DISTRIBUTION AMPLIFIERS
MANUAL PART NUMBER: 400-0016-004
DA1506RT
2-IN, 6-OUT VGA
DISTRIBUTION AMPLIFIER
USER’S GUIDE
DISTRIBUTION AMPLIFIERS
PRECAUTIONS / SAFETY WARNINGS
1
·
·
Do not pull any cables that are attached to the
DA1506RT.
Please read this manual carefully before using your
DA1506RT Distribution Amplifier. Keep this manual
handy for future reference. These safety
instructions are to ensure the long life of your
DA1506RT and to prevent fire and shock hazards.
Please read them carefully and heed all warnings.
If the DA1506RT is not used for an extended
period, disconnect the power cord.
1.4 CLEANING
·
·
Unplug the DA1506RT before cleaning.
Clean only with a dry cloth. Never use strong
detergents or solvents such as alcohol or
thinner. Do not use a wet cloth or water to clean
the unit. Do not open the unit to clean.
1.1 GENERAL
·
Qualified ALTINEX service personnel or its
authorized representatives must perform all
service.
1.4 FCC NOTICE
1.2. RACK-MOUNTING SAFETY GUIDELINES
·
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
·
The maximum operating ambient temperature
for this unit is 35°C.
·
Distribute units evenly inside the rack.
Hazardous conditions may be created by an
uneven weight distribution.
·
·
Connect the unit to a properly rated circuit.
Reliable grounding should be maintained.
·
This equipment has been tested and found to
comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable
protection against harmful interference when the
1.3 HANDLING
·
·
For best results, place the DA1506RT on a flat,
level surface in a dry area away from dust and
moisture.
equipment is operated in
a
commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
To prevent fire or shock, do not expose this unit
to water or moisture. Do not place the
DA1506RT in direct sunlight, near heaters or
heat-radiating appliances, or near any liquid.
Exposure to direct sunlight, smoke, or steam can
harm internal components.
·
·
Handle the DA1506RT carefully. Dropping or
jarring can damage internal components.
·
Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could void
the user’s authority to operate the equipment.
Do not place heavy objects on top of the
DA1506RT. If the DA1506RT is to be mounted
to a table or wall, use only ALTINEX-made
mounting accessories.
·
To turn off the main power, be sure to remove
the power cord. The power outlet should be
installed as near to the equipment as possible,
and should be easily accessible.
400-0016-004
2
DISTRIBUTION AMPLIFIERS
ABOUT YOUR DA1506RT
2
MECHANICAL
Material
DA1506RT
0.1” Al
DA1506RT
2-In, 6-Out Distribution Amplifier (DA)
Finish
Gray
1.75 in (44mm)
8.50 in (216mm)
4.50 in (114mm)
2.0 lb (0.91 kg)
10°C-35°C
Height (inches)
Width (inches)
Depth (inches)
Weight (pounds)
T° Operating
T° Maximum
Humidity
The DA1506RT is a 2-In, 6-Out VGA through
UXGA distribution amplifier (DA). It is designed to
connect 1 of 2 computer video sources to as many
as 6 monitors, displays, and projectors.
The rear panel of the DA1506RT has 1 computer
input and 6 outputs, while the front panel has a
single input. If both the front and rear inputs have
valid video signals, the image from the front panel
will be displayed on the 6 outputs. The rear input
can be permanently connected for normal operation
and the front panel input can be saved for special
applications. For example, a desktop PC is
permanently connected to the rear panel along with
the display devices. The image from a second
source, like a laptop, may be connected to the front
panel and temporarily override the desktop’s
image. The DA1506DT will automatically switch to
the front panel’s image.
50°C
90% non-condensing
40,000 hrs
MTBF (calculations)
Table 2. DA1506RT Mechanical
ELECTRICAL
DA1506RT
Input Video Signal
Analog Signal
1.5 Vp-p max
75 ohms
Impedance
Input Sync Signal
Horiz/Vert/Composite Sync
Sync on Green
Impedance
TTL(+/-)
-0.3V
Though primarily designed for use with displays
using 15-pin HD (VGA-type) connectors, the
DA1506RT can pass RGBHV, RGBS, and RGsB
format signals using adapter cables. The
DA1506RT is great for desktop use, but can also
be rack-mounted using optional ALTINEX
hardware.
10 kohms
Output Video Signals
Analog Signal
0 dB +/-0.5 dB
75 ohm
Impedance
Output Sync Signal
Horiz/Vert/Composite Sync
Sync on Green
Impedance
TECHNICAL SPECIFICATIONS
3
TTL(+/-)
-0.3 V
75 ohms
DC
Specifications are subject to change.
FEATURES/
DA1506RT
Coupling
DESCRIPTION
Power
GENERAL
Input Connectors
Output Connectors
15-pin HD female (2)
External adapter (included)
Total Power
9 VDC 500 mA
2.5W max.
15-pin HD female (6)
VGA through UXGA,
RGBHV, RGBS,
Table 3. DA1506RT Electrical
Compatibility
RGsB, and RsGsBs
Table 1. DA1506RT General
400-0016-004
3
DISTRIBUTION AMPLIFIERS
PRODUCT DESCRIPTION
4
FRONT VIEW
INPUT1
INPUT2
REAR VIEW
OUTPUTS 1-6
POWER
APPLICATION DIAGRAMS
DIAGRAM 1: TYPICAL SETUP
5
DA1506RT
400-0016-004
4
DISTRIBUTION AMPLIFIERS
DIAGRAM 2: INTERNAL VIEW
2-IN 6-OUT VGA-XGA DA
OUT 1
PLUG AND PLAY
PLUG AND PLAY
AUTO SWITCH
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
FRONT
BACK
15-PIN HD
15-PIN HD
SIGNAL
DETECT
POWER
POWER
9V, 0.5A
PS
400-0016-004
5
DISTRIBUTION AMPLIFIERS
DIAGRAM 3: CONNECTOR PINOUTS
INPUT CONNECTORS
OUTPUT CONNECTORS
Pin No.
PIN ASSIGNMENTS
Red
Pin No.
PIN ASSIGNMENTS
1
2
1
2
Red
Green
Green
3
Blue
3
Blue
4
Ground
4
No Connection
Ground
5
Ground
5
6
Ground
6
Ground
7
Ground
7
Ground
8
Ground
8
Ground
9
VESA +5V IN
Ground
9
+5V
10
11
12
13
14
15
10
11
12
13
14
15
Ground
Ground
No Connection
No Connection
Horizontal Sync
Vertical Sync
No Connection
VESA SDA
Horizontal Sync
Vertical Sync
VESA SCL
Table 4. The DA1506RT Input Pins
Table 5. The DA1506RT Output Pins
400-0016-004
6
DISTRIBUTION AMPLIFIERS
INSTALLING YOUR DA1506RT
6
TROUBLESHOOTING GUIDE
8
Step 1. Plug the power adapter into an AC
We have carefully tested and found no problems in
the supplied DA1506RT; however, we would like to
offer suggestions for the following:
receptacle.
Step 2. Connect the power to the unit. The power
indicator LEDs on the front and back
panels will turn on and red. This indicates
that the unit is operational.
·
·
·
Please make sure that the input amplitude of
analog signal is less than 1.5 Vp-p.
Please use the ALTINEX-supplied external
adapter (9V, 500mA).
Step 3. Connect a VGA-type cable from a
computer to Input 2 on the amplifier’s rear
panel. The LEDs will remain red, but the
images will be present on the output
connectors.
Please make sure that proper quality of cables is
used. We recommend ALTINEX-made cables
for best results.
·
If a problem arises after continuous usage at
higher voltage, higher temperature, higher
humidity, or at other extreme environmental
conditions, please make the necessary
adjustments for the DA1506RT to function safely
and properly.
Step 4. Connect a VGA-type cable from another
PC or laptop to Input 1 on the amplifier’s
front panel. If there is a signal present on
Input 1, then the LEDs will turn green
indicating that Input 1’s image is the
image present on the output connectors.
Step 5. Connect the output connectors of the
amplifier to your display devices:
monitors, projectors, LCDs, etc.
ALTINEX POLICIES
9
9.1 LIMITED WARRANTY/RETURN POLICIES
Step 6. If the image is less than perfect, check all
of the connections. Poor quality cables
may often degrade the performance of the
product. Make sure that the cables used
are coaxial cables and that all pins are in
good condition.
Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.
9.2 CONTACT INFORMATION
ALTINEX, Inc.
592 Apollo Street
OPERATION
7
Brea, CA 92821 USA
TEL: 714 990-2300
There are no adjustments necessary to operate the
unit. The DA1506RT will operate successfully as
long as cables are attached properly and other
technical specifications are followed.
TOLL FREE: 1-800-ALTINEX
WEB: www.altinex.com
E-MAIL: [email protected]
400-0016-004
7
|