Turbo Air Refrigerator TCB 5R User Manual

 
INTRODUCTION  
This owner’s manual has important information. Please read the entire manual before  
installing your new Turbo Air Refrigerated Bakery Case.  
After reading manual if you have any questions, please fill free to call:  
CUSTOMER SERVICE DEPARTMENT  
TURBO AIR  
1250 VICTORIA ST.  
CARSON, CA 90746  
1-800-381-7770  
1-800-627-0032  
Please write down model and serial number for making any reference to this unit.  
CASE MODEL  
SERIAL NUMBER  
WARNING!  
Failure to read this manual completely can result in personal injury or damage to the unit.  
Keep manual in a safe place to refer to in the future.  
WARNING!  
Electrical must be installed by a licensed electrician.  
On page 6 and 16 is information for electrician.  
WARNING!  
All electrical wiring must be done in accordance with all applicable standards.  
Improper connections of electrical can result in death or severe injury.  
Thank you for purchasing Turbo Air!  
 
SAFETY STICKERS  
The following signs are thru out Turbo Air Bakery Case. If any are missing, Pleae  
call Customer Service so the sticker can be sent to you.  
DANGER HIGH VOLTAGE-This sticker is on back of bakery case.  
CAUTION-This sticker is below the Bakery display pan.  
! CAUTION-This sticker is on back of bakery case.  
Please follow all safety warnings on stickers. Make sure all employees understand  
warnings. Have all employees read manual for your and their safety.  
Please be sure person who installs Bakery Case understands safety warnings and  
has read manual.  
If service technician services unit make sure they understand safety warning on  
stickers. Please keep manual handy for future use for technician.  
All stickers are pleaced for your protection. Please never remove stickers. If stickers  
become lost or damaged call Customer Service so the stickers can be replaced.  
!!! When you see this symbol, please be alerted. This will be seen thru the manual  
and on stickers.  
WARNING!  
Please follow all instructions and all warnings for your safety.  
 
INSTALLATION INSTRUCTIONS  
INSPECTION FOR DAMAGE  
Customer is responsible for checking for damage. First inspect crate as soon sa it arrives. Prior  
to signing if crate is damaged make sure you note that on bill of lading.  
If after uncrating there is concealed damaged and crate was in good condition you must call  
Customer Service at Turbo Air. Concealed damage must be reported within 24 hours of receiving  
unit. Bill of lading will be requested faxed to claim department. Pictures may be requested of unit  
and crating.  
LOCATION OF BAKERY CASE  
Installation clearance:  
86 inch at the top, 20 inch at the rear and 12 inch at the each side.  
! CAUTION; Damage to case and glass can result if pushed on. Do not push curved  
glass, end glass, doors or door frames.  
Do not place Bakery Case in the following locations; near source of heat, excessive air movement,  
open doors, and direct sunlight.  
Move the bakery case to the final location before removing shipping skid.  
Condenser is in back of Bakery Case. Do not block inlet.  
LEVELING OF BAKERY CASE  
Four leveling legs are provided for leveling Bakery Case.  
Use a leveler to make sure unit is leveled on all four corners.  
If unit is not leveled drainage of water will not drain properly and doors will not close properly.  
Leveling legs can be adjusted accordingly.  
 
PACKAGING MATERIAL  
Remove all tape that holds lift up glass and doors in place. Some residue will be left and  
this can be removed with glass cleaner.  
Remove all plastic ties that hold shelves and brackets for shelves.  
LIGHTS  
Make sure lights are in their lamp holders. Also make sure plugs for lamp holders are  
completely plugged in. If they are loose it may cause lamp holder to burn.  
SHELVES  
To install shelves in desired position front glass must be open and rear doors removed.  
Remove doors by lifting upwards and then out of bottom track one at a time. Put doors in  
a safe location. Lift front glass upwards till fully open.  
Where shelf height is desired install the shelf support in shelf standard slot (see drawing)  
Install shelves on rear shelf support as shown. Curved part of shelf must be toward rear  
of case if not air flow will be blocked. Snap shelf into retainer clip on the shelf support,  
this keeps shelf from moving (see drawing)  
After installing all shelves close front glass and reinstall doors.  
 
ELECTRICAL INFORMATION  
!!! BAKERY CASE MUST BE GROUNDED  
Only a licensed electrician must install all electrical on Bakery Case.  
All electrical must be done in accordance with applicable electrical standards.  
A dedicated breaker is to be used for each Bakery Case.  
Electrical must be grounded upon installation  
An access hole is provided thru base of case for running electrical up through floor. Also  
a hole is provided in the back of unit to run electrical. Unit is designed to be hardwired  
by electrician. Electrical data is located next to electrical junction box (see drawing)  
The Bakery Case comes with a power with a power cord. Cord is 9.8 feet long. The plug is a  
.
!!! Improper electrical connections can result in servere injury or death.  
!!! Do not operate Bakery Case with panels or grill removed.  
There are two back panels.  
Right side panel has light switch, power switch, thermostat, and thermometer. Also  
compressor service ports, electrical condensate drain pan, fuses, and main board are  
accessible.  
Left side panel allows access to electrical connection box, ballast, and also allows  
condenser unit to be pulled out.  
Front panel is removable to have access to fans.  
 
WIRING DIAGRAM(TCB-5R)  
 
OPERATING INSTRUCTIONS  
After installing unit and all electrical to Bakery Case, unit is ready to start up.  
CONTROLS  
POWER SWITCH:It is labeled with on/off position. It controls power to the entire  
Bakery Case.  
LIGHT SWITCH  
:
The switch controls the power to the lighting circuit.  
The switch rocker is red in the “on” position, black in the “off” position.  
TEMPERATURE CONTROL  
:
TCB-5R  
1. The controller(thermostat) is locatef at the right inside of the unit.  
2. The factory setting for the control is Normal  
3. To lower temperature, depress down button to incrase temperature, depress up button  
4. This product is for controlling temperature from 38 to 55ᵻ  
5. The thermostat controls compressor’s on/off by sensing inside temperature.  
THERMOMETER  
:
Display changes temperature approximately every two seconds.  
NOTE  
:
Before placing goods to Bakery Case wait for unit to reach desired temperature. Product  
must be cold before placing in Bakery Case.  
ANTI MOISTURE FANS:These fans run continuously when power switch is on. Two  
fans are at the front bottom of unit. The fans blew warm air through vents and prevent  
front glass from getting moisture. Do not block vents because front glass will get moisture.  
HOW TO PLACE PRODUCT:Check that display pans are positioned correctly before  
placing goods in Bakery Case(see drawing). Do not overstock shelves. Display pans  
should not hang over shelf. This will cause pan to block air flow and Bakery Case will  
warm up in temperature. This will cause product to spoil.  
 
SHELF PLACEMENT  
:
The shelves can be installed slanted or straight. To make the shelf slanted do the following;  
a. Shelf needs to be removed from shelf support.  
b. Shelf support needs to be held at each end.  
c. Shelf support needs to be lifted at the back till bracket can inserted into shelf standard slots.  
Refer to drawing of pages 5.  
ADJUSTING SHELF LEVEL  
Shelves can be sdjusted up or down. To move shelves do the following;  
a. Lights must be turned off.  
b. Grasp plug for light cord and unplug.  
c. Shelves must be removed from shelf support.  
d. Hold onto each end of shelf support.  
e. Shelf support needs to be moved up until it can removed from shelf standard.  
f. Shelf can be repositioned in increments of two inches.  
REPLACEMENT OF LIGHT  
When replacing lights use same model of light installed in Bakery Case. Using wrong  
wattage can cause ballast to burn out or light not work.  
To remove light there is two lamp holders one at each end of light. One has a spring in  
socket. Push light toward spring loaded lamp holder till other end of light pops out of  
other lamp holder.  
Remove light from lamp shield and insert new light into lamp shield. Reinsert into lamp  
holders. Never install lamp without shield.  
 
FRONT CURVED GLASS  
!!!WARNING  
The Bakery Case is not intended for self serve. Do not let customers lift front glass.  
Only trained personnel should lift curved glass.  
Under normal use hinges will last many years. If any of the following problems occur,  
plase call Customer Service;  
a. Front curved glass closes rapidly.  
b. Front curves glass does not open easily.  
c. Front curved glass does not stay open, when in the opened position.  
 
MAINTENANCE & CLEANING  
!!! Always before cleaning Bakery Case unit should be turned off at power switch and lights  
should be turmed off. Removed product and allow display to reach room temperature.  
!!! Do not wet electrical components.  
BAKERY CASE SHOULD BE CLEANED THOROUGHLY BEFORE FIRST USE.  
CLEANING DAILY  
a. Do not clean with detergents. Use a mild soap.  
b. If door track is dirty remove doors. Keeping door track clean allows for doors to slide  
easily. Food silicone can be sprayed on rollers and track.  
c. Clean glass with window cleaner.  
d. Exterior and interior can be cleaned with warm water and mild detergent.  
e. Wipe with damp cloth. Do not leave residue of soap.  
CLEANING WEEKLY  
This procedure is necessary to keep a sanitized Bakery Case. Procedure may have to be done  
more than once a week if necessary.  
EXTERIOR CLEANING  
a. Clean front glass with window cleaner.  
b. Clean exterior with warm soapy water. Wipe down with damp cloth.  
INTERIOR CLEANING  
a. Remove both doors by lifting up and out.  
b. Raise front curved glass all the way up.  
c. Grasp plug for light cord and unplug.  
d. Remove shelves.  
e. Remove shelf support from shelf standard slots.  
f. Remove both thumb screws holding shelf standard and removed shelf standards.  
g. Remove display pans.  
h. Wash all parts with warm soapy water and rinse. Allow to dry.  
i. Clean inside of unit with warm soapy water. Wipe down with damp cloth. Allow to dry.  
j. Put unit back together in reverse order starting with step.  
 
MAINTENANCE CONTINUED  
CONDENSER COIL  
a. Turn off unit at power switch. Disconnect power to unit.  
b. Remove rear grill.  
c. Clean condenser by either brushing off with stiff wire brush or vacuuming with  
wet/dry vacuum. Condenser is black and looks like a radiator. This should be  
cleaned every month or as necessary. Keeping clean allows for maximum cooling  
of unit and long life of compressor.  
 
TROUBLE SHOOTING  
For any problems with BAKERY-Case please refer to following check list. If still having a  
problem or need to ask a question please call Customer Service at 1-800-381-7770 or  
1-800-627-0032  
BAKERY CASE NOT WORKING  
a. Check to see if breaker is not tripped.  
b. Check power gowing to unit.  
c. Check thermostat is set at on position.  
d. Check power switch is on.  
BAKERY CASE WARM  
a. Check condenser to see if clean.  
b. Check that doors and curved glass are closed tightly.  
c. Check that shelves are installed properly.  
d. Check that air flow inside of unit is not blocked with product or pans.  
e. Check that evaporator coil does not have frost build up. If doors are left open frost  
will accumulate. To defrost turn off thermostat about one hour to melt off frost.  
Evaporator coil comes with thermostat for antifreeze.  
GLASS SWEATING  
a. Check that there is nothing on top of curved glass.  
b. Check to see that there are no overhead vents, air ducts, or fans.  
c. Check temperature of room. Bakery Case is designed to operate in an ambient  
temperature of 75 degrees Fahrenheit and 55% relative humidity.  
d. Check temperature of Bakery Case. Unit should be between 38 and 42 degrees.  
e. Check that air is flowing inside front of Bakery Case. If there is no air flow or air  
is felt on only one side this is due to anti moisture fans are not working. Customer  
Service needs to be called.  
LIGHTS NOT WORKING  
a. Check that light switch is on.  
b. Check that lamp cord is plugged in correctly.  
c. Check that light is in lamp holder correctly.  
 
WARRANTY STATEMENT  
WARRANTY CLAIMS  
All claims for parts or labor must be made directly through Turbo Air.  
All claims should include : model number of the unit, the serial number of the cabinet, proof of  
purchase, date of installation, and all pertinent information supporting the alleged defect.  
In case of compressor replacement under warranty, either compressor or compressor tag must be  
returned to Turbo Air along with above listed information.  
Failure to comply with warranty policies will result in voiding claims.  
ONE YEAR PARTS & LABOR WARRANTY  
Turbo Air warrants all new refrigerated components, the cabinet and all parts, to be free from defects  
in materials or workmanship, under normal and proper use and maintenance service as specified by  
Turbo Air and upon proper installation and start-up in accordance with the instruction packet supplied  
with each Turbo Air unit. Turbo Air's obligation under this warranty is limited to a period of one (1)  
year from the date of original installation or 15 months after shipment date from Turbo Air,  
whichever occurs first.  
Any part, covered under this warrant, that are determined by Turbo Air to have been defective within  
one (1) year of original installation or fifteen (15) months after shipment date from manufacturer,  
whichever occurs first, is limited to the repair or replacement, including labor charges, of defective  
parts or assemblies. The labor warranty shall include standard straight time labor charges only and  
reasonable travel time, as determined by Turbo Air.  
ADDITIONAL FOUR YEAR COMPRESSOR WARRANTY  
In addition to the one (1) year warranty stated above, Turbo Air warrants its hermetically sealed  
compressor to be free from defects in both material and workmanship under normal and proper use  
and maintenance service for a period of four (4) additional year from the date of original installation,  
but not to exceed five (5) years and three (3) months after shipment from the manufacturer.  
Compressor determined by Turbo Air to have been defective within this extended period will, at  
Turbo Air's discretion, be either repaired or replaced with a compressor or compressor parts of similar  
design and capacity.  
The four (4) year extended compressor warranty applies only to hermetically sealed parts of the  
compressor and does not apply to any other parts or components, including, but not limited to,  
cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting  
equipment, fan assembly or and other electrical components, etcetera.  
404A/134A COMPRESSOR WARRANTY  
The four-year compressor warranty detailed above will be void if the following procedure is not  
carefully adhered to :  
1. This system contains R404A or R134A refrigerant and polyol ester lubricant. The polyol ester  
lubricant has rapid moisture absorbing qualities.  
2. Drier replacement is very important and must be changed when a system is opened for servicing.  
A620 copper drier or better is highly recommended.  
3. Micron level vacuums must be achieved to insure low moisture levels in the system. 500 microns  
or lower must be obtained.  
4. When compressor is grounded, suction drier and 620 drer or better must be replaced.  
5. Compressor must be obtained through Turbo Air, unless otherwise specified in writing, through  
Turbo Air's warranty department.  
 
WHAT IS NOT COVERED BY THIS WARRANTY  
Turbo Air's sole obligation under this warranty is limited to either repair or replacement of parts,  
subject to the additional limitations below. This warranty neither assumes nor authorizes any person  
to assume obligations other than those expressly covered by this warranty.  
NO CONSEQUENTIAL DAMAGES. TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC  
LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES,  
INCLUDING WITHOUT LIMITATION, LOSSES, OR DAMAGES ARISING FROM FOOD OR  
PRODUCT SPOILAGE REGARDLESS OF WHETHER OR NOT THEY RESULT FROM  
REFRIGERATION FAILURE. WARRANTY IS NOT TRANSFERABLE. This warranty is not  
assignable and applies only in favor of the original purchaser / user to whom delivered. ANY SUCH  
ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN AND SHALL  
VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF  
MERCHANTABILITY OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER  
THE WARRANTY PACKET PROVIDED WITH THE UNIT.  
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR  
INSTALLATION, FIRE, FOOD, ACTS OF GOD. Turbo Air is not responsible for the repair or  
replacement of any parts that Turbo Air determines have been subjected after the date of manufacture  
to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or act  
of GOD.  
IMPROPER ELECTRICAL CONNECTIONS. TURBO AIR IS NOT RESPONSIBLE FOR THE  
REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING  
FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION CORDS, LOW  
VOLTAGE, OR VOLTAGE DROPS TO THE UNIT. NO IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE : THERE ARE NO  
OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE ONE (1)  
YEAR PARTS & LABOR WARRANTY AND THE ADDITIONAL FOUR (4) YEAR  
COMPRESSOR WARRANTY AS DESCRIBED ABOVE. THESE WARRANTIES ARE  
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED  
WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
THERE ARE NO WARRANTIES, WHICH EXTEND BEYOND THE DESCRIPTION ON THE  
FACE HEREOF.  
Outside U.S. and Canada : This warranty does not apply to, and Turbo Air is not responsible for, any  
warranty claims made on products sold or used outside the continent of the United States and Canada.  
CHANGES MADE TO WARRANTY COMMENCED ON 11/01/2007  
1250 Victoria street  
Carson, CA 90746  
U.S.A & Canada Toll Free 1-800-627-0032  
For Service 1-800-381-7770  
TEL : 310-900-1000  
FAX : 310-900-1077  
 
 
 
 
 

Tech Craft TV Video Accessories BCE72 User Manual
Technicolor Thomson DVD Player DTH210E User Manual
Texas Instruments Computer Hardware MSP430x4xx User Manual
Traulsen Refrigerator RHT232NUT FHS User Manual
UltraViolet Devices Indoor Furnishings UVA User Manual
UMAX Technologies Scanner 2000U P User Manual
Velodyne Acoustics Car Speaker SC 10 User Manual
Vermont Casting Gas Grill VM400 User Manual
Vidikron Projection Television Vision 100t User Manual
ViewSonic Laptop VS12638 User Manual