Universal Security Instruments Carbon Monoxide Alarm CD 9000 User Manual

Visit Us on the Web! www.universalsecurity.com  
MODEL CD-9000  
CARBON MONOXIDE ALARM  
OWNER'S MANUAL  
PLEASE READ AND SAVE!  
WHAT YOU SHOULD KNOW ABOUT CO  
Carbon monoxide (CO) is an insidious poison. It is a colorless, odorless, tasteless gas. It is a cumulative  
poison. Even low levels of CO have been shown to cause brain and other vital organ damage in unborn  
infants with no effect on the mother.  
The following symptoms are related to CARBON MONOXIDE POISONING:  
MILD EXPOSURE  
Slight headache, nausea, vomiting, fatigue (often described as "flu-like" symptoms).  
MEDIUM EXPOSURE  
Severe throbbing headache, drowsiness, confusion, fast heart rate.  
EXTREME EXPOSURE  
Unconsciousness, convulsions, cardiorespiratory failure, death.  
Many cases of reported CARBON MONOXIDE POISONING indicate that victims are aware they are  
not well, but they become so disoriented that they are unable to save themselves by either exiting the  
building or calling for assistance. Young children and household pets may be the first affected.  
Your CO alarm is designed to detect the toxic CO fumes that result from incomplete combustion, such  
as those emitted from appliances, furnaces, fireplaces and auto exhaust.  
A CO alarm is NOT A SUBSTITUTE for other combustible gas, fire or smoke alarms. This carbon  
monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion.  
CAUTION: This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor.  
Carbon monoxide gas may be present in other areas.  
WARNING: This product is intended for use in ordinary indoor locations of family living units. It is not  
designed to measure compliance with Occupational Safety and Health Administration (OSHA) commercial  
or industrial standards. Individuals with medical problems may consider using warning devices which  
provide audible and visual warnings for carbon monoxide concentrations under 30 PPM.  
WHAT YOU SHOULD DO IF THE ALARM SOUNDS  
Never disconnect a CO alarm to silence an alarm. The alarm will automatically sense when the level of  
CO in the air falls below the danger level. You should stay outside the residence in fresh air until the  
alarm is silenced. When the alarm sounds, do not stand too close to the alarm. The sound produced by  
the alarm is loud because it is designed to awaken a person in an emergency. Prolonged exposure to  
the alarm at a close distance may be harmful to your hearing.  
IMPORTANT CONSIDERATIONS  
YOUR CARBON MONOXIDE ALARM HAS BEEN DESIGNED AND IS  
WARRANTED TO OPERATE FOR FIVE YEARS.  
NOTE: MANUFACTURER RECOMMENDS REPLACEMENT OF ALARM FIVE  
YEARS AFTER DATE OF PURCHASE.  
 
MOUNTING LOCATION  
This CO alarm can be mounted on the wall or ceiling.  
WALL LOCATION: Locate the top of the alarm not more than 6 feet from the floor.  
CEILING LOCATION: Alarm should be mounted as close as possible to the center of a hallway or  
room. If this is not possible, the edge of the alarm should be at least 4 inches from any wall.  
FIGURE 3  
LOCATIONS TO AVOID  
Nuisance alarms are caused by placing alarms where they will not operate properly. To avoid nuisance  
alarms, do not place alarms:  
– Within 5 feet (1.5m) of any cooking appliance.  
– Near an open window or door, because the fresh air entering the opening may delay CO from  
reaching the alarm.  
– In damp or very humid areas or next to bathrooms with showers. Install alarms at least 10 feet (3m)  
away from bathrooms.  
– In very cold or very hot environments or in unheated buildings or outdoor rooms where the temperature  
can go below or above the operating range of the alarm. Temperature limits for proper operation  
are 40o -100oF (4.4o -38oC).  
– Good ventilation is recommended when household cleaning supplies or similar contaminants are  
used.  
– Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions,  
such as:  
– Wind direction and/or velocity, including high gusts of wind. Heavy air in the vent pipes (cold/  
humid air with extended periods between cycles).  
– Negative pressure differential resulting from the use of exhaust fans.  
– Simultaneous operation of several fuel burning appliances competing for limited internal air.  
– Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.  
– Obstructions in or unconventional vent pipe designs which can amplify the above situations.  
– Extended operation of unvented fuel burning devices (range, oven, fireplace, etc.)  
– Temperature inversions which can trap exhaust gasses near the ground.  
– Car idling in an open or closed attached garage, or near a home.  
What Levels of CO Cause an Alarm?  
Underwriters Laboratories Inc. UL2034 defines three specific alarm points by which all residential CO  
alarms must alarm. They are measured in parts per million (ppm) of CO over time (in minutes).  
UL2034 Required Alarm Points:  
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES.  
If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.  
If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.  
Page 3  
 
DEVELOPING YOUR OWN CO SAFETY PLAN  
This CO alarm can quickly alert you to the presence of CO - it cannot prevent toxic CO emissions.  
Please note that there are hazards against which CO detection may not be effective, such as gas leaks  
or explosions. The ultimate responsibility for protection against toxic CO fumes rests solely on you.  
Installing CO alarms is just the first step in protecting your family from toxic CO poisoning. We also  
suggest that you create an effective, comprehensive safety program as outlined below.  
1. Install CO alarms properly following the instructions in this manual. Keep your CO alarms clean - do  
not wash. Wipe with a clean towel. Test your alarms weekly and repair or replace them when they no  
longer function. As with any electronic product, alarms have a limited life and alarms that do not work  
cannot protect you.  
2. Develop a family escape plan and practice it with your entire family, especially small children.  
– Draw a floor plan of your home and find two ways to exit from each room. There should be one  
way to get out of each bedroom without opening the door.  
– Teach children what the CO alarm signal means and how they must be prepared to leave the  
residence by themselves if necessary.  
– Decide on a meeting place a safe distance from your house and make sure all children understand  
where they should go and wait if there is a dangerous CO condition.  
– Conduct CO safety drills at least every 6 months to make sure that everyone, even small children,  
knows what to do in order to escape safely.  
– Know where to go to call the Fire Department from outside your residence.  
This unit is designed to detect carbon monoxide (CO) entering its sensing chamber. It does not sense  
combustible gas (such as natural gas, propane or butane), heat, smoke or flames.  
NOTE: This CO alarm is designed for use within a single residential living unit only. In a multi-family  
building, the alarm may not provide early warning for residents if it is placed outside of the residential  
units, such as on outside porches, in corridors, lobbies, basements, or in other apartments. In multi-  
family buildings, each residential unit should have detectors installed as previously indicated.  
When properly located, installed, and maintained, this CO alarm is designed to provide early warning of  
developing poisonous CO conditions at a reasonable cost. This alarm monitors the air, and when it  
senses CO, it activates its built-in alarm. It can provide precious time for you and your family to escape  
from your residence before CO can seriously injure or kill. However, such an early warning is possible  
only if the alarm is located, installed, and maintained as specified in the Owners Manual.  
IMPORTANT: WHAT YOUR CO ALARM CAN AND CANNOT DO  
If the bedroom doors are usually closed at night, alarms should be placed in each bedroom as well as  
in the common hallway between them.  
CO alarms also may not sense CO on a different level of a residence or building. For example, a  
second floor alarm may not sense a CO leak on the first floor or in the basement. Therefore, alarms  
should be placed on every level of a residence or building.  
If the alarm is located outside of a bedroom, it may not wake up a sound sleeper, especially if the  
bedroom door is closed or only partly open. If the alarm is located on a different level of the residence  
than the bedrooms, it is even less likely to wake up people sleeping in the bedroom.  
Installing CO alarms may qualify you for lower homeowner's insurance rates, but CO alarms are not a  
substitute for insurance. Homeowners and renters should continue to insure their lives and property.  
WARNING: The Model CD-9000 alarm is not designed for marine use.  
Page 4  
 
INSTALLATION AND OPERATION  
INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY.  
CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE!  
A mounting plate is provided on the back of the alarm.  
Remove the mounting plate from the back of the alarm by holding the mounting plate and twisting the  
alarm in the direction indicated by the "OFF" arrow on the alarm cover.  
To ensure aesthetic alignment of the alarm with the hallway or wall, the "A" line on the mounting plate  
must be parallel with the hallway walls when ceiling mounting or horizontal when wall mounting (See  
Steps A and B).  
After selecting the proper carbon monoxide alarm location as described in Figure 1, attach the  
mounting plate on the wall. Be sure the "UP FOR WALL MOUNTING" text and arrow are facing up.  
Use the screws and anchors provided to secure the mounting plate.  
Install the battery in the correct orientation as noted on the inside of the battery door. The alarm will  
beep once, indicating proper battery installation.  
CAUTION! IF NO BATTERY IS INSTALLED, THE BATTERY DOOR WILL NOT CLOSE AND THE  
UNIT WILL NOT ATTACH TO THE MOUNTING BRACKET.  
Alignment marks are provided on the edge of the trim plate and the alarm. After installing the mounting  
plate, place the alarm on the mounting plate with the alignment marks lined up. Twist the alarm in the  
direction indicated by the "ON" arrow on the alarm cover (See Step D) until it locks in place.  
FIGURE 4  
USING TAMPER RESISTANT LOCKING PIN: To make your carbon monoxide alarm somewhat tamper  
resistant, a locking pin has been provided in the bag with the screws and anchors. Using this pin will  
deter children and others from removing the alarm from the mounting plate. To use the pin, insert it into  
the hole in the side of the alarm after the alarm has been installed on the mounting plate (See Figure 5).  
Note the tamper resistant pin will have to be removed in order to change the battery. This can be done  
easily with long nose pliers. Using the long nose pliers, pull the pin out of the hole. It is now possible to  
remove the alarm from the mounting plate.  
FIGURE 5  
Test alarm immediately following installation and weekly for proper operation by pushing the test  
button approximately three seconds until a short beep is heard. Release the button. The alarm will then  
test itself for proper operation and the red LED indicator will flash 4 times and the alarm will sound two  
4 pulse patterns. The alarm then resumes normal operation.  
Page 5  
 
NORMAL OPERATION  
In normal operation, the alarm will flash the red LED indicator once every 30 seconds.  
ALARM CONDITION  
If the alarm senses unsafe levels of CO, the red LED indicator will light up and the alarm will sound. The  
alarm condition will be signified by a repetitive alarm sounding pattern of 4 short beeps followed by 5  
seconds of silence. Immediate evacuation is required. Pushing the test button will silence the alarm for  
approximately 4 minutes. After approximately 4 minutes, the alarm will again sound until the unsafe CO  
concentration is removed.  
TROUBLE CONDITION  
Periodically, the alarm's measurement circuit is tested. If an error is detected, the alarm will sound and  
the red LED indicator will flash twice every 30 seconds. This is an indication of circuit malfunction and  
that the alarm requires immediate servicing.  
MAINTENANCE  
BATTERY REPLACEMENT  
IF THE TAMPER RESISTANT PIN HAS BEEN USED, REFER TO "TAMPER RESISTANT LOCKING  
PIN" FOR REMOVAL INSTRUCTIONS (See Figure 5).  
To replace the battery, remove the alarm from the mounting plate by rotating the alarm in the direction  
of the "OFF" arrow on the cover (See Figure 4, Step D).  
The CO alarm is powered by a 9V Alkaline battery. A fresh battery should last for one year under  
normal operating conditions. This alarm has a low battery monitor circuit which will cause the alarm to  
"chirp" and the red LED indicator to flash approximately every 30-40 seconds for a minimum of 7 days  
when the battery gets low. Replace the battery when this condition occurs. USE ONLY THE FOLLOWING  
9 VOLT BATTERIES FOR CO ALARM REPLACEMENT  
Alkaline type:  
Lithium type:  
EVEREADY 522; DURACELL MN1604; GOLD PEAK 1604A  
ULTRALIFE U9VL  
NOTE: REGULAR TESTING IS RECOMMENDED.  
WARNING! USE ONLY THE BATTERIES SPECIFIED. USE OF DIFFERENT BATTERIES MAY HAVE  
A DETRIMENTAL EFFECT ON THE CO ALARM. THE CONSTANT EXPOSURES TO HIGH OR  
LOW TEMPERATURES OR HIGH HUMIDITY MAY REDUCE BATTERY LIFE.  
CLEANING YOUR ALARM  
To clean your alarm, remove it from the mounting plate as outlined in the beginning of this section.  
You can clean the interior of your alarm by using your vacuum cleaner hose and vacuuming through the  
openings around the perimeter of the alarm.  
WARNING: The outside can be wiped with a damp cloth. Do not use any household cleaning agents,  
ammonia based cleaners, paints, varnishes or any other chemical on or near your alarm. AFTER  
CLEANING, REINSTALL YOUR ALARM. TEST YOUR ALARM BY USING THE TEST BUTTON.  
TESTING YOUR ALARM  
Test alarm weekly for proper operation by pushing the test button for approximately three seconds until  
a short beep is heard . Release the button. The alarm will then test itself for proper operation and the  
red LED indicator will flash 4 times and the alarm will sound two 4 pulse patterns. The alarm then  
resumes normal operation.  
Page 6  
 
UNIVERSAL FIVE (5) YEAR LIMITED WARRANTY  
Universal Security Instruments, Inc. ("Universal") warrants your Universal product to  
be free from defects in material and workmanship for a period of five (5) years from  
the date of purchase. During the initial one (1) year period commencing with the date of  
purchase, any repair or replacement will be made at a charge of five dollars ($5.00) to cover  
return postage and handling. During the latter four (4) years of the warranty period, any  
repair or replacement will be made at a charge to the purchaser not to exceed the  
manufacturer's cost of repair or replacement. This warranty applies only to the original  
consumer purchaser and only to products used in normal residential use and service. If this  
product is found to be defective, Universal's only obligation, and your exclusive remedy, is  
the repair or replacement of the product, at Universal's discretion, provided that the product  
has not been damaged through misuse, abuse, accident, modifications, alteration, neglect  
or mishandling. This Warranty shall not apply to any product which is found to have been  
improperly installed, set-up, or used in any way not in accordance with the instructions  
supplied with the product. This warranty shall not apply to any batteries used in the product  
or to any damage which may be caused by such batteries. For repair or replacement, send  
the defective product to Universal Security Instruments, Inc. at 7-A Gwynns Mill Court, Owings  
Mills, Maryland 21117, postage prepaid with a payment of five dollars ($5.00) to cover the  
costs of return postage and handling. You will be notified if any additional charges are  
required. You must include a proof of purchase (receipt) along with the returned product.  
UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY,  
WHETHER EXPRESS OR IMPLIED, OF FITNESS FOR A PARTICULAR PURPOSE,  
OTHER THAN THE WARRANTY CONTAINED HEREIN. NO IMPLIED WARRANTY ON  
THIS PRODUCT, CREATED BY STATE LAW, SHALL EXTEND BEYOND THE TERM OF  
THIS WARRANTY UNLESS SUCH LAW OTHERWISE PROVIDES. UNIVERSAL  
SPECIFICALLY DISCLAIMS ANY LIABILITY AND SHALL NOT BE LIABLE FOR ANY  
CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE, INCLUDING, BUT NOT LIMITED  
TO, DAMAGES TO ANY EQUIPMENT WITH WHICH THIS PRODUCT IS USED.  
Some states do not allow the exclusion or limitation of incidental or consequential damages  
so the above limitations or exclusions may not apply to you.  
No agent, representative, dealer, or employee of the company has the authority to increase  
or alter the obligations or terms of this Warranty.  
This Warranty gives you specific legal rights and you may also have other rights which vary  
from state to state.  
This Warranty is only valid for merchandise purchased from outlets in the United States and  
Canada.  
Visit Us on the Web!  
OWINGS MILLS, MARYLAND 21117 USA  
©2005, UNIVERSAL SECURITY INSTRUMENTS, INC.  
Printed in China  
288-3259-00A  
 

Thule Automobile Accessories 087 User Manual
Toshiba DVD Player SD 3990 User Manual
Toshiba Telephone IP 5000 Series User Manual
Triarch Indoor Furnishings 31028 User Manual
Univex Printer E120n User Manual
Vantec Computer Drive MRK 103F User Manual
Vermont Casting Indoor Fireplace DV4136LK User Manual
ViewSonic Projector PJ513D User Manual
Viking Refrigerator DFBB536 User Manual
Volkswagen Automobile R32 User Manual