Combustible Gas Leak Detector
Instruction 19-9336
Rev. 0 – October 2005
12 Inch
Flexible Probe
Audible Alarm
• Instrument Ready - Slow beep. The beep
rate is about once per second with no gas
detected.
• Combustible Gas Indication - Beeps at
a rate that increases along with the gas
concentration.
• Sensitivity - Produces an increasing
frequency tone when sensitivity changes
from low to high, and produces a decreasing
frequency tone when sensitivity changes
from high to low.
• Dead Batteries - High frequency tone, fol-
lowed by the instrument turning itself OFF.
• Sensor Error - Rapidly changing high and
low frequency tones.
Visual Alarm LED
• Power ON - Rapidly flashes green during warm-
up (approximately 60 seconds).
• Power OFF - Glows red just before power OFF.
• Instrument Ready - Slowly flashes green. The
flash rate is about once per second with no gas
detected.
• Combustible Gas Indication - Flashes green at
a rate that increases with the gas concentration.
• Sensitivity Change - Color changes from red to
green.
• Low Battery - Flashes orange instead of green
when checking for gas leaks. Typically 1 hour
of operation left after LED changes to orange.
Change batteries as soon as convenient.
Battery Door
• Dead Batteries - Glows red, followed by the
instrument turning itself OFF.
Combustibles Sensor
& Sensor Cover
• Sensor Error - Flashes alternating green and red.
One Button Control
• Press once for half second to turn instrument ON.
• Press and hold for 2 seconds to turn instrument OFF.
• Double press to toggle sensitivity between high and low.
Testing For a Gas Leak
1. Turn instrument ON and allow it to warm up (approximately 60 seconds).
2. The instrument is ready to check for gas leaks after the audible alarm begins to
beep. Note that the instrument starts in its high-sensitivity mode.
3. Check for the presence of gas by positioning the tip of the flexible probe near the
area to be tested.
4. An increase in the relative concentration of gas is indicated by the visual alarm’s
LED blinking faster and the audible alarm’s beep rate increasing.
5. Once the presence of the gas has been confirmed, the instrument’s sensitivity
can be lowered by double pressing the ON/OFF button (a decreasing frequency
tone should be heard), allowing the location of the leak to be easily pinpointed.
Replacement Parts
Replacement parts can be obtained by contacting one of Bacharach’s Sales/Service
Centers listed on the back cover of this manual.
Item
Part No.
Sensor. . . . . . . . 19-0575
Sensor Cover . . 19-0576
Battery Door . . . 19-0577
Replacing the Sensor
Replace the sensor if a sensor error occurs
(Visual Alarm LED flashing green and red),
or when the instrument can no longer detect
a known source of combustible gas.
Align tab on sensor
with notch in socket
1. Turn instrument OFF.
2. Pull off sensor cover.
3. Pull out old sensor and discard.
Combustibles Sensor
Sensor Cover
4. Plug in new sensor, being sure to align
tab on sensor with notch in sensor
socket.
5. Install sensor cover.
Sales/Service Centers
United States
México
Bacharach de México
Playa Regatas No. 473 Tercer Piso
Col. Militar Marte
Delegación Iztacalco, 08830
México D.F. México
Phones: +52-555-634-7740
+52-555-634-7741
FAX:
California
7281 Garden Grove Blvd.,
Suite H
Garden Grove, CA 92841
Phone: 714-895-0050
Fax: 714-895-7950
Email: [email protected]
+52-555-634-7738
Email: [email protected]
New Jersey
7300 Industrial Park
Rte. 130, Bldg. 22
Europe
Pennsauken, NJ 08110
Phone: 856-665-6176
Fax: 856-665-6661
European Headquarters
Bacharach Instruments
Sovereign House, Queensway
Leamington Spa
Email: [email protected]
Warwickshire CV31 3JR
United Kingdom
Phone: +44-1926-338111
Fax: +44-1926-338110
Pennsylvania
621 Hunt Valley Circle
New Kensington, PA 15068
Phone: 724-334-5051
Fax: 724-334-5723
Email: [email protected]
Email: [email protected]
Sales / Service Center - Denmark
Bacharach Instruments Int'l
P.O. Box 44
Canada
Bacharach of Canada, Inc.
250 Shields Court Unit #3
Markham, Ontario L3R 9W7 Canada
Phone: 905-470-8985
39 Lindegade
DK 6070 Christiansfeld Denmark
Phone: +45-74-563171
Fax: +45-74-563178
Fax: 905-470-8963
Email: [email protected]
Email: [email protected]
Warranty
Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from
defects in material and manufacture and will conform substantially to Bacharach Inc.’s
applicable specifications. Bacharach’s liability and Buyer’s remedy under this warranty are
limited to the repair or replacement, at Bacharach’s option, of this Product or parts thereof
returned to Seller at the factory of manufacture and shown to Bacharach Inc.’s reasonable
satisfaction to have been defective; provided that written notice of the defect shall have been
given by Buyer to Bacharach Inc. within two (2) years after the date of delivery of this Product
by Bacharach, Inc. For full details concerning this warranty, contact Bacharach Inc.
621 Hunt Valley Circle, New Kensington, PA 15068
Ph: 724-334-5000 • Fax: 724-334-5001 • Toll Free: 800-736-4666
® Registered Trademark Bacharach, Inc.
Printed in U.S.A.
Copyright © 2005
|