Fujitsu Computer Drive MPC3032AT User Manual

MPC3032AT  
MPC3043AT  
MPC3064AT  
MPC3084AT  
MPC3096AT  
MPC3102AT  
DISK DRIVES  
MAINTENANCE MANUAL  
C141-F029-02EN  
This page is intentinally left blank.  
PREFACE  
This manual describes the MPC3032AT, MPC3043AT, MPC3064AT, MPC3084AT, MPC3096AT  
and MPC3102AT a 3.5-inch hard disk drive with a BUILT-IN controller that is compatible with the  
IBM PC-AT interface.  
This manual explains, in detail, how to maintenance the disk drives.  
This manual assumes that users have a basic knowledge of hard disk drives and their application in  
computer systems.  
This manual consists of the following two chapters:  
Chapter 1  
Chapter 2  
MAINTENANCE AND DIAGNOSTIC  
REMOVAL AND REPLACEMENT PROCEDURE  
In this manual, disk drives may be referred to as drives, or devices.  
IBM PC-AT is a registered trademark of IBM (International Business Machines Corporation) of the  
United States of America.  
C141-F029-02EN  
iii  
Conventions for Alert Messages  
This manual uses the following conventions to show the alert messages. An alert message consists of  
an alert signal and alert statements. The alert signal consists of an alert symbol and a signal word or  
just a signal word.  
The following are the alert signals and their meanings:  
This indicates a hazarous situation likely to result in serious personal  
injury if the user does not perform the procedure correctly.  
This indicates a hazarous situation could result in personal injury if the  
user does not perform the porocedure correctly.  
This indicates a hazarous situation could result in minor or moderate  
personal injury if the user does not perform the procedure correctly.  
This alert signal also indicates that damages to the product or other  
property, may occur if the user oes not perform the procedure correctly.  
This indicates information that could help the user use the product more  
efficiently.  
In the text, the alert signal is centered, followed below by the indented message. A wider line space  
precedes and follows the alert message to show where the alert message begins and ends. The  
following is an example:  
(Example)  
The DE is completely sealed. Do not open the DE in the field.  
The main alert messages in the text are also listed in the “Important Alert Items.”  
iv  
C141-F029-01EN  
LIABILITY EXCEPTION  
"Disk drive defects" refers to defects that involve adjustment, repair, or replacement.  
Fujitsu is not liable for any other disk drive defects, such as those caused by user misoperation or  
mishandling, inappropriate operating environments, defects in the power supply or cable, problems of  
the host system, or other causes outside the disk drive.  
C141-F029-01EN  
v
This page is intentinally left blank.  
Important Alert Items  
Important Alert Messages  
The important alert messages in this manual are as follows:  
A hazarous situation could result in minor or moderate personal injury if  
the user does not perform the procedure correctly. This alert signal also  
indicates that damages to the produt or other property, may occur if the  
user does not perform the procedure correctly.  
Task  
Maintenance  
Alert message  
Page  
1. Don't install or remove a PCA or connect or disconnect a  
cable or connector plug when the drive is powered. This  
may give you an electric shock.  
1-1  
2. Don't touch the Disk Drive during operation. This may  
cause injuries.  
3. Avoid dangerous detergents when cleaning the disk drive.  
1. Before touching a PCA, perform the human body grounding  
to discharge static electricity from your body. This will  
prevent electrical damage to the PCA.  
1-2  
2. Don't install or remove a PCA or connect or disconnect a  
cable or connector plug when the drive is powered. This  
will prevent electrical damage to the disk drive.  
3. Operating the disk drive with one or more PCA missing will  
be unpredictable. Only power the drive with all boards  
installed.  
4. Avoid any detergent which may cause short circuits when  
cleaning assemblies.  
5. Keep all vents open opened and unblocked.  
6. A ribbon type cable has one line marked. Ensure that this  
line is always connected to pin 1 of the cable connector.  
The DE is completely sealed. Do not open the DE in the field.  
1-2  
1-3  
When asking for repair, save all data stored in the disk drive  
beforehand. Fujitsu Limited is not responsible for any loss of  
data during service and repair.  
The disk enclosure must never to opened in the field. Opening  
the disk enclosure may cause irreparable damage.  
1-12  
C141-F029-01EN  
vii  
Task  
Alert message  
Page  
1. Perform any removal after the system power is completely  
disconnected. The cable must not be disconnected and the  
screws that attach the drive must not be removed with the  
power ON.  
2-2  
2. Do not move the drive until it comes to a complete stop  
(about 30 s after the power is turned OFF).  
3. Perform the human body grounding to discharge any static  
electricity from your body.  
viii  
C141-F029-01EN  
CONTENTS  
page  
CHAPTER 1 MAINTENANCE AND DIAGNOSIS ........................................................... 1 - 1  
1.1 Maintenance ................................................................................................................... 1 - 1  
1.1.1 Rules for maintenance .................................................................................................... 1 - 1  
1.1.2 Maintenance requirements.............................................................................................. 1 - 2  
1.1.3 Maintenance levels ......................................................................................................... 1 - 5  
1.1.4 Disk drive revision number ............................................................................................ 1 - 5  
1.1.5 Tools and test equipment................................................................................................ 1 - 7  
1.1.6 Self-diagnostics .............................................................................................................. 1 - 7  
1.1.7 Test................................................................................................................................. 1 - 7  
1.2  
Operation Confirmation.................................................................................................. 1 - 9  
1.2.1 Operation test ................................................................................................................. 1 - 9  
1.2.2 Diagnostic test ................................................................................................................ 1 - 10  
1.3  
Troubleshooting Procedure............................................................................................. 1 - 10  
1.3.1 Troubleshooting procedure............................................................................................. 1 - 10  
1.3.2 Troubleshooting disk drive replaced in field .................................................................. 1 - 10  
1.3.3 Troubleshooting at factory.............................................................................................. 1 - 12  
CHAPTER 2 REMOVAL AND REPLACEMENT PROCEDURE.................................. 2 - 1  
2.1  
2.2  
Spare Parts...................................................................................................................... 2 - 1  
Disk Drive Removal....................................................................................................... 2 - 2  
C141-F029-01EN  
ix  
This page is intentionally left blank.  
FIGURES  
page  
1.1  
1.2  
1.3  
Disk drive revision number label.................................................................................... 1 - 5  
Display of disk drive revision number............................................................................ 1 - 6  
Test flowchart................................................................................................................. 1 - 8  
TABLES  
page  
Status register contents ................................................................................................... 1 - 9  
Disposition for error register contents ............................................................................ 1 - 9  
System level and field troubleshooting........................................................................... 1 - 11  
Model and parts numbers ............................................................................................... 2 - 2  
1.1  
1.2  
1.3  
2.1  
C141-F029-01EN  
xi  
This page is intentinally left blank.  
CHAPTER 1  
MAINTENANCE AND DIAGNOSIS  
1.1  
1.2  
1.3  
Maintenance  
Operation Confirmation  
Troubleshooting Procedure  
This chapter describes the maintenance, diagnosis, operation check, and troubleshooting of the disk  
drive. The following are explained:  
·
·
·
·
·
·
Rules for regular maintenance and troubleshooting  
Display of maintenance level (field and factory)  
Display of Drive revision and revision change in the field  
Tools and test devices needed for each maintenance level  
Standard testing for each maintenance level  
Recommended procedure for troubleshooting and fault diagnosis  
1.1  
Maintenance  
1.1.1  
Rules for maintenance  
Obey the following rules to prevent injury during troubleshooting or maintenance.  
1. Don't install or remove a PCA or connect or disconnect a cable  
or connector plug when the drive is powered. This may give  
you an electric shock.  
2. Don't touch the Disk Drive during operation. This may cause  
injuries.  
3. Avoid dangerous detergents when cleaning the disk drive.  
Obey the following rules for troubleshooting and maintenance to avoid damaging the disk  
drive.  
C141-F029-01EN  
1 - 1  
1. Before touching a PCA, perform the human body grounding to  
discharge static electricity from your body. This will prevent  
electrical damage to the PCA.  
2. Don't install or remove a PCA or connect or disconnect a cable  
or connector plug when the drive is powered. This will prevent  
electrical damage to the disk drive.  
3. Operating the disk drive with one or more PCA missing will be  
unpredictable. Only power the drive with all boards installed.  
4. Avoid any detergent which may cause short circuits when  
cleaning assemblies.  
5. Keep all vents open opened and unblocked.  
6. A ribbon type cable has one line marked. Ensure that this line  
is always connected to pin 1 of the cable connector.  
1.1.2  
Maintenance requirements  
(1)  
Preventive maintenance  
The disk drive needs no preventive maintenance, not even the air filter needs to be changed.  
The DE is completely sealed. Do not open the DE in the field.  
(2)  
Service life  
In situations where management and handling are correct, the life of the disk drive is five years  
when the DE surface temperature is less than 48°C. When the DE surface temperature exceeds  
48°C, the life is five years or 20,000 hours of operation, whichever occurs first. For the  
measurement point of the DE surface temperature, refer to Section 3.2 in Product Manual.  
1 - 2  
C141-F029-01EN  
(3)  
(4)  
Exchangeable parts in field  
The PCA and the DE cannot be replaced separately in the field. Replace the whole disk drive.  
Service system and repair  
Fujitsu Limited has a disk drive service system and repair facility. When making a request for  
repair or parts replacement, you should provide related information usually including:  
a) Model name of disk drive, part number (P/N), disk drive revision number, manufacture  
serial number (S/N), and date of manufacture of the disk drive  
b) Circumstances when the fault occurred  
·
·
·
Date of trouble occurred  
System configuration  
Environmental conditions (including temperature, humidity, and voltage)  
c) Fault history of the drive  
d) Details of the fault  
·
·
·
·
·
Description of the fault  
Issued command and specified parameters  
Status (Status/Error register)  
Interval of the fault  
Other information for fault diagnosis  
When asking for repair, save all data stored in the disk drive  
beforehand. Fujitsu Limited is not responsible for any loss of data  
during service and repair.  
(5)  
Notes on handling  
a. General notes  
a) Vibrations and shocks more severe than allowed will cause fatal damage to the device  
so be very careful. Be especially careful when unpacking the device.  
b) Do not leave the device in a dusty environment.  
c) Because the device uses static sensitive CMOS semiconductors take the following  
precautions, be careful of the handling on the following points after the device is  
unpacked.  
·
Use an antistatic mat where the device is handled and it is recommended that the  
body of the handler be grounded.  
C141-F029-01EN  
1 - 3  
·
Hold by the DE section, do not directly touch the PCA unit unnecessarily.  
b. Unpacking  
a) Use a flat workplace, find which side of the pack is up and be careful not to have the  
wrong side facing upwards. Do not place the device directly on a hard table, place it  
on something soft such as a rubber mat.  
b) Be careful not to apply any excessive force to the packed device when removing the  
shock absorbing material.  
c) When taking the device out of the antistatic bag, be especially careful not to apply any  
excessive force to the PCA or to the interface connector section.  
d) Never ever remove the DE seal label and screws and the DE cover.  
c. Installation  
a) When the power is ON, do not change the switch setting, or connecting, or  
disconnecting connectors.  
b) Do not move the device or disconnect connectors with the power ON or until the disk  
drive unit comes to a complete stop after the power is turned OFF (about 30 seconds).  
d. Packaging  
a) Place the device in an antistatic vinyl bag along with a desiccant (silica gel).  
b) It is recommended that you use the shock absorption cushion material and packaging  
that contained the device when it was delivered by Fujitsu.  
If the same packaging material cannot be used, use a shock absorbent box that will  
transmit shocks directly to the device. When using this type of box, adequately  
protect the PCA surface and interface connector section.  
c) Place a label showing which side is up and clearly stating the notes on handling on  
the outside of the packaging.  
e. Delivery  
a) As a rule, deliver as it is packaged and keep the up side up.  
b) If delivering a single drive after it is unpacked, take it only a short distance. Also, use  
shock absorbent material to protect it against shock and vibration. Deliver an  
unpacked device in either of the allowable packed positions. Refer to Section 3.2 in  
Product Manual.  
1 - 4  
C141-F029-01EN  
f. Storage  
a) Store in dampproof packaging.  
b) Take care that the environmental requirements satisfy the non-operating  
environmental specifications described in Section 1.4 in Product Manual.  
c) To prevent condensation, do not subject the device to sudden changes of temperature.  
1.1.3  
Maintenance levels  
Because of its compact size and special repair requirements, it is recommended that the whole  
disk drive be replaced. This section describes maintenance on two levels.  
(1)  
Field maintenance (disk drive replacement)  
·
·
·
Replacement at the user site.  
Disk drive replacement requires ordinary tools.  
Usually, the user, retailer, seller, or OEM trader will replace the drive.  
(2)  
Factory maintenance (parts replacement)  
·
·
Only Fujitsu can perform maintenance at this level.  
This includes maintenance training and assisting other OEM traders. The OEM trader  
usually assists the retailer and seller.  
·
Use the factory level tools and test equipment. This includes recommended spare parts  
and repairing or replacing various parts.  
1.1.4  
Disk drive revision number  
The disk drive revision number is a single alphabetic character followed by a single  
alphanumeric character. It is stuck on the DE and marked on the revision number label.  
Figure 1.1 shows the disk drive revision number label format.  
Disk drive revision number  
Firmware code/revision  
Figure 1.1 Disk drive revision number label  
C141-F029-01EN  
1 - 5  
(1)  
(2)  
Revision number marking at delivery  
The machine revision number is indicated by crossing out up to the relevant number in the  
relevant alphabetic character row using = marks (see Figure 1.2).  
Revision number change in the field  
When a part is replaced in the field or other modifications are made, the machine revision  
number may need to be changed. The level is indicated by crossing out the relevant number in  
the relevant alphabetic character row using marks (see Figure 1.2).  
(3)  
Firmware code and revision  
First 2-digit indicates a firmware code and rest 2-digit indicates its revision.  
Note:  
For a change of revision number after delivery, Fujitsu issues a "Change Request/Notice"  
and the disk drive revision number after the change. When a change is made at the user  
site, the revision number level should be changed as described above.  
Revision number mark when delivered  
A2 Revision  
Revision number change in the field  
A3 Revision  
Figure 1.2 Display of disk drive revision number  
1 - 6  
C141-F029-01EN  
1.1.5  
1.1.6  
Tools and test equipment  
At the field maintenance level, only ordinary hand tools are required for troubleshooting and  
repairing the disk drive. Special tools and test equipment is not required.  
Factory level tools and test equipment are beyond the scope of this manual.  
Self-diagnostics  
The disk drive has the following self-diagnostics. These self-diagnostics allow normal basic  
operation of an isolated disk drive can be checked.  
·
·
Initial self-diagnostics  
Offline self-diagnostics (EXECUTE DRIVE DIAGNOSTIC [DIAGNOSTIC] command)  
1.1.7  
Test  
The disk drive test can be divided into the following three levels.  
·
·
Operating test (See Subsection 1.2.1 on Operating test.)  
Diagnostic test (See Subsection 1.2.2 on Diagnostic test.)  
Figure 1.3 shows the relationship between the test level and troubleshooting.  
Tables 1.1 and 1.2 show the check contents.  
C141-F029-01EN  
1 - 7  
Start  
Yes  
Check the host system  
(Table 1.1)  
Operation test with the  
host computer or test  
equipment  
Analyze the system  
related failure  
No  
System normal?  
Yes  
Disk drive  
replacement or repair  
No  
Test acceptable?  
Yes  
No  
Continue with the  
operation  
Disk drive normal?  
Yes  
Diagnostic test with  
the host computer or test  
equipment  
No  
Test acceptable?  
Yes  
Test using voltage or  
temperature stress  
No  
Disk drive failure  
analysis (Table 1.1)  
Test acceptable?  
Yes  
No failure  
Figure 1.3 Test flowchart  
1 - 8  
C141-F029-01EN  
Table 1.1 Status register contents  
Status bit  
BIT0 = 1  
BIT1, 2  
Contents  
Shown in Table 1.2  
Normal  
BIT3 = 1  
BIT4 = 1  
BIT5 = 1  
BIT6 = 0  
BIT7 = 1  
(1) Check whether vibration is transmitted because of the way the disk drive is mounted.  
(2) Check the power, cable, and connector.  
(3) If it is concluded that the disk drive is the cause, replace the disk drive.  
Table 1.2 Disposition for error register contents  
Error bit  
BIT0, 4  
Method of disposition  
(1) If an error occurs in a specific sector, treat that sector as a bad sector or replaced the  
sector.  
(2) If errors occur frequently, check for problems with the power supply and the  
mounting of the disk drive (disconnect the mainframe, power supply, and disk drive).  
(3) If it is concluded that the disk drive is the cause, replace the disk drive.  
BIT1, 2  
(1) Check the status of the host, cable and drive.  
(2) If it is concluded that the drive is the cause, replace the drive.  
BIT6  
BIT7  
Process the bad sector.  
(1) Check the status of the host, cable, power connector and drive.  
(2) If it is concluded that the drive is the cause, replace the drive.  
1.2  
Operation Confirmation  
Operation test  
1.2.1  
When the host computer is processing data, the disk drive monitors disk drive operation errors  
including data, command, and seek errors. The host is notified of the error that the disk drive  
detected and the user is notified of its result.  
The user may notice intermittent and indefinite failures such as overlong execution time,  
abnormal noise, abnormal odor, or failures in particular processes.  
The failure reported in the operation test will need further investigation. To ascertain the cause  
of the disk drive failure reported, the disk drive can be replaced. Failures in the operation test  
are often not caused by the host system. For example, not having enough power supply  
reserve, a loose cable connection, no timing and mechanical reserves, or relationship with  
other systems.  
In normal operation, the disk drive itself or the host determines the processing (return or halt)  
following the detected failure state.  
C141-F029-01EN  
1 - 9  
To troubleshoot the failure reported in the test at this level, accurately reproduce the condition  
that caused the failure. Then, by replacing the disk drive, try to separate the fault from the  
other sections of the disk drive host system.  
1.2.2  
Diagnostic test  
The diagnostic test is used to separate a confirmed disk drive failure to a disk drive  
subassembly or to check the disk drive performance. A test of this level usually includes a  
specific disk drive function or concentrated execution of a group of functions. The test is  
usually performed by a factory engineer and not where the failure was reported. The disk  
drive is tested using another host computer or test equipment.  
To troubleshoot the disk drive failure in the diagnostic test, the engineer will reproduce the  
failure condition. The engineer then isolates the failure to a subassembly or part of the disk  
drive.  
The procedures used in a test of this level great depend on the test equipment used. It is  
beyond the range of this manual.  
1.3  
Troubleshooting Procedure  
Troubleshooting procedure  
1.3.1  
This section describes the troubleshooting procedures for a disk drive failure at field  
maintenance level described in Subsection 1.1.3.  
In this section, troubleshooting is made to isolate the reported failure to the disk drive or a host  
system. Usually, troubleshooting is necessary only when a cause of failure is uncertain or  
unknown. When a cause of failure is clear (for example, abnormal sound in the DE or burnt  
parts on the PCA), a level of troubleshooting is low.  
1.3.2  
Troubleshooting disk drive replaced in field  
It is recommended that the whole drive be replaced in maintenance of this level. If replacing  
the drive corrects the fault, return the old drive to the factory for testing and repair. If the new  
drive shows the same fault as the one that was removed, the failure is elsewhere in the system.  
System level troubleshooting, shown in Table 1.3, is performed at the user site to isolate the  
reported failure to the disk drive or system.  
1 - 10  
C141-F029-01EN  
Table 1.3 System level and field troubleshooting  
Check to be made  
DC power cable  
Recommended work  
Confirm that the power cable is properly connected at the disk drive and  
power supply section.  
DC power voltage  
level  
Confirm that the DC power voltage is within ±5% (+5 VDC) or ±8% (+12  
VDC) of the standard value.  
When measured at pins 3 and 4 of the power supply connector, the +5 VDC  
must be 4.75 to 5.25 VDC.  
When measured at pins 1 and 2 of the disk drive power supply connector the  
+12 VDC must be 11.04 to 12.96 VDC.  
DC power ripple  
noise  
Check that the maximum ripple at +5 and +12 VDC power is less than  
100 mV peak to peak and 200 mV peak to peak respectively.  
Interface cable  
connection  
Confirm that the AT interface cable is properly connected at the disk drive  
and control unit.  
Switch setting  
Confirm that the switch on the switch on the disk drive control PCA is set  
for normal operation with the host computer. Refer to Section 3.4 in Product  
Manual for switching setting.  
System cable  
Confirm that all cable connections throughout the system correctly  
connected.  
System diagnostic  
test  
To further isolate the failure, if it can be done, execute the system level  
diagnostic routine described in the host computer manual.  
Intermittent or  
indefinite error  
Check the AC voltage level at the power supply section and recheck the DC  
voltage level at the disk drive power supply connector.  
If the AC voltage level is abnormal, or if there is a lot of electrical noise,  
notify the user.  
If the DC voltage level is unstable, replace the power supply section.  
If possible, replace the disk drive. If the fault remains, the disk drive is not  
the case. For suggestions to isolate the failure further, refer to the hardware  
and software manuals provided with the system.  
C141-F029-01EN  
1 - 11  
1.3.3  
Troubleshooting at factory  
When the trouble is recovered by replacing the drive at field (Subsection 1.3.2), troubleshoot  
the replaced drive to isolate the trouble to the subassembly parts.  
To shorten the troubleshooting time and repairing time, gather the data, such as environmental  
data and other information, from the user and then return the failed drive to the factory with  
the media defect list to repair.  
At the factory, user environment is made and a reappearance test is performed. To  
reappearance a same trouble at user, the failed drive is connected to the host system. If no  
trouble occurs by the normal test, the reappearance test is performed by adding the  
voltage/temperature load using a disk drive tester or tools according to the user environment.  
When a trouble reappeared, troubleshoot the cause of failure. Then, replace the failed unit or  
parts.  
As this level maintenance is made by a factory, this maintenance level is beyond the scope of  
this manual.  
The disk enclosure must never to opened in the field. Opening the  
disk enclosure may cause irreparable damage.  
1 - 12  
C141-F029-01EN  
CHAPTER 2  
REMOVAL AND REPLACEMENT  
PROCEDURE  
2.1  
2.2  
Spare Parts  
Disk Drive Removal  
This chapter explains the procedure for removing and replacing the disk drive. It is assumed that the  
reader has a thorough knowledge of replacing the complete disk drive and replacing the power-  
interface cable.  
When carrying out these procedures, note the following items.  
·
·
·
The disk drive must have been removed from the host system.  
A power-interface cable to the disk drive must be disconnected.  
Mounting is done by reversing the steps for removal.  
To carry out maintenance properly, observe the following:  
·
·
·
·
Place removed screws and other parts where they will not get lost or damaged.  
Keep a record of all maintenance work.  
Tighten screws securely but not excessively.  
Before touching the PCA, perform the human body grounding to discharge any static electricity  
from your body. This ensures that the worker will not electrically damage the PCA.  
2.1  
Spare Parts  
See Table 2.1 for the model and parts numbers to order the replacement disk drive.  
C141-F029-01EN  
2 - 1  
Table 2.1 Model and parts numbers  
Model  
Part Number  
Formatted  
capacity  
Mounting Screw  
MPC3032AT  
MPC3043AT  
MPC3064AT  
MPC3084AT  
MPC3096AT  
MPC3102AT  
CA01675-B321  
CA01675-B331  
CA01675-B341  
CA01675-B561  
CA01675-B361  
CA01675-B661  
3243.66 MB  
4325.52 MB  
6488.29 MB  
8455.20 MB  
9747.58 MB  
10242.74 MB  
No. 6-32UNC  
2.2  
Disk Drive Removal  
The method and procedures to dismount the disk drive to check the jumper terminal, change  
the jumper position, or replace the device differ depend on the system cabinet structure.  
Therefore, for actual working procedures, the specific conditions necessary for each system  
must be determined. The general removal procedures, with notes, is as follows.  
a) Disconnect the power-interface cable.  
b) Remove the screws that attach the drive and remove the drive from the system cabinet.  
c) When storing or transporting the drive, pack it an antistatic bag.  
Note:  
To protect the device from damage and prevent the worker getting hurt, observe the parts  
in Subsection 1.1.1 on Danger and Warnings.  
1. Perform any removal after the system power is completely  
disconnected. The cable must not be disconnected and the  
screws that attach the drive must not be removed with the power  
ON.  
2. Do not move the drive until it comes to a complete stop (about  
30 seconds after the power is turned OFF).  
3. Perform the human body grounding to discharge any static  
electricity from your body.  
2 - 2  
C141-F029-02EN  
This page is intentinally left blank.  
Comments concerning this manual can be directed to one of the following addresses:  
FUJITSU LIMITED  
Business Planning  
FUJITSU ICL ESPAÑA S.A.  
Almagro 40, 28010 Madrid, SPAIN  
Solid Square East Tower  
580 Horikawa-cho,Saiwai-ku, Kawasaki,  
210-0913, Japan  
TEL:  
FAX:  
34-1-581-8100  
34-1-581-8125  
TEL:  
FAX:  
81-44-540-4056  
81-44-540-4123  
FUJITSU AUSTRALIA LIMITED  
2 Julius Avenue (Cnr Delhi Road) North Ryde N.S.W. 2113,  
AUSTRALIA  
FUJITSU COMPUTER PRODUCTS OF AMERICA, INC.  
2904 Orchard Parkway, San Jose,  
TEL:  
FAX:  
61-2-9776-4555  
61-2-9776-4556  
California 95134-2009, U.S.A.  
TEL:  
FAX:  
1-408-432-6333  
1-408-432-3908  
FUJITSU HONG KONG LTD.  
Room 2521, Sun Hung Kai Centre, 30 Harbour Road, HONG  
HONG  
FUJITSU CANADA INC.  
2800 Matheson Blvd. East, Mississauga, Toronto,  
Ontario L4W 4X5, CANADA  
TEL:  
FAX:  
852-2827-5780  
852-2827-4724  
TEL:  
FAX:  
1-905-602-5454  
1-905-602-5457  
FUJITSU KOREA LTD.  
Coryo Finance Center Bldg, 23-6, YoulDo-Dong,  
Young DungPo-Gu, Seoul, Republic of KOREA  
FUJITSU EUROPE LIMITED  
2, Longwalk Road, Stockley Park, Uxbridge,  
Middlesex UB11 1AB, ENGLAND  
TEL:  
FAX:  
82-2-3787-6000  
82-2-3787-6070  
TEL:  
FAX:  
44-81-573-4444  
44-81-573-2643  
FUJITSU COMPUTERS (SINGAPORE) PTE. LTD  
20 Science Park Road #03-01,  
TELETECH PARK SINGAPORE SCIENCE PARK II,  
Singapore 117674  
FUJITSU DEUTSCHLAND GmbH  
Frankfurter Ring 211, 80807 München, GERMANY  
TEL:  
FAX:  
65-777-6577  
65-771-5499  
TEL:  
FAX:  
49-89-323780  
49-89-32378100  
FUJITSU TAIWAN LTD.  
FUJITSU NORDIC AB  
Kung Hans Väg 12, S-192 68 Sollentura, SWEDEN  
8F, Hun Tai Center, 168-170, Tun Hwa North Road,  
1st Sec., Taipei, TAIWAN  
TEL:  
FAX:  
46-8-626-6000  
46-8-626-6711  
TEL:  
FAX:  
886-2-545-7700  
886-2-717-4644  
FUJITSU ITALIA S.p.A.  
Via Nazario Sauro, 38 20099 Sesto S. Giovanni (MI), ITALY  
FUJITSU SYSTEMS BUSINESS (MALAYSIA) SDN. BHD.  
Fujitsu Plaza, 1A, Jalan Tandang 204, P.O. Box 636 Pejabat Pos  
Jalan Sultan  
TEL:  
FAX:  
39-2-26294-1  
39-2-26294-201  
46770 Petaling Jaya, Selangor Darul Ehsan, Malaysia  
TEL:  
FAX:  
60-3-793-3888  
60-3-793-0888  
FUJITSU FRANCE S.A.  
I, Place des Etas-Unis, SILIC 310,  
94588 Rungis Cedex, FRANCE  
FUJITSU SYSTEMS BUSINESS (THAILAND) LTD.  
12th F1., Olympia Thai Tower, 444 Rachadapisek Road,  
Samsennok, Huay Kwang, Bangkok 10320, Thailand  
TEL:  
FAX:  
33-1-41-80-38-80  
33-1-41-80-38-66  
TEL:  
FAX:  
66-2-512-6066  
66-2-512-6068  
10  
FUJITSU LIMITED  
Reader Comment Form  
We would appreciate your comments and suggestions for improving this publication.  
Publication No.  
Rev. Letter Title  
Current Date  
How did you use this publication?  
Learning  
Is the material presented effectively?  
Sales  
Installing  
Fully  
Well  
Well  
Organized  
Clean  
covered  
Illustrated  
Reference  
Operating  
Maintaining  
What is your overall rating of this publication?  
What is your occupation?  
Very Good  
Good  
Fair  
Very Poor  
Poor  
Your other comments may be entered here. Please be specific and give page,  
paragraph and line number references where applicable.  
Your Name & Return Address  
Thank you for your interest. Please send this sheet to one of the addresses in a left page.  

NEC Electronics America Cell Phone 85480QRO02 User Manual
Motorola MOTO Q 9h Global User Manual
Marantz PMD670 User Manual
Kenwood KDC U449 User Manual
Jura Capresso F707 User Manual
IBM Computer Drive DS4700 Express User Manual
Hamilton Beach Coffeemaker 840192402 User Manual
Black Box LTL KL User Manual
Asus CARTE MERE A7N8X E User Manual
APC SBP3000RM2U User Manual