Bacharach Carbon Monoxide Alarm True Spot User Manual

®
TrueSpot  
Smoke Test Kit  
The Bacharach True Spot Smoke Test Kit determines efficient combustion and is internationally recognized as the standard  
method for evaluating smoke density in the flue gases from distillate fuels. Too much smoke is one of the most common  
causes of excessive fuel usage and expensive service requirements. That is precisely why the smoke test is an indispensable  
part of any oil burner service job; and with the True Spot, an accurate smoke reading takes less than a minute.  
The True Spot smoke test method has long been recognized as  
ORDERING INFORMATION  
the accepted standard for oil burner smoke tests. It is used by  
Underwriters’ Laboratories in approval testing of oil burners;  
and it is the test method specified in the Installation Standards of  
the National Oil Fuel Institute by U.S. Department of Commerce,  
Testing materials (D2156-65), and German Standard DIN 51-402.  
P A R T N O .  
21-7006  
D E S C R I P T I O N  
True Spot Smoke Test Kit  
Test Pump  
21-7012  
21-0018  
Smoke Scale  
21-0040  
Lubricant  
21-0019  
Filter Paper Sheets (40 strips)*  
*Note: A spare kit containing replacement scale and  
filter paper is available; order item # 21-0020.  
COIndicatorKits  
Carbon Monoxide Indicator  
Monoxor® Indicator  
Monoxor Detector  
A quick, easy to use instrument that measures carbon  
monoxide by simply drawing an air sample through a  
chemical reagent in a glass indicator tube.  
The Monoxor Detector is also fast and simple to operate.  
An air sample is drawn through a detector tube containing  
an indicating gel; if a stain forms after one pump stroke,  
the CO concentration is 300 ppm or higher. If it appears  
after two strokes, the concentration is 100 to 300 ppm. If  
no stain appears, the concentration is less than 100 ppm.  
If carbon monoxide is present, a stain appears in the  
indicator tube; the length of the stain is measured against  
a built-in scale to determine the CO percentage or parts  
per million (ppm).  
ORDERING INFORMATION  
ITEM  
NO.  
SAMPLE PUMP  
TUBES  
TUBE  
FLUE GAS  
SAMPLING ASSEMBLY  
ITEMS  
RANGE  
SCALE  
CAPS (6)  
(Incl. Scale & Orifice A)  
(12 per carton)  
19-0240  
19-0241  
Monoxor  
Indicators  
0-0.2%  
0-0.5%  
19-0242  
19-0243  
19-0014  
19-0015  
19-5010  
19-5015  
19-0001  
19-0001  
None  
None  
19-0245  
19-0244  
Monoxor  
Gas Test Kit  
0-0.2%  
0-0.5%  
19-0242  
19-0243  
19-0014  
19-0015  
19-5010  
19-5015  
19-0001  
19-0001  
11-7045  
11-7045  
19-7021  
19-5005  
Monoxor Detector including pump, one carton of 12 indicator tubes (19-5002) and a carrying case  
Monoxor Detector Kit (19-7021), as above, plus Flue Gas Sampling Assembly (11-7056)  
20  
 

Acnodes Car Video System PMH 8064 User Manual
Acumen Heart Rate Monitor Ergo Pro User Manual
AEG Washer L 98485 FL User Manual
Agilent Technologies Tiller 5951 2826 User Manual
Airstream Smoke Alarm NTERSTATE User Manual
Alpine Car Stereo System CDE 100E User Manual
American DJ DJ Equipment Charisma User Manual
American Standard Outdoor Shower 3838Y1DT User Manual
Behringer Universal Remote DR600 User Manual
Beko Vacuum Cleaner 1180P User Manual