Agilent E8267D PSG Vector
Signal Generator
Configuration Guide
This guide is intended to assist you with the ordering process of the PSG vector signal generators.
Step 6. Choose wideband external I/Q
Ordering number Description
Purpose
Requires
E8267D-016
Wideband external differential I/Q inputs Provides up to 2 GHz RF modulation bandwidth
for carrier frequency above 3.2 GHz and up to
260 MHz below 3.2 GHz.
Standard external I/Q inputs provide
160 MHz RF modulation bandwidth.
Step 7. Choose signal creation software for your baseband generator
Ordering number Description
Purpose
Requires
E8267D-403
E8267D-SP1
Calibrated Noise (AWGN) generation
Provides settable Eb/No and C/N
Create repeatable additive calibrated
jitter with variable rate and deviation
for tolerance measurements
E8267D-602
E8267D-602
Signal Studio for jitter injection
N7600B
N7601B
Signal Studio for 3GPP W-CDMA FDD
Create W-CDMA FDD single/multi-carrier
uplink/downlink test signals at baseband
and RF, for basestations, mobile
E8267D-602
E8267D-602
transceivers, and their components
Create cdma2000 and IS-95-A single/multi-
carrier, forward/reverse link test signals at
baseband and RF, for basestations, mobile
transceivers, and their components
Create GSM and EDGE single or multi-
carrier test signals at baseband or RF
Configure fully-coded Bluetooth packets and
and Bluetooth modulated data streams for both
basic and enhanced date rate (v2.1+EDR)
Create IEEE 802.16-2004 (WiMAX) test
signals at baseband and RF
Signal Studio for 3GPP2 CDMA
N7602B
N7606B
Signal Studio for GSM/EDGE
E8267D-602
E8267D-602
Signal Studio for Bluetooth
N7613A
Signal Studio for 802.16-2004 (WiMAX)
Signal Studio for 802.11 WLAN
E8267D-602
E8267D-602
N7613A-102
N7617B
Create arbitrary waveforms that comply with
the WLAN standards 802.11a/b/g/j/p/n
Create UWB (Ultra Wideband) signals
that comply with the proposed
N7619A
Signal Studio for multiband OFDM UWB
N6030A
N7619A-117
wideband arbitrary
waveform generator
Multi-band OFDM Alliance (MBOA)
physical layer specification
N7620A
Signal Studio for pulse building
Generates customized wide bandwidth pulse
patterns for simulation. Requires a PSA or
ESA spectrum analyzer for waveform
corrections
E8267D-016
N7620A-117 or 118 (wideband waveforms)
E8267D-UNX,
E8267D-UNW,
N6030A or N8241A
wideband arbitrary
waveform generators
E8267D-602,
N7620A
Signal Studio for pulse building
Generates customized pulse patterns for
simulation. Requires a PSA or ESA spectrum
analyzer for waveform corrections
N7620A-102
E8267D-009
E8267E-UNX
(recommended)
E8267D-016
N7621A
N7621A-117
-203
Signal Studio for multitone distortion
(wideband waveforms)
(multi tone)
Generates wide bandwidth mutiple tone
signals and applies pre-distortion techniques
to remove the nonlinear distortion of the
signal generator. Generates a simulated
broadband noise signal to facilitate NPR
measurements. Pre-distortion technigues
are used to improve flatness and increase
notch depth. Requires a PSA spectrum analyzer.
Generates mutiple tone signals and applies
pre-distortion techniques to remove the
nonlinear distortion of the signal generator.
Generates a simulated broadband noise
signal to facilitate NPR measurements.
Pre-distortion technigues are used to
E8267D-009
(recommended)
N6030A or N8241A
wideband arbitrary
waveform generator
-204
(noise power ratio)
N7621B
N7623B
Signal Studio for multitone distortion
E8267D-602
E8267D-009
E8267D-UNX
(recommended)
improve flatness and increase notch depth.
Requires a PSA spectrum analyzer.
Signal Studio for digital video
Create DVB-T/H/C/S/S2, ISDB-T, DTMB,
CMMB, J.83 Annex A/B/C and ATSC software
E8267D-602
3
Step 8. Choose special options
Special options add unique capabilities to the signal generator for specific applications.
Ordering number Description
Purpose
Requires
E8267D-H18
Wideband modulation less than 3.2 GHz
E8267D-016
E8267D-HBQ (China)
Z5623AKxx
E8267D-HCC
Add input and output of phase reference LO
Provides multi-source phase coherency
Distribution Amplifier
(recommended)
E8267D-H1G
E8267D-SP2
E8267D-HSQ 2
E8267D-H1S
Add 1 GHz external phase reference
Dynamic sequencing
Provides multi-source phase coherency for
carrier frequencies 100 kHz to 250 MHz
Provides ability to change sequences on
command in the arbitary waveform generator
Provides ability to switch between two
different external IQ inputs
E8267D-602
E8267D-602
Add second set of IQ inputs
Add 1 GHz external frequency reference input
Enables use of an external frequency
reference to improve spectral purity
Step 9. Choose instrument connector configuration and accessories
Note: Standard 20 GHz models include a 3.5 mm (m) RF output connector on the front panel.
Standard 31.8 GHz and 44 GHz models include a 2.4 mm (m) RF output connector on the front panel.
Ordering number Description
Purpose
Requires
Standard with
E8267D-520
3.5 mm (f) to 3.5 mm (f)
Adapter set is included with the purchase of
the 20 GHz models to connect to 3.5 mm (m).
Adapter set is included with the purchase of
the 31.8 GHz and 44 GHz models to connect
to 2.4 mm (m) and 2.9 mm (m).
Type-N (m) to 3.5 mm (f) adapter set is
included with the purchase of the type-N (m)
connector.
Standard with
E8267D-532 and
E8267D-544
2.4 mm (f) to 2.4 mm (f)
2.4 mm (f) to 2.9 mm (f)
Type-N (f) RF output connector
E8267D-1ED 1
E8267D-520
E8267D-1EM
Moves all front panel connectors to
the rear panel
Simplifies cable management in rack mount
environments.
E8267D-003
E8267D-004
E8267D-1CM
5063-9215
PSG digital output connectivity with N5102A
PSG digital input connectivity with N5102A
Rackmount flange kit
E8267D-602, N5102A
E8267D-602, N5102A
Provides a flange kit to mount the signal
generator into a standard EIA 19" rack.
Provides front handles for carrying the
instrument (not for rack mount).
E8267D-1CN
5063-9228
Front handle kit
E8267D-1CP
5063-9222
Rack mount flange and front handle kit
Provides front handles and a flange kit to
mount the signal generator into a standard
EIA 19” rack.
8120-8806
9211-2656
9211-7481
Master/slave interface cable
Transit case
Provides an interface cable to use two PSG's
in master/slave mode.
Provides a hard transit case to protect the
instrument during transit.
Transit case with wheels
Provides a hard transit case with wheels to
protect the instrument during transit.
Enables N5110B Baseband Studio
N5101A
N5101A-022
Baseband Studio PCI card
512 MSamples of waveform memory
E8267D-602, N5110B
Waveform memory for the Baseband Studio N5101A
PCI card
N5102A
N5110B
Baseband Studio digital signal interface module Provides digital I/Q and digital IF
inputs/outputs to/from the E4438C ESG
E8267D-602,
E8267D-003,
E8267D-004
N5101A,
and E8267D PSG vector signal generators.
Baseband Studio for waveform capture
and playback
Allows playback of I/Q waveform data
directly from a PC hard drive or the optional
512 MSa waveform memory on the N5101A
to the E4438C ESG or the E8267D PSG vector
signal generator.
E8267D-602
1.
2.
E8267D-1ED is not compatible with the 31.8 GHz or 44 GHz models.
E8267D-HSQ is not compatible with E8267D-1EH or E8267D-HCC.
4
Step 10. Choose documentation
Standard products ship with an installation guide and an electronic documentation set (CD-ROM). The CD-ROM includes: user’s guide, installation
guide, programming guide, service guide, SCPI command reference, error messages, key reference, data sheets, and additional product literature.
Ordering number
E8267D-CD1
Description
CD-ROM containing the English documentation set
Printed copy of the English documentation set (user’s guide, programming guide,
SCPI reference, key reference, and data sheets)
Printed copy of the Chinese User's Guide
E8267D-ABA
E8267D-AB2
E8267D-ABJ
E8267D-0BW
E8267D-UK6
Printed copy of the Japanese User's Guide
Printed copy of the assembly-level service guide
Commercial calibration certificate and test data
Step 11. Choose a warranty plan
Ordering number
Standard
Description
1-year return-to-Agilent warranty and service
Extended return-to-Agilent warranty and service
Extended return-to-Agilent warranty and service
3 years
5 years
Step 12. Choose a calibration plan
There is no calibration plan standard with the E8267D. For a calibration plan, specify 3 or 5 years for one of the appropriate plans
below when ordering. For more information, please visit: www.agilent.com/find/services_upfront_options.
Plan
Agilent Calibration Upfront Plan
Agilent Calibration Plus Upfront Plan
Z540 Calibration Upfront Plan
5
Upgradeable Options
Customer-installable and service center-installable upgrade kits are available for the E8267D signal generators. If an option is not
mentioned that you would like to have upgraded on your PSG, please contact your local Agilent representative about our customized
upgradeable options.
Choose customer- installable upgrade kits 1, 3
Ordering number
Upgrade description
Information required with order
E8267DK-403
E8267DK-SP1
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
Complete upgrade kit with installation guide
License key
2
E8267DK-602
E8267DK-005 5
E8267DK-009 4
E8267DK-016 7
2
2
E8267DK-1ED
E8267DK-1EH
2
2
E8267DK-UNX
E8267DK-UNW
E8267DK-007
E8267DK-UNT
E8267DK-UNU
E8267DK-015 6
Customer’s email address
Customer’s email address
Customer’s email address
License key
License key
License key
1.
2.
3.
Latest firmware is recommended for upgrades. Firmware can be found at www.agilent.com/find/upgradeassistant.
Calibration required.
Calibration and installation costs are not included in the price of upgrade installation performed at a service center. Consult your Agilent Sales
representative for details.
4.
5.
6.
7.
E8267DK-009 is only available for instrument prefix greater than or equal to 4829xxxx.
E8267DK-005 is only available for instrument prefix less than 4829xxxx.
E8267DK-015 is only available for instrument prefix less than 4722xxxx.
E8267DK-016 is only available for instrument prefix greater than or equal to 4722xxxx.
6
Web Resources
For additional product information, visit: www.agilent.com/find/psg
For information about renting, leasing or financing Agilent’s latest technology, visit: www.agilent.com/find/buyalternatives
For accessory information, visit: www.agilent.com/find/accessories
Related Agilent Literature
Agilent PSG Signal Generators
Brochure, Literature number 5989-1324EN
E8257D PSG Analog Signal Generator
Data Sheet, Literature number 5989-0698EN
E8267D PSG Vector Signal Generator
Data Sheet, Literature number 5989-0697EN
E8257D PSG Analog Signal Generator
Configuration Guide, Literature number 5989-1325EN
PSG Two-Tone and Multitone Personalities
Application Note 1410, Literature number 5988-7689EN
Signal Studio for Pulse Building
Technical Overview, Literature number 5988-8134EN
Signal Studio for Noise Power Ratio
Technical Overview, Literature number 5988-9161EN
Signal Studio for Enhanced Multitone
Technical Overview, Literature number 5988-5639EN
N5102A Baseband Studio Digital Signal Interface Module
Technical Overview, Literature number 5988-9495EN
N5110B Baseband Studio for Waveform Capture and Playback
Technical Overview, Literature number 5989-2095EN
Digital Modulation in Communications Systems — An Introduction
Application Note 1298, Literature number 5965-7160E
Free Agilent Software
Agilent software can be found by selecting the Software, Firmware & Drivers embedded link
located on each of the PSG E8267D and PSG E8257D web pages.
7
Remove all doubt
Agilent Email Updates
Our repair and calibration services
will get your equipment back to you,
performing like new, when prom-
ised. You will get full value out of
your Agilent equipment through-
out its lifetime. Your equipment
will be serviced by Agilent-trained
technicians using the latest factory
calibration procedures, automated
repair diagnostics and genuine parts.
You will always have the utmost
confidence in your measurements.
For more information on Agilent Technologies’
products, applications or services, please
contact your local Agilent office. The
complete list is available at:
Get the latest information on the
products and applications you select.
Agilent Direct
Americas
Canada
(877) 894-4414
305 269 7500
(800) 829-4444
Quickly choose and use your test
equipment solutions with confidence.
Latin America
United States
Asia Pacific
Australia
China
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
1 800 226 008
Agilent
Open
Agilent offers a wide range of ad-
ditional expert test and measure-
ment services for your equipment,
including initial start-up assistance
onsite education and training, as
well as design, system integration,
and project management.
Hong Kong
India
Agilent Open simplifies the process
of connecting and programming
test systems to help engineers
design, validate and manufacture
electronic products. Agilent offers
open connectivity for a broad range
of system-ready instruments, open
industry software, PC-standard I/O
and global support, which are
combined to more easily integrate
test system development.
Japan
Korea
Malaysia
Singapore
Taiwan
Thailand
For more information on repair and
calibration services, go to:
Europe & Middle East
Austria
Belgium
Denmark
Finland
France
01 36027 71571
32 (0) 2 404 93 40
45 70 13 15 15
358 (0) 10 855 2100
0825 010 700*
*0.125 €/minute
Germany
07031 464 6333**
**0.14 €/minute
Ireland
1890 924 204
Israel
972-3-9288-504/544
39 02 92 60 8484
31 (0) 20 547 2111
34 (91) 631 3300
0200-88 22 55
Italy
Netherlands
Spain
Sweden
Switzerland
0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries:
Revised: July 17, 2008
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2004-2008
Printed in USA, August 4, 2008
5989-1326EN
|