AMX TV Cables CB TP12 User Manual

Installation Guide  
CB-TP12  
Rough-In Box for 12" Wall/Flush Mount Touch Panels  
Overview  
Installing a 12" NXD panel within a Rough-In Box  
The procedures outlined in this document apply to the 1200V-and 1200VG-  
Series of touch panels.  
The Rough-In Box must be mounted prior to continuing this section. Verify that  
all necessary cables have been threaded through the knockouts on the Rough-In  
Box and the connections have been tested prior to installation of the touch panel.  
Wall Mount panels (NXDs) are contained within a metallic outer housing (back  
box). This back box is not removed when installing the NXD into a CB-TP12  
Rough-In Box. The back box is only removed to gain access for the replacement  
of the Compact Flash component or upgrade to the VESA housing.  
1.  
Remove the magnetic faceplate/bezel (A in FIG. 2) from the main NXD unit  
(B in FIG. 2) by gripping the faceplate and pulling with gentle outward force.  
Verify the incoming RJ-45, Ethernet, USB, and any other audio/video  
cables have been properly threaded through the wiring knockouts (from  
their terminal locations) on the Rough-In Box. Leave enough slack in the  
wiring to accommodate any re-positioning of the panel.  
2.  
The CB-TP12 Rough-In Boxes are optional metallic boxes that are secured onto  
stud beams prior to the installation of a solid surface. Installation procedures and  
configurations can vary.  
3.  
Connect all data and power wiring connectors to their corresponding loca-  
tions along the side of the (un-powered) NXD touch panel.  
Verify the terminal end of the power cable is not connected to a power  
supply before plugging in the 2-pin power connector.  
Specifications  
CB-TP12 (FG031-10) Specifications  
Dimensions (HWD) • 11.52" x 11.60" x 3.50"  
• 29.27 cm x 29.47 cm x 8.89 cm  
The USB connectors can be from either a USB extension cable, or  
a wireless USB RF transmitter.  
Included  
Accessories  
Rough-In Box Installation Kit (SA2001-02) (one kit per CB)  
• 4 Phillips pan-head (#4-40 x 0.375 Black) screws (80-0115)  
• 4 Phillips pan-head (#4-40 x 0.625 Black) screws (80-0118)  
Note: Don’t disconnect the connectors from the touch panel. The unit must be  
installed with the attached connectors before being inserted into the Rough-In  
Box.  
Certifications  
• cTUVus Listed  
4.  
Test the incoming wiring by connecting the panel connections to their  
terminal locations and applying power. Verify the panel is receiving power  
and functioning properly to prevent repetition of the installation.  
Disconnect the terminal end of the power cable from the connected PSN  
power supply.  
WARNING: INSTALLER, LEAVE A GAP BETWEEN THE STUD AND ROUGH-  
IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK.  
This gap allows the installation of the drywall/sheetrock after the Rough-In Box  
has been installed.  
5.  
6.  
7.  
8.  
Carefully slide the main NXD unit (B in FIG. 2) into the Rough-In Box, so  
the Mounting Tab lies flush against the Rough-In Box (C in FIG. 2).  
Insert and secure the four securing #4-40 Mounting Screws into their  
corresponding holes located along the sides of the NXD.  
Note: The most important thing to remember when mounting this Rough-In Box  
is that the mounting tabs must be mounted flush against the outside of the  
sheetrock.  
Replace the magnet faceplate (A in FIG. 2) back onto the main NXD unit.  
Make sure to align the Microphone, Light, and PIR Motion sensor locations  
to their respective openings on the front bezel/faceplate.  
Pre-Wall Installation of the CB-TP12 Rough-In Box  
1.  
Fasten the CB-TP12 to a stud through the stud fastening holes, located on  
the inside of the Rough-In Box (FIG. 1), by using either nails or screws.  
Remove any necessary wiring knockouts from the Rough-In Box (C in  
FIG. 2) where the necessary cables are threaded through for connection to  
the touch panel.  
9.  
Connect the terminal RJ-45, Ethernet, and any optional audio/video wiring  
to their respective locations (outside the Rough-In Box) on either the AVB  
breakout box, Ethernet port, or NetLinx Master.  
2.  
10. Reconnect the terminal power connector on the PSN and apply power  
3.  
4.  
Thread the incoming RJ-45, Ethernet, and any other audio/video wiring  
through the knockouts.  
Install the drywall/sheetrock before inserting the main NXD unit into the  
CB-TP12.  
Stud  
Knockouts should be located on the left-side of the  
Rough-In Box, alongside the connectors  
Drywall/  
sheetrock  
CB-TP12 Rough-In Box  
Stud fastening holes  
Use the four #4-40  
Mounting Screws to  
secure the NXD to the  
Rough-In Box at these  
locations  
Mounting tabs  
for NXD panel should  
be flush with the outside of the sheetrock  
FIG. 1 Screw locations for Rough-In Box attachment in a pre-wall installation  
 

ABC Office Paper Shredder 20390 User Manual
Acnodes Computer Hardware RMC 7185 User Manual
ADTRAN Telephone 604 User Manual
Advantech Car Video System CPC 2520 User Manual
Alto Shaam Oven 1000 SK I User Manual
American Standard Indoor Furnishings T555430 User Manual
American Standard Outdoor Shower T03850X User Manual
Asus Cell Phone V66 User Manual
Axis Communications Webcam AXIS M7014 User Manual
Baby Jogger Stroller ASTM F833 07A User Manual