RuggedCom Switch RS900GP User Guide

RuggedSwitch™  
RS900GP  
Hardware Installation Guide  
Revision 100 - November 10, 2011  
 
RuggedSwitch™ RS900GP  
Table of Contents  
FCC Statement And Cautions ................................................................................................... 6  
1. Product Overview ................................................................................................................... 7  
1.1. RS900GP Front Panel ................................................................................................ 9  
2. Installation ............................................................................................................................ 10  
2.1. DIN Rail Mounting ..................................................................................................... 10  
2.2. Panel Mounting Options ............................................................................................ 11  
2.2.1. RS900GP Front Panel Mount Option ............................................................. 11  
2.2.2. RS900GP Rear Panel Mount Option ............................................................. 12  
2.2.3. RS900GP Side Panel Mount Option .............................................................. 13  
2.3. DC Power Supply Wiring and Grounding ................................................................. 14  
2.4. Failsafe Output Wiring and Specifications ................................................................ 15  
2.5. RS232 Port Wiring .................................................................................................... 15  
2.6. RJ45 Ports: Signal Description ................................................................................. 16  
3. Specifications ....................................................................................................................... 17  
3.1. Operating Environment ............................................................................................. 17  
3.2. Power Supply Specifications ..................................................................................... 17  
3.2.1. General ........................................................................................................... 17  
3.2.2. IEEE802.3AF .................................................................................................. 17  
3.2.3. IEEE802.3AT .................................................................................................. 17  
3.3. Failsafe Relay Specifications .................................................................................... 17  
3.4. Twisted Pair Data Port Specifications ....................................................................... 18  
3.5. Fiber Optic Port Specifications .................................................................................. 19  
3.6. Physical Dimensions ................................................................................................. 20  
3.7. Type Test Specifications ........................................................................................... 21  
3.7.1. IEC 61850-3 Type Tests ................................................................................ 21  
3.7.2. IEEE 1613 Type Tests ................................................................................... 22  
3.7.3. IEC Environmental Type Tests ...................................................................... 22  
3.8. Agency Approvals ..................................................................................................... 23  
A. Warranty .............................................................................................................................. 24  
RuggedCom® RuggedSwitch™  
3
RS900GP Installation Guide Rev 100  
 
RuggedSwitch™ RS900GP  
List of Figures  
1.1. RS900GP Front Panel ........................................................................................................ 9  
2.1. DIN Rail Mounting ............................................................................................................ 10  
2.2. Front Panel Mounting ....................................................................................................... 11  
2.3. Rear Panel Mounting ........................................................................................................ 12  
2.4. Side Panel Mounting ......................................................................................................... 13  
2.5. DC Power Supply Wiring and Grounding ......................................................................... 14  
2.6. RS900GP Chassis Ground Connection ............................................................................ 14  
2.7. Failsafe Output Relay ....................................................................................................... 15  
2.8. RS232 Female Connector ................................................................................................ 15  
2.9. RJ45 Port Connector ........................................................................................................ 16  
3.1. RS900GP Physical Dimensions ........................................................................................ 20  
RuggedCom® RuggedSwitch™  
4
RS900GP Installation Guide Rev 100  
 
RuggedSwitch™ RS900GP  
List of Tables  
1.1. Front Panel LED Definitions ............................................................................................... 9  
2.1. RS232 Female DCE Pinout .............................................................................................. 15  
2.2. RJ45 Ethernet Pin Assignment ......................................................................................... 16  
3.1. Operating Environment ..................................................................................................... 17  
3.2. RS900GP Power Supply Specifications ........................................................................... 17  
3.3. IEEE802.3AF Power Supply Ratings ................................................................................ 17  
3.4. IEEE802.3AT Power Supply Ratings ................................................................................ 17  
3.5. Failsafe Relay Specifications ............................................................................................ 17  
3.6. Twisted Pair Data Port Specifications ............................................................................... 18  
3.7. Fiber Optic Port Specifications ......................................................................................... 19  
3.8. Physical Specifications ...................................................................................................... 20  
3.9. RS900GP IEC 61850-3 Type Tests ................................................................................. 21  
3.10. RS900GP IEEE 1613 Type Tests .................................................................................. 22  
3.11. IEC Environmental Type Tests ....................................................................................... 22  
3.12. Agency Approvals ........................................................................................................... 23  
RuggedCom® RuggedSwitch™  
5
RS900GP Installation Guide Rev 100  
 
FCC Statement And Cautions  
FCC Statement And Cautions  
Federal Communications Commission Radio Frequency Interference  
Statement  
This equipment has been tested and found to comply with the limits for a Class A digital device  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which  
case the user will be required to correct the interference at his own expense.  
Caution: LASER  
This product contains a laser system and is classified as a CLASS 1 LASER  
PRODUCT. Use of controls or adjustments or performance of procedures other than  
those specified herein may result in hazardous radiation exposure.  
Caution: Service  
This product contains no user-serviceable parts. Attempted service by unauthorized  
personnel shall render all warranties null and void.  
Changes or modifications not expressly approved by RuggedCom Inc. could invalidate  
specifications, test results, and agency approvals, and void the user’s authority to  
operate the equipment.  
Should this device require service, refer to Appendix A, Warranty in this guide.  
Caution: Physical Access  
This product should be installed in a restricted access location where access can only  
be gained by service personnel or users who have been instructed about the reasons  
for the restrictions applied to the location and about any precautions that shall be taken;  
and access is through the use of a tool or lock and key, or other means of security,  
and is controlled by the authority responsible for the location.  
Caution: Hot Surfaces  
When in operation, regions of the unit surface may be hot.  
Caution: Lithium Battery  
This product contains a Lithium battery that is not replaceable by the operator or by  
service personnel.  
RuggedCom® RuggedSwitch™  
6
RS900GP Installation Guide Rev 100  
 
 
1. Product Overview  
1. Product Overview  
The RuggedSwitch™ RS900GP is an industrially hardened, fully managed Ethernet switch  
providing dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports - each  
capable of supplying high power 802.3at compliant power over Ethernet. Designed to operate  
reliably in harsh industrial environments, the RS900GP provides a high level of immunity to  
electromagnetic interference and heavy electrical surges typical of environments found in electric  
utility substations, factory floors or in curb side traffic control cabinets. An operating temperature  
range of -40°C to +85°C coupled with hazardous location certification, a powder coated aluminum  
enclosure and optional conformal coating allows the RS900GP to be placed in almost any location.  
The embedded Rugged Operating System (ROS™) provides advanced networking features such  
as Enhanced Rapid Spanning Tree (eRSTP™), Port Rate Limiting and a full array of intelligent  
functionality for high network availability and manageability.  
Ethernet Ports  
• Up to 2 - Fiber Optic Gigabit-Ethernet Ports(100/1000BaseX)  
• 8 - Fast Ethernet Ports (10/100BaseTX) all external 802.3af/802.3at compliant PoE  
• Up to 2 - 10/100/1000 BaseTX copper ports  
• Full compliance with IEEE: 802.3, 802.3u and 802.3z  
• Non-blocking, store and forward switching  
• Full duplex operation and flow control (IEEE 802.3x)  
• Industry standard fiber optical connectors: LC, SC, SFP  
• Bi-Directional simplex fiber support  
• Long haul optics allow Gigabit distances up to 70km  
Power Over Ethernet (PoE)  
• 8-10/100 BaseTx 802.3af/802.3at compliant ports  
• Data and power over a single Ethernet cable  
• Auto-sensing ports that provide power only to PoE end devices  
RuggedRated™ for Reliability in Harsh Environments  
• Meets IEEE 1613 (electric utility substations)  
• Exceeds IEC 61850-3 (electric utility substations)  
• Exceeds IEEE 61800-3 (variable speed drive systems)  
• Exceeds IEC 61000-6-2 (generic industrial environment)  
• Exceeds NEMA TS-2 (traffic control equipment)  
• Hazardous Location Certification: Class 1 Division 2  
• -40 to +85°C operating temperature (no fans)  
• Conformal coated circuit boards (optional)  
• Rugged powder coated aluminum enclosure  
RuggedCom® RuggedSwitch™  
7
RS900GP Installation Guide Rev 100  
 
 
1. Product Overview  
Power Supply  
• 2 (redundant) 54VDC inputs (51-57VDC)  
• Supports 8 30W PoE powered devices (minimum 260W total output)  
• Supports power supply sharing  
• Reverse polarity protection  
• CSA/UL 60950 safety approved to +85°C  
Simple Plug and Play Operation  
• Plug and play operation 802.3af/802.3at  
• Automatic learning of up to 8192 MAC addresses  
• Auto-negotiation on all 10/100BaseTX ports  
• Auto-MDI/MDIX (crossover) on all 10/100BaseTX ports  
• LED indicators for Link/Activity and Power  
ROS™ Advanced Network Management  
• Enhanced Rapid Spanning Tree (eRSTPTM)  
• Quality of Service (802.1p) for real-time traffic  
• Port rate limiting: 128kbps to 8Mbps  
• VLAN (802.1q) with double tagging  
• IGMP Snooping for multicast filtering  
• Port configuration, status, statistics, mirroring, security  
• Loss of link management on fiber ports  
• Web-based, Telnet, CLI management interfaces  
• SNMP v2 and RMON  
• Rich set of diagnostics with logging and alarms  
RuggedCom® RuggedSwitch™  
8
RS900GP Installation Guide Rev 100  
 
1. Product Overview  
1.1. RS900GP Front Panel  
Figure 1.1. RS900GP Front Panel  
LED Indicator  
LED Color and State  
Green, steady.  
Description  
Power LED  
Power is on.  
Alarm LED  
Red, steady.  
Alarm condition exists.  
Network link.  
Ethernet Port 1-8 Link LED  
Green, steady.  
Ethernet Port 1-8 Link LED  
Ethernet Port 1-8 PoE LED  
Ethernet Port 1-8 PoE LED  
Green, blinking.  
Orange, steady.  
Orange, blinking.  
Off.  
Network activity.  
PoE is enabled and powered on.  
PoE is enabled and powered off.  
PoE is disabled.  
Ethernet Port 1-8 PoE LED  
Table 1.1. Front Panel LED Definitions  
RuggedCom® RuggedSwitch™  
9
RS900GP Installation Guide Rev 100  
 
     
2. Installation  
2. Installation  
2.1. DIN Rail Mounting  
An optional DIN rail mounting bracket is available for the RS900GP.  
Figure 2.1. DIN Rail Mounting  
RuggedCom® RuggedSwitch™  
10  
RS900GP Installation Guide Rev 100  
 
     
2. Installation  
2.2. Panel Mounting Options  
The RS900GP can be equipped with front, rear, or side panel mount brackets.  
2.2.1. RS900GP Front Panel Mount Option  
The front panel mounting brackets fit flush with the front of the RS900GP.  
Figure 2.2. Front Panel Mounting  
RuggedCom® RuggedSwitch™  
11  
RS900GP Installation Guide Rev 100  
 
     
2. Installation  
2.2.2. RS900GP Rear Panel Mount Option  
The rear panel mounting brackets fit flush with the rear of the RS900GP.  
Figure 2.3. Rear Panel Mounting  
RuggedCom® RuggedSwitch™  
12  
RS900GP Installation Guide Rev 100  
 
   
2. Installation  
2.2.3. RS900GP Side Panel Mount Option  
The side panel mounting brackets fit flush with the side of the RS900GP.  
Figure 2.4. Side Panel Mounting  
RuggedCom® RuggedSwitch™  
13  
RS900GP Installation Guide Rev 100  
 
   
2. Installation  
2.3. DC Power Supply Wiring and Grounding  
Figure 2.5. DC Power Supply Wiring and Grounding  
The RS900GP low voltage DC power supply features reverse polarity protection and dual  
independent inputs. This feature allows the connection of two DC sources with the same nominal  
voltage to provide redundant power supply inputs. The DC source must be connected to the DC  
inputs according to the polarity markings on the unit.  
1. Equipment must be installed according to the applicable country wiring codes.  
2. Surge Ground should be connected to Chassis Ground via a braided cable or  
other appropriate ground wire.  
3. Chassis Ground must be connected to the protective earth.  
4. All line-to-ground transient energy is shunted to the Surge Ground terminal. In  
cases where users require the DC inputs to be isolated from ground, remove the  
ground braid between Surge and Chassis Ground. Note that all line-to-ground  
transient protection circuitry will be disabled.  
Figure 2.6. RS900GP Chassis Ground Connection  
RuggedCom® RuggedSwitch™  
14  
RS900GP Installation Guide Rev 100  
 
     
2. Installation  
2.4. Failsafe Output Wiring and Specifications  
The “Failsafe” output relay is provided to signal critical error conditions that may occur on the  
RS900GP. The contacts are energized upon power up of the unit and remain energized until an  
alarm condition or power loss occurs.  
Figure 2.7. Failsafe Output Relay  
2.5. RS232 Port Wiring  
The RS232 port is used for configuring the unit. A straight-through serial cable with a DB-9  
connector is required. There is no need to crossover the Transmit and Receive signals from the  
PC side since this has been done internally as shown in the figure below.  
Figure 2.8. RS232 Female Connector  
Pin  
1
Signal  
No Connection  
Transmit Data  
Receive Data  
No Connection  
Ground  
2
3
4
5
6
No Connection  
No Connection  
No Connection  
No Connection  
7
8
9
Table 2.1. RS232 Female DCE Pinout  
This port is not intended to be a permanent connection and the cable shall be less  
than 2m (6.5 ft) in length.  
RuggedCom® RuggedSwitch™  
15  
RS900GP Installation Guide Rev 100  
 
         
2. Installation  
2.6. RJ45 Ports: Signal Description  
The RS900GP has several 10/100BaseTX ports that allow connection to standard CAT-5 UTP  
cable with RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis  
ground on the unit and can accept shielded CAT-5 cables. If shielded cables are used, care must  
be taken to ensure the shielded cables do not form a ground loop via the shield wire and the RJ45  
receptacles at either end.  
Figure 2.9. RJ45 Port Connector  
RJ45 Pin  
10/100Base-Tx  
10/100/1000Base-Tx  
1
2
3
4
5
6
7
8
RX+  
RX-  
TX+  
NC  
A+  
A-  
B+  
C+  
C-  
B-  
NC  
TX-  
NC  
D+  
D-  
NC  
Table 2.2. RJ45 Ethernet Pin Assignment  
RuggedCom does not recommend the use of CAT-5 cabling of any length for critical  
real-time substation automation applications. However, transient suppression circuitry  
is present on all copper ports to protect against damage from electrical transients and  
to ensure IEC 61850-3 and IEEE 1613 Class 1 conformance. This means that during  
the transient event communications errors or interruptions may occur but recovery is  
automatic.  
RuggedCom also does not recommended to use these ports to interface to field  
devices across distances which could produce high levels of ground potential rise, (i.e.  
greater than 2500V) during line to ground fault conditions.  
RuggedCom® RuggedSwitch™  
16  
RS900GP Installation Guide Rev 100  
 
     
3. Specifications  
3. Specifications  
3.1. Operating Environment  
Parameter  
Range  
Comments  
Ambient Temperature as measured  
from a 30cm radius surrounding the  
center of the RS900GP enclosure.  
Ambient Operating Temperature  
-40 to 85°C  
Ambient Relative Humidity  
Ambient Storage Temperature  
Operating Altitude  
5% to 95%  
-40 to 85°C  
Non-condensing  
0 to 15240m (0 to 50000 ft)  
Over temperature range of -40 to 85°C  
Table 3.1. Operating Environment  
3.2. Power Supply Specifications  
3.2.1. General  
RS900GP  
Maximum  
Power  
Maximum  
Combined  
Power Output  
at PoE Ports  
Power  
Supply Type  
Minimum Input Maximum Input  
Fuse Rating  
6.3A (T) a  
Isolation  
Consumption  
54 VDC  
45 VDC  
57 VDC  
1.5 kV DC  
15W  
273W  
a (T) denotes time-delay fuse  
Table 3.2. RS900GP Power Supply Specifications  
3.2.2. IEEE802.3AF  
Power In  
Power Out  
45-57 VDC, 3.5 A MAX  
44-57 VDC, 15 W/PORT MAX  
Table 3.3. IEEE802.3AF Power Supply Ratings  
3.2.3. IEEE802.3AT  
Power In  
Power Out  
51-57 VDC, 6 A MAX  
50-57 VDC, 30 W/PORT MAX  
Table 3.4. IEEE802.3AT Power Supply Ratings  
3.3. Failsafe Relay Specifications  
Parameter  
Value  
Max Switching Voltage  
30VAC, 80VDC  
0.3A @ 30VAC  
1A @ 30VDC, 0.3A @ 80VDC  
Rated Switching Current  
Table 3.5. Failsafe Relay Specifications  
• Resistive Load.  
• For Class-2 circuits only.  
RuggedCom® RuggedSwitch™  
17  
RS900GP Installation Guide Rev 100  
 
                       
3. Specifications  
3.4. Twisted Pair Data Port Specifications  
Data Port  
Media  
Distance  
Connector Type  
10/100 Mbps  
Cat 5 UTP or STP  
100m  
RJ45  
Table 3.6. Twisted Pair Data Port Specifications  
RuggedCom® RuggedSwitch™  
18  
RS900GP Installation Guide Rev 100  
 
   
3. Specifications  
3.5. Fiber Optic Port Specifications  
For maximum flexibility, RuggedCom Inc. offers a number of different transceiver choices for  
Gigabit fiber optic communications. The following table details fiber optic specifications based on  
the order code/transceiver selected at time of ordering.  
Typical  
Mode /  
Connector  
Cable  
Tx Pwr (dBm) Rx Sensitivity Rx Saturation  
Order Code  
Distance  
Type 1. a  
(Min/Max) b  
(dBm) b  
(dBm) b  
Tx λ (nm)  
(km) c  
2LCMM  
2LC10  
2LC25  
2SC10  
2SC25  
SFP  
MM / LC  
SM / LC  
SM / LC  
SM / SC  
SM / SC  
MM / LC  
SM / LC  
SM / LC  
SM / LC  
SM / LC  
850  
1310  
1310  
1310  
1310  
850  
-9.5 / -4  
-9.5 / -3  
-5 / 0  
-20  
-22  
-22  
-22  
-24  
-22  
-24  
-26  
-26  
-26  
0
-3  
-3  
-3  
-3  
-3  
0
0.5  
10  
25  
10  
25  
0.5  
10  
25  
50  
80  
50µ/125  
9µ/125  
9µ/125  
9µ/125  
9µ/125  
50µ/125  
9µ/125  
9µ/125  
9µ/125  
9µ/125  
-10 / -3  
-7 / -3  
-8.5 / -4  
-9 / -3  
-7 / -3  
-5 / 0  
SFP  
1310  
1310  
1550  
1550  
SFP  
-3  
0
SFPd  
SFP d  
0 / 5  
0
SM / SC  
Simplex  
SFP  
1310  
-9 / -3  
-9 / -3  
-22  
-22  
-3  
-3  
10  
10  
9µ/125  
SM / SC  
Simplex  
SFP d  
1490  
9µ/125  
a All cabling is duplex type unless otherwise specified.  
b All optical power numbers are listed as dBm averages.  
c
Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and splices.  
Please consult RuggedCom sales associates when determining maximum segment distances.  
d These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20#C to +85#C operation only.  
Table 3.7. Fiber Optic Port Specifications  
RuggedCom® RuggedSwitch™  
19  
RS900GP Installation Guide Rev 100  
 
   
3. Specifications  
3.6. Physical Dimensions  
Figure 3.1. RS900GP Physical Dimensions  
Parameter  
Value  
Comments  
6.95 × 3.63 × 6.08 inches  
( 17.653 × 9.22 × 14.4432 cm)  
Dimensions  
(Length × Width × Depth  
Weight  
Ingress Protection  
To be determined  
IP40  
(1mm objects)  
Enclosure  
Cast Aluminum  
Table 3.8. Physical Specifications  
RuggedCom® RuggedSwitch™  
20  
RS900GP Installation Guide Rev 100  
 
     
3. Specifications  
3.7. Type Test Specifications  
3.7.1. IEC 61850-3 Type Tests  
Severity  
Levels  
Test  
Description  
Test Levels  
Enclosure Contact  
Enclosure Air  
+/- 8kV  
+/- 15kV  
4
4
x
x
4
4
IEC 61000-4-2  
IEC 61000-4-3  
ESD  
Radiated RFI  
Enclosure ports  
Signal ports  
20 V/m  
+/- 2kV @ 2.5kHz  
+/- 2kV  
IEC 61000-4-4  
IEC 61000-4-5  
IEC 61000-4-6  
Burst (Fast Transient)  
Surge  
D.C. Power ports  
Earth ground ports  
+/- 2kV  
+/- 2kV line-to-earth,  
+/- 1.5kV line-to-line  
Signal ports  
4
3
+/- 1.5kV line-to-earth,  
+/- 1kV line-to-line  
D.C. Power ports  
Signal ports  
10V  
10V  
10V  
3
3
3
Induced (Conducted) RFI  
D.C Power ports  
Earth ground ports  
40 A/m continuous,  
1000 A/m for 1 s  
IEC 61000-4-8  
IEC 61000-4-29  
Magnetic Field  
Enclosure ports  
D.C. Power ports  
Signal ports  
N/A  
N/A  
3
30% for 0.1s, 60% for  
0.1s, 100% for 0.05s  
Voltage Dips & Interrupts  
2.5kV common, 1kV  
differential mode @ 1MHz  
IEC 61000-4-12  
Damped Oscillatory  
2.5kV common, 1kV  
differential mode @ 1MHz  
D.C. Power ports  
3
Signal ports  
30V Continuous, 300V for 1s  
30V Continuous, 300V for 1s  
10%  
4
4
3
IEC 61000-4-16  
IEC 61000-4-17  
Mains Frequency Voltage  
D.C. Power ports  
D.C. Power ports  
Ripple on D.C. Power Supply  
1.5kV AC (Fail-  
Safe Relay output)  
Signal ports  
N/A  
IEC 60255-5  
IEC 60255-5  
Dielectric Strength  
H.V. Impulse  
D.C. Power ports  
Signal ports  
1.5kV DC  
5kV (Fail-Safe Relay output)  
5kV  
N/A  
N/A  
N/A  
D.C. Power ports  
Table 3.9. RS900GP IEC 61850-3 Type Tests  
RuggedCom® RuggedSwitch™  
21  
RS900GP Installation Guide Rev 100  
 
     
3. Specifications  
3.7.2. IEEE 1613 Type Tests  
IEEE Test  
C37.90.3  
C37.90.2  
IEEE 1613 Clause  
Description  
Test Levels  
+/- 8kV  
Enclosure Contact  
Enclosure Air  
9
8
ESD  
+/- 12kV  
35 V/m  
Radiated RFI  
Enclosure ports  
+/- 2kV  
@ 2.5kHz  
Signal ports  
C37.90.1  
C37.90.1  
7
7
Fast Transient  
D.C. Power ports  
Earth ground ports  
+/- 2kV  
+/- 2kV  
2.2kV  
common  
mode @  
1MHz  
Signal ports  
Oscillatory  
2.2kV  
common &  
differential  
mode @  
1MHz  
D.C. Power ports  
5 kV (Failsafe  
Relay)  
Signal ports  
C37.90  
C37.90  
6
6
H.V. Impulse  
D.C. Power ports  
5 kV  
2kV  
AC(Failsafe  
Relay)  
Signal ports  
Dielectric Strength  
D.C. Power ports  
1.2kV DC  
Table 3.10. RS900GP IEEE 1613 Type Tests  
• If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During  
disturbance errors may occur but recovery is automatic).  
• If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During  
disturbance no errors will occur).  
3.7.3. IEC Environmental Type Tests  
Test  
IEC 60068-2-1  
Description  
Cold Temperature  
Test Levels  
-40°C, 16 Hours  
+85°C, 16 Hours  
Severity Levels  
Test Ad  
Test Bd  
N/A  
N/A  
IEC 60068-2-2  
IEC 60068-2-30  
Dry Heat  
Humidity (Damp  
Heat, Cyclic)  
95% (non-condensing),  
55°C, 6 cycles  
Test Db  
N/A  
IEC 60255-21-1  
IEC 60255-21-2  
Vibration  
Shock  
2g @ (10-150) Hz  
30g @ 11 ms  
Class 2  
Class 2  
Table 3.11. IEC Environmental Type Tests  
RuggedCom® RuggedSwitch™  
22  
RS900GP Installation Guide Rev 100  
 
       
3. Specifications  
3.8. Agency Approvals  
Agency  
Standards  
Comments  
CSA  
CSA C22.2 No. 60950, UL 60950  
Approved  
CE Compliance is claimed via  
Declaration of Self Conformity Route  
CE  
EN 60950, EN 61000-6-2  
FCC  
CISPRa  
FCC Part 15, Class A  
EN55022, Class A  
Approved  
Approved  
Approved  
Approved  
FDA/CDRH  
IEC/EN  
21 CFR Chapter 1, Subchapter J  
EN60825-1:1994 + A11:1996 + A2:2001  
Hazardous Locations  
CSA  
Class 1, Division 2, Groups A, B, C,& D.  
T6 rating at 40°C, T4A rating at 85°C  
Approved  
a With the use of shielded Ethernet cables.  
Table 3.12. Agency Approvals  
RuggedCom® RuggedSwitch™  
23  
RS900GP Installation Guide Rev 100  
 
   
Appendix A. Warranty  
Appendix A. Warranty  
RuggedCom warrants this product for a period of five (5) years from the date of purchase. This  
product contains no user-serviceable parts. Attempted service by unauthorized personnel shall  
render all warranties null and void. For warranty details, visit www.RuggedCom.com or contact  
your customer service representative.  
Should this product require service, contact the factory at:  
RuggedCom Inc.  
300 Applewood Crescent  
Concord, Ontario  
Canada L4K 5C7  
Phone: +1 905 856 5288  
Fax: +1 905 856 1995  
RuggedCom® RuggedSwitch™  
24  
RS900GP Installation Guide Rev 100  
 
 

Radio Shack Cordless Telephone 43 3549 User Guide
Roadmaster Car Speaker Car Component Speaker User Guide
Roland Recording Equipment CSQ 500 User Guide
Samsung Bluetooth Headset 100705 User Guide
Samsung Computer Accessories VGSTC3000ZA User Guide
Samsung Laptop X65 User Guide
Samsung Microwave Oven SMH7198STD User Guide
Sanyo Projector PLC XF30 User Guide
SATO Printer S8408 User Guide
Schneider Optics Network Router Modicon Quantum Ethernet User Guide