Rheem Water Heater 54KW User Guide

6KW - 54KW Electric Booster  
Commercial Water Heaters  
10 Gallon Capacity  
6KW thru 54KW  
Rheem-Ruud Electric Booster Water Heaters are specifically designed to fit under  
counters and deliver 180°F sanitizing rinse water for all stationary rack and convey-  
or type commercial dishwashers. They will raise preheated or cold water to 180°F  
rinse temperature for compliance with UL Sanitation (NSF5) and all Federal, State,  
County and Local Health Department Sanitation Codes. In addition, these models  
can be used as circulating tank commercial electric water heaters for gravity or  
pump circulation to an auxiliary storage tank.  
208, 240,  
277 and 480  
Voltages  
Construction Features:  
System Sentinel –  
Long life heating elements –  
separate screw-in type elements  
feature a Nichrome wire filament,  
embedded in magnesium oxide  
sealed in a copper tube to resist  
water chemical corrosion…for long  
element life and a long life perform-  
ance. Elements are directly immersed  
in the water for maximum recovery  
efficiency (98%) and are easily  
changed by simply screwing new  
ones into the tank.  
Immersion  
Thermostat(s)  
all electric booster models employ an  
element diagnostic panel, utilizing  
light emitting diodes (L.E.D.), corre-  
sponding to the number and location  
of each heating element. L.E.D.’s are  
energized when the electric elements  
are operating. An unlit L.E.D.  
pinpoints the exact location of a  
non-functioning element, making  
element operation diagnosis simple  
and positive.  
®
Long life tank design –  
proprietary steel formulation with a  
unique coat of high temperature  
porcelain enamel to maximize  
corrosion resistance resulting in a  
superior tank design.  
Certifications and Ratings:  
• Efficiency – these models meet or exceed thermal efficiency and standby loss  
requirements of current ASHRAE standards. (Part of the Federally mandated  
Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states  
including California Energy Commission (CEC).  
• Safety and construction – these products are design certified by Underwriters  
Laboratories (UL) to meet UL standard 1453 as electric booster and commercial  
storage tank water heaters. All models are UL Sanitation (NSF5) and North  
Carolina Code compliant.  
CERTIFIED FOR A 150 PSI MAXIMUM WORKING PRESSURE.  
Continued next page.  
 
Factory Accessories From Rheem-Ruud:  
Solid state low water cut-off probe type cut-off for field installation (AP8408).  
MODEL  
INPUT  
KW  
NUMBERS  
Fuse type – the Gin the model number represents  
Class G fuses.  
E10-6-G  
6
E10-9-G  
9
E10-12-G  
E10-15-G  
E10-18-G  
E10-24-G  
E10-27-G  
E10-30-G  
E10-36-G  
E10-45-G  
E10-54-G  
12  
15  
18  
24  
27  
30  
36  
45  
54  
Fuseless construction – any standard model not exceeding  
48 Amps (See Electrical CharacteristicsTable) may be ordered  
without element fuses. Add Nafter the fuse type designation.  
Example: E10-9-G becomes E10-9-GN  
Approximate Shipping Weight 110 lbs./50 kgs.  
OPTIONAL THERMOSTATS  
(GS MODELS ONLY)  
THERMOSTAT  
213/4  
"
11/4" HOT  
OUTLET  
NIPPLE  
TEMPERATURE  
LIMIT CONTROL  
81/4  
"
T&P  
11/4" COLD  
INLET  
NIPPLE  
OUTLET  
43/4  
"
17"  
133/4  
"
INLET  
53/4  
"
TRANSFORMER  
TERMINAL  
BLOCK  
6"  
211/2  
"
CONTACTORS  
FUSE BLOCKS (FUSED MODELS ONLY)  
WATER TEMPERATURE RATINGS  
Minimum  
Delivered  
Temperature  
Maximum  
Delivered  
Temperature  
High  
Temperature  
Limit  
Model  
Tank  
Capacity  
Thermostat  
Type  
Number  
E10  
10 Gal./ 38L  
Immersion  
90°F/ 32.2°C  
190°F/ 87.8°C  
200°F/ 93.3°C  
 
Electric Booster continued.  
Other Features:  
Integral fusing all models have integral  
120 volt control circuit all units are furnished  
with a fused 120 volt control circuit. All controls  
(thermostats, high temperature limit, etc.) are  
operated off of this basic 120 volt control circuit.  
This circuit is created by an internal multi-tap  
transformer of unique design that has four  
(4) taps for the primary voltages, 208, 240,  
277 and 480.  
fusing for each element.  
Anode rods two (2) magnesium anodes  
are installed in each tank for maximum  
corrosion resistance.  
Temperature and pressure relief valve –  
AGA/ASME rated and factory installed.  
Electrical connections pre-wired, accessible  
control box with multiple knock-outs on side in  
size selections to match the National Electric  
Code. Sizes range from 1/2" to 2". A grounding  
screw is provided for attaching an equipment  
grounding conductor.  
Water connections hot outlet and cold inlet  
are 1-1/4" NPT dielectric nipples which prevent  
excessive turbulence of heated water and  
results in optimum tank draw.  
Heavy insulation an effective blanket of  
insulation completely surrounds tanks to limit  
heat loss and assure high operating efficiency.  
Single panel control box with hinged  
stainless steel door, provides immediate access  
to all electrical components and elements.  
Stainless steel legs 6" stainless steel legs  
are provided with each unit.  
Terminal block all models are equipped  
with UL Listed terminal blocks for simplicity of  
installation. The terminal block will accept either  
copper or aluminum field connect wire.  
Recommended Specifications  
Water heater(s) shall be model ________________, manufactured by RHEEM-RUUD, having electrical  
input of __________ kW and a recovery rate of _____________ GPH at a 100°F temperature rise.  
Water heater(s) shall have a storage capacity of 10 gallons. Water heater(s) shall have the UL seal of  
certification and be factory equipped with an AGA/ASME rated temperature and pressure relief valve.  
Tank(s) shall have a unique coating of high temperature porcelain enamel and furnished with magne-  
sium anode rods rigidly supported. Water heater(s) shall meet or exceed the efficiency requirements of  
ASHRAE. Tank(s) shall have a working pressure rating of 150 psi, and shall be completely assembled.  
Water heater(s) shall be approve-listed and constructed in accordance with UL Sanitation (NSF5).  
Water heater(s) shall be equipped with screw-intype elements. Water heater(s) shall be constructed  
with a SYSTEM SENTINEL element diagnostic panel utilizing light emitting diodes. Each LED will  
correspond to the number and location of the heating elements and monitor their on-off function. Water  
heater(s) shall be provided with internal power circuit fusing, control circuit fusing, magnetic contactors,  
120 volt control circuit transformer and immersion thermostat(s) with manual reset high limit control.  
1-1/4" inlet and outlet water connections shall be provided. Water heater(s) shall be covered by a three  
year limited warranty against tank leaks.  
Limited Warranty  
This product features a three year limited warranty against tank leaks.  
Please refer to Commercial Warranty Information brochure for  
complete warranty information.  
C O M M E R C I A L  
W A T E R H E A T E R S  
In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.  
Rheem Water Heating 101 Bell Road, Montgomery, Alabama 36117-4305 www.rheem.com  
PRINTED IN U.S.A  
10/06 WP  
FORM NO. RR102CE-2 Rev. 10  
 

RIDGID Nail Gun R350RHA User Guide
RIDGID Saw R3210 User Guide
Robic Fitness Electronics M329 User Guide
Ryobi Outdoor Chainsaw RY74003D User Guide
Samsung Camcorder VP X300 User Guide
Samsung Cell Phone Accessories EPL 1PL0BEGXAR User Guide
Samsung Cell Phone C3050 User Guide
Samsung Printer CLP 310N User Guide
Scosche Industries CD Player HDJ 2450 User Guide
Sears Refrigerator GR 051SF User Guide