INTRODUCTION  
Thanks for purchasing this DA1200P PC/VGA Distribution Amplifier from  
Avocent. The DA1200P VGA D.A. is designed to handle standard RGBHV  
computer type signals. Model DA1200P provides 2 outputs from a single input.  
Additional outputs can be provided by cascading additional amplifiers.  
FEATURES  
The DA1200P Distribution Amplifier has many features that enable it to  
perform in a superior manner. Among those features you will find:  
500+ MHz Bandwidth  
Supports Resolutions up to 2560x1600  
Output Range up to 300 feet  
Locking DC Power Connector  
Supports DDC, DDC2, DDC2B (Output 1 Only)  
Amplifiers may be cascaded  
Rugged Metal Housing  
Ultra Compact Size  
3
 
2.0 SPECIFICATIONS  
General  
Function  
DA1200P  
5 VDC  
2A  
Voltage Requirement  
Current Requirement  
Input Connector  
(HD-15 Female)  
1x  
2x  
Output Connectors  
(HD-15 Female)  
Maximum Resolution  
Signal Bandwidth  
2560x1600 @ 60Hz  
500+ MHz  
Weight  
400 g  
(Amplifier Only)  
14.1 oz  
Dimensions  
(H-W-D)  
43mm x160mm x 58mm  
1.7"x6.3"x2.3"  
INPUT/OUTPUT SIGNALS  
Pin # Signal  
Pin #  
Signal  
1
2
3
4
5
6
7
8
Red video  
9
NC  
Green video  
Blue video  
ID2  
10  
11  
12  
13  
14  
15  
Ground  
NC  
DDC SDA  
Horizontal Sync  
Vertical Sync  
DDC SCL  
Ground  
Analog Ground  
Analog Ground  
Analog Ground  
4
 
3.0 CHECKING PACKAGE CONTENTS  
Before attempting to use this unit, please check the packaging and make certain  
the following items are contained in the shipping carton:  
1x Distribution Amplifier  
1x Power Adapter with 5VDC Output  
1x User Manual  
Note: Please retain the original packing material should the need ever arise to  
return the unit. If you find any items are missing, contact your reseller or Avocent  
immediately. Have the Model Number, Serial Number and Invoice available for  
reference when you call.  
4.0 CONNECTING THE HARDWARE  
The front of the device has a single LED that indicates when power is applied  
and the rear panel has the power connection, input connection and two output  
connections.  
Please take a moment to familiarize yourself with the location of the various  
signal connectors and the power input connector. Make certain you connect only  
the supplied power adaptor to the device as serious damage can result by using  
improper voltages.  
DA1200P 1x2 PC/VGA Distribution Amplifier  
5
 
5.0 OPERATING THE UNIT  
5.1  
Connect the Unit as follows:  
1. Turn off power to source device (such as PC) and to all display devices  
(such as monitors).  
2. Connect the output of the source device to the amplifier’s input with the  
HD-15 cable provided.  
3. Connect the input of the display devices to the output connectors of the  
amplifier with high quality HD-15 cables, up to 300 feet in length.  
4. Plug the DC connector from the 5VDC power adapter provided into the  
amplifier. Twist the DC connector after inserting it to lock it in place.  
5. Plug the power adapter into an AC outlet.  
6. Turn on power to the source and display devices.  
Note: If you connect a DDC (Plug-and-Play) monitor to output 1 of the amplifier,  
all the other display devices must be able to support the same resolutions as the  
DDC monitor.  
5.2 CASCADING  
To display the same image on more monitors than available amplifier outputs  
permit, you may cascade additional amplifiers. Connect the input of the additional  
amplifier with an HD-15 cable to an output of the original amplifier.  
Caution - Signal degradation may occur if too many amplifiers are cascaded.  
6
 
6.0 TROUBLESHOOTING  
Problems with the DA1200P amplifier are rare. Most of the time, the problem is  
caused by the use of an incorrect cable for the signal type, to long a cable run,  
bad connectors on the cable and occasionally damaged cables. Bad grounds or  
use of different AC power sources for the DA1200P amplifier, source and/or  
display device(s) may also cause problems due to ground loops.  
After trying the above suggestions should the problem still persist, contact your  
dealer for additional suggestions before contacting Avocent. Should the dealer’s  
technical personnel be unable to assist you, contact Avocent via our support  
website: http://support.avocent.com. Create a technical support request on  
the site and our support team will respond within a short period of time.  
7.0 REGULATORY COMPLIANCE  
European ‘CE’ Mark Statement  
Emissions: EN 55022:1998+A1:2000+A2:2003 ( Information technology  
equipment. Radio disturbance characteristics. Limits and methods of  
measurement)  
EN 61000-3-2:2000+A1:2001+A2:2005 (Limits for Harmonic Currents Emissions)  
EN 61000-3-3:2000+A1:2001+A2:2005 (Limitation of voltage fluctuations and  
flicker in low-voltagte supply systems)  
Immunity: EN55024:1998+A1:2001+A2:2003 (Information technology equipment.  
Immunity characteristics. Limits and methods of measurement)  
FCC Statement  
Class A Device: This equipment has been tested and found to comply with the  
limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These  
limits are designed to provide a reasonable protection against harmful  
interference when the equipment is operated in a commercial environment. This  
equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in accordance with the Instruction Manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential  
area is likely to cause harmful interference in which case the user will be required  
to correct the interference at his own expense.  
Caution: This equipment is intended for use in the manner prescribed in the  
Instruction Manual. Any user changes or modifications not expressly approved by  
Avocent Corporation could void the user’s authority to operate the equipment.  
7
 
Connecting this equipment to external devices requires no specially shielded  
cabling for FCC compliance. The Instruction Manual shows or describes the  
proper connection of this equipment for operation that insures FCC compliance.  
Direct all inquiries regarding FCC compliance to:  
Avocent Corporation  
4991 Corporate Dr.  
Huntsville, AL 35805  
9.0 CONTACT INFORMATION  
Should you have questions or require assistance with this product in areas not  
covered by this manual, please contact Avocent at the appropriate location  
shown below:  
Avocent Corporation  
4991 Corporate Drive  
Avocent Canada 20 Mural Street,  
Unit 5  
Huntsville, Alabama 35805-6201  
USA Tel: +1 256 430 4000  
Fax: +1 256 430 4031  
Richmond Hill, Ontario L4B 1K3  
Canada Tel: +1 877 992 9239  
Fax: +1 877 524 2985 Avocent  
Avocent Asia Pacific Singapore  
Branch Office 100 Tras Street,  
#15-01 Amara Corporate Tower  
Singapore 079027  
International Ltd. Avocent House,  
Shannon Free Zone Shannon,  
County Clare, Ireland Tel: +353 61  
715 292 Fax: +353 61 471 871  
Tel: +656 227 3773  
Fax: +656 223 9155  
8
 
Where AV and IT Meet  
590-832-501A  
 

ADC Network Card Pro Patch User Manual
AEG Oven BC3000001 User Manual
Aiphoner YAW R User Manual
Allied Telesis Webcam management software layer 2+ fast ethernet switches User Manual
American Standard Hot Tub H9 User Manual
Atlona Home Theater Server AT AV0808N User Manual
Audiovox Automobile Electronics APS 55TWT User Manual
Audiovox Stereo Amplifier AXT 550 User Manual
Avital Remote Starter 4113 User Manual
Behringer Stereo Equalizer DEQ2496 User Manual