VEC012B
Jump ‘n Charge™
12V Battery Charger and Jump Start System
IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR VECTOR
PURCHASE CALL TOLL FREE (866) 584-5504. IN MOST CASES A
VECTOR SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM
OVER THE PHONE.
KEY INFORMATION YOU SHOULD KNOW:
• BUILT-IN 12V BATTERY CHARGER
• PORTABLE, CORDLESS, RECHARGEABLE
• SAFETY WARNING ALARM SYSTEM
• ULTRA BRIGHT LED AREA LIGHT
BEFORE RETURNING THIS PRODUCT FOR ANY REASON,
PLEASE CALL TOLL FREE (866) 584-5504
OWNER’S MANUAL AND
WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,
OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. READ
CAREFULLY BEFORE USE, AND RETAIN FOR FUTURE REFERENCE.
4140 S.W. 28th Way, Ft. Lauderdale, FL 33312
Toll Free: (866) 584-5504
7. Do not disassemble charger; take it to a qualified service technician when serv-
ice or repair is required. Incorrect reassembly may result in a risk of electric
shock or fire and will void warranty.
8. To reduce risk of electric shock, unplug charger from outlet before attempting
any maintenance or cleaning. Turning off controls will not reduce this risk.
9. Do not expose charger to rain, snow or use when wet.
10. Never charge a frozen battery.
PERSONAL PRECAUTIONS AND SAFETY
1. Another person should be within range of your voice or close enough to come to
your aid when you work near a lead-acid battery.
2. Fresh water and soap should be nearby in case battery acid contacts skin,
clothing or eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while
working with a battery. Acid, acid particles or corrosion may get into eyes.
Immediately flood eye with cold water (Eye Wash Station) for at least 10 minutes
and seek medical attention immediately.
4. If battery acid contacts skin or clothing, wash immediately with soap and water.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
CAUTION: Dropping a metal tool onto battery might spark or short-circuit the battery
or other electrical part that may cause explosion.
6. Remove personal metal items such as rings, bracelets, necklaces, and watches
when working with a lead acid battery. A lead-acid battery can produce a short-
circuit current high enough to cause a severe burn.
CAUTION:
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installa-
tion. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the fol-
lowing measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment to an outlet on a circuit different from that to which
the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
2
AC POWER CORD CONNECTION
This charger is equipped for use with an extension cord. The extension cord must be
first connected to the charger’s polarized plug. Only then should the extension cord
be plugged into a properly installed 110/120VAC outlet in accordance with all local
codes and ordinances. This battery charger plug is for use with 110/120VAC ONLY.
DANGER: NEVER alter the extension cord or plug – if it will not fit an outlet, have a
proper outlet installed by a qualified electrician. An improper connection
may result in electric shock and will void warranty.
INTRODUCTION AND FEATURES
Use the Jump-Start/12 Volt DC Battery Charger System:
•
To jump-start any engine system with a standard 12 volt DC battery: boat; truck; car; air-
plane; RV; personal watercraft; snowmobile; garden tractor; gasoline engine gener-
ator, etc.
•
As a 12 Volt DC Power Supply: Operate 12 volt DC fans, inflators, fluorescent worklights,
cellular phones (can quick-charge a cellular phone by using the phone’s 12 volt DC
adapter cord), spotlights, TVs, portable radios, cassette or CD players, and more.
•
As a 12 Volt DC Battery Charger: The Jump ‘n Charge system has an easy-to-read series of
LED (Light Emitting Diode) charge indicators that show when the unit is fully charged, or
the level of charge in the battery. Charge level can be viewed when the charge status
pushbutton is pressed. A 12 volt DC power accessory outlet is provided for use with appli-
ances that can operate from a vehicle 12 volt DC accessory outlet. This allows maxi-
mum portability and utility when the Jump-Start System is used in remote locations.
The Jump ‘n Charge system can be recharged from any standard 110/120 volt AC
power source using a household extension cord.
A built-in 12 volt DC appliance outlet and the appropriate DC/DC charging/adapter
cord is used to recharge the battery from another 12 volt DC source. When pressed, the
CHARGE STATUS button will show the battery power level status (from LOW to HIGH).
The green LED full indicator illuminates when the unit is fully recharged and charging can
be discontinued. An ON/OFF switch operates the built-in work/emergency light.
FEATURES
• Exclusive automatic ON/OFF power control ensures safety and resists sparking
• Reverse polarity warning alarm sounds to alert a reverse polarity connection
• Ultra bright LED emergency area light
• 12 volt DC charging cord for charging from vehicle
• High-density, 19Ah, sealed, non-spillable battery
• 12 volt DC power outlet for accessories and appliances
• Heavy duty welder-type cable and clamps
• Clamps power-on only with proper polarity connection
• Digital display shows charge rate, operating mode, fault codes and FUL when
charged
• Instant Start capability
• Three-stage automatic rapid charging
• Compensate for low AC from extension cord use
3
SMART BATTERY CHARGER
The charger portion of the system is microprocessor-based and has three charge rate set-
tings, controlled by one switch. (See Figure 1).
1. Stage One- Rapid Start Charge- delivers maximum charging amperage to “wake
up” any serviceable 12 volt battery. When battery reaches a maximum safe prede-
termined voltage, the charger will automatically move into Stage 2 of the charging
process.
2. Stage Two- Absorption Charge maintains the maximum possible charge at a con-
stant, safe, predetermined voltage. During the phase, voltage absorption regula-
tion charge, the charging voltage remains constant, while the actual charging cur-
rent is reduced to allow for the maximum proper internal chemical energy transfer.
3. Stage Three- Top-Off Charge voltage is automatically maintained and reduced to
a predetermined level while current is adjusted for a safe, effective 100% battery
charge (step-down regulation mode). This is ideal for topping off batteries that have
been in storage.
Stage One
Figure 1
BEEP
BEEP
Stage Two
Stage Three
OFF
CHARGING COMPLETE
Amps
Size
2 amps
smaller batteries as in lawn mowers, snowmobiles,
motorcycles, etc.
4 amps
6 amps
mid sized batteries as in watercraft and motorcycles
automobile batteries
BATTERY STATUS DISPLAY
To check the battery status press the PUSH button ‘For Battery Low Level Battery Status’.
1. If all 4 indicators light (1 green light and 3 red lights) the battery is fully charged.
2. If 3 red indicators light, the battery is useable.
3. If 2 red indicators light, the battery is 1/2 discharged. Recharging is
recommended.
4. If 1 red indicator lights, the battery needs a full recharge.
4
PREPARING TO CHARGE
1. Determine voltage of battery by referring to car owner's manual.
2. If it is necessary to remove battery from vehicle to charge, or to clean terminals,
always remove grounded terminal from battery first. Make sure all accessories in
the vehicle are off, so as not to cause an arc.
3. Clean battery terminals. Be careful to keep corrosion from coming in contact with
eyes.
4. Add distilled water in each cell until battery acid reaches level specified by bat-
tery manufacturer. This helps purge excessive gas from cells. Do not overfill. For
a
battery without cell caps (maintenance free), carefully follow
manufacturer's charging instructions.
5. Study all battery manufacturers' specific precautions such as removing or not
removing cell caps while charging and recommended rates of charge.
6. Area around battery should be well ventilated while battery is being charged.
7. Make sure the initial charging rate does not exceed battery manufacturers
requirement.
CHARGER LOCATION
1. Locate charger as far away from battery as cables permit.
2. NEVER place charger directly above battery being charged; gases from battery
will corrode and damage charger.
3. NEVER allow battery acid to drip on charger when reading specific gravity or fill-
ing battery.
4. NEVER operate charger in a closed-in area or restrict ventilation in any way.
5. Marine batteries must be removed and charged on shore.
6. Do not set a battery on top of charger.
DC CONNECTION PRECAUTIONS
1. Connect and disconnect DC output clamps only after removing AC cord from
electric outlet.
2. Never allow clamps to touch each other.
3. Attach clamps to battery posts and check for secure connection. This will hold
clamps securely on terminals and helps to reduce risk of sparking.
FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE. A SPARK NEAR THE
BATTERY MAY CAUSE A BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR
THE BATTERY:
1. Position AC and DC cords to reduce risk of damage by hood, door, or moving
engine part.
2. Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to
persons.
3. Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has
larger diameter than NEGATIVE (NEG, N,-) post.
4. Determine which post of battery is grounded (connected) to the chassis. If nega-
tive post is grounded to chassis as in most vehicles), see (5). If positive post is
grounded to the chassis, see (6).
5
5. For negative grounded vehicle, connect POSITIVE (RED) clamp from battery
charger to POSITIVE (POS, P, +) post of battery. Connect NEGATIVE (BLACK)
clamp to vehicle chassis or engine block away from the battery. Do not connect
clip to carburetor, fuel lines, or sheet metal body parts. Connect to heavy gauge
metal part of frame or engine block.
6. For positive-grounded vehicle, connect NEGATIVE (BLACK) clamp from battery
charger to NEGATIVE (NEG, N, -) ungrounded post of the battery. Connect POS-
ITIVE (RED) clamp to vehicle chassis or engine block away from battery. Do not
connect clip to carburetor, fuel lines, or sheet metal body parts. Connect to heavy
gauge metal part of frame or engine block.
7. When disconnecting charger, turn switches off, disconnect AC cord, remove
clamp from vehicle chassis, and then remove clamp to battery terminal.
8. See operating instructions for length of charge information.
9. Do not charge the battery while engine is operating.
CHARGING THE BATTERY IN A VEHICLE
1. Check polarity of battery posts - For top-mounted battery posts, the Positive post
(marked POS, P, +) usually has a larger diameter than the Negative battery post
(marked NEG, N, -). For side-mounted battery terminals, the terminals are
marked Positive -red and Negative -black.
2. Attach charger clamps to battery connections, as follows, ensuring a good con-
nection (if there is a mistake, the Reverse Polarity Indicator will light): NEGATIVE-
GROUNDED VEHICLE: Connect the POSITIVE (RED) charger clamp to the POSI-
TIVE (POS, P, +) battery post.
3. Connect the NEGATIVE (BLACK) charger clamp to the vehicle chassis, or the
engine block (away from the battery). Do not connect the clamp to the carbure-
tor, fuel lines, or sheet-metal body parts: connect only to a heavy gauge metal
part of the frame or engine block.
NOTE: The NEGATIVE-GROUNDED system is the most common in today's
vehicles.
4. Set charger's Charge Rate 2/4/6 Amp to appropriate setting according to bat-
tery size.
5. Plug battery charger power cord into grounded AC power outlet and refer to
page 8 for approximate charging times.
6. When charging is completed, disconnect cables and clamps in reverse order from
which they were connected.
CHARGING THE BATTERY OUTSIDE A VEHICLE:
1. Check polarity of battery posts- For top-mounted battery posts, the Positive bat-
tery post (marked POS, P, +) usually has a larger diameter than the Negative bat-
tery post (marked NEG, N, –). For side-mounted battery terminal connections the
Positive terminal is red, the Negative terminal is black.
2. Attach a 24-inch (minimum length) #6 AWG insulated battery cable to the
Negative battery post (marked NEG, N, -).
3. Connect the Positive (RED) battery clamp to the Positive battery terminal (marked
POS, P, + or red).
4. Stand as far back from battery as possible, and do not face battery when mak-
ing final connection.
6
5. Carefully connect Negative (BLACK) charger clamp to the free end of the bat-
tery cable connected to the negative terminal. Connect the charger's power
cord to a grounded 110/120VAC power outlet.
6. Set charger's charge rate to appropriate setting according to battery size.
7. When charging is complete, disconnect cables and clamps in reverse order from
which they were connected.
OPERATION
This Jump ‘n Charge system has three user selected charge rates; 2, 4 and 6 amps.
Pressing the 2/4/6 Amp button selects the desired charge rate. The selected Charge
Rate is indicated by a lit vertical LED bar.
Once clamps are connected, AC is connected and there is no reverse polarity condi-
tion, press the 2/4/6 Amp button and the charger will begin charging at 2 Amps
after the “battery condition pre-test” is complete. Pressing the 2/4/6 Amp button a
second time will advance the charge rate to 4 Amps, a third time to 6 Amps. Pressing
the button a forth time will turn OFF the charger output and display
2 Amps press the Charge Rate button.
. To return to
000
Alternator
Check
2/4/6
Amp
Digital Display
ON/OFF
Polarized Plug
Alternator
Good
Power
Fault
Figure 3 - Charger Controls and Indicators
7
CHARGING TIMES
The Charger will automatically adjust the charge rate as the battery charges and stops
charging when the battery is fully charged. If you require some estimate of the time it
takes to charge a battery refer to the chart below.
PERCENT OF CHARGE 75%
50%
25%
0%
2 AMPS
4 AMPS
6 AMPS
7 HRS
3.5 HRS
2.5 HRS
13 HRS
6 HRS
5 HRS
NR*
9 HRS
7 HRS
NR*
12 HRS
9 HRS
* Not recommended.
The times shown in the chart above are approximate and refer to an average auto-
motive battery. For smaller batteries, the charge time should be adjusted using the for-
mula shown below and adding 1 hour to the time calculated. To estimate charging
time for a discharged battery, divide the amp hour (AH) rating of the battery by the
charge rate selected. This is the number of hours required to recharge the battery. For
example, a 50 Ah (12 volt) battery is discharged (10 volts).
Question: How long should it be charged at the 6 Amp rate?
Divide the 50 Ah by 6.
Answer: Approximately 8 hours. Always round up charge time by 10% to ensure full
charge. In most cases, battery charge times will vary depending on age and condi-
tion of battery. Smaller batteries should be charged at the lower rate (2 Amps) and
add an extra hour to charge time.
NOTE: Deep cycle batteries may need longer charging time. It is recommended to
repeat the charging cycle a second time beginning with the 2 Amp rate.
CARE AND MAINTENANCE
With minimal maintenance, the Jump ‘n Charge system will provide years of depend-
able service.
•
•
•
After each use, clean the battery charger clamps - be sure to remove any battery
fluid that will cause corrosion of the copper clamps.
Clean the outside case of the charger with a soft cloth and, if necessary, mild soap
solution.
Do not use charger if cords or clamps have been damaged in any way - call
Vector Technical Support Department toll-free: (866) 584-5504 for replacement
cords/clamps.
TROUBLESHOOTING
NOTE: Charger will NOT operate on batteries below 4.0 volts. If a 12 volt battery is
below 4.0 volts, it is probably shorted, open or sulfated. Replace the battery.
The following conditions may light the FAULT LED:
•
Charging too fast - Decrease Charge Rate - Press 2/4/6 Amp pushbutton to
select lower rate.
8
Try charging another battery, if the FAULT LED does not light, then one of the above
problems exists with the initial battery. Charger will not charge and the fan will not
operate if there is a fault. Call Vector Technical Support toll free: (866) 584-5504.
SULFATED BATTERY
Batteries left in a discharged state for a long period of time are likely to become "sul-
fated". Sulfated batteries cannot accept a high rate of charge since the internal plates
are coated with lead sulfate. To see if a battery in this condition can be "saved", take
it to a service station or battery distributor for professional evaluation and service.
INTERNAL SHORT CELL BATTERY
•
•
If the battery being charged has an internal shorted cell, the FAULT LED will light.
If FAULT LED light comes on, we recommend that you take your battery to a cer-
tified automotive service center for evaluation.
BATTERY NOT ACCEPTING A CHARGE
•
•
•
•
•
Make sure that the charger is plugged into a "live" 110/120VAC outlet and
POWER LED is lit.
Unplug charger and check battery connections - ensure there is a good connec-
tion with battery terminal and/or vehicle chassis.
Have the battery checked for sulfated condition (qualified service station or bat-
tery distributor).
Check that the correct charge rate has been selected for the battery being
charged.
Ensure that enough charging time has been allowed for-check table for approx-
imate charging times.
VERY COLD BATTERY
If the battery to be charged is extremely cold (in temperatures less than freezing - 0º
C/32º F) it cannot accept a high rate of charge, so the initial charge rate will be slow.
The rate of charge will increase as the battery warms.
9
CHARGER CONTROLS AND INDICATORS
Figure 3 shows the charger control panel of the Jump ‘n Charge system, and
consists of:
FUL
Digital Display - Displays
when battery is fully charged, and displays the Fault
Codes listed on page 9.
Polarized Plug - use with most household extension cords.
2/4/6 Amp pushbutton - Selects 2/4/or 6 amps .
ON/OFF pushbutton - Selects Off/On
Power LED - when lit indicates AC is applied to charger.
Fault LED - when lit indicates one or more abnormal conditions exist.
Alternator Good LED - Lights when Alternator Check is complete and alternator volt-
age is good.
NOTE: Each time the charger rate is changed, the charger sounds a beep. The only
time the selected charge rate does not display at the full selected rate is when
the battery is nearly full and charging at either steps two or three. The display
will show a slow charge rate. To return to 2 Amp setting, press the 2/4/6 Amp
button. When the battery is fully charged, “FUL” will be displayed .
NOTE: Small 12 volt DC batteries such as those used in motorcycles, garden tractors,
ATVs, jet skis, and snowmobiles can be damaged by high charge rates.
ALWAYS select the 2 Amp setting to charge this type of battery. For slower
charging time on larger batteries, select the 2 Amp setting.
ALTERNATOR CHECK PROCEDURE
NOTE: DISCONNECT THE 110/120V AC FOR THIS FUNCTION
1. Connect positive (+) red clamp to vehicle battery’s positive terminal.
2. Connect negative (-) black clamp to vehicle battery’s negative terminal.
3. Press ON/OFF pushbutton to turn unit on.
4. Press ‘Alternator Check’ pushbutton. The digital display will show bars.
5. After approximately 15 seconds, Alternator Good LED will illuminate.
6. If ‘Fault’ indicator lights, the alternator is not in good working condition and
should be replaced.
REPLACEMENT PARTS
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer Service:
(954) 584-4446 or toll-free (866) 584-5504.
Battery Replacement
It is recommended that the unit be returned to Vector Customer Service for
battery replacement: Contact (954) 584-4446 or toll-free (866) 584-5504.
10
WARNING
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty
electrical tape to prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat as it may explode
Battery Disposal:
This unit contains a maintenance-free, non-spillable, sealed
lead-acid battery. This battery is fully recyclable and should be
PRBA
PRBA
accepted at any location that accepts common automotive
starter batteries. Examples of places that accept these batteries
are: County or municipal recycling drop-off centers, scrap metal
dealers and retailers who sell automotive replacement lead acid
starter batteries. For more information on recycling this battery,
call toll-free (877) 288-7722.
ALWAYS RECYCLE
Figure 2 - Jump ‘n Charge Controls and Indicators
12 Volt DC
Power Source
Reverse Connection Light
Good Connection Light
Four Battery
Battery
Level Status
LEDs
Level Status
PUSH Button
JUMP ‘N CHARGE CONTROLS AND INDICATORS
Figure 2 shows the Jump ‘n Charge system control panel, and consists of:
• Four Battery Level Status LEDs indicating Low to High levels of battery level status
•
•
•
•
Battery Level Status (PUSH) button lights LEDs above.
Good Connection Light indicates a good clamp and terminal connection.
Reverse Connection Light indicates the clamps are reversed.
12 Volt DC Power Source Outlet for use with 12 volt DC appliances and recharge
from vehicle battery
11
READ AND OBSERVE ALL CAUTIONS AND WARNINGS
STEP-BY-STEP JUMP-STARTING INSTRUCTIONS
This Jump ‘n Charge system is equipped with an automatic ON/OFF function that
only allows Jump ‘n Charge energy to flow when proper connections are made to
the battery and frame. The automatic ON/OFF function works in conjunction with
an audible reverse polarity alarm and a large red LED light.
If inadvertent reverse polarity occurs, the alarm will sound and the red LED will
light. If this occurs, disconnect the black clamp (negative clamp) first, then the red
clamp. Reconnect properly and a green LED will light .
NOTE: The Green LED will not light if the battery’s voltage is less than 3 volts.
Either wait or charge the battery until the voltage is higher than 3.
CONNECT – Red clamp first, then black clamp.
DISCONNECT – Black clamp first, then red clamp.
1. Turn OFF vehicle ignition and all accessories (radio, A/C, lights, cell phone,
etc.). Place vehicle in park and set the emergency brake.
2. Remove booster clamps from clamp holder.
3. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (NEGATIVE
BATTERY TERMINAL IS CONNECTED TO CHASSIS).
3a. Connect positive (+) red clamp to vehicle battery’s positive terminal.
3b. Connect negative (-) black clamp to chassis or a solid, non-moving, metal
vehicle component or body part. Never clamp directly to negative battery
terminal or moving part. If the audible alarm sounds, the polarity is not correct.
Reverse the connections.
4. Procedure for jump-starting POSITIVE GROUND SYSTEMS (NOTE: In the rare
event that the vehicle to be started has a Positive Grounded System (positive
battery terminal is connected to chassis) replace steps 3a and 3b above with
steps 4a and 4b, then proceed to steps 5 through 7 below.
4a.Connect negative (-) black clamp to vehicle battery’s negative terminal
4b. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving,
metal vehicle component or body part. DO NOT CLAMP DIRECTLY TO POSITIVE
BATTERY TERMINAL OR MOVING PART
5. A five (5) second delay is built into this jump-starter unit after the clamp connections
are made. This delay is designed to reduce the possibility of sparking upon
connection. We recommend waiting one (1) minute after making the clamp
connections prior to attempting to start vehicle.
6. Start vehicle (do not turn key for longer than 3-5 seconds).
7. After vehicle starts, remove clamps (disconnect the frame or engine clamp first,
followed by the battery cable) and replace them in the built-in storage
holders.
CAUTION:
1. If engine fails to start, leave ignition key turned off and disconnect the negative
(-) clamp first, then the positive (+) clamp. Try again later – the engine may be
flooded.
2. Recharge Jump ‘n Charge system after each use.
12
WARNING:
•
Always disconnect the engine or frame jumper clamp first; followed by the battery
jumper clamp.
•
There is a risk of explosive gases being released when batteries are charged or
discharged. Failure to follow instructions may cause property damage, explo-
sive hazard, and/or personal injury.
CHARGING/RECHARGING
For maximum battery life, we recommend the Jump ‘n Charge be kept fully charged
at all times. If the battery is allowed to remain in a discharged state,
battery life will be shortened.
NOTE: Recharging battery after each use will prolong battery life; frequent
discharges between recharges will reduce battery life.
1. Use a common household extension cord to connect to 110/120 volts AC out-
let.
2. Press ON/OFF pushbutton to turn the unit on.
3. Select 2/4/ or 6 amp charge rate.
IMPORTANT:
•
Make sure all switches are turned off during recharging
Recharge unit fully after each use
•
WARNING: Do not recharge for more than 3-4 hours maximum using 12 volt
DC method
OPERATION FOR DC CHARGING
1. Insert one end of the DC/DC charging adapter into the 12 volt DC accessory out-
let on the vehicle or boat.
2. Insert the plug at the other end of this charging adapter into recharging port on
the front panel of the unit.
3. When charging is completed, remove the power cord and store in a safe place.
DC/DC CHARGER/ADAPTER
This recharging method will NOT recharge the unit as effectively as recharging
from a 110/120 volt AC outlet. The 12 volt DC recharging procedure is
recommended only when it is necessary, as continued use of the 12 volt DC
recharging procedure may shorten the battery’s system life.
If unit is fully discharged, it is recommended that the vehicle being used for recharging be
left running while the unit is being charged via the 12 volt DC method.
13
OPERATION AS A 12 VOLT DC PORTABLE POWER SUPPLY
The 12 volt DC outlet provides 15 amps maximum current for 12 volt DC operat-
ed appliances.
1. Lift up the cover of the unit’s 12 volt DC accessory outlet (See Figure 2).
2. Insert the 12 volt DC plug from the appliance into the outlet on the unit.
3. Switch on the appliance, and operate as usual.
CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT
DRAW MORE THAN 20 AMPS DC.
Table I - Using the unit as a 12 volt DC Power Supply
Appliance
Estimated Power Usage
Operating Time
(hours)
(Watts)
1
Cell phone
Fluorescent light
Radio, fan, depth finder
Camcorder, VCR, spotlight
Power tools, bilge pump
Car vacuum
1-1/2 (talk time)
4
9
15
24
80
40
24
14
10
2
NOTE: All times are approximate and based upon a fully charged unit.
EMERGENCY AREA LIGHT
The Area Light is controlled by an ON/OFF switch. Make sure the area light is turned
OFF when the unit is being recharged or stored.
JUMP ’N CHARGE SPECIFICATIONS
Model No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VEC012B
Maximum Output Current (instant) . . . . . . . . . . . . . . . . . . . . . .450 Amps
Weight . . . . . . . . . . . . . . . . . . . . . . . . Approximately 17.8 lbs. (8.0 Kg)
Battery Type . . . . . . . . . . . . . . . . . . . . . . . .12 Volt, 19AH/20HR Sealed
Rechargeable Non-Spillable, Lead-Acid
Jumper Cables . . . . . . . . . . . . . . . . . . . . . . .Heavy Duty, Welding Cable
Cables Clamps . . . . . . . . . . . . . . . . . . . . . . . 450 Amp, Copper Clamps
Area Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ultra Bright LEDs
Vehicle Test Voltage . . . . . . . . . . . . . . . . . . . . . . . . .Greater than 3 Volts
Accessory Outlet
. . . . . . . . . . . . . . . . . .Self-Resetting Breaker 20 Amps
DC Charging Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Volt DC
Reverse Polarity Detection . . . . . . . . . . . . . . . . . . . . . . . . . .2 Volts (min)
12 Volt Outlet Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Amp
Charger Output . . . . . . . . . . . . . . . . . . . . . .12 Volt DC 6 Amp Maximum
Alternator Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13.5 - 16.0 Volt
14
2 YEAR LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the
responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other warranty,
other than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only, to be free of defects
in materials and workmanship for two years from the date of purchase without additional charge.
The warranty does not extend to subsequent purchasers or users. Vector Manufacturing, Ltd. will not
be responsible for any amount of damage in excess of the retail purchase price of the product under
any circumstances. Incidental and consequential damages are specifically excluded from coverage
under this warranty.
This product is not intended for commercial use. This warranty does not apply to accessories or dam-
age to units from misuse or incorrect installation. Misuse includes wiring or connecting to improper
polarity power sources.
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage pre-
paid to Vector Manufacturing. Any defective product, other than accessories, that is returned to
Vector Manufacturing within 30 days of the date of purchase will be replaced free of charge. If
such a product is returned more than 30 days but less than two years from the purchase date,
Vector Manufacturing will repair the unit or, at its option, replace it free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector
Manufacturing’s option. A unit may be replaced with a new or reconditioned unit of the same or
comparable design. The repaired or replaced unit will then be warranted under the terms of the
remainder of the warranty period. The customer is responsible for the shipping charges on all
returned items after 30 days. During the warranty period, Vector Manufacturing, Ltd. will be respon-
sible for the return shipping charges.
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting
from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to
usage or exposure to sunlight), accidents, damage during shipping to our service facility, alterations,
unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and main-
tenance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department (954) 584-
4446 or toll free (866) 584-5504 for general repair information and charges if applicable. You may
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations
on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser
specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Manufacturing Technical Support by
telephone, fax or mail. We suggest that you keep the original packaging in case you need to ship
the unit. When returning a product, include your name, address, phone number, dated sales receipt
(or copy) and a description of the reason for return and product serial number. After repairing or
replacing the unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector
Manufacturing. Enter “VEC012B” as Model and “Jump ‘n Charge” as Product Type. All Vector
Manufacturing, Ltd. products must be registered within 10 days of purchase to activate this war-
ranty. Mail the completed registration form, along with a copy of the original sales receipt to:
ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
4140 SW 28th Way, Ft. Lauderdale, FL 33312
PH: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556.
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.
DS041504
15
|