REJ10J1868-0200
H8SX/1658R Group E6000H PLQP0120LA-A
User System Interface Board
HS1658RECN61H User’s Manual
Renesas Microcomputer Development Environment System
H8SX Family / H8SX/1600 Series
HS1658RECN61HE
Rev.2.00
Revision Date: Sep. 08, 2008
Notes regarding these materials
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate
Renesas products for their use. Renesas neither makes warranties or representations with respect to the
accuracy or completeness of the information contained in this document nor grants any license to any
intellectual property rights or any other rights of Renesas or any third party with respect to the information in
this document.
2. Renesas shall have no liability for damages or infringement of any intellectual property or other rights arising
out of the use of any information in this document, including, but not limited to, product data, diagrams, charts,
programs, algorithms, and application circuit examples.
3. You should not use the products or the technology described in this document for the purpose of military
applications such as the development of weapons of mass destruction or for the purpose of any other military
use. When exporting the products or technology described herein, you should follow the applicable export
control laws and regulations, and procedures required by such laws and regulations.
4. All information included in this document such as product data, diagrams, charts, programs, algorithms, and
application circuit examples, is current as of the date this document is issued. Such information, however, is
subject to change without any prior notice. Before purchasing or using any Renesas products listed in this
document, please confirm the latest product information with a Renesas sales office. Also, please pay regular
and careful attention to additional and different information to be disclosed by Renesas such as that disclosed
5. Renesas has used reasonable care in compiling the information included in this document, but Renesas
assumes no liability whatsoever for any damages incurred as a result of errors or omissions in the information
included in this document.
6. When using or otherwise relying on the information in this document, you should evaluate the information in
light of the total system before deciding about the applicability of such information to the intended application.
Renesas makes no representations, warranties or guaranties regarding the suitability of its products for any
particular application and specifically disclaims any liability arising out of the application and use of the
information in this document or Renesas products.
7. With the exception of products specified by Renesas as suitable for automobile applications, Renesas
products are not designed, manufactured or tested for applications or otherwise in systems the failure or
malfunction of which may cause a direct threat to human life or create a risk of human injury or which require
especially high quality and reliability such as safety systems, or equipment or systems for transportation and
traffic, healthcare, combustion control, aerospace and aeronautics, nuclear power, or undersea communication
transmission. If you are considering the use of our products for such purposes, please contact a Renesas
sales office beforehand. Renesas shall have no liability for damages arising out of the uses set forth above.
8. Notwithstanding the preceding paragraph, you should not use Renesas products for the purposes listed below:
(1) artificial life support devices or systems
(2) surgical implantations
(3) healthcare intervention (e.g., excision, administration of medication, etc.)
(4) any other purposes that pose a direct threat to human life
Renesas shall have no liability for damages arising out of the uses set forth in the above and purchasers who
elect to use Renesas products in any of the foregoing applications shall indemnify and hold harmless Renesas
Technology Corp., its affiliated companies and their officers, directors, and employees against any and all
damages arising out of such applications.
9. You should use the products described herein within the range specified by Renesas, especially with respect
to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation
characteristics, installation and other product characteristics. Renesas shall have no liability for malfunctions or
damages arising out of the use of Renesas products beyond such specified ranges.
10. Although Renesas endeavors to improve the quality and reliability of its products, IC products have specific
characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use
conditions. Please be sure to implement safety measures to guard against the possibility of physical injury, and
injury or damage caused by fire in the event of the failure of a Renesas product, such as safety design for
hardware and software including but not limited to redundancy, fire control and malfunction prevention,
appropriate treatment for aging degradation or any other applicable measures. Among others, since the
evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or
system manufactured by you.
11. In case Renesas products listed in this document are detached from the products to which the Renesas
products are attached or affixed, the risk of accident such as swallowing by infants and small children is very
high. You should implement safety measures so that Renesas products may not be easily detached from your
products. Renesas shall have no liability for damages arising out of such detachment.
12. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written
approval from Renesas.
13. Please contact a Renesas sales office if you have any questions regarding the information contained in this
document, Renesas semiconductor products, or if you have any other inquiries.
Rev. 2.00 Sep. 08, 2008 Page iii of vi
REJ10J1868-0200
Rev. 2.00 Sep. 08, 2008 Page iv of iv
REJ10J1868-0200
IMPORTANT INFORMATION
READ FIRST
• READ this user's manual before using this user system interface board.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface board until you fully understand its
mechanism.
User System Interface Board:
Throughout this document, the term "user system interface board" shall be defined as the
following product produced only by Renesas Technology Corp. excluding all subsidiary products.
•
User system interface board (HS1658RECN61H)
The user system or a host computer is not included in this definition.
Purpose of the User System Interface Board:
This user system interface board is for connecting the evaluation chip board and user system.
This user system interface board must only be used for the above purpose.
Improvement Policy:
Renesas Technology Corp. (including its subsidiaries, hereafter collectively referred to as
Renesas) pursues a policy of continuing improvement in design, performance, functions, and
safety of the user system interface board. Renesas reserves the right to change, wholly or
partially, the specifications, design, user's manual, and other documentation at any time without
notice.
Target User of the User System Interface Board:
This user system interface board should only be used by those who have carefully read and
thoroughly understood the information and restrictions contained in the user's manual. Do not
attempt to use the user system interface board until you fully understand its mechanism.
It is highly recommended that first-time users be instructed by users that are well versed in the
operation of the user system interface board.
Rev. 2.00 Sep. 08, 2008 Page I of X
REJ10J1868-0200
LIMITED WARRANTY
Renesas warrants its user system interface boards to be manufactured
in accordance with published specifications and free from defects in
material and/or workmanship. Renesas will repair or replace any
user system interface boards determined to be defective in material
and/or workmanship. User system interface boards are wearing parts
which Renesas will not repair or replace if damaged and/or worn
through use. The foregoing shall constitute the sole remedy for any
breach of Renesas’ warranty. This warranty extends only to you, the
original Purchaser. It is not transferable to anyone who subsequently
purchases the user system interface board from you. Renesas is not
liable for any claim made by a third party or made by you for a third
party.
DISCLAIMER
RENESAS MAKES NO WARRANTIES, EITHER EXPRESS OR
IMPLIED, ORAL OR WRITTEN, EXCEPT AS PROVIDED
HEREIN, INCLUDING WITHOUT LIMITATION THEREOF,
WARRANTIES AS TO MARKETABILITY, MERCHANTABILITY,
FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR
AGAINST INFRINGEMENT OF ANY PATENT. IN NO EVENT
SHALL RENESAS BE LIABLE FOR ANY DIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR
LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE
USER SYSTEM INTERFACE BOARD, THE USE OF ANY USER
SYSTEM INTERFACE BOARD, OR ITS DOCUMENTATION,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS
WARRANTY, THIS USER SYSTEM INTERFACE BOARD IS SOLD
"AS IS ", AND YOU MUST ASSUME ALL RISK FOR THE USE
AND RESULTS OBTAINED FROM THE USER SYSTEM
INTERFACE BOARD.
Rev. 2.00 Sep. 08, 2008 Page II of X
REJ10J1868-0200
State Law:
Some states do not allow the exclusion or limitation of implied warranties or liability for
incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which may vary from
state to state.
The Warranty is Void in the Following Cases:
Renesas shall have no liability or legal responsibility for any problems caused by misuse,
abuse, misapplication, neglect, improper handling, installation, repair or modifications of the user
system interface board without Renesas’ prior written consent or any problems caused by the user
system.
All Rights Reserved:
This user's manual and user system interface board are copyrighted and all rights are reserved
by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any
form, in hard-copy or machine-readable form, by any means available without Renesas’ prior
written consent.
Other Important Things to Keep in Mind:
1. Circuitry and other examples described herein are meant merely to indicate the characteristics
and performance of Renesas’ semiconductor products. Renesas assumes no responsibility for
any intellectual property claims or other problems that may result from applications based on
the examples described herein.
2. No license is granted by implication or otherwise under any patents or other rights of any third
party or Renesas.
Figures:
Some figures in this user's manual may show items different from your actual system.
Limited Anticipation of Danger:
Renesas cannot anticipate every possible circumstance that might involve a potential hazard.
The warnings in this user's manual and on the user system interface board are therefore not all
inclusive. Therefore, you must use the user system interface board safely at your own risk.
Rev. 2.00 Sep. 08, 2008 Page III of X
REJ10J1868-0200
SAFETY PAGE
READ FIRST
• READ this user's manual before using this user system interface board.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface board until you fully understand its
mechanism.
DEFINITION OF SIGNAL WORDS
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
DANGER indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
CAUTION
CAUTION used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, may result
in property damage.
NOTE emphasizes essential information.
Rev. 2.00 Sep. 08, 2008 Page IV of X
REJ10J1868-0200
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Do not repair or remodel the emulator product by
yourself for electric shock prevention and quality
assurance.
2. Always switch OFF the E6000H emulator and user system
before connecting or disconnecting any CABLES or
PARTS.
3. Always before connecting any BOARDS, make sure that
pin 1 on both sides are correctly aligned.
Rev. 2.00 Sep. 08, 2008 Page V of X
REJ10J1868-0200
Rev. 2.00 Sep. 08, 2008 Page VI of X
REJ10J1868-0200
Preface
The HS1658RECN61H is a user system interface board that connects a user system for the
H8SX/1658R PLQP0120LA-A (former code: FP-120B) package to the H8SX/1650 E6000H
emulator (HS1650EPH60H). Emulation of the H8SX/1658R group is only possible when this user
system interface board is connected to the HS1650EPH60H.
Rev. 2.00 Sep. 08, 2008 Page VII of X
REJ10J1868-0200
Rev. 2.00 Sep. 08, 2008 Page VIII of X
REJ10J1868-0200
Contents
Section 1 Configuration........................................................................................1
Section 2 Connection Procedures ..........................................................................3
2.1 Connecting the User System Interface Board to the User System......................................... 3
2.1.1 Installing the IC Socket............................................................................................. 4
2.1.2 Soldering the IC Socket ............................................................................................ 5
2.1.3 Inserting the IC Socket Connector............................................................................ 5
2.1.4 Fastening the IC Socket Connector........................................................................... 6
2.2 Exchanging the Spacers of the Evaluation-Chip Board......................................................... 8
2.3 Connecting the User System Interface Board to the Evaluation-Chip Board ........................ 9
2.4 Recommended Dimensions for the User System Mounting Pad (Footprint)....................... 11
2.5 Dimensions of the Evaluation-Chip Board and the User System Interface Board............... 12
2.6 Dimensions after Connecting the User System Interface Board.......................................... 13
2.7 Using the Emulator without Connecting User System......................................................... 14
Section 3 Installing the MCU on the User System ..............................................17
Section 4 User System Interface Circuits ............................................................19
Section 5 Verifying Operation.............................................................................25
Section 6 Points for Caution ................................................................................27
Section 7 Restrictions ..........................................................................................29
Rev. 2.00 Sep. 08, 2008 Page IX of X
REJ10J1868-0200
Rev. 2.00 Sep. 08, 2008 Page X of X
REJ10J1868-0200
Section 1 Configuration
Section 1 Configuration
Figure 1 and table 1 show the external appearance and components, respectively, of the user
system interface board for the PLQP0120LA-A package. Please make sure you have all of these
components after you have unpacked the box.
Evaluation-chip board
Screws (M2 × 6 mm)
Spacer
Screws (M2 × 10 mm)
(for fastening the board)
Socket cover
User system
interface board
IC socket
User system
Figure 1 H8SX/1658R PLQP0120LA-A User System Interface Board
Rev. 2.00 Sep. 08, 2008 Page 1 of 30
REJ10J1868-0200
Section 1 Configuration
CAUTION
Use an NQPACK120SE-ND socket and an HQPACK120SE
cover (manufactured by Tokyo Eletech Corporation) for the
PLQP0120LA-A-packaged IC socket on the user system.
Table 1
HS1658RECN61H Components
Quantity Remarks
No. Component
1
2
User system interface
board
1
IC socket
1
For the PLQP0120LA-A package (to be mounted on
the user system)
3
4
5
6
7
8
9
Socket cover
1
4
4
For installing a PLQP0120LA-A-packaged MCU
For fastening the board
Screws (M2 x 10 mm)
Screws (M2 x 6 mm)
For installing a PLQP0120LA-A-packaged MCU
Spacers (2.6MP x 25 mm) 2
Spacers (2.6MQ x 13 mm) 4
Screwdriver
1
3
1
For tightening screws
Guide pins (φ1 mm)
For determining the IC socket location
User’s manual for HS1658RECN61H (this manual)
10 Documentation
Rev. 2.00 Sep. 08, 2008 Page 2 of 30
REJ10J1868-0200
Section 2 Connection Procedures
Section 2 Connection Procedures
2.1
Connecting the User System Interface Board to the User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE BOARD
is connected or removed. Before connecting the two, make
sure that pin 1 on both sides are correctly aligned. Failure to
do so will result in a FIRE HAZARD and will damage the
user system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be LOST.
CAUTION
To connect the emulator to the user system, ensure that
the SW1 jumper pin is inserted to [USER-ON].
Failure to do so will damage the emulator product, user
system interface board, and user system.
Rev. 2.00 Sep. 08, 2008 Page 3 of 30
REJ10J1868-0200
Section 2 Connection Procedures
To connect the board to the user system, follow the instructions below.
2.1.1
Installing the IC Socket
After checking the location of pin 1 on the IC socket fasten it to the user system before soldering.
CAUTION
After confirming the location of pin 1 on the IC socket,
apply epoxy resin adhesive to the end of the four projections
at the bottom of the IC socket, and fasten it to the user
system.
Use the guide pins provided with the product to determine where to install the IC socket, as shown
in figure 2. When connecting the socket to the user system interface board, remove the guide pins.
Guide pins
4 projections to apply
epoxy resin adhesive to
Pin 1
IC socket
(NQPACK120SE-ND manufactured
by Tokyo Eletech Corporation)
Bottom view of IC socket
User system
Figure 2 Correctly Placing the IC Socket
Rev. 2.00 Sep. 08, 2008 Page 4 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.1.2
Soldering the IC Socket
After fastening, solder the IC socket for a PLQP0120LA-A package to the user system.
CAUTION
Be sure to completely solder the leads so that the solder
gently covers the leads and forms solder fillets. (Use
slightly more solder than with the MCU.)
2.1.3
Inserting the IC Socket Connector
CAUTION
Check the location of pin 1 before inserting.
After checking the location of pin 1 on the user system interface board and pin 1 on the IC socket
connector, align the guide pins on the IC socket connector with the guide holes on the user system
interface board, and insert the IC socket connector into the IC socket (figure 3).
Rev. 2.00 Sep. 08, 2008 Page 5 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.1.4
Fastening the IC Socket Connector
CAUTION
1. Use the screwdriver provided for tightening screws.
2. The tightening torque must be 0.054 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
Fasten the user system interface board to the IC socket for a PLQP0120LA-A package on the user
system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a
time, alternating between screws on opposing corners. Take special care, such as manually
securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by
overtightening the screws or twisting the components.
Rev. 2.00 Sep. 08, 2008 Page 6 of 30
REJ10J1868-0200
Section 2 Connection Procedures
Screws (M2 × 10 mm)
(for fastening the board)
User system interface board
Pin 1
IC socket
(NQPACK120SE-ND
manufactured by
Tokyo Eletech Corporation)
User system
Figure 3 Connecting the User System Interface Board to the User System
Rev. 2.00 Sep. 08, 2008 Page 7 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.2
Exchanging the Spacers of the Evaluation-Chip Board
After connecting the user system interface board to the user system, be careful not to apply load to
the user system.
Exchange the spacers (2.6MP × 10 mm) of the evaluation-chip board with the spacers (2.6MP × 25
mm) provided with the user system interface board and adjust the height.
Evaluation-chip board
Spacer
(2.6MP × 25 mm)
Figure 4 Exchanging the Spacers
Rev. 2.00 Sep. 08, 2008 Page 8 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.3
Connecting the User System Interface Board to the Evaluation-Chip
Board
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE BOARD
is connected or removed. Before connecting the two,
make sure that the pin 1 positions on both sides are
correctly aligned.
2. The user system interface board must be used with the
emulator for which it was designed.
1. Make sure the user system and emulator are turned off.
2. Align the connectors on the user system interface board with those on the evaluation-chip board
by matching the numbers on the connectors (figure 5).
3. Adjust the height of the spacers of the evaluation-chip board to accommodate the user system.
Rev. 2.00 Sep. 08, 2008 Page 9 of 30
REJ10J1868-0200
Section 2 Connection Procedures
Evaluation-chip board
Connector No.
Evaluation-Chip
Board
Connector No.
Board
Connector No.
UCN1
UCN2
UCN1
UCN2
User system interface board
Figure 5 Connecting the User System Interface Board to the Evaluation-Chip Board
Rev. 2.00 Sep. 08, 2008 Page 10 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.4
Recommended Dimensions for the User System Mounting Pad
(Footprint)
Figure 6 shows the recommended dimensions for the mounting pad (footprint) for the user system
with the IC socket for a PLQP0120LA-A package (NQPACK120SE-ND: manufactured by Tokyo
Eletech Corporation). The dimensions in figure 6 are somewhat different from those of the mounting
pad for the system with the actual MCU. Also, note the user system can not be connected to the user
system interface board with inserting the guide pins in place.
0.40 x 29 = 11.6
0.40 0.05 = 0.2
3.0 - φ1.0
5.8
Dimension and tolerance
Dimension
Up to 1.2
Tolerance
0.05
1.3 to 2.0
0.10
2.1 to 5.0
0.15
5.1 to 10.0
10.1 or above
0.20
0.30
Unit: mm
Figure 6 Recommended Dimensions for the Mounting Pad
Rev. 2.00 Sep. 08, 2008 Page 11 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.5
Dimensions of the Evaluation-Chip Board and the User System
Interface Board
The dimensions of the evaluation-chip board and the user system interface board are shown in
figure 7.
140.0
Evaluation-chip board
118.5
78.5
Unit: mm
User system interface board
Tolerance: 0.5 mm
Figure 7 Dimensions of the Evaluation-Chip Board and the User System Interface Board
Rev. 2.00 Sep. 08, 2008 Page 12 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.6
Dimensions after Connecting the User System Interface Board
The dimensions of the assembly after the user system interface board has been connected to the user
system are shown in figure 8.
Evaluation-chip board
56.5
IC socket
(NQPACK120SE-ND
manufactured by
Tokyo Eletech Corporation)
Spacer (φ5.8)
User system
56.5
Unit: mm
Tolerance: 1.0 mm
Figure 8 Dimensions of the Assembly after Connection of the User System Interface Board
Rev. 2.00 Sep. 08, 2008 Page 13 of 30
REJ10J1868-0200
Section 2 Connection Procedures
2.7
Using the Emulator without Connecting User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE BOARD
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are correctly
aligned. Failure to do so will result in a FIRE HAZARD and
will damage the user system and the emulator product or
will result in PERSONAL INJURY. The USER PROGRAM will
be LOST.
CAUTION
When this emulator is used without connecting to the
user system, ensure that the SW1 jumper pin is inserted to
[USER-OFF]. Failure to do so will damage the emulator
product, user system interface board, and user system.
Attach the provided spacers (2.6MQ x 13 mm) to four positions on the user system interface board
not to apply loads to the connector (CN1) on the board.
Rev. 2.00 Sep. 08, 2008 Page 14 of 30
REJ10J1868-0200
Section 2 Connection Procedures
USER OFF
USER ON
Figure 9 SW1 Jumper Socket
Spacer
(2.6MQ x 13 mm)
Figure 10 Attaching Spacers
Rev. 2.00 Sep. 08, 2008 Page 15 of 30
REJ10J1868-0200
Section 2 Connection Procedures
Rev. 2.00 Sep. 08, 2008 Page 16 of 30
REJ10J1868-0200
Section 3 Installing the MCU on the User System
Section 3 Installing the MCU on the User System
CAUTION
1. Check the location of pin 1 before inserting the MCU.
2. Use a screwdriver whose head matches the screw head.
3. The tightening torque must be 0.054 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
4. If the MCU does not operate correctly, cracks might have
occurred in the solder. Check conduction with a tester
and re-solder the IC socket if necessary.
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as
shown in figure 11. After inserting the MCU, fasten the socket cover with the four screws (M2.0
x 6 mm) provided for this. Take special care, such as by manually securing the IC socket soldered
area, to prevent the IC socket from being damaged by overtightening the screws or twisting the
components.
Rev. 2.00 Sep. 08, 2008 Page 17 of 30
REJ10J1868-0200
Section 3 Installing the MCU on the User System
Screws (M2.0 x 6 mm)
Socket cover
(HQPACK120SE
manufactured by
Tokyo Eletech Corporation)
MCU
Pin 1
IC socket
(NQPACK120SE-ND
manufactured by
Tokyo Eletech Corporation)
User system
Figure 11 Installing the MCU on the User System
Rev. 2.00 Sep. 08, 2008 Page 18 of 30
REJ10J1868-0200
Section 4 User System Interface Circuits
Section 4 User System Interface Circuits
The following user system interface circuits are required to use the emulator with the user system
interface board.
MCU
User system
SN74CBTLV3257
PD0-PD7
PE0-PE7
PD0-PD7 (PJ0-PJ7)
PE0-PE7 (PK0-PK7)
SN74CB3Q3306A
PJ2, PJ3
PK2-PK7
Vcc
PJ0
PJ1
PJ4
47 kΩ SN74CB3Q3306A
PJ5
PJ6
PJ7
PK0
PK1
Sub-MCU
TIOCA6
TIOCB6
TIOCA7
TIOCB7
TIOCA8
TIOCB8
TIOCA9
TIOCB9
PO16-PO23
PO24-PO31
Figure 12 User System Interface Circuit (1)
Rev. 2.00 Sep. 08, 2008 Page 19 of 30
REJ10J1868-0200
Section 4 User System Interface Circuits
User system
Vcc
MCU
47 kΩ
P20
P21
P20
P21
Sub-MCU
TIOCA3
TIOCB3
Figure 13 User System Interface Circuit (2)
Rev. 2.00 Sep. 08, 2008 Page 20 of 30
REJ10J1868-0200
Section 4 User System Interface Circuits
Vcc
User system
MCU
SN74CB3Q3306A
47 kΩ
P16
P15
P14
P16
Vcc
47 kΩ
P15
SN74CB3Q3306A
P14
Sub-MCU
SCK5
RxD5
TxD5
Figure 14 User System Interface Circuit (3)
Rev. 2.00 Sep. 08, 2008 Page 21 of 30
REJ10J1868-0200
Section 4 User System Interface Circuits
Sub-MCU
Vcc
User system
MD_CLK
LPT16244
Monitoring circuit
47 kΩ
MD_CLK
PM0-PM4
VBUS
PM0-PM4
VBUS
1 kΩ
DrVcc
USD-
USD+
DrVss
DrVcc
USD-
USD
DrVss
Figure 15 User System Interface Circuit (4)
Note: The power-supply circuit shown above is turned on/off by the setting of the SW1 jumper
pin on HS1658RECN61H. Ensure that the jumper pin is inserted to [ON] on
HS1658RECN61H when connecting the emulator (with HS1658RECN61H attached) to
the user system or supplying power to DrVCC. Otherwise the emulator product, user
system interface board, and user system will be damaged.
Rev. 2.00 Sep. 08, 2008 Page 22 of 30
REJ10J1868-0200
Section 4 User System Interface Circuits
User system
Vcc
MCU
EPM7128
UHC14
VHC244
47 kΩ
_RES
_RES
EPM7128
Figure 16 User System Interface Circuit (5)
User system
Vcc
MCU
10 kΩ
P13
P13
EPM3256ATC
Sub-MCU
ADTRGH0
Figure 17 User System Interface Circuit (6)
Rev. 2.00 Sep. 08, 2008 Page 23 of 30
REJ10J1868-0200
Section 4 User System Interface Circuits
Rev. 2.00 Sep. 08, 2008 Page 24 of 30
REJ10J1868-0200
Section 5 Verifying Operation
Section 5 Verifying Operation
1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H
Emulator User's Manual (HS1650EPH60HE).
2. Verify the user system interface cable connections by checking the pin states with the
EXMONITOR_DISPLAY command (emulator command) and checking the bus states with
the MEMORY_FILL command (emulator command). If an error is detected, recheck the
soldered IC socket and the location of pin 1.
3. The emulator connected to this user system interface board supports three kinds of clock
sources as the MCU clock. For details, refer to the H8SX/1650 E6000H Emulator User's
Manual (HS1650EPH60HE).
⎯ To use the emulator internal clock
Select the clock in the emulator by the CLOCK command (emulator command).
⎯ To use the external clock on the user system
Supply the external clock from the user system to the emulator by inputting the signal to
the EXTAL pin (pin 84) on the user system interface board or connecting a crystal
oscillator to the XTAL (pin 83) and EXTAL pins. For details, refer to the H8SX/1658R
Group Hardware Manual.
Figure 18 shows the clock oscillator on the user system interface board.
HCU04
1 MΩ
HCU04 HCU04
HCU04
HCU04
0 Ω
To E6000H
emulator
HCU04
270 Ω
EXTAL XTAL
System clock
Figure 18 Clock Oscillator
Rev. 2.00 Sep. 08, 2008 Page 25 of 30
REJ10J1868-0200
Section 5 Verifying Operation
⎯ To use the crystal resonator mounted on the evaluation-chip board
Install the crystal resonator into the crystal resonator terminals on the evaluation-chip
board.
Enlarged
view
Crystal
resonator
X1
X2
Crystal resonator terminals
Evaluation-chip
board
Figure 19 Mounting the Crystal Resonator
Rev. 2.00 Sep. 08, 2008 Page 26 of 30
REJ10J1868-0200
Section 6 Points for Caution
Section 6 Points for Caution
1. Before connecting any parts or cables, make sure that the pins at the pin 1 position on both
sides are correctly aligned.
2. Do not apply excessive force to the user system interface board while it is connected to the
user system.
3. The dimensions of the recommended mounting pad for the IC socket for this user system
interface board are different from those of the pad for the MCU.
4. This user system interface board is specifically designed for the HS1650EPH60H emulator.
Do not use this board with any other emulator.
5. When power is not being supplied to the Vcc pin on the user system interface board, the
emulator displays ** VCC DOWN. In this situation, the emulator will not operate correctly.
6. The P1 and SW3 jumper sockets are for use in testing. Do not remove the inserted jumpers.
Do not remove the jumpers.
USER OFF
USER ON
Port J, K
Port D, E
SYNC
ASYNC
Figure 20 P1 and SW3 Jumper Sockets
Rev. 2.00 Sep. 08, 2008 Page 27 of 30
REJ10J1868-0200
Section 6 Points for Caution
Rev. 2.00 Sep. 08, 2008 Page 28 of 30
REJ10J1868-0200
Section 7 Restrictions
Section 7 Restrictions
1. Deep-software standby mode
This emulator does not support deep-software standby mode.
Note that the emulator switches to the software standby mode even if the register setting to
select the deep-software standby mode is made.
2. Sleep-instruction exception processing
This emulator does not support the processing of sleep-instruction exceptions. Even if the
SLPIE bit of the standby control register (SBYCR) is set to 1, the execution of a sleep
instruction simply makes the emulator enter the low-power-consumption mode with no
exception processing for the sleep instruction.
3. User break controller (UBC)
The user break controller (UBC) is not available for this emulator.
Do not access the registers for the UBC, which are at addresses H’FFA00 to H’FFA34.
4. Serial communications interface (SCI5)
Since the port functions of pins P14 and P16 are not available when they are in use for serial
output, the states of these port pins cannot be read from the port registers. In this situation, the
input pull-up MOS and open-drain output functions are also not available.
5. Input-buffer control registers (PnICR)
In the actual device, setting a given bit of a PnICR to 0 disables the input buffer and fixes the
input signal to the high level; setting a given bit to 1 makes the corresponding pin available as
an input pin. On the emulator, however, input is enabled regardless of the settings of bits in the
ICR register.
When using any of the peripheral modules indicated below, however, ensure that the user
program has set the ICR bit for the corresponding pin to 1.
Relevant peripheral modules: SCI5 and ADC_Unit1
6. Port function control register D (PFCRD)
In this emulator, the port J and K functions cannot be selected by controlling the PCJKE bit in
the register PFCRD. A value read from PFCRD is always 0 and writing to PFCRD has no
effect. To select ports J and K, the position of the jumper in SW2 on HS1658RECN61H must
be altered (figure 19). In the product as shipped, the jumper is inserted to select ports D and E.
Rev. 2.00 Sep. 08, 2008 Page 29 of 30
REJ10J1868-0200
Section 7 Restrictions
7. A/D converter
In the emulator, the evaluation chip and the slave chip are used to implement functions of Unit
0 and Unit 1, respectively, of the A/D converter. For this reason, when the A/D control register
(ADCR) has been set to start A/D conversion (with synchronization of units) by an external
trigger from the ADTRG0 pin, the interrupt timing at the end of the A/D conversion will be
different between Unit 0 and Unit 1.
8. Clock Input to the USB Module
While using the emulator, the frequency of the clock signal supplied to the USB module is
fixed to 48 MHz regardless of the EXTAL input by the user.
Rev. 2.00 Sep. 08, 2008 Page 30 of 30
REJ10J1868-0200
H8SX/1658R Group E6000H PLQP0120LA-A
User System Interface Board
HS1658RECN61H User's Manual
Publication Date: Rev.2.00, September 8, 2008
Published by:
Sales Strategic Planning Div.
Renesas Technology Corp.
Edited by:
Customer Support Department
Global Strategic Communication Div.
Renesas Solutions Corp.
© 2008. Renesas Technology Corp., All rights reserved. Printed in Japan.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan
RENESAS SALES OFFICES
Renesas Technology America, Inc.
450 Holger Way, San Jose, CA 95134-1368, U.S.A
Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501
Renesas Technology Europe Limited
Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
Tel: <44> (1628) 585-100, Fax: <44> (1628) 585-900
Renesas Technology (Shanghai) Co., Ltd.
Unit 204, 205, AZIACenter, No.1233 Lujiazui Ring Rd, Pudong District, Shanghai, China 200120
Tel: <86> (21) 5877-1818, Fax: <86> (21) 6887-7858/7898
Renesas Technology Hong Kong Ltd.
7th Floor, North Tower, World Finance Centre, Harbour City, Canton Road, Tsimshatsui, Kowloon, Hong Kong
Tel: <852> 2265-6688, Fax: <852> 2377-3473
Renesas Technology Taiwan Co., Ltd.
10th Floor, No.99, Fushing North Road, Taipei, Taiwan
Tel: <886> (2) 2715-2888, Fax: <886> (2) 3518-3399
Renesas Technology Singapore Pte. Ltd.
1 Harbour Front Avenue, #06-10, Keppel Bay Tower, Singapore 098632
Tel: <65> 6213-0200, Fax: <65> 6278-8001
Renesas Technology Korea Co., Ltd.
Kukje Center Bldg. 18th Fl., 191, 2-ka, Hangang-ro, Yongsan-ku, Seoul 140-702, Korea
Tel: <82> (2) 796-3115, Fax: <82> (2) 796-2145
Renesas Technology Malaysia Sdn. Bhd
Unit 906, Block B, Menara Amcorp, Amcorp Trade Centre, No.18, Jln Persiaran Barat, 46050 Petaling Jaya, Selangor Darul Ehsan, Malaysia
Tel: <603> 7955-9390, Fax: <603> 7955-9510
Colophon 6.2
H8SX/1658R Group E6000H
PLQP0120LA-A
User System Interface Board
HS1658RECN61H User’s Manual
|