When setting sensitivity, make sure the room's environment is as close as  
possible to what it will be when the ENFORCER 190/190S is in use. For  
instance, if the curtains are usually closed at night when the alarm is  
armed, then set sensitivity with the curtains closed. If a window in the  
room is left opened, then set the sensitivity with window open. The  
sensitivity should always be retested when the environment of the room  
changes, such as when furniture is moved.  
OPERATING THE ENFORCER 190 / 190S  
MOUNTING THE DETECTOR  
It therefore should be mounted in a location within which every glass  
window and door to be protected is found. For greatest security, attach to  
the wall or ceiling, using screws instead of double-sided foam tape. For  
larger areas, two or more units can be used without fear of interfering with  
each other.  
Depending on the type of glass, sensitivity is different when set by tapping  
the inside or outside of the window with a ruler. For best results,  
tap the inside of the window.  
SETTING THE SENSITIVITY  
The ENFORCER 190/190S includes SECO-LARM's unique patented  
Yellow turbulence LED. This LED flashes when environmental noise is high  
enough to cause false alarms, thereby allowing instant sensitivity setting  
without the use of a special external test meter.  
NOTE: DO NOT SET SENSITIVITY ANY HIGHER THAN NECESSARY TO  
PROTECT THE GLASS IN THE DETECTOR'S RANGE. SETTING  
SENSITIVITY HIGHER THAN NEEDED INCREASES THE  
CHANCE OF FALSE ALARMS WITHOUT INCREASING  
PROTECTION. LEAVING A DOOR OR WINDOW OPEN WILL  
ALSO INCREASE THE CHANCE OF FALSE ALARMS.  
To set sensitivity, hold a thin flexible plastic ruler flat against a glass  
window within the unit's protection range.  
Pick up one end of the ruler while holding  
the other end down, and then let the ruler  
TAMPER-PROOFING CASE  
snap against the glass window. This  
For extra protection, the ENFORCER 190/190S is equipped with an  
N.C. Tamper Switch to protect against opening or breaking of the  
case.  
should cause the Yellow LED to come ON,  
but the Red LED should not light. If the  
Red LED comes ON with a slight snap, the  
ENFORCER 190/190S may be too  
MIN  
MAX  
INSTALLATION  
sensitive, and the sensitivity control should  
be turned counterclockwise with a small  
flat or phillips screwdriver. If the Yellow  
LED does not come ON, sensitivity should  
SCREW TERMINALS:  
be increased by turning the control clockwise. Continue snapping the ruler  
on the window until the Yellow LED comes ON but the Red LED does not.  
Repeat this process with each window to ensure the ENFORCER 190/  
190S is set for every pane of glass.  
#7: N.C. TAMPER OUTPUT  
#6: COMMON TAMPER OUTPUT  
#5: COMMON GROUND  
#4: 12VDC  
When the correct sensitivity is found using the above procedure, determine  
whether the sensitivity is high enough to trigger the alarm by snapping the  
ruler harder to simulate a break-in. If the Red LED does not come ON, the  
sensitivity must be increased.  
#3: DRY RELAY N.O.*  
#2: DRY RELAY COMMON*  
#1: DRY RELAY N.C.*  
NOTE: For applications within this temperature range the sensitivity will be  
stable. If the temperature should drop below -14°F (-10°C), the  
sensitivity of the ENFORCER 190/190S will increase, and the  
sensitivity setting will need to be decreased. If the temperature  
should rise above 122°F (50°C), the sensitivity of the  
ENFORCER 190/190S will decrease, and the sensitivity setting will  
need to be increased.  
* For N.O. output, use Terminals 2 and 3  
For N.C. output, use Terminals 2 and 1  
 

Radio Shack Postal Equipment PS100 User Guide
RCA Car Video System 811 727191W030 User Guide
RCA Flat Panel Television RLED3218 User Guide
Samsung Laptop 700Z5C User Guide
Sanus Systems TV Mount XAS1A User Guide
Sanyo Battery Charger RC 2400 User Guide
Sanyo Refrigerator MPR 1411 User Guide
Schwinn Exercise Bike SB13 User Guide
Sea Sea Digital Camera 2009 SLR User Guide
Senco Nail Gun SCN200 User Guide