Trane Air Cleaner Air Filtration System User Manual

32- 5038- 01  
User’s Information Guide  
TM  
Trane CleanEffects Whole House Air Filtration System  
TM  
Congratulations – Your TRANE CleanEffects air filtration system is the most advanced,  
innovative and effective whole house air filtration system on the market today. It is designed to  
TM  
deliver what we call TRANE Air throughout your home. It delivers air that is meticulously filtered  
and cleaned of up to 99.98% of allergens to provide maximum comfort. You and your family can  
breathe easier than ever before.  
32-5038-01  
 
User’s Information  
SEQUENCE OF OPERATION  
!
CAUTION  
You will need to turn off your air cleaner to  
clean the filters. After cleaning, turn on the unit  
by pressing and releasing the Power button.  
The backlit Power and Filter Reset button will  
illuminate along with first green LED indicating  
power is present. When the indoor fan is oper-  
ating the first green LED will slowly flash. This  
indicates the field charger and collection cells  
have power and the unit is operating normally.  
There is a slight time delay between the indoor  
fan starting and LED flashing.  
This equipment should be inspected  
frequently and collected dirt removed from it  
regularly to prevent excessive accumulation  
that may result in flashover or risk of fire.  
The field charger should only be removed and  
cleaned by authorized service personnel.  
CLEANING INDICATORS  
Both the pre-filter and the collection cells have  
timers which monitor actual run time of the unit  
and indicate when cleaning is required. The  
time between cleaning can be adjusted based  
on your preferences and conditions in the  
home. See the SET-UP MODE section on  
page 5 to change the filter timers.  
NOTE: There is a 10 minute delay after the  
indoor fan operates, before the air cleaner  
starts to operate, each time the power to the  
air cleaner is turned off/on. This can be  
bypassed by going into and then out of the  
Set-Up Mode.  
The red PRE-FILTER light will illuminate when  
it is time to clean the pre-filter.  
Your air filtration system only operates when  
the air is circulating through the indoor unit.  
The air filtration system is most effective at  
cleaning the air if the fan operates  
continuously. Most thermostats have a setting  
that will permit continuous fan operation.  
Continuous fan mode during Cooling  
The clean/dirty light bar indicator will  
illuminate as the system cleans the air in your  
home. The lights will progress from green to  
yellow then to red. When the last red indicator  
is flashing it is time to clean the collection  
cells.  
operation may not be appropriate in humid  
climates. If the indoor air exceeds 60%  
relative humidity or simply feels  
REMOVING FILTERS FOR  
CLEANING  
uncomfortably humid, it is recommended that  
the fan only be used in the AUTO mode.  
In normal operation, the air cleaner may make  
a slight sound as the air passes through it and  
is cleaned. In some applications, you may  
notice this sound coming from the return air  
vent(s). If desired, this sound level can be  
reduced with minimal impact on air cleaning  
efficiency by reducing the power setting of the  
Turn the furnace/ air conditioning system off  
at the thermostat.  
!
CAUTION  
High voltage is present within the air cleaner  
for operation. Before removing the door, turn  
the power off and wait at least 15 seconds to  
allow voltage to discharge.  
field charger in the set-up mode (see p.5-6).  
Turn off power by pushing and holding the  
power button for approximately three seconds  
until all the LED’s illuminate. Release the  
power button. The LED’s will remain on until  
the voltage has discharged and it is safe to  
remove the door.  
MAINTENANCE  
In normal use, the pre-filter should be cleaned  
every 2 months and the collection cells should  
be cleaned every 6 months. The field charger  
should be cleaned only by a qualified service  
This requires approximately 15 seconds. Do  
technician annually.  
32-5035-02  
3
 
User’s Information  
WASHING  
not remove the door until all lights are off.  
Disconnect the power cable, if required,  
and place the door in a secure location.  
Rotate the two latches and remove the  
door.  
Use low-pressure water spray, such as a sink  
sprayer or garden hose to clean the cells.  
Stubborn residue like tobacco smoke may  
require warm water to be removed.  
PRE-FILTER CLEANING:  
The pre-filter can be vacuumed  
(recommended) or washed clean.  
Do NOT use soap or detergent in cleaning the  
collection cells.  
Do NOT immerse the cells completely in  
water.  
It is recommended the filter be vacuumed  
outside the home to ensure particles on the  
filter are not re-introduced into the air.  
Persons highly sensitive to the collected  
particles should wear appropriate respiratory  
protection while cleaning the filter.  
Do NOT place the cells into a dishwasher to  
clean.  
Slightly tap the collection cells to remove  
water retained in the filter. Allow the collection  
cells to dry completely before re-installing.  
The pre-filter can be washed using low  
pressure water spray, such as a sink sprayer  
or garden hose. The pre-filter should be  
completely dry before re-installing. Re-install  
the pre-filter noting the airflow direction as  
indicated on the filter.  
Re-install the collection cells. With the handles  
facing the front of the unit, align the slot on the  
cell with the tab on the cabinet. Fold the  
collection cell handles flat once installation is  
complete.  
NOTE: Do not replace the plastic pre-filter  
with a metal type pre-filter. A metal pre-filter  
will cause reduction in efficiency and  
RE-INSTALLING THE POWER  
DOOR  
Install the door by positioning tabs inside of the  
frame and rotating the door into place. Rotate  
the two latches to secure the door. Plug in the  
power cable if removed. Turn on power to the  
unit by pressing and releasing the power  
button.  
potential failure of the system electronics.  
COLLECTION CELL CLEANING  
Remove both collection cells from the system  
housing. The cells can be cleaned either by  
vacuuming (recommended method) or by  
washing.  
NOTE: The first green LED will be on but will  
not flash for the first 10 minutes the indoor fan  
is operating. This is a drying cycle for the pre-  
filter and collection cells.  
VACUUM CLEANING  
Using the wand attachment, vacuum both  
sides of the collection cells until they are clean  
RESET THE FILTER TIMERS  
To reset the pre-filter timer, press and hold the  
RESET button until the pre-filter LED turns off.  
(1 to 2 seconds)  
To reset the collection cell timer, press and  
continue to hold the RESET button until the  
collection cell LED’s turn off. (4 to 5 seconds)  
It is recommended the filter be vacuumed  
outside the home to ensure particles on the  
filter are not re-introduced into the air.  
Persons highly sensitive to the collected  
particles should wear appropriate respiratory  
protection while cleaning the filter.  
32-5035-02  
4
 
User’s Information  
SET-UP MODE  
You can customize the performance of the air  
cleaner to meet the needs of your home and  
family using the set-up mode.  
Factory settings  
To enter the set-up mode, press and hold  
BOTH the Power and the filter RESET buttons  
for a minimum of 5 seconds. The LED display  
will light up indicating the current settings as  
DIRTY  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
Field Charger Power  
Maximum  
shown in Figure 3 to the right.  
Collection Cell  
6 Months  
You may select the cleaning intervals of the  
pre-filter and the collection cells as well as the  
power setting of the field charger by cycling  
through the various settings (see page 6).  
Once you have made the desired changes,  
press and hold BOTH the Power and the filter  
RESET buttons for a minimum of 5 seconds to  
Pre-filter  
2 Months  
CLEAN  
Fig. 3  
exit the set-up mode.  
Pre-Filter Timer Setting  
The GREEN LED lights are used to set the pre-filter cleaning interval for one, two, or three  
months. The number of illuminated GREEN LED lights indicates the current setting. The factory  
setting is 2 months.  
Collection Cell Timer Setting  
The YELLOW LED lights are used to set the collection cells cleaning interval for two, four, six, or  
nine months. The number of illuminated YELLOW LED lights indicates the current setting as  
shown in Figure 5. The factory setting is 6 months.  
Field Charger Power Level Setting  
The RED LED lights are used to set the power level of the field charger for maximum, medium, or  
minimum. The number of illuminated RED LED lights indicates the current setting as shown in  
Figure 6. The factory setting is for maximum.  
Lower settings will reduce the slight sound emitted by the unit with minimal loss of air cleaning  
efficiency, if desired.  
Lower settings will also further reduce the very low ozone produced by the air cleaner. The U.S.  
Food and Drug Administration recommends indoor ozone concentrations should not exceed 50  
parts per billion. Your air cleaner will contribute only 5 parts per billion at the factory setting and  
can be reduced to 3 parts per billion at the minimum setting.  
32-5035-02  
5
 
User’s Information  
CHANGING THE SETTINGS  
While in the set-up mode, press the Power  
button once to begin cycling through the  
various setting options in the following order:  
DIRTY  
DIRTY  
DIRTY  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
Pre-Filter Cleaning Interval Setting  
(Figure 4)  
One or more of the GREEN LED lights will  
illuminate. To change the reminder interval  
time, press the Reset button until the desired  
setting is indicated, and then press the Power  
button again.  
CLEAN  
CLEAN  
CLEAN  
One  
Month  
Two  
Months *  
Three  
Months  
Fig. 4  
Collection Cells Cleaning Interval Setting  
(Figure 5)  
DIRTY  
DIRTY  
DIRTY  
DIRTY  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
R3  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
One or more of the YELLOW LED lights will  
illuminate. To change the reminder interval  
time, press the Reset button until the desired  
setting is indicated, and then press the Power  
button again.  
CLEAN  
CLEAN  
CLEAN  
CLEAN  
Two  
Four  
Six  
Nine  
Months Months  
Months* Months  
Fig. 5  
DIRTY  
DIRTY  
DIRTY  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
Field Charger Power Level Setting  
(Figure 6)  
One or more of the RED LED lights will  
illuminate. To change the power level setting,  
press the Reset button until the desired setting  
is indicated.  
CLEAN  
CLEAN  
CLEAN  
Minimum  
Medium  
Maximum*  
To save your new settings and exit the set-up  
mode, press and hold BOTH the Power and  
filter RESET buttons for a minimum of 5  
seconds.  
Fig. 6  
* Factory settings  
32-5035-02  
6
 
User’s Information  
FAULT INDICATORS  
DIRTY  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
The air cleaner has been designed to  
continually monitor itself to insure it is working  
properly. If it detects a problem, all four  
YELLOW LED lights will flash continuously.  
If this occurs, turn the unit off and clean both  
the pre-filter and the collection cells to insure  
no large material is trapped in the filters and  
causing the fault.  
CLEAN  
DIRTY  
R3  
R2  
R1  
Y4  
Y3  
Y2  
Y1  
G3  
G2  
G1  
If the unit detects any other type of fault, all  
three RED LED lights will flash continuously.  
The filter will shut down and does not  
represent a safety risk. You should call a  
qualified service technician for service.  
CLEAN  
32-5035-02  
7
 
Limited Warranty  
CleanEffects™ Whole  
House Air Cleaner  
TFD  
(Parts Only)  
This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the  
real property to which the CleanEffects™ Air Cleaner is originally affixed, and applies to products purchased and retained  
for use within the U.S.A. and Canada.  
If any part of your CleanEffects™ Air Cleaner fails because of a manufacturing defect within five years from the date of  
the original purchase, Warrantor will furnish without charge the required replacement part. In addition, if the electronics fail  
because of a manufacturing defect within the sixth through tenth year from the date of the original purchase, Warrantor  
will furnish without charge the required replacement part. Any local transportation, related service labor, mechanical filters  
and diagnosis calls are not included.  
This limited warranty does not cover failure of your CleanEffects™ Air Cleaner if it is damaged while in your possession,  
damage caused by unreasonable use of the CleanEffects™ Air Cleaner and/or damage from failure to properly maintain  
the CleanEffects™ Air Cleaner as set forth in the Use and Care manual (see Proper Maintenance section).  
THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER  
WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS OR  
IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR  
ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.  
Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or  
limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited  
warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
Parts will be provided by our factory organization through an authorized service organization in your area listed in the  
yellow pages. If you wish further help or information concerning this limited warranty, contact:  
American Standard Inc.  
Troup Highway  
Tyler, TX 75711-9010  
Attention: Manager, Field Operations Excellence  
TW-391-4005  
P.I.  
Trane  
Abusinessof  
AmericanStandardCompanies  
Trane has a policy of continuous product and product data improvement and it reserves the right to change  
design and specifications without notice.  
32-5038-01  
 

TDK Network Card HHM Series HHM1711E1 User Manual
Tektronix Smoke Alarm j17 User Manual
Timex Clock T020 User Manual
Topcom Blood Pressure Monitor 5331 WHO User Manual
Transition Networks Cable Box A CF 01 User Manual
Troy Bilt Lawn Mower 258 User Manual
ViewSonic Computer Monitor VS13918 User Manual
ViewSonic Flat Panel Television VT2730 User Manual
VTech Cordless Telephone VT 2931 User Manual
Wayne Water Pump 390601 001 User Manual