IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and con-
form to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclo-
sure, it is designed for indoor use only and it must not be installed where exposed to
rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. For marine applications, the installation shall be in accordance with the Electrical Engi-
neering Regulations of the USCG, Subpart J, C.G. 259 (46 CFR Parts 110-113).
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
C A U T I O N :
within this unit.
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are impor-
tant operating and maintenance instructions
in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
DESCRIPTION
The heater and blower kits described in this manual are intended to work with the EHX*E
Series of non-pressurized, explosion-proof camera enclosures.
When installing heater and blower kits in EHX*E Series explosion-proof camera enclosures,
the maximum camera and lens sizes are reduced depending on the size of the blower, heater
brackets, and PC board(s). Before installing the heater and blower kit, verify that the camera
currently installed in the enclosure will fit in the enclosure after installation of the accessories
(refer to the Specifications section in this manual).
BLOWER AND HEATER KITS
BKX4000
BKX4024
BKX6000
BKX6000/220
BKX6024
HKX4-1
Continuously run blower kit, 120 VAC, 3.8 watts, 10 cfm @ 60 Hz. For use
with EHX4E enclosure only.
Continuously run blower kit, 24 VAC (AC rectified), 1.92 watts, 19.4
cfm. For use with EHX4E enclosure only. (CE)
Continuously run blower kit, 120 VAC, 3.8 watts, 10 cfm @ 60 Hz. For use
with EHX6E, EHX6E-16, EHX8E, EHX10E enclosures.
Continuously run blower kit, 230 VAC, 9.6 watts, 8 cfm @ 50 Hz. For use
with EHX6E, EHX6E-16, EHX8E, EHX10E enclosures. (CE)
Continuously run blower kit, 24 VAC (AC rectified), 1.92 watts, 19.4 cfm.
For use with EHX6E, EHX6E-16, EHX8E, EHX10E enclosures. (CE)
Thermostatically controlled heater kit, 120 VAC, 40 watts, for EHX4E
enclosure only.
NOTE: Blower kits are not
thermostatically controlled.
HKX4-2
HKX4-3
HKX6-1
Same as HKX4-1 except 24 VAC. (CE)
Same as HKX4-1 except 230 VAC. (CE)
Thermostatically controlled heater kit, 120 VAC, 80 watts, for EHX6E
and EHX6E-16 enclosures only.
HKX6-2
Same as HKX6-1 except 24 VAC. (CE)
HKX6-3
Same as HKX6-1 except 230 VAC. (CE)
HKX8/10-1
Thermostatically controlled heater kit, 120 VAC, 100 watts, for EHX8E
and EHX10E enclosures only.
HKX8/10-2
HKX8/10-3
Same as HKX8/10-1 except 24 VAC, 40 watts. (CE)
Same as HKX8/10-1 except 230 VAC, 100 watts. (CE)
4
Pelco Manual C1495M-B (10/03)
INSTALLATION
HEATER KIT INSTALLATION
The following items are supplied:
WARNING: Do
not remove the
Assembly, including heater bracket, PC board bracket, heaters, and PC board
Hardware to attach the heater and PC board brackets to the enclosure:
front cover. If you
do, Pelco cannot be held re-
sponsible for the loss of ex-
plosion-proof rating, UL list-
ing, or ability of the enclo-
sure to contain an explosion.
HKX4
HKX6 HKX8/10
3/8-inch screws
Nuts
Internal tooth lock washers
6
2
6
4
2
4
4
2
4
Heater kits are partially assembled. If you are installing both heater and blower kits, see the
instructions in the Heater Kit and Blower Kit Installation section. Do the following to install
any heater kit:
1. Disconnect all sources of power from the enclosure.
2. Remove the enclosure’s rear plate with a 5 mm Allen wrench.
3. Remove the camera sled and camera from the enclosure.
a. Use a 3/16-inch Allen wrench to loosen the set screw that holds the camera sled
in place.
b. Partially pull the camera sled out; disconnect the camera’s power wires and video
cable.
c. Remove the camera sled from the enclosure.
d. Remove the camera from the sled.
4. Disconnect the heater wires from the PC board.
5. Attach the PC board bracket to the enclosure’s rear plate using the hardware provided
(refer to Figure 1 or 2).
6. Attach the heater bracket to the front of the camera sled using the hardware provided
(refer to Figure 3 or 4).
7. Reinstall the camera and camera sled, but do not tighten the set screw that holds the
sled in place.
8. Attach the video cable to the camera.
9. Reconnect the heater wires to the PC board (refer to Figure 8).
10. If the camera uses a different voltage than the heater, reconnect the power wires to
the camera. If the camera uses the same voltage as the heater, proceed to the next step.
11. Bring power wires through the rear plate and connect the wires to the PC board (refer
to Figure 8). If you are installing the HKX4-2, HKX6-2, or HKX8/10-2 heater kit, refer to
Table A, 24 VAC Wiring Distances. If the camera uses the same voltage as the heater,
the camera power consumption must be considered when determining the wire gauge.
Table A does not include camera power because of the many variations.
12. Tighten the set screw that holds the camera sled in place.
13. Reinstall the rear plate of the enclosure. Apply Loctite® 222 low-strength thread locker
(not supplied) to the screws to prevent them from seizing.
Pelco Manual C1495M-B (10/03)
5
BLOWER KIT INSTALLATION
The following items are supplied:
Assembly, including blower and bracket.
Hardware to attach the blower, bracket, and PC board (24 VAC only) to the enclosure:
NOTE: The 24 VAC and the
230 VAC versions use addi-
tional components that should
be secured to the fan bracket
with the integrated clip in the
bracket.
BKX4000 BKX4024 BKX6000/220
3/8-inch screws
Internal tooth lock washers
Nuts
2
2
0
2
2
2
0
2
2
2
2
2
Butt splices
Blower kits are partially assembled. If you are installing both heater and blower kits, see the
instructions in Heater Kit and Blower Kit Installation section. Do the following to install any
blower kit:
1. Disconnect all sources of power from the enclosure.
2. Remove the enclosure’s rear plate with a 5 mm Allen wrench.
3. Attach the blower assembly to the enclosure’s rear plate using the hardware provided
(refer to Figure 5, 6, or 7).
4. Bring power wires through the rear plate and connect the AC input wiring to the blower
wires with the butt splices that are provided (refer to Figure 8).
5. Reinstall the rear plate of the enclosure. Apply Loctite® 222 low-strength thread locker
(not supplied) to the screws to prevent them from seizing.
6
Pelco Manual C1495M-B (10/03)
HEATER KIT AND BLOWER KIT INSTALLATION
Do the following to install both the heater and blower kits:
1. Disconnect all sources of power from the enclosure.
2. Remove the enclosure’s rear plate with a 5 mm Allen wrench.
3. Remove the camera sled and camera from the enclosure.
a. Use a 3/16-inch Allen wrench to loosen the set screw that holds the camera sled
in place.
b. Partially pull the camera sled out; disconnect the camera’s power wires and video
cable.
c. Remove the camera sled from the enclosure.
d. Remove the camera from the sled.
4. Disconnect the heater wires from the PC board.
5. Remove the blower from the bracket; keep the hardware attaching the blower to the
bracket and discard the bracket.
6. Attach the blower to the bracket on which the PC board for the heater is attached.
7. Attach the PC board and blower bracket to the enclosure’s rear cover the hardware
provided (refer to Figures 1 and 2).
8. Attach the heater bracket to the front of the camera sled using the hardware provided
(refer to Figures 3 and 4).
9. Reinstall the camera and sled; do not tighten the set screw that holds the sled in place.
10. Attach the video cable to the camera.
11. Reconnect the heater wires to the PC board (refer to Figure 8).
12. If the camera uses a different voltage than the heater, reconnect the power wires to
the camera. If the camera uses the same voltage as the heater, proceed to the next step.
13. Bring power wires through the rear plate and connect the wires to the PC board (refer
to Figure 8). If you are installing the HKX4-2, HKX6-2, or HKX8/10-2 heater kit, refer to
Table A, 24 VAC Wiring Distances. If the camera uses the same voltage as the heater,
the camera power consumption must be considered when determining the wire gauge.
Table A does not include camera power because of the many variations.
14. Tighten the set screw that holds the camera sled in place.
15. Reinstall the rear plate of the enclosure. Apply Loctite® 222 low-strength thread locker
(not supplied) to the screws to prevent them from seizing.
Pelco Manual C1495M-B (10/03)
7
A
B
1
2
3
C
B
A
Figure 1. HKX4 PC Board Installation
A
B
1
2
C
3
B
A
Figure 2. HKX6, HKX8/10 PC Board Installation
Table A. HKX4, HKX6, HKX8/10 Series PC Board Assembly Parts List
Item
Qty
Description
PC board
Part Number
1
2
3
1
1
1
PCB9000300ASSY
BK400010000
Insulator
PC board bracket
HKX4
E7044012COMP
BK40004000COMP
HKX6, HKX8/10
A
B
C
D
Screw, 6-32 x 3/8-inch
HKX4
HKX6, HKX8/10
Internal tooth lock washer, #6
HKX4
HKX6, HKX8/10
Nylon washer
HKX4
ZH6-32X.375SPP
4
6
ZH6LWSIS
4
6
ZH200X437X62N
570010004
2
4
1
HKX6, HKX8/10
Brass solder lug
(for grounding circuit board)
8
Pelco Manual C1495M-B (10/03)
A
1
B
C
Figure 3. EHX4E Heater Bracket Installation
1
A
B
C
Figure 4. EHX6E/8E/10E Heater Bracket Installation
Table B. HKX4, HKX6, HKX8/10 Series Heater Assembly Parts List
Item
Qty
Description
Heater Bracket
Part Number
1
1
HKX4 Series
HKX6, HKX8/10 Series
Heaters
E7044013COMP
E700H4010COMP
N/S*
2
HKX4-1, 120 VAC
HKX4-2, 24 VAC
HKX4-3, 230 VAC
HKX6-1, 120 VAC
HKX6-2, 24 VAC
HKX6-3, 230 VAC
HKX8/10-1, 120 VAC
HKX8/10-2, 24 VAC
HKX8/10-3, 230 VAC
HT71-04040100
HT72-04040100
HT73-04040100
HT07-0810-0402
HT07-0820-0402
HT07-0830-0402
HTR50120
HTR20024
HTR40220
A
B
C
2
2
2
Screw, 6-32 x 3/8-inch
Internal tooth lock washer, #6
Nut, 6-32, hex
ZH6-32X.375SPP
ZH6LWSIS
ZH6-32NUTSH
Pelco Manual C1495M-B (10/03)
9
A
B
1
BKX4024 ONLY
5
2
3
4
B
A
B
A
B
C
Figure 5. BKX4000, BKX4024 Blower Assembly Installation
Table C. BKX4000, BKX4024 Blower Assembly Parts List
Item
Qty
Description
Blower bracket
Blower bracket
Blower bracket
Blower
Part Number
1
2
3
4
1
1
1
1
BK7044002COMP
E7044012COMP
BK7044001COMP
BKX4000, 120 VAC
BKX4024, 24 VDC rectified
PC Board
MM750010003
ED210005
PCB9000277ASSY
5*
A
1
Screw, 6-32 x 3/8-inch
BKX4000
BKX4024
ZH6-32X.375SPP
6
7
B
C
Internal tooth lock washer, #6
BKX4000
BKX4024
ZH6LWSIS
7
8
1
Screw, 6-32 x 1 1/2-inch
ZH6-32X1.50SPS
* BKX4024 only
10
Pelco Manual C1495M-B (10/03)
BKX6000/220 ONLY
A
B
3
E
1
B
C
B
A
D
2
Figure 6. BKX6000, BKX6000/220 Blower Assembly Installation
Table D. BKX6000, BKX6000/220 Blower Assembly Parts List
Item
Qty
Description
Blower bracket
Blower
Blower bracket
Part Number
1
2
3*
1
1
1
BK40004000COMP
MM750010003
BK7044002COMP
A
B
C
D
E
6
8
2
2
4
Screw, 6-32 x 3/8-inch
Internal tooth lock washer, #6
Screw, 6-32 x 1 1/2-inch
Nut, 6-32, hex
ZH6-32X.375SPP
ZH6LWSIS
ZH6-32X1.50SPS
ZH6-32NUTSH
ZH200X437X62N
Nylon washer
* BKX6000/220 only
Pelco Manual C1495M-B (10/03)
11
1
B
C
B
A
3
B
D
A
BKX6024 ONLY
D
2
Figure 7. BKX6024 Blower Assembly Installation
Table E. BKX6024 Blower Assembly Parts List
Item
Qty
Description
Blower bracket
Blower, 24 VDC rectified
PC Board
Part Number
1
2
3
1
1
1
BK40004000COMP
ED210005
PCB9000277ASSY
A
B
C
D
3
4
1
2
Screw, 6-32 x 3/8-inch
Internal tooth lock washer, #6
Screw, 6-32 x 1 1/2-inch
Nut, 6-32, hex
ZH6-32X.375SPP
ZH6LWSIS
ZH6-32X1.50SPS
ZH6-32NUTSH
12
Pelco Manual C1495M-B (10/03)
AC
AC
GND
1
2
DIODE
CAPACITOR
RED
BLK
3
4
5
RED
BLK
AC IN
6
7
BLOWER
HEATER
HEATER
8
9
10
BLOWER
BUTT SPLICES
RECTIFIER
PC BOARD
RECTIFIER
PC BOARD
HEATER ONLY OR HEATER AND BLOWER
BLOWER ONLY
24 VAC WIRING DIAGRAM
AC
AC
GND
1
2
3
4
5
6
7
AC IN
BLOWER
HEATER
HEATER
8
9
10
BLOWER
BUTT SPLICES
HEATER ONLY OR HEATER AND BLOWER
BLOWER ONLY
120 VAC WIRING DIAGRAM
AC
AC
GND
1
2
3
4
5
AC IN
6
7
8
9
BLOWER
RESISTOR
BLOWER
HEATER
HEATER
BUTT SPLICES
RESISTOR
10
HEATER ONLY OR HEATER AND BLOWER
BLOWER ONLY
230 VAC WIRING DIAGRAM
Figure 8. Heater/Blower Kit Wiring Diagram
Pelco Manual C1495M-B (10/03)
13
Table F. Enclosure Accessory Wiring Distances
CAUTION: When a single power source is used for both the camera and accessories, the camera power con-
sumption must be considered when determining the wire gauge. However, the following chart does not include
camera power because of the many variations.
Power
Model Number
BKX4000
or
Input Voltage
Consumption
Cable Size
Cable Distance
120 VAC
4 watts
18 AWG
16 AWG
14 AWG
27,108 feet (8,262 m)
43,062 feet (13,125 m)
68,441 feet (20,860 m)
BKX6000
BKX4024
or
BKX6024
24 VAC
230 VAC
120 VAC
24 VAC
2 watts
10 watts
40 watts
40 watts
40 watts
80 watts
80 watts
80 watts
100 watts
40 watts
100 watts
18 AWG
16 AWG
14 AWG
2,169 feet
3,445 feet (1,050 m)
5,475 feet (1,669 m)
(661 m)
BKX6000/220
18 AWG
16 AWG
14 AWG
36,446 feet (11,108 m)
57,895 feet (17,645 m)
92,015 feet (28,045 m)
HKX4-1
18 AWG
16 AWG
14 AWG
2,711 feet
4,306 feet (1,312 m)
6,844 feet (2,086 m)
(826 m)
HKX4-2
18 AWG
16 AWG
14 AWG
108 feet
172 feet
274 feet
(33 m)
(52 m)
(83 m)
HKX4-3
230 VAC
120 VAC
24 VAC
18 AWG
16 AWG
14 AWG
9,111 feet (2,777 m)
14,474 feet (4,411 m)
23,004 feet (7,011 m)
HKX6-1
18 AWG
16 AWG
14 AWG
1,355 feet
2,153 feet
3,422 feet (1,043 m)
(413 m)
(656 m)
HKX6-2
18 AWG
16 AWG
14 AWG
54 feet
86 feet
137 feet
(17 m)
(26 m)
(42 m)
HKX6-3
230 VAC
120 VAC
24 VAC
18 AWG
16 AWG
14 AWG
4,556 feet (1,389 m)
7,237 feet (2,206 m)
11,502 feet (3,506 m)
HKX8/10-1
HKX8/10-2
HKX8/10-3
18 AWG
16 AWG
14 AWG
1,128 feet
1,791 feet
2,857 feet
(343 m)
(545 m)
(870 m)
18 AWG
16 AWG
14 AWG
112 feet
179 feet
285 feet
(34 m)
(54 m)
(86 m)
230 VAC
18 AWG
16 AWG
14 AWG
4,145 feet (1,263 m)
6,579 feet (2,005 m)
10,496 feet (3,199 m)
14
Pelco Manual C1495M-B (10/03)
OPERATION
Enclosure heaters turn on at 40°F (4°C) and turn off at 60°F (16°C).
Enclosure blower fans operate continuously.
SPECIFICATIONS
MAXIMUM CAMERA AND LENS SIZE
(With Heater Only)
1.75 in. H x 3.375 in. W x 10.375 in. L (4.45 x 8.57 x 26.35 cm)
EHX4E (only)
10.38 in. L x 3.0 in. diameter (26.36 x 7.62 cm)
(With Blower Only or Blower and Heater)
1.75 in. H x 3.375 in. W x 9 in. L (4.45 x 8.57 x 22.86 cm)
9 in. L x 3.0 in. diameter (22.86 x 7.62 cm)
EHX4E
EHX6E
3.75 in. H x 4.375 in. W x 22.25 in. L (9.53 x 11.11 x 56.52 cm)
22.25 in. L x 5.0 in. diameter (56.52 x 12.70 cm)
EHX6E-16
EHX8E
3.75 in. H x 4.375 in. W x 14.25 in. L (9.53 x 11.11 x 36.20 cm)
14.25 in. L x 5.0 in. diameter (36.20 x 12.70 cm)
5.75 in. H x 5.125 in. W x 22.25 in. L (14.60 x 13.02 x 56.52 cm)
22.25 in. L x 7.3 in. diameter (56.52 x 18.54 cm)
EHX10E
7.75 in. H x 5.75 in. W x 22.25 in. L (19.69 x 14.61 x 56.52 cm)
22.25 in. L x 9.0 in. diameter (56.52 x 22.90 cm)
(Design and product specifications subject to change without notice.)
Pelco Manual C1495M-B (10/03)
15
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual # Date
Comments
C1495M
9/98
7/99
Original version.
C1495M-A
Moved certifications to model description. Revised heater kit and blower kit installation instruction, wiring diagrams, exploded
assembly diagrams, and parts lists. Added specifications.
C1495M-B
10/03
Added solder lug to Figures 1 and 2 and Table A per ECO #03-8634.
®Pelco, the Pelco logo, Spectra, Genex, Coaxitron, Legacy, Esprit,
Camclosure, Spectra III, and Spectra III SE are registered trademarks of Pelco.
© Copyright 2003, Pelco.
All rights reserved.
16
Pelco Manual C1495M-B (10/03)
|