UBC61 scanner Qk 3/12/02 11:22 AM Page 1
UBC
61XLT
Programmable
Hand-Held-
Scanner
OWNER’S
MANUAL
Pr i n t ed i n t h e Ph i l i p p i n es
U B Z Z 0 1 2 9 6 FZ
UBC61 scanner Qk 3/12/02 11:22 AM Page 3
Controls and Indicators
Contents
15
16
17
18
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . .2
What is Scanning? . . . . . . . . . . . . . . . . . . .2
What is Chain Searching? . . . . . . . . . . . . . .2
General Use . . . . . . . . . . . . . . . . . . . . . . . .2
Nickel - Cadmium Battery Warning! . . . . . .2
Feature Highlights . . . . . . . . . . . . . . . . . . . . .2
Function Keys . . . . . . . . . . . . . . . . . . . . . . . . .2
Controls and Indicators . . . . . . . . . . . . . . . . .3
15. Antenna Connector
16. Ear Phone Jack
17. Squelch Control
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installing the Batteries . . . . . . . . . . . . . . . . .4
AC Adapter/Charger . . . . . . . . . . . . . . . . . .4
Charging Warning . . . . . . . . . . . . . . . . . . . .4
Flexible Antenna . . . . . . . . . . . . . . . . . . . . .4
Belt Clip . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Optional Accessories . . . . . . . . . . . . . . . . . . .4
18. On/Off Volume Control
19
20
21
22
BATT
CHAIN
1
2
3
4
5
Basic Operation . . . . . . . . . . . . . . . . . . . . . . .5
MHz
SCAN HOLD PRI L/O WX SEARCH
Setting the Squelch . . . . . . . . . . . . . . . . . .5
Keylock . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
23 24
25
Programming . . . . . . . . . . . . . . . . . . . . . . . . .6
Duplicate Frequency Alert . . . . . . . . . . . . . .6
19. Chain Search Indicator
20. Frequency Display
Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Channel Lockout . . . . . . . . . . . . . . . . . . . . . .7
Lockout in Manual Mode . . . . . . . . . . . . . .7
Locking a Channel While Scanning . . . . . . .7
Restore a Locked Out Channel . . . . . . . . . .7
Restore All Locked-out Channels . . . . . . . .8
21. Keypad Lock Indicator
22. Low Battery Indicator
23. Priority Channel Indicator
24. Channel Indicator
Priority Scan . . . . . . . . . . . . . . . . . . . . . . . . . .8
Changing the Priority Channel . . . . . . . . . . .8
Chain Search . . . . . . . . . . . . . . . . . . . . . . . . .9
25. Function Indicators
Setting a Search Range . . . . . . . . . . . . . . .9
Search Hold Feature . . . . . . . . . . . . . . . . .10
Frequency Skip . . . . . . . . . . . . . . . . . . . . .10
Storing Search Frequencies . . . . . . . . . . .11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . .12
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3
UBC61 scanner Qk 3/12/02 11:22 AM Page 4
Charging Warning
Do not charge alkaline batteries in this scanner.
SETUP
Doing so may cause serious damage to the prod-
uct and void the warranty. Before attempting to
recharge batteries, make sure you have installed
four rechargeable nickel-cadmium batteries and the
selector switch is set to Ni-Cd BATT.
Installing the Batteries
1.Open the cover
Lift
Press in
Flexible Antenna
Attach the flexible
antenna to the BNC
connector.
2.Insert Batteries
Ni.-Cd.
BATT.
REG.
ALK.
BATT.
Belt Clip
Inside
of top
cover
Do not tighten the
screws too tight. You
can damage the case
or clip.
Note: If you are installing alkaline batteries, set the
switch to REG. ALK.BATT. If installing nickel-
cadmium batteries, set the switch to Ni-Cd
BATT.
3.Replace cover and press down
until it clicks into place.
Optional Accessories
Do not mix alkaline
batteries with Ni-Cd
batteries. Be sure to
install four batteries
of the same type.
AC Adapter / Charger
Cigarette Lighter Lead
WARNING
AC Adapter/Charger
Use the optional AC adapter/charger to power the
UBC61XLT from an AC outlet.
Use only the optional AC adapter.
4
UBC61 scanner Qk 3/12/02 11:22 AM Page 5
5. Turn SQUELCH back counter-clockwise just until
the hiss stops. Now the “Squelch Gate” allows
only strong signals through.
Basic Operation
Setting the Squelch
To set the squelch, you must be in the manual
mode.
No signal should be present when adjusting
squelch.
Strong Signals
Medium Signals
Weak Signals
Noise
•
MANUAL
1. Press
• SCAN
1
4
2
5
8
0
3
6
until you do not
hear a signal.
• MANUAL
7
9
SRCH SLCT
HOLD
CLEAR
Keylock
•
E
PRI
Keylock prevents accidental key entries during
scanning.
SKIP
L/O
LIGHT
WX
1. To lock the key
pad, press and
2. Adjust VOLUME
to a comfortable
listening level.
• SCAN
1
4
2
5
8
0
3
6
hold
until the
• MANUAL
key symbol
appears.
7
9
SRCH SLCT
HOLD
CLEAR
•
E
PRI
SKIP
L/O
WX
LIGHT
3. Think of Squelch Control as a gate. Turn
SQUELCH fully counter-clockwise. This raises
the “Squelch-Gate” so high that no signals can
get through.
4
460.4250
MHZ
SCAN
Strong Signals
Medium Signals
Weak Signals
Noise
2. To unlock the key
pad press and
• SCAN
1
4
2
5
8
0
3
6
hold
until
• MANUAL
the key symbol
disappears.
7
9
SRCH SLCT
HOLD
CLEAR
•
E
PRI
SKIP
L/O
4. Turn SQUELCH fully clockwise until you hear a
hiss. This lowers the “Squelch-Gate” so that
everything gets through - noise, weak signals,
and strong signals.
WX
LIGHT
4
460.4250
MHZ
Strong Signals
Medium Signals
Weak Signals
Noise
SCAN
5
UBC61 scanner Qk 3/12/02 11:22 AM Page 6
Duplicate Frequency Alert
If you enter a
Programming
frequency stored in
another channel, you
hear a beep and the
2
CH 10
L/O
Before the UBC61XLT can receive radio broad-
casts, you must program a frequency into at least
one channel before scanning, repeat this procedure
for each channel you program.
HOLD
other channel appears in the display.
Up to 80 channels may be programmed
.
E
Press
Press
to start again
or
again to store the
frequency in both
channels.
1. Select frequencies
• SCAN
1
4
2
5
8
0
3
6
2. Press
•
MANUAL
• MANUAL
Scanning
7
9
SRCH SLCT
HOLD
CLEAR
When you turn on the
power, the UBC61XLT
automatically starts in
the scan mode.
•
E
PRI
88
SCAN
SKIP
L/O
LIGHT
WX
SCAN
3. Select a channel
a) Enter the
During normal scan-
ning the scanner skips
unprogrammed or
• SCAN
1
4
2
5
8
0
3
6
SCAN
channel number
b) Then press
• MANUAL
CHANNELS
1 2 3 4 5 6 7 8 9 10
locked out channels.
•
MANUAL
7
9
SRCH SLCT
HOLD
When a transmission is
received, the scanner
stops on that channel.
When the transmission
ends, scanning
CLEAR
Frequency
locked out
(L/O)
Frequency
not entered
•
E
PRI
SKIP
L/O
LIGHT
WX
resumes automatically
after two seconds.
2
460.3750
MHZ
2
000.0000
MHZ
SCAN
HOLD
L/O
To stop on a channel
during scanning,
• SCAN
1
4
2
5
8
0
3
6
• SCAN
1
4
2
5
8
0
3
6
4. Enter the frequency.
a) Enter the
•
MANUAL
press
• MANUAL
• MANUAL
frequency number
7
9
E
b) Then press
SRCH SLCT
HOLD
7
9
SRCH SLCT
HOLD
CLEAR
CLEAR
•
E
PRI
•
E
PRI
SKIP
L/O
SKIP
L/O
LIGHT
WX
LIGHT
WX
2
460.3750
MHZ
2
460.4250
MHZ
HOLD
HOLD
To clear a mistake while entering the
To resume scanning
press
.
frequency, press
twice, and start over.
• SCAN
1
4
2
5
8
0
3
6
•
SCAN
• MANUAL
If the frequency entered is outside the frequency
range of the scanner, a distinctive beep sounds. (See
the table on page 2).
7
9
SRCH SLCT
HOLD
CLEAR
•
E
PRI
.
Press
SKIP
L/O
and go back to
step 4.
2
ERROR
L/O
LIGHT
WX
HOLD
SCAN
88
SCAN
6
UBC61 scanner Qk 3/12/02 11:22 AM Page 7
Locking a Channel While Scanning
Channel Lockout
If the scanner keeps stopping on a particular
channel due to noise or too frequent transmissions,
you may want to keep that channel from scanning.
You can lockout any channel so it is not reviewed
during normal scanning. You can restore the chan-
nel to scanning whenever you wish.
1. Wait until the
scanner stops at
the channel.
5
460.0750
MHZ
Lockout in Manual Mode
SCAN
•
MANUAL
1. Press
• SCAN
1
4
2
5
8
0
3
6
L/O
2. Then press
• SCAN
1
4
2
5
8
0
3
6
• MANUAL
• MANUAL
7
9
SRCH SLCT
HOLD
CLEAR
7
9
SRCH SLCT
HOLD
3. The scanner
immediately
•
E
PRI
CLEAR
•
E
PI
SKIP
L/O
resumes scanning
because the
LIGHT
WX
SKIP
L/
LIGHT
WX
locked out channel
is no longer in the
scanning
8
460.3750
MHZ
HOLD
SCAN
88
SCAN
sequence.
2. Select a channel
a) Enter the
channel
number
b) Then press
• SCAN
1
4
2
5
8
0
3
6
• MANUAL
Restore a Locked Out Channel
1. Press
7
9
SRCH SLCT
HOLD
•
MANUAL
CLEAR
•
MANUAL
•
E
PRI
again.
• SCAN
1
4
2
5
8
0
3
6
SKIP
L/O
LIGHT
WX
• MANUAL
7
9
SRCH SLCT
HOLD
8
460.3750
MHZ
CLEAR
HOLD
•
E
PRI
SKIP
L/O
LIGHT
WX
L/O
3. Press
• SCAN
1
4
2
5
8
0
3
6
to lockout the
channel.
• MANUAL
10
460.2250
MHZ
HOLD
7
9
SRCH SLCT
HOLD
CLEAR
•
E
2. Select a locked
out channel.
a) Enter the
channel
number
b) Then press
SKIP
L/
LIGHT
WX
• SCAN
1
4
2
5
8
0
3
6
• MANUAL
8
460.3750
MHZ
7
9
SRCH SLCT
HOLD
HOLD
L/O
CLEAR
•
MANUAL
•
E
PRI
again.
SKIP
L/O
LIGHT
WX
2
460.3750
MHZ
HOLD
L/O
7
UBC61 scanner Qk 3/12/02 11:22 AM Page 8
3. Press
unlock the
channel.
to
If you have
locked out
the priority channel,
this message
appears when you select
priority mode.
L/O
• SCAN
1
4
2
5
8
0
3
6
P ch Loc Out
HOLD
• MANUAL
7
9
SRCH SLCT
HOLD
CLEAR
•
E
I
SKIP
L/
PRI
2. Press
again
LIGHT
WX
• SCAN
1
4
2
5
8
0
3
6
at anytime to
deactivate priority
scan.
• MANUAL
2
460.3750
MHZ
HOLD
7
9
SRCH SLCT
HOLD
CLEAR
Restore All Locked-out Channels
1. Press
•
E
P
•
MANUAL
SKIP
L/O
• SCAN
1
4
2
5
8
0
3
6
LIGHT
WX
You must
be in
manual
• MANUAL
Changing the Priority Channel
You cannot eliminate the priority channel, but you
can change it to any other of the 80 available
channels.
7
9
SRCH SLCT
HOLD
mode before
restoring all locked-
out channels.
2. Press and hold
L/O
CLEAR
•
E
PRI
1. Press
•
MANUAL
• SCAN
1
2
5
8
0
3
SKIP
L/O
LIGHT
WX
• MANUAL
4
6
for about
two seconds.
You will hear two
beeps when all the
channels have been
restored.
7
9
• SCAN
SRCH SLCT
HOLD
1
4
2
5
8
0
3
6
CLEAR
• MANUAL
•
E
PRI
SKIP
L/O
LIGHT
WX
7
9
SRCH SLCT
HOLD
Empty chan-
nels cannot
be deleted
CLEAR
•
E
PRI
11
460.4750
MHZ
SKIP
L/O
and are always
locked out
LIGHT
WX
HOLD
2. Select a new
priority channel.
a) Enter the
channel
number
b) Then press
• SCAN
1
4
2
5
8
0
3
6
Priority Scan
• MANUAL
When priority scan is turned on, your scanner checks
the priority channel every two seconds for activity. If a
signal is present on the priority channel, your scanner
monitors the channel until the transmission ends, then
resumes normal scanning. You can designate any one
of the 80 available channels as your priority channel.
7
9
SRCH SLCT
HOLD
CLEAR
•
MANUAL
•
E
PRI
again.
SKIP
L/O
LIGHT
WX
To activate priority
4
460.4250
MHZ
• SCAN
1
4
2
5
8
0
3
6
scan (in either
manual or scan
mode):
HOLD
• MANUAL
7
9
SRCH SLCT
HOLD
PRI
1. Press
CLEAR
•
E
PRI
SKIP
L/O
LIGHT
WX
P
88
SCAN
SCAN
PRI
8
UBC61 scanner Qk 3/12/02 11:22 AM Page 9
CHAIN
2
3. Press and hold
PRI for two
seconds to desig-
nate this channel
as your new
2. Enter lower limit
of the search
band.
a) Enter the
frequency
number.
• SCAN
1
4
2
5
8
0
3
6
000.0000
MHZ
SEARCH
• MANUAL
7
9
SRCH SLCT
HOLD
• SCAN
1
4
2
5
8
0
3
priority channel.
CLEAR
b) Then press
•
E
PRI
• MANUAL
6
9
E
Two beeps indicate
that the priority
channel is changed.
SKIP
L/O
LIGHT
WX
7
SRCH SLCT
HOLD
CLEAR
•
E
PRI
P 4
460.4250
MHZ
SKIP
L/O
HOLD
PRI
LIGHT
WX
The display
alternates
between the upper
and lower ranges.
CHAIN
2
Chain Search
460.0000
MHZ
SEARCH
Use chain search to find active frequencies in your
area. You can search up to all five personal bands
or turn off those bands you don’t want to hear. This
gives you flexibility of searching for any channel
between 66 and 512 MHz, as long as they are with-
in the 8 frequency bands covered by the
UBC61XLT.
CHAIN
2
460.0000
MHZ
MHZ
SEARCH
and
CHAIN
2
See the table on page 2
000.0000
SEARCH
Setting a Search Range
An error message
3. Enter upper limit
of the search
band.
a) Enter the
frequency
number
2
CHAIN
• SCAN
1
4
2
5
8
0
3
6
displays when SRCH
is pressed and you
have not either
specified a search range in at least one chain
search band.
ERROR
MHZ
SEARCH
2
• MANUAL
7
9
SRCH SLCT
HOLD
CLEAR
b) Then press
E
•
E
PRI
-OR-
SKIP
L/O
LIGHT
WX
If you attempt to turn off all personal chain search
bands.
CHAIN
2
The error message turns off automatically and
chain 1 is selected
460.0000
MHZ
SEARCH
1
CHAIN
when all search
locations are empty.
000.0000
MHZ
1
SEARCH
The display
alternates
between the upper
and lower ranges. If
you program the
wrong limit press
CHAIN
2
•
MANUAL
Press
SLCT
to return to manual mode, or press
to select the band you want to program.
460.0000
MHZ
MHZ
SEARCH
and
To program a frequen-
cy range into one of
the five personal chain
search bands, follow
these steps:
CHAIN
2
• SCAN
1
4
2
5
8
0
3
6
E
and
o
then
E
o
press
460.5000
SEARCH
and
• MANUAL
again to erase the
error and reset the
limits to zero.
7
9
SRCH SLCT
HOLD
SLCT
1. Press
until
•
E
PRI
Then begin again.
the search location
you want appears in
the display.
SKIP
L/O
LIGHT
WX
9
UBC61 scanner Qk 3/12/02 11:22 AM Page 10
SRCH
4. Either press
to begin your
search.
2. Press
the next higher
frequency
to move
• SCAN
• SCAN
1
4
2
5
8
0
3
6
1
4
2
5
8
0
3
6
• MANUAL
• MANUAL
-OR-
(See step 3)
7
9
7
9
SRCH SLCT
HOLD
SRCH SLCT
HOLD
CLEAR
CLEAR
•
E
PRI
•
E
PRI
SKIP
L/O
SKIP
L/O
LIGHT
WX
LIGHT
WX
CHAIN
2
3. Press
to move
down to the
previous
frequency.
• SCAN
1
4
2
5
8
0
3
6
1
460.1750
MHZ
SEARCH
• MANUAL
Your scanner searches each selected chain
search band. The display flashes the
number of the band while it’s searched.
Other bands which are programmed and selected
are displayed but do not flash
7
9
SRCH SLCT
HOLD
CLEAR
•
E
PRI
SKIP
L/O
LIGHT
WX
CHAIN
3
-OR-
000.0000
MHZ
SEARCH
SRCH
4. Press
to
• SCAN
1
4
2
5
8
0
3
6
SLCT
Press
to move
resume searching.
to the next chain location.
• MANUAL
You can press the chain search band num-
SLCT
7
9
SRCH SLCT
HOLD
ber, followed by
location directly.
, to access the
CLEAR
•
E
PRI
SKIP
L/O
LIGHT
WX
5. To turn off a chain
search band
during searching,
press its location
number.
• SCAN
1
4
2
5
8
0
3
6
The search continues toward either the
upper or lower search limit, depending
• MANUAL
on which direction key ( or
pressed last.
) was
7
9
SRCH SLCT
HOLD
CLEAR
•
E
PRI
Frequency Skip
SKIP
L/O
If a particular frequency continues to interrupt
searching, it is possible to set your scanner to skip
the frequency.
LIGHT
WX
For example, (a) if
1
2
3
CHAIN
chain search
locations 1,2 and 3
are selected, (b)
3
If you scanner stops
while searching,
SKIP
• SCAN
1
4
2
5
8
0
3
6
a
b
1
460.4250MHZ
SEARCH
• MANUAL
press
to lock-
1
2
CHAIN
press
to turn
out the frequency
from the search
range.
7
9
off band three so
that it’s not scanned
during your search.
SRCH SLCT
HOLD
1
460.4375MHZ
CLEAR
SEARCH
•
E
PI
SKIP
L/O
LIGHT
WX
Search Hold
Feature
• SCAN
1
4
2
5
8
0
3
6
Press
or
at
You can program 10 skip frequencies. The
11th skip frequency entered causes the 1st
skip frequency to unlock.
• MANUAL
anytime to stop the
search.
7
9
SRCH SLCT
HOLD
CLEAR
To unlock all skip frequencies at once, follow the
next steps:
•
E
PRI
SKIP
L/O
LIGHT
WX
10
UBC61 scanner Qk 3/12/02 11:22 AM Page 11
1. Press either
or
For example,
select CHAIN 2.
CHAIN
2
• SCAN
1
4
2
5
8
0
3
6
during a search.
460.0000
MHZ
MHZ
SEARCH
• MANUAL
You must be
in search hold
before restoring all
skipped frequencies.
These
frequencies
were used during
“setting a search
range” on page 9.
CHAIN
2
7
9
SRCH SLCT
HOLD
CLEAR
460.5000
SEARCH
E
PRI
•
SKIP
L/O
LIGHT
WX
4. Press
SRCH
• SCAN
1
4
2
5
8
0
3
6
2. Press and hold
• SCAN
1
4
2
5
8
0
3
6
SKIP
for about
two seconds. You
will hear two
beeps when all the
frequencies have
been restored.
• MANUAL
• MANUAL
7
9
SRCH SLCT
HOLD
CLEAR
7
9
SRCH SLCT
HOLD
•
E
PRI
CLEAR
•
E
PI
SKIP
L/O
LIGHT
WX
SKIP
L/
LIGHT
WX
1
2
CHAIN
22
Storing Search Frequencies
You can quickly store any frequency you find during
search.
460.3875
MHZ
SEARCH
5. When the scanner
stops at the
frequency you
want, press
You must select the channel in which you
will store the frequency before entering the
• SCAN
1
4
2
3
6
search mode. Otherwise, you may erase a
stored frequency that you want to keep.
CAUTION
• MANUAL
5
8
0
either
or
7
9
SRCH SLCT
HOLD
•
MANUAL
1. Press
• SCAN
1
4
2
5
8
0
3
6
CLEAR
After this
step you
are in search hold
•
E
PRI
• MANUAL
SKIP
L/O
LIGHT
WX
7
9
SRCH SLCT
HOLD
mode.
Press
CLEAR
SRCH
to
1
2
CHAIN
•
E
PRI
resume searching.
SKIP
L/O
22
460.3625
MHZ
LIGHT
WX
HOLD
SEARCH
2. Select a channel.
a) Enter the
• SCAN
1
4
2
5
8
0
3
6
E
6. Press
store the
to
• SCAN
1
4
2
5
8
3
6
9
channel number.
b) Then press
• MANUAL
frequency in the
channel you
selected.
• MANUAL
•
MANUAL
7
9
SRCH SLCT
HOLD
CLEAR
again.
7
SRCH SLCT
HOLD
•
E
PRI
CLEAR
SKIP
L/O
•
0
E
LIGHT
WX
SKIP
L/O
1
2
CHAIN
LIGHT
WX
PRI
22
460.3875
MHZ
SEARCH
3. Select one or more
of the personal
search bands.
• SCAN
1
4
2
3
6
After this
step you are
in manual mode.
• MANUAL
22
460.3625
MHZ
5
8
0
HOLD
7
9
SRCH SLCT
HOLD
CLEAR
•
E
PRI
Repeat steps 2 through 6 for all the search
frequencies you want to store.
SKIP
L/O
LIGHT
WX
11
UBC61 scanner Qk 3/12/02 11:22 AM Page 12
Troubleshooting
If your UBC61XLT is not performing properly, try the following steps.
Problem
Suggestion
Improper reception
1. Check the antenna connection or move and reposition the antenna.
2. Move the scanner
3. You may be in a remote area which could require an optional multiband
antenna. Check with your dealer or local electronics store.
Scan won’t stop
1. Adjust squelch threshold - refer to page 5, setting the squelch.
2. Check the antenna connection.
3. Check to see if many of the channels are locked-out. If so, the scanner has
less chance of finding an active channel.
4. Review each channel’s frequency to see if it is still stored in memory and is correct.
5. It’s possible that none of the programmed frequencies are currently active.
SCAN
key again.
Scan won’t start.
1. Press the
2. Adjust the SQELCH control.
3. Check to see if all channels are locked out.
Weather Scan won’t work
1. Weather Scan is not functional in New Zealand or Australia.
Warranty
One Year Limited Warranty
Important: Evidence of original purchase is required for warranty service.
Warrantor: Uniden Australia Pty Limited A.B.N. 58 001 865 498
Uniden New Zealand Limited
ELEMENT OF WARRANTY: Uniden warrants to the original retail owner for the duration
of this warranty, its UBC 61XLT (herein after referred to as the Product), to be free from defects in materials and crafts-
manship with only the limitations or exclusions set out below.
WARRANTY DURATION: This warranty to the original retail owner only, shall terminate
and be of no further effect 12 months after the date of original retail sale. This warranty will
be deemed invalid if the product is; (A) Damaged or not maintained as reasonable and necessary, (B) Modified, altered or
used as part of any conversion kits, subassemblies, or any configurations not sold by Uniden, (C) Improperly installed,
(D) Repaired by someone other than an authorised Uniden Repair Agent for a defect or malfunction covered by this war-
ranty, (E) Used in conjunction with any equipment or parts or as part of a system not manufactured by Uniden, (F)
Warranty is only valid in original country of purchase.
PARTS COVERED: This warranty covers for one (1) year, the Base Unit and Handset only. All accessories (AC Adaptor,
Belt Clip etc)are covered for 90 days only.
STATEMENT OF REMEDY: In the event that the product does not conform to this warranty at any time while this warranty
is in effect, the warrantor at its discretion, will repair the defect or replace the product and return it to you without charge
for parts or service. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS GUARANTEE IS IN ADDITION TO AND DOES NOT IN ANY WAY
AFFECT YOUR RIGHTS UNDER THE CONSUMER GUARANTEE ACT.
PROCEDURE FOR OBTAINING PERFORMANCE OR WARRANTY: In the event that the product does not conform to this
warranty, the Product should be shipped or delivered, freight pre-paid, with evidence of original purchase (eg. a copy of
the sales docket), to the warrantor at:
UNIDEN AUSTRALIA PTY LIMITED
SERVICE DIVISION
UNIDEN NEW ZEALAND LIMITED
SERVICE DIVISION
345 Princes Highway,
150 Harris Road,
Rockdale NSW 2216
Ph (02) 9599 3355 Fx (02) 9599 3278
Toll Free 1300 366 895
East Tamaki, Auckland
Ph (9) 273 8383 Fx (9) 274 4253
Toll Free 0800 4 UNIDEN
4 864 336
Customers in other States should ship or deliver the Product freight pre-paid to their nearest Uniden Authorised Repair
Centre (Contact Uniden for the nearest Warranty Agent to you)
12
|