MCS-425 Microwave sensor switch
Installation Instruction
How to use
1.Before turning-on this unit, please make sure all cables are
connected properly.
2.The mounting height is 230 cm.
3.Antenna angle (D) is adjustable, the higher the antenna angle,
the wider the detection range that can be detected. Instead, the
lower the antenna angle, the narrower the detection range that
can be detected.
4.Turn the (A) clockwise to increase the antenna detection range,
or the counter-clockwise turn to decrease the antenna detection
range.
Jumper
+ AC/DC 12~24V
-
N.C
Com.
N.O.
N.C.
N.O.
A
C
D
5.Turn the (C) clockwise to increase the relay actuation time, or
the counter-clockwise turn to decrease the relay actuation time.
LED
A
C
Clockwise turns on switch to is biggest.
Clockwise turns on switch to increase the
relay actuation time. (0.5 ~ 4 Seconds)
Relay mode and Jumper Status
The factory settings
No power
Relay Statue
Detects the signal
Relay Action Status
Microwave Antenna stand angel: 35°
Jumper: N.O. (Normal open)
Adjustment resistance:
(A) Clockwise turns on switch to is
biggest.
Jumper mode
Relay Normal Status
N.O.=OPEN
N.C.=CLOSED
LED OFF
N.O.=CLOSED
N.C.=OPEN
N.O.=OPEN
N.C.=CLOSED
LED OFF
N.O.
LED ON
(C) Clockwise turns on switch to
increase the relay actuation time.
Detection Range: 4.5 meter
N.O.=CLOSED
N.C.=OPEN
N.O.=OPEN
N.C.=CLOSED
N.O.=OPEN
N.C.=CLOSED
N.C.
LED ON
LED OFF
LED OFF
Specifications
Power Input: 12 V~24V AC/DC (self-regulating)
Maximum current: 80 mA
Frequency: 10.525 GHz
Relay actuation time: 0.5 ~ 4 Seconds
Sensor Angle: 7.5° ~ 82.5°
Operating Temperature Range: -20°C ~ +55°C
Dimensions: 122.5(W) * 72(H) * 63 (D)mm
Relay rated 3A, 125VAC / 30VDC
Application
MCS-425 microwave sensor switch can be used with access control system which it can work as a request to exit.
The diagrams below illustrate the two recommended ways of installing the MCS-425 and access control devices after power input
(power on).
Fig. B The connection for fail-secure Lock devices:
Fig. A The connection for fail-safe Lock devices:
Jumper(N.C.)
Power Supply
Jumper(N.C.)
Power Supply
+
+
N.C.
N.C.
-
N.C
-
N.C
Com.
N.O.
Com.
N.O.
Locking Device
(fail-secure)
Locking Device
(fail-safe)
Control Device
Control Device
N.C
Com.
N.O.
N.C
Com.
N.O.
Relay output
control
Relay output
control
Copyright © 2008 Gianni industries, inc. All rights reserved.
P-MU-MCS-425 Ver. C Published on 2008.08.20
|