OPERATING  
INSTRUCTIONS  
980-312  
• LARGE-SIZED THREE-ROW DISPLAY PANEL  
ACCUSPLIT® AX602  
DIGITAL 100 MEMORY STOPWATCH  
WITH SPLIT AND LAPTIME MEASUREMENT AND  
STROKE/FREQUENCY MEASURING FUNCTIONS  
Total elapsed time, split time and lap time are displayed at the same  
time in separate rows, and they can be measured successively  
without releasing split or lap time measurement.  
• MEMORY FUNCTION  
Up to 100 measurements can be stored in memory, and they can be  
recalled after the measurement is over.  
FEATURES  
The Quartz Stopwatch is a digital  
stopwatch featuring memory and  
stroke/frequency measuring func-  
tions. In addition, the stopwatch  
is water resistant. Therefore, it is  
suitable for aquatic sports or use  
in rainy weather.  
• TIME/CALENDAR DISPLAY  
Year, month, date, hour, minutes, and seconds can be displayed while  
the stopwatch is not in use.  
• BATTERY LIFE INDICATOR  
Lithium battery CR2032 or equivalent is used.  
• ACCUSPLIT “X” CASE  
Exclusive professional case with no-fail buttons.  
• STOPWATCH  
The stopwatch can measure up  
to 10 hours in 1/100 seconds.  
• SPLIT TIME/LAP TIME  
MEASUREMENT  
Up to 100 split times and lap  
times can be measured.  
2
3
 
2. ACCUMULATED ELAPSED TIME MEASUREMENT  
START STOP  
• “Split time” refers to an elapsed time required to cover a distance from  
the start to a given point.  
• “Lap time” refers to an elapsed time required to cover a given section  
of the whole distance.  
RESTART  
A
A
Lap time  
Start  
Split time  
1. STANDARD MEASUREMENT  
RESET  
STOP  
START  
STOP  
RESET  
B
A
A
A
B
Restart and stop  
of the stopwatch  
can be repeated  
by pressing “A”.  
Hour  
Seconds  
Minutes  
1/100 seconds  
8
9
SPLIT-LAP 2  
3. SPLIT TIME/LAP TIME MEASUREMENT  
4. HOW TO USE THE MEMORY FUNCTION  
B
The stopwatch can store up to 100 split times, 100 lap times and total elapsed  
time. They are automatically entered into the memory.  
• With each press of “C, the time stored is recalled. The time can be  
recalled successively by keeping the button pressed.  
START  
SPLIT-LAP 1  
Split time  
Lap time  
A
B
C
C
C
Accumulated  
elapsed time  
Split/lap number  
The split/lap time can  
be measured repeated  
by pressing “B.  
RESET  
STOP  
“RECALL” more  
C
SPLIT-LAP 8  
B
A
B
A
B
Finish time  
Reset to “00”  
Finish time  
Note: When the number of stored measurements  
• To stop the recall of the stored data, press “A, B, or “D. The  
exceeds 90, flashing “FULL” appears, and when  
it exceeds 100, a warning sound starts beeping.  
measurements when the stopwatch was stopped will be shown.  
Then, press “B” to reset the digits to “00.  
10  
11  
 
STOKE/FREQUENCY MEASURING  
• The time stored in the memory can be recalled even while the stopwatch  
is measuring.  
Press “D” to show the STROKE/FREQUENCY MEASURING display.  
Start the measurement by pressing “A” and stop the measurement by pressing  
“A” after the third stroke was made. The number of strokes per minute will be  
displayed.  
With each press of “C”  
When the stopwatch is stopped  
When the stopwatch is measuring  
Split time and lap time are recalled  
starting with the first ones.  
Start  
Stop  
Measuring  
Reset  
The times are recalled starting with  
the last ones.  
B
A
A
B
• To measure the lap time and split time while the stored data are being  
recalled operate the buttons as follows.  
A
B
Press “B” to measure new lap time and split time.  
Press “A” to stop the measurement.  
Start  
Stop  
Press “D” to return to the measurement mode.  
STROKE/  
FREQUENCY  
MEASURING  
mode  
The number  
of strokes  
per minute  
(23.2)  
Notes:  
1. Even if the digits are reset to “00”, stored times are not erased and can be  
recalled by pressing “C” unless new measurement is started.  
2. If the stopwatch is left untouched with the recalled times shown, the display  
will automatically return the STOPWATCH display in 1 to 20 minutes.  
12  
13  
Notes:  
REGISTER NOW Please return  
your AX602 Registration to the  
Repair Center address in the  
warranty, and we will let you  
know about future products.  
Email (preferred)  
User  
1. During 1 second after the measurement has been started by pressing “A,  
flashing “180.0” is displayed. If the measurement is stopped by pressing  
“A” during this period, “Err” will appear. If the measurement is not stopped  
by pressing “A” after more than 18 seconds have elapsed, “Err” will  
automatically appear. Therefore, note that measurable number of strokes  
per minute is between 10 and 180.  
NO-PROOF-OF-PURCHASE LIMITEDWARRANTY  
See label on back of unit for details, or check  
Error  
2. If “B” is pressed while the measurement is stopped or “Err” is shown, the  
digits will be reset “0.0. Even if the digits are not reset to “0.0” with the  
measurement stopped or “Err” shown on the display, the measurement  
can be started by pressing “A.  
14  
15  
 

Acer Laptop Docking Station EasyPort III User Manual
Acer Tablet B1 720 L864 User Manual
ADIC Time Clock 6 00028 01 Rev A User Manual
Advantech Computer Hardware PCM 9588 User Manual
AEG Power Supply 6000BP User Manual
AllerAir Air Cleaner 5000 D User Manual
Alpine GPS Receiver PMD B200 User Manual
Alto Shaam Oven 10 10ESiN User Manual
Audiovox Camcorder DC500 User Manual
Axor Indoor Furnishings 40352000 User Manual