Traulsen Refrigerator UC27HT User Manual

Quality Refrigeration  
OWNER’S MANUAL  
Instructions for the installation, operation  
and maintenance of all Traulsen Spacesaver Models:  
Refrigerator Models: UR30HT, UR48HT, UC27HT  
Freezer Model: UR30LT  
Refrigerator/Freezer Model: UR48DT  
Wine Cabinets: UR30WT, UR48WT, UC27WT  
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers and heated  
cabinets this way as a matter of pride. This philosophy has made Traulsen the leader in commercial refrig-  
eration since 1938. We thank you for your choice and confidence in Traulsen equipment and we know you  
will receive many years of utility from this equipment.  
All Traulsen units are placed on a permanent record file with the service department. In the event of any  
future questions you may have, please refer to the model and serial number found on the name tag affixed  
to the unit. Should you need service, however, call us on our toll free number, 800-825-8220 between 7:30  
am and 4:30 pm CST, Monday thru Friday. It is our pleasure to help and assist you in every possible way.  
INSTALLER  
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION  
INITIAL START DATE:  
MODEL TYPE:  
SERIAL NO.  
COMPANY/INDIVIDUAL NAME:  
INSTALLER:  
FORM NUMBER TR35749 REV. 5/03  
P/N 375-60177-00  
 
II. RECEIPT INSPECTION  
III. INSTALLATION (continued)  
All Traulsen products are factory tested for perfor-  
mance and are free from defects when shipped. The  
utmost care has been taken in crating this product to  
protect against damage in transit. All interior fittings  
have been carefully secured and the legs or casters  
and bottom mounted condensate evaporator are boxed  
and strapped inside to prevent damage. If the unit is  
equipped with optional locks the door keys will be at-  
tached to the handle with a nylon strip. The handle is  
protected by an easily removable nylon netting.  
III. c - INSTALLING LEGS OR CASTERS:  
6high stainless steel legs are supplied standard for  
all Traulsen Spacesaver units. Casters in lieu of legs  
are available as an optional accessory for the same  
models. These are shipped from the factory packed  
inside a cardboard box which is strapped to one of  
the shelves. Remove the nylon strap and open the  
box, it should contain either four (4) legs or four (4)  
casters and sixteen (16) bolts.  
WARNING: THE CABINET MUST BE BLOCKED AND  
STABLE BEFORE INSTALLING LEGS OR CASTERS.  
You should carefully inspect your Traulsen unit for  
damage during delivery. If damage is detected, you  
should save all the crating materials and make note  
on the carriers Bill Of Lading describing this. Afreight  
claim should be filed immediately. If damage is sub-  
sequently noted during or immediately after installa-  
tion, contact the respective carrier and file a freight  
claim. Under no condition may a damaged unit be re-  
turned to Traulsen & Co. without first obtaining writ-  
ten permission (return authorization).  
To install the legs or casters, first raise and block the  
unit a minimum of 7from the floor. For installing  
legs, thread the legs into the threaded holes on the  
bottom of the cabinet (see figure 1). Be certain that all  
legs are tightly secured (legs and casters should be  
tightened to 300 inch/pounds, max). When the unit is  
set in its final position, it is important for proper op-  
eration that the unit be level. The legs are adjustable  
for this purpose, turn the bottom of the leg counter-  
clockwise to raise it, clockwise to lower it. Level the  
unit from front to back as well as side to side in this  
manner, using a level placed in the bottom of the cabi-  
net.  
III. INSTALLATION  
III. a - LOCATION:  
Select a proper location for your Traulsen Spacesaver  
unit, away from extreme heat or cold. Allow enough  
clearance between the unit and the side wall so that  
the door (s) may open a minimum of 90°.  
III. b - PACKAGING:  
All Traulsen Spacesaver units are shipped from the  
factory bolted to a sturdy wooden pallet and packaged  
in a durable cardboard container. The carton is at-  
tached to the wooden skid with the use of large staples.  
These should first be removed to avoid scratching the  
unit when lifting off the crate.  
Fig. 1  
Please note that Traulsen Spacesaver units are not de-  
signed to be moved while on legs. If the unit requires  
moving, a pallet jack or forklift should be used to pre-  
vent damage. For installing casters, the casters are  
platetype, and require the use of four (4) bolts each  
to secure them firmly to the cabinet bottom at each  
corner (see figure 2). The caster bolts are tightened  
using a 1/2socket wrench.  
To remove the wooden pallet, first if at all possible, we  
suggest that the cabinet remain bolted to the pallet  
during all transportation to the point of final installa-  
tion. The bolts can then be removed with a 3/4socket  
wrench. Avoid laying the unit on its front, side or  
back for removal of the pallet.  
All exterior metal surfaces are protected from scratch-  
ing during manufacturing and shipping by a plastic  
covering. This should be removed prior to installa-  
tion.  
Figure 2  
NOTE: Traulsen does not recommend laying the unit  
down on its front, side or back. However, if you must  
please be certain to allow the unit to remain in an up-  
right position afterwards for 24 hours before plugging  
it in so that the compressor oils and refrigerant may  
settle.  
-2-  
 
III. INSTALLATION (continued)  
III. f - REMOTE INSTALLATION:  
III. d - SHELF PINS:  
Remote models are supplied without compressors,  
solenoid valves, etc. The correct voltage, amp listing,  
refrigerant and BTU’s are listed on the unit’s serial tag.  
It is the responsibility of the installer to specify and  
supply the correct size compressor(s) based upon this  
information and on-site requirements. Refrigerant line  
installation must be done in adhering to good prac-  
tice and local regulations. See section III. efor in-  
formation concerning condensate removal for remote  
models.  
The unit is supplied with shelves and shelf pins in-  
stalled. Check all shelf pins to assure they are tight-  
ened down as they may have come loose during ship-  
ping. Rotate the pins clockwise until they are secured  
against the side of the cabinet.  
III. e - INSTALLING THE CONDENSATE EVAPORATOR:  
A bottom-mounted electric condensate evaporator is  
normally supplied on all self-contained models. This  
is shipped in a cardboard carton secured to the cabi-  
net interior, and must be installed prior to use.  
III. g - CORD & PLUG:  
Most self-contained models are supplied with a cord  
& plug attached. It is shipped coiled at the top of the  
cabinet, secured by a nylon strip. For your safety and  
protection, all units supplied with a cord and plug in-  
clude a special three-prong grounding plug on the ser-  
vice cord. Select only a dedicated electrical outlet with  
grounding plug for power source. NOTE: Do not un-  
der any circumstances, cut or remove the round  
grounding prong from the plug, or use an extension  
cord.  
To install a bottom-mounted electric condensate  
evaporator (see figure 3).  
After the cabinet has been uncrated and the legs/cast-  
ers attached, locate the four (4) holes on the exterior  
bottom towards the rear of the cabinet. Then, using  
the four (4) screws provided, attach the mounting rails  
to the cabinet bottom (the end flange is to be up and  
be facing towards the cabinet rear). Next, place the  
heater into the heater bracket (note the enclosed  
springs are only to be used when the heater is placed  
on the floor). Slide heater and bracket into the mount-  
ing rails. Plug the supplied cord into both the heater  
on one end, and the electrical outlet, provided on the  
cabinet exterior bottom towards the front, on the other.  
Screw the U-Trap(UR30LT only) or 90 degree elbow  
joint (all other Spacesaver models) into the drain line  
located on the rear of the cabinet and then screw the  
drain extension into the U-Trap or elbow joint.  
III. h - POWER SUPPLY:  
It is recommended that the supply voltage be checked  
prior to connection to be certain that proper voltage  
for the cabinet wiring is available (refer to the serial  
tag to determine correct unit voltage). Make connec-  
tions in accordance with local electrical codes. Use  
qualified electricians.  
Use of a separate, dedicated circuit is recommended.  
Size wiring to handle indicated load and provide nec-  
essary overcurrent protector in circuit.  
Drain  
Line  
III. i - WIRING DIAGRAM:  
U-Trap  
Refer to the wiring diagram for any service work per-  
formed on the unit. Should you require one, please  
contact Traulsen Service at (800) 825-8220, and pro-  
vide the model and serial number of the unit involved.  
Electric  
Heater  
Drain  
Extension  
10-32 x 3/8 Screw (4)  
Mounting Rails  
BMCE  
III. j - CLEARANCE:  
Receptacle  
In order to assure optimum performance, the condens-  
ing unit of your Traulsen unit MUST have an adequate  
supply of air for cooling purposes. Therefore, the  
operating location must either have a minimum of 12”  
clearance overhead of the condensing unit or allow  
for unrestricted air flow at the back of the unit. Clear-  
ance of at least 12above is required in order to per-  
form certain maintenance tasks.  
Heater  
Bracket  
Figure 3  
A remote model is normally configured for conden-  
sate to be run to a floor drain unless purchased with a  
condensate evaporator. The installer is responsible  
for making the required extension to the floor drain in  
accordance with good practice and local regulations.  
The bottom mounted electric condensate evaporator  
of your Traulsen Spacesaver should be cleaned occa-  
sionally to keep it clear of dirt and debris.  
-3-  
 
III. INSTALLATION (continued)  
III. k - BUILT-IN INSTALLATION:  
Select a proper location for your unit away from ex-  
treme heat or cold. Due to the unique air flow of the  
unit, the Spacesaver can be built-in or used as a free-  
standing unit. Allow enough clearance between the  
unit and side wall so that the doors can be opened a  
minimum of 90 degrees. The floor should be level,  
firm and capable of supporting the weight of the fully  
loaded unit.  
Traulsen  
Follow the typical installation instructions outlined in  
Section III. athru III. jas required.  
All built-in units require a minimum of 1/2clearance  
around the cabinet for servicing (see figure 5). If top  
clearance exceeds 1the unit must be blocked per  
the free-standing instructions of Figure 6.  
NOTE: If a self-contained unit is to be installed com-  
pletely recessed, the front louvers must NOT be  
blocked or replaced with a solid panel. The front lou-  
vers allow good air circulation in the compressor com-  
partment.  
BMCE  
49  
Fig. 4 - Front View  
Model UR48DT  
Showing Minimum Built-In Clearances  
BLOCK  
(one in each corner)  
1/2  
MIN.  
L
L
O
U
V
E
R
S
O
U
V
E
R
S
Fig. 6  
Fig. 5  
Side View  
Model UR48DT  
Showing Built-In Installation  
Side View  
Model UR48DT  
Showing Free-Standing Installation  
-4-  
 
III. INSTALLATION (continued)  
III. l - ELECTRICAL OUTLET INSTALLATION:  
Refer to the diagram below to determine the correct location for the electrical outlet for built-in units.  
348”  
Electrical Outlet  
Installation  
For Model UR48DT  
6”  
49”  
Wall Opening  
NOTE: Wall location of electrical outlet for built-in units and applications that require unit to be counter top  
depth, locate outlet in shaded area only.  
IV. MISCELLANEOUS PRODUCT FEATURES  
IV. a - SOLAR DIGITAL THERMOMETER:  
All Spacesaver models are equipped with an external  
solar digital thermometer. It has an LED display and  
is mounted on the top, left side of the cabinet next to  
the louvers.  
IV. b - LIGHT SWITCHES (contd):  
ated red switch is included for manual light control.  
Typically this feature is used for units supplied with  
glass doors. In the ON position, the lights are illumi-  
nated whether the doors are open or not. In the OFF  
position, the lights are controlled by the hinge switch  
as described in the first paragraph.  
Thermometers on older Spacesaver models also in-  
cluded a battery back-up for use in low-light condi-  
tions. Prolonged use of this in low-light conditions  
could result in exhausting the battery. To replace the  
battery back-up, lift-up the louver assembly as out-  
lined in section V. a. Next, remove the screws secur-  
ing the thermometer housing cover and replace the  
battery.  
IV. c - DEFOGGER CONTROL:  
As environmental conditions vary, condensation may  
appear on the front of your Spacesaver around the  
doors. To control this, Traulsen has included a manual  
defogger switch, which is mounted on the top, left side  
of the cabinet next to the louvers, below the thermom-  
eter.  
IV. b - LIGHT SWITCHES:  
All Spacesaver models include a concealed light  
switch mounted in the top door hinge(s), which auto-  
matically activates the interior light when the door is  
opened. When the door is closed, the lights are not  
operating. In addition, an exterior mounted, illumin-  
When in the ON position, anti-condensate heaters  
around the door perimeter are activated which help to  
evaporate any condensation, and prevent it from re-  
curring. This can be turned OFF when not needed in  
order to save energy.  
-5-  
 
V. OPERATION  
VI. CARE & MAINTENANCE  
V. a - ADJUSTING THE TEMPERATURE:  
VI. a - CLEANING THE CONDENSER:  
The refrigeration system has been properly charged  
and tested at the factory. Plug the unit into the power  
outlet to determine if the compressor(s) is running. If  
not, check the ON/OFFswitches behind the louver  
assembly. On a refrigerator/freezer models (UR48DT)  
there are separate switches for each compartment (lo-  
cated on the right side) and both must be in the ON  
position.  
The most important thing you can do to insure a long,  
reliable service life for your Traulsen is to regularly  
clean the condenser coil.  
The condensing unit requires regularly scheduled  
cleaning to keep the finned condenser clean of lint  
and dust accumulation. The frequency of cleaning  
will depend on jobsite conditions, however at least  
once a month is strongly recommended. Keeping the  
condenser clean allows the cabinet to operate more  
efficiently and use less energy.  
If, after determining that your Spacesaver unit is func-  
tioning, and has had adequate time to pull-down tem-  
perature, the temperature is above/below standard  
ranges (34 to 38° F for refrigerators, 0 to -5° F for freez-  
ers), adjust the temperature controls. This is a black  
knob located behind the louver assembly along the  
centerline. It can be adjusted up or down one number  
at a time to raise or lower temperature.  
To clean the condenser, first disconnect electrical  
power to the cabinet and lift up the front louver as-  
sembly. To lift this, remove the two screws located on  
both sides at the bottom of the louver assembly (see  
figure 7). Once the screws are removed, the panel  
can be pivoted upwards allowing full access to the  
front facing condenser (see figure 8). Vacuum or  
brush any dirt, lint or dust from the finned condenser  
coil, the compressor and other cooling system parts.  
If significant dirt is clogging the condenser fins, use  
compressed air to blow this clear. Care should be  
taken not to bend any of the condenser fins, as this  
will reduce performance and compressor life.  
Fig. 7  
Remove  
Screws  
Lower louver assembly and replace the screws to hold  
it in place.  
VI. b - HINGE REPLACEMENT:  
Both the door and hinge can be easily removed from  
the cabinet. To remove the door, remove the screw at  
the bottom of the upper hinge. Inside the upper hinge  
there is a small pin screw which secures the door in  
place. Remove this with a flat head screwdriver and  
the door can then be lifted off the hinge. To remove  
the door-half of the hinge from the door, slide hinge  
cover downward and then remove the three Phillips  
head screws which secure the hinge in place on the  
door.  
Fig. 8  
Lift-Up Louver  
Assembly  
To remove the cabinet-half of the hinge, remove the  
three Phillips head screws which hold it in place. On  
all units, the top hinge(s) contains a microswitch for  
controlling the interior lighting.  
V. b - AUTOMATIC DEFROST:  
The refrigerator section operates on a “cycle defrost”  
basis, which means, at the end of each refrigeration  
cycle, the coil is allowed to reach 42° F and defrost  
itself. This method allows for maximum efficiency of  
the refrigeration system.  
To reassemble the hinge reverse the previous proce-  
dure.  
VI. c - REPLACING THE GASKETS:  
The freezer section is normally frost free and never  
requires a manual defrost. When the defrost system is  
operating, the compressor and fans do not run.  
To remove the gasket to be replaced, grasp it firmly  
by one corner and pull it out. Before attempting to  
install a new gasket, both the unit and the gasket it-  
self must be at room temperature. Insert the four cor-  
ners first by using a rubber mallet (or hammer with a  
block of wood). After the corners are properly inserted,  
work your way towards the center from both ends by  
WARNING: DISCONNECT ELECTRICAL POWER  
SUPPLY BEFORE CLEANING ANY PARTS OF THE  
UNIT.  
-6-  
 
VI. CARE & MAINTENANCE (contd)  
VII. MISC. OPERATIONS  
VI. c - REPLACING THE GASKETS (contd):  
VII. a - ADJUSTING THE SHELVES:  
gently hitting with a mallet until the gasket is com-  
pletely seated in place (see figure 9 for proper gasket  
For shelves mounted on pins, first select the desired  
location and remove the white plastic covers in the  
interior back and sides by rotating them counter-clock-  
wise. Next, remove the existing shelf pins by rotating  
them counter-clockwise. Install the pins in the desired  
location and tighten by rotating clockwise. Make sure  
the pin is securely tightened down, don’t over tighten.  
Slide the shelf into its new position. Replace the white  
plastic covers into the holes vacated by the shelf pins.  
placement).  
Inside Door Panel  
Gasket Assembly  
Fig. 9  
Vertical Gasket  
Retainer  
VII. b - REMOVING THE DRAWER PANS:  
For your convenience, each drawer contains two (2)  
removable anodized aluminum pans. They can be re-  
moved for cleaning simply by opening the drawer and  
lifting them out.  
NOTE: The gasket may appear too large, but if it is  
installed as indicated above it will slip into place.  
VI. d - CLEANING THE EXTERIOR:  
VII. c - REMOVING THE DRAWERS:  
Exterior stainless steel should be cleaned with warm  
water, mild soap and a soft cloth. Apply with a damp-  
ened cloth and wipe in the direction of the metal grain.  
Prior to removing the drawers, food and pans should  
be removed. The drawer is heavy and care should be  
taken to keep feet clear. To remove, pull the drawer  
out as far as possible. Then, lift the drawer and con-  
tinue to pull until the drawer is free of the unit. To  
replace, simply reverse the process.  
Avoid the use of strong detergents and gritty, abra-  
sive cleaners as they may tend to mar and scratch the  
surface. Do NOT use cleansers containing chlorine,  
this may promote corrosion of the stainless steel.  
VIII. OTHER  
VIII. a - SERVICE INFORMATION:  
Care should also be taken to avoid splashing the unit  
with water, containing chlorinated cleansers, when  
mopping the floor around the unit.  
Before calling for service, please check the following:  
Is the electrical cord plugged in?  
Is the fuse OK or circuit breaker on?  
Is the power switch ON?  
For stubborn odor spills, use baking soda and water  
(mixed to a 1 TBSP baking soda to 1 pint water ratio).  
VI. e - CLEANING THE INTERIOR:  
For cleaning both stainless steel and anodized alumi-  
num interiors, the use of baking soda as described  
above is recommended. Use on breaker strips and as  
well as door gaskets. All interior fittings are remov-  
able without tools to facilitate cleaning.  
If there is no air movement in the freezer unit, it  
may be in defrost cycle. Wait 35 minutes to  
see if the unit will restart.  
Do the lights work?  
VI. f - REPLACING THE INTERIOR LIGHT BULB:  
Turn the unit OFF (the ON/OFF switch is located be-  
hind the top louver panel). Next, remove the light cover  
by squeezing the sides together, which releases the  
tabs from the holding slots. Replace the burned out  
light bulb with a similar type appliance bulb.  
If after checking the above items and the unit is still  
not operating properly, please contact an authorized  
Traulsen service agent. A complete list of authorized  
service agents was provided along with your Traulsen  
unit. If you cannot locate this, you may also obtain the  
name of a service agent from the Tech Service page of  
To replace the light cover, squeeze the sides together  
and reinsert tabs in to the holding slots and release to  
lock in place.  
If service is not satisfactory, please contact our in-  
house service department at:  
Traulsen & Co., Inc.  
4401 Blue Mound Road  
Fort Worth, TX 76106  
(800) 825-8220  
Traulsen & Co., Inc. reserves the right to change speci-  
fications or discontinue models without notice.  
-7-  
 
VIII. OTHER (contd)  
VIII. b - SPARE PARTS:  
Spare or replacement parts may be obtained through  
a parts supplier or one of our authorized service  
agents. A complete list of authorized service agents  
accompanies this manual and is also posted on our  
VIII. c - WARRANTY REGISTRATION:  
For your convenience, the warranties on your new  
Traulsen unit may be registered with us by one of two  
methods. Completing the enclosed warranty card  
(shipped with the unit), or by filling out the on-line  
warranty registration form located on the Technical  
Service page of our website (www.traulsen.com).  
IX. TROUBLE SHOOTING GUIDE  
FIND YOUR PROBLEM HERE  
REMEDY  
1. Condensing unit fails to start.  
a.  
b.  
Check if line has been disconnected.  
Check switch behind louvers.  
2. Condensing unit operates for  
prolonged periods or continuously.  
a.  
b.  
c.  
Are doors closing properly?  
Dirty condenser or filter. Clean properly.  
Evaporator coil iced. Needs to defrost.  
3. Food compartment is too warm.  
a.  
Thermostat setting too high, readjust  
thermostat.  
b.  
c.  
Check door gasket for proper seal.  
Frequent door openings, allow adequate recovery  
time.  
d.  
Perhaps a large quantity of food has  
recently been added or the door was kept  
open for a long period of time, in both  
cases, allow adequate time for the cabinet  
to recover its normal operating temperature.  
4. Food compartment is too cold.  
a.  
Adjust the thermostat to a warmer  
setting.  
5. Condensation on the exterior surface.  
a.  
b.  
Condensation on the exterior surface of the  
unit is perfectly normal during periods of  
high humidity. Turn on the defogger switch.  
Check door alignment and gaskets for  
proper seal.  
6. Compressor hums but does not start.  
7. Light bulb is not functioning.  
a.  
Call service.  
a.  
b.  
Check if light bulb is burned out.  
Check to see if light switch is on (if applicable).  
-8-  
 
X. WARRANTY INFORMATION  
STANDARD DOMESTIC WARRANTY  
TRAULSEN & CO., INC. warrants new equipment to the original purchaser, when installed within the  
United States against defective material and workmanship for one (1) year from the date of original  
installation. Under this warranty, TRAULSEN & CO., INC. will repair or replace, at its option, including  
service and labor, all parts found to be defective and subject to this warranty. The compressor part is  
warranted for an additional four (4) years. During this period TRAULSEN & CO., INC. will supply re-  
placement compressor(s) if deemed defective, however, all installation, recharging and repair costs  
will remain the responsibility of the owner.  
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse,  
transit, acts of God, attempted repairs, improper installation by unauthorized persons, and will not  
apply to food loss.  
THEREARE NO ORAL, STATUTORY OR IMPLIED WARRANTIESAPPLICABLE TO TRAULSEN, INCLUD-  
ING BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY  
PARTICULAR PURPOSE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.  
TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL OR SPECIAL DAM-  
AGES, GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE, OPERATION OR  
USE, AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT  
ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE, OPERATION  
OR USE OTHER THAN AS STATED HEREIN.  
INTERNATIONAL COMMERCIAL WARRANTY  
(for Canadian warranties see domestic US warranty)  
TRAULSEN & CO., INC. warrants to the original purchaser the Refrigeration Equipment manufactured and  
sold by it to be free from defects in material and workmanship under normal use and service for a period of  
one (1) year from date of shipment. Under this warranty, TRAULSEN & CO., INC. will reimburse the pur-  
chaser for the replacement of any part of said equipment (excluding dryers & refrigerant gas) which then  
proves to be defective. This warranty is void if said equipment or any part thereof has been subject to misuse,  
damage in transit, accident, negligence or alteration.  
TRAULSENS standard warranty does not apply to Export Sales. Rather, for a period of one (1) year from  
date of original installation not to exceed Fifteen (15) months from date of shipment from factory, TRAULSEN:  
will replace, F.O.B. factory, any defective parts normally subject to warranty.  
will not cover the cost of packing, freight or labor such costs being the sole responsibility of the dealer.  
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND  
CONSTITUTES TRAULSEN’S FULL OBLIGATION AND LIABILITY. WARRANTIES NOT AVAILABLE ON  
REMOTE MODELS.  
-9-  
 
XI. INDEX  
A
N
Adjusting The Temperature  
6
Nylon Netting  
2
B
O
BTU’s  
Built-In Installation  
3
4
Outlet - Electrical  
3, 4, 5  
P
C
Pallet - Shipping  
Pans - Drawer  
Plastic Covering  
Power Supply  
2
7
2
3
Casters  
2
5
6
6
Cleaning - The Condenser  
Cleaning - The Exterior  
Cleaning - The Interior  
Clearance  
3
R
Compressor Hold Down Provisions  
Compressor - Oil  
Condensate Evaporator  
Condensing Unit  
Cord & Plug  
3
2
3
6, 8  
3
Recessed Installation  
Refrigerant  
Remote Installation  
Return Authorization  
4
2
3
2
S
D
Serial Tag  
Service Agents  
Shelf Pins  
Shelves  
1
7
3, 7  
3, 7  
3
Damage - Freight  
Defogger Control  
Defrost - Automatic  
Drawer  
2
5
6
7
7
Solenoid Valves  
Drawer Pans  
T
E
Temperature - Adjustment  
Thermometer  
6
5
Electrical Outlet - Location  
5
F
U
Fans  
Freight Claim  
6
2
U-Trap  
3
V
G
Gaskets  
6, 7  
6
W
Warranty  
Warranty, Registration  
Wiring Diagram  
9
8
H
Hinge - Replacement  
I
X
Y
Z
Interior Light  
Installation - Built-In  
Installation - Recessed  
7
4
4
J
K
Keys - Door  
2
L
Legs  
2
7
7
5
6
Lights - Interior  
Light Cover  
Light Switch  
Louver Assembly  
M
-10-  
 
HOURS OF OPERATION:  
Monday thru Friday 7:30 am - 4:30 pm CST  
Traulsen  
4401 Blue Mound Road Fort Worth, TX 76106  
Phone: (800) 825-8220 Fax-Svce: (817) 740-6757  
Quality Refrigeration  
© 2003 Traulsen - All Rights Reserved  
 

Texas Instruments Computer Drive TMS320F20x F24x DSP User Manual
Toastmaster Fryer Gas Electric Fryer User Manual
Toshiba Answering Machine FT 8901 User Manual
Toshiba Digital Camera IK TF5 User Manual
Toshiba DVD Player SD P2900 User Manual
Toshiba Film Camera 1080p 60 FP3 User Manual
Tricity Bendix Refrigerator ERC506 User Manual
UltraViolet Devices Air Cleaner Air Disinfection User Manual
ViewSonic Computer Monitor VA702 1 User Manual
ViewSonic Computer Monitor VS12844 User Manual