
(25) The LINE OUT/PHONES jack is for headphones connection. Internal speaker
simulation is applied to the headphones signal in order to produce an
authentic signal. The VIRTUBE’s built-in loudspeaker is muted when this
connector is used.
Preset
1 - 4
FX
Chorus/Delay
Delay
◊
The headphones output signal can also be routed to a mixing console or
other sound reinforcement system. To do so, connect the headphones
output with the line input on the mixing console. Use a standard cable
with 1/4" TS connectors. If hum problems occur, you could insert a
DI box, e.g. BEHRINGER ULTRA-DI DI100 or DI120.
5 - 8
9 - 12
13 - 16
Chorus
Flanger
Tab. 2.1: Effects
(19) The FX LEVEL control adjusts the mix ratio between the original and
◊
Some headphones tend to produce distortion with too high
volume level. Please turn down the volume a bit, until distortion stops.
the effect signal.
(20) The REVERB LEVEL control determines the effect intensity of the
(26) The POWER switch turns your VIRTUBE on and off. It should always be in the
additional reverb effect.
OFF position when connecting the unit to the mains.
(21) The FX LOOP MIX control (VT100FXH and VT100FX only) determines
◊
Please note: Merely switching the unit off does not mean that it is fully
disconnected from the mains. To disconnect the unit from the mains,
pull out the mains connector. Before installation, please make sure
that the mains connector has not been damaged. If you do not use the
unit for an extended period of time, please disconnect it at the mains.
the effect intensity of the external effect (see Chapter 2.2.1 FX LOOP).
(28)
(30)
(35)
(27)
(29)
(33) (31) (32) (34)
Fig. 2.2: VIRTUBE control elements (rear panel)
2.2 Rear panel
(L/R). Always use speakers with a minimum impedance of 8 Ω to ensure
maximum power output. Using the SPEAKER OUT connectors will mute the
built-in loudspeakers.
(27) The VIRTUBE is connected to the mains using a standard IEC receptacle.
A suitable power cord is included with the unit.
(28) FUSE HOLDER/VOLTAGE SELECTOR. Before connecting the unit to
the mains, ensure that the voltage setting matches your local voltage.
Blown fuses must be replaced with a fuse of the same type and rating.
On some units, the fuse holder can be switched to one of two positions,
2.2.1 FX LOOP
(31) The FX LEVEL button allows you to adapt the FX LOOP to the operating level
of an external effects device (+4 dBu/-10 dBV).
i.e. 230 V and 120 V. Please note: when operating the unit outside Europe at
120 V, a higher fuse rating is required (see Chapter 4, “Installation”).
(32) The VIRTUBE provides a serial insert path for inserting external effects
(e.g. reverb processor). To do so, connect the FX SEND jack to the input of the
effects device.
(29) This is where the fan of the unit is located.
◊
The FX SEND can also be used as a parallel output with no effects,
for example, to record a “dry” guitar signal. As long as the RETURN jack
is not in use, there will be no break in the internal signal path.
(30) The SPEAKER OUT connectors (only one on the VT100FX and VT50FX)
can be used to connect external speakers with a miminum impedance of
4 Ω. The outputs of the VT250FX deliver 50 Watts of power per channel
6
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
(33) Connect the FX RETURN jack to the output of the external effects device.
3.2 Recording set-up with effects device
The VT250FX has two jacks (L/R) because it is a stereo amplifier.
(34) Use the FOOTSWITCH jack to connect the 1" TRS plug of the footswitch
supplied with the unit. The footswitch performs a dual function: it switches
between the two channels and turns the DIGITAL FX on and off.
(35) SERIAL NUMBER.
3. Application Examples
The VIRTUBE features plenty of connectors for a wealth of applications.
Here’s a few examples of how flexible your VIRTUBE can be:
3.1 Set-up for practicing with playbacks
Footswitch
Drum Computer
HPS3000
CD Player
CD In
Fig. 3.2: Recording set-up with the VT100FX
VIRTUBE VT50FX
If you want to use your VIRTUBE in a home-recording or studio environment,
please wire it as shown in Fig. 3.2. Of course, you can still use a CD player
or drum computer in this set-up. This is not shown here to provide for a
better overview. Connect the input of the effects device to the FX SEND and
the effects output to the FX RETURN.
If you want to record your guitar signal with effects, connect the PHONES output
to your mixing console, audio sequencer or multi-track recorder.
To record a “dry” guitar signal with no effect, it is best to use the FX SEND
connector. You can use both outputs at the same time, for example, to record
signals via the FX SEND output (no effect), while monitoring them via the PHONES
output (with effect).
Electric Guitar
Fig. 3.1: VT50FX standard set-up
Instead of an external 19" effects processor, you can also use a wah-wah pedal
or other stomp box. However, please note that the FX LOOP is post-preamp,
i.e. after the distortion stages.
For practising in the rehearsal room or at home, please wire your VIRTUBE as
shown in Fig. 3.1. Connect a CD player or drum computer to the CD IN input.
If you want to practice with headphones, connect your headphones to the
PHONES jack. The built-in loudspeaker will be muted automatically. Connect the
dual footswitch supplied with the unit to the FOOTSWITCH jack on the VIRTUBE.
The CHANNEL footswitch switches between the channels. The EFFECT button
switches the effect on and off.
7
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
3.3 Live set-up with external speaker box
3.4 Wiring the VT100FXH
The VT100FXH has two SPEAKER OUT outputs for connection of one or two
external speaker cabinets. To achieve maximum power output on the VT100FXH,
both speaker outputs should be connected to speaker cabinets with a minimum
impedance of 4 Ω. Connecting headphones to the PHONES jack will automatically
mute the speaker outputs.
Fig. 3.4: VT100FXH with two speaker boxes
Fig. 3.3: Set-up comprising VT250FX and one speaker box
Fig. 3.3 shows how the LINE OUT signal is routed to a mixing console. You can
connect external guitar speaker boxes to the SPEAKER OUT outputs of the
VIRTUBE (VT100FX and VT50FX have only one output) to achieve more power
and higher volume levels on stage. When the VT250FX is used, we recommend
connecting two separate speaker cabinets for stereo applications or one stereo
cabinet (e.g. BEHRINGER ULTRASTACK BG412S).
8
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
4. Installation
Except for the headphones output and the CD IN input (1" TRS connectors),
all audio inputs and outputs on the BEHRINGER VIRTUBE are on 1" TS connectors.
Please see Chapter 5, “Specifications” for more information.
◊
Please ensure that the unit is installed and operated only by people
qualified to do so. During installation and operation the user must have
sufficient electrical contact to earth. Electrostatic discharge may affect
the operation of the unit.
Fig. 4.3: Stereo adapter cable
Fig. 4.4: Mono adapter cable
Fig. 4.1: 1" TS connector
Fig. 4.2: 1" TRS connector
9
VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
5. Specifications
VT250FX
Audio Inputs
Power Supply
Input
1" TS, RF filtered
Power consumption
Fuse
max. 180 Watts
Input impedance
FX Return
approx. 1 MΩ, unbalanced
2 x 1" TS
100 V~, 50/60 Hz
120 V~, 50/60 Hz
220 - 230 V~, 50/60 Hz
Mains connection
T 3.15 A H 250 V
Input impedance
CD In
approx. 33 kΩ, unbalanced
1" TRS
T 2.5 A H 250 V
T 1.25 A H 250 V
Standard IEC receptacle
Input impedance
approx. 5.6 kΩ, unbalanced
Audio Outputs
Dimensions / Weight
FX Send
1" TS
Dimensions (H x W x D)
520 x 670 x 275 mm
(20.5 x 26.3 x 10.8")
Output impedance
Line Out / Phones
Output level
approx. 5.6, kΩ unbalanced
1" TRS, unbalanced
max. +16 dBV / 100 Ω
Weight
22.2 kg (48.8 lbs)
Loudspeaker Outputs
Type
2 x 1"
Min. load impedance
2 x 8 Ω
Amplifier
Peak power
2 x 50 Watts / 8 Ω
Digital Signal Processing
Converter
24-bit, sigma-delta
40 kHz
Sample rate
Loudspeaker
Size
2 x 12"
Model
BUGERA Vintage Guitar Series 2 x 12G50J8
Impedance
2 x 8 Ω
Continuous power (IEC268-5)
Peak power
2 x 50 Watts
2 x 200 Watts
10 VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
VT100FX
Audio Inputs
Power Supply
Input
1" TS, RF filtered
approx. 1 MΩ, unbalanced
1" TS
Power consumption
Fuse
max. 180 Watts
Input impedance
FX Return
100 V~, 50/60 Hz
120 V~, 50/60 Hz
220 - 230 V~, 50/60 Hz
Mains connection
T 2.5 A H 250 V
Input impedance
CD In
approx. 33 kΩ, unbalanced
1" TRS
T 2.5 A H 250 V
T 1.0 A H 250 V
Input impedance
approx. 5.6 kΩ, unbalanced
Standard IEC receptacle
Audio Outputs
Dimensions / Weight
FX Send
1" TS
Dimensions (H x W x D)
550 x 580 x 275 mm
(21.6 x 22.8 x 10.9")
Output impedance
Line Out / Phones
Output level
approx. 8.2, kΩ unbalanced
1" TRS, unbalanced
max. +16 dBV / 100 Ω
Weight
20.4 kg (44.9 lbs)
Loudspeaker Outputs
Type
1"
Min. load impedance
4 Ω
Amplifier
Peak power
100 Watts / 4 Ω
Digital Signal Processing
Converter
24-bit, sigma-delta
40 kHz
Sample rate
Loudspeaker
Size
12"
Model
BUGERA Vintage Guitar Series 12G70J4
Impedance
4 Ω
Continuous power (IEC268-5)
Peak power
70 Watts
280 Watts
11 VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
VT50FX
Audio Inputs
Power Supply
Input
1" TS, RF filtered
approx. 1 MΩ, unbalanced
1" TS
Power consumption
Fuse
max. 90 Watts
Input impedance
FX Return
100 V~, 50/60 Hz
120 V~, 50/60 Hz
220 - 230 V~, 50/60 Hz
Mains connection
T 1.6 A H 250 V
Input impedance
CD In
approx. 33 kΩ, unbalanced
1" TRS
T 1.25 A H 250 V
T 630 mA H 250 V
Standard IEC receptacle
Input impedance
approx. 5.6 kΩ, unbalanced
Audio Outputs
Dimensions / Weight
FX Send
1" TS
Dimensions (H x W x D)
520 x 515 x 275 mm
(20.5 x 20.3 x 10.8")
Output impedance
Line Out / Phones
Output level
approx. 5.6, kΩ unbalanced
1" TRS, unbalanced
max. +16 dBV / 100 Ω
Weight
16.5 kg (36.3 lbs)
Loudspeaker Outputs
Type
1"
Min. load impedance
8 Ω
Amplifier
Peak power
60 Watts / 8 Ω
Digital Signal Processing
Converter
24-bit, sigma-delta
40 kHz
Sample rate
Loudspeaker
Size
12"
Model
BUGERA Vintage Guitar Series 12G50J8
Impedance
8 Ω
Continuous power (IEC268-5)
Peak power
50 Watts
200 Watts
12 VIRTUBE VT250FX/VT100FX/VT50FX/VT100FXH User Manual
VT100FXH
Audio Inputs
Power Supply
Input
1" TS, RF filtered
approx. 1 MΩ, unbalanced
1" TS
Power consumption
Fuse
max. 180 Watts
Input impedance
FX Return
100 V~, 50/60 Hz
120 V~, 50/60 Hz
220 - 230 V~, 50/60 Hz
Mains connection
T 2.5 A H 250 V
Input impedance
CD In
approx. 33 kΩ, unbalanced
1" TRS
T 2.5 A H 250 V
T 1.0 A H 250 V
Input impedance
approx. 5.6 kΩ, unbalanced
Standard IEC receptacle
Audio Outputs
Dimensions / Weight
FX Send
1" TS
Dimensions (H x W x D)
250 x 580 x 270 mm
(9.8 x 22.8 x 10.6")
Output impedance
Line Out / Phones
Output level
approx. 8.2, kΩ unbalanced
1" TRS, unbalanced
max. +16 dBV / 100 Ω
Weight
12.7 kg (27.9 lbs)
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts,
modifications may be made from time to time to existing products without prior notice. Specifications and
appearance may differ from those listed or illustrated.
Loudspeaker Outputs
Type
2 x 1"
Min. load impedance
4 Ω
Amplifier
Peak power
100 Watts / 4 Ω
Digital Signal Processing
Converter
24-bit, sigma-delta
40 kHz
Sample rate
Loudspeaker
Size
—
—
—
—
—
Model
Impedance
Continuous power (IEC268-5)
Peak power
We Hear You
|