American Aldes Ventilation Hood ERV 200S User Manual

PRODUCT  
SPECIFICATIONS  
AND ENGINEERING  
ERV 200S  
INFORMATION  
-----  
ENERGY RECOVERY VENTILATOR  
For Warm Humid Climates  
SUBMITTAL DATA  
#369R  
ALDES Model ERV 200S is a  
compact Energy Recovery Ven-  
tilator designed to exhaust stale  
indoor air and supply fresh air  
from outdoors. With airflows up  
to 200 CFM, this unit can meet  
the ventilation requirements  
(0.35 Air changes per hour—  
ASHRAE 62-1999) of homes up  
to 4000 square feet. This model  
can provide significant energy  
savings on the heating and cool-  
ing costs of fresh air.  
200S  
ENERGY RECOVERY  
VENTILATOR  
PART NO.  
28 075  
nificant amount of the available  
humidity, to avoid overly-dry in-  
door conditions.)  
During the winter, an ERV also  
recovers humidity from the ex-  
haust air to partly humidify the  
supply air, reducing the need for  
ALDES’ ERV200S features a  
The ERV 200S is ideally suited  
to the mixed climates of moder-  
ate winters (temperatures above  
0°F) and humid summers. For  
colder climates, the model ERV  
200SD is recommended. This  
unit features defrost protection  
to the coldest air, shielding the  
enthalpy core from freezing con-  
ditions. This unit is also provided  
with a dehumidistat.  
plate type enthalpy core that humidification. The sensible heat  
performance is similar to an  
HRV, (Heat Recovery Ventilator)  
in that it also recovers heat from  
transfers both sensible and la-  
tent (water vapor) heat between  
the two air streams. Sensible  
heat performance is important the exhaust air to temper the  
fresh outdoor air close to room  
temperature. (During cold  
during the heating season. It is  
a measure of the temperature  
rise of the incoming fresh air and weather, both HRV’s and ERV’s  
act to lower indoor humidity by  
ventilation with drier outdoor air,  
reduces the load on the heating  
system. Total efficiency (sen-  
sible and latent) is important for but an ERV can recover a sig-  
the air conditioning season, as it  
represents the reduction of the  
cooling load.  
GENERAL FEATURES  
ERV 200S: One enthalpic core for total heat transfer (sensible and latent—  
water vapor) for year round energy savings, optimized for warm humid climates.  
No drain required.  
Low maintenance, no moving parts in the exchange core.  
Insulated 20-gauge powder coated galvanized steel cabinet.  
Five speed motor drives a centrifugal blower in each air stream. Quiet, high  
efficiency PSC motor, 120 V., 1.4 Amps, 164 Watts on high speed.  
Washable filters, one in each air stream protects the core. Easy to access and  
clean.  
During the summer, when out-  
door air is hot and humid, while  
the indoor temperature is main-  
tained at a lower temperature by  
air conditioning, the ERV rejects  
both sensible and latent heat  
(humidity) from the fresh air to  
the exhaust air, to reduce the  
ventilation load on the air condi-  
tioner by 55%.  
Complete line of accessories, controls, ducting, grilles.  
Airflow balancing kit for rent or purchase to assure balanced airflows.  
Request the HRV/ERV Design Guide to plan your installation.  
5 Year warranty on core.  
2-Year warranty on replacement parts.  
 

321 Studios Computer Monitor W2043T User Manual
Abocom Computer Drive UBT2K1H User Manual
Abocom Network Card UR3060E User Manual
Adesso Mouse AKB 210 User Manual
Aigo MP3 Player F155 User Manual
Aiwa Stereo System xr m55k User Manual
Aluratek Computer Hardware AHDDU100F User Manual
AOC Flat Panel Television A27W231 User Manual
ATI Technologies TV Cables 5000027202 User Manual
Audiovox Satellite Radio 5125 User Manual