SPECIFICATIONS
DRLC
EXHAUST FANS
70 CFM/4.0 SONES @ 0.10" WG. -HVI CERTIFIED
120 Volts, 1.6 amps, 60 hz.
• Grill
1
/
DRLC702 - Nickel Finish: 13 2" diameter.
1
/
DRLC703 - White Finish: 13 2" diameter.
DRLC709 - Bright Brass Finish: 13 2" diameter.
1
/
• Light Lens
Ribbed frosted glass light lens.
• Light Housing
Heavy gauge cold rolled steel c/w baked enamel finish; locks
in place on the grill via two integral tabs.
• Blower Wheel
CUL/HVI
1
/
One piece polymeric wheel, 4 2" diameter, 1" wide, with 10 fins.
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
• Motor
Single coil plug-in, two pole motor, life time lubrication, thermally
protected. Rated 120 volts, 60 hz., 1.6 amps.
• Unit Mounting
Rated Type IC for ceilings insulated to R-40. Designed to mount
in ceilings with at least 6" of clearance. The unit will mounts
• Fan Housing
3
/
1
/
directly to the joist with a rough in opening of 8 16" x 7 16". The
7
1
/
/
23 ga. Galvanized metal housing, dimensions 8" x 6 8" x 5 2",
double metal thickness mounting tabs.
housing will mount through drywall thickness up to 3 4".
/
• Ventilating Area
• Duct Collar
For bathrooms up to 70 sq. ft. for other rooms up to 85 sq. ft.
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
• Single Pack Shipping Info
1
1
1
/
/
/
Box Dim: 11 2" x 13 4" x 9 2"
DRLC702 - UPC: 0-8316227421-2
DRLC703 - UPC: 0-8316227411-3
DRLC709 - UPC: 0-8316227431-1
• Lighting
Single 100 watt maximum light capacity (bulb not included).
HVI PERFORMANCE
Static Pressure (inches of w.g.)
0
77
2300
65
0.05
74
0.1
71
0.15
68
0.2
65
2550
64
0.25
61
2600
63
0.3
57
2650
61
0.35
52
2710
60
0.4
45
2840
58
CFM
RPM
WATTS
2400
66
2450
65
2500
64
Air-King exhaust fans are tested by the Air Movement and Control Association (AMCA) in accordance with HVI test standard 916, (Air Flow Test Standard) and HVI test standard
915 (Procedure For Loudness Rating Of Residential Fan Products). The Performance results are certified and verified by the Home Ventilating Institute (HVI).
PROJECT
ARCHITECT
ENGINEER
LOCATION
CONTRACTOR
SUBMITTED BY
DATE
FAN
MODEL
IN
W.C.
OPTIONAL EQUIPMENT
& REMARKS
CFM
RPM
WATTS AMPS
SONES
QTY
NUMBER NUMBER
U.S.: 820 Lincoln Drive
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
C
US
Fax: (905) 456-1015
Specifications subject to change without notice.