Linear 1092 07 User Manual

INSTALLATION INSTRUCTIONS  
Power Adaptor Kit  
Model 1092-07  
The Model 1092 Power Adaptor Kit permits the connection of a three-tab radio  
control receiver to a garage door operator which does not conform to the three-  
terminal standard adopted by DORCMA. The operator may have only two terminals  
or the numbering sequence may be different.  
TO CONNECT A THREE-TAB RECEIVER:  
1. The push on receptacle on each wire is connected to the straight tab of the  
receiver terminals.  
2. Each terminal is marked on the data label on the back of the receiver.  
Connect the wires to the receiver terminals as follows:  
a. Receptacle with two wires (power transformer and  
push button wire) to terminal mark “1” or “24V”.  
b. Receptacle with second push button wire to terminal  
marked “2” or “relay”.  
c. Receptacle with remaining transformer wire to  
terminal marked “3” or “radio power”.  
3. Connect the two spade lugs to the wall button terminals on the operator  
(terminals 1 and 2 on a three terminal operator). Plug the transformer into a 115  
VAC outlet.  
LINEAR CORPORATION  
2055 Corte Del Nogal  
Carlsbad, California 92009  
Copyright © 1999 Linear Corporation  
216720 A  