ICI3000P
Inter-Check Point-Of-Sale
Monitoring System
Installation/Operation Manual
C1043M-A (2/96)
PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827
6.0 HOT KEY SUMMARY LIST ............................................................................................................. 21
7.0 TROUBLESHOOTING .................................................................................................................... 23
8.0 POWER-UP PROCEDURE FOR THE ICI3000P ............................................................................ 24
9.0 SPECIFICATIONS ...........................................................................................................................25
9.1 OUTPUT DEFINITIONS ........................................................................................................ 26
9.2 DB9 PINOUT ......................................................................................................................... 26
10.0 WARRANTY AND RETURN INFORMATION.................................................................................. 27
LIST OF ILLUSTRATIONS
Figure
Page
1
2
3
4
5
6
7
8
TYPICAL ICI3000P SYSTEM USED WITH STAND-ALONE CAMERAS ..............................................2
ICI3000P PARTYLINE WIRING CONFIGURATION ..............................................................................4
DEFAULTING INTER-CHECK SYSTEM. ..............................................................................................5
CASCADING THE ICI30008 OR ICI3016..............................................................................................6
ALARM PIN-OUT CONFIGURATIONS .................................................................................................7
VIDEO ADJUSTMENT LOCATIONS .....................................................................................................8
INTER-CHECK'S TWO TEXT SCREENS .............................................................................................9
DB25 PRINTER CONNECTOR TO DB9 ICI3000P UNIT PIN ASSIGNMENTS.................................14
REVISION HISTORY
Manual #
Date
Comments
C1043M-A
2/96
Revised to incorporate new installation/operation information throughout.
Pelco Manual C1043M-A (2/96)
iii
(This page intentionally left blank.)
iv
Pelco Manual C1043M-A (2/96)
INSTALLATION/OPERATION MANUAL
ICI3000P INTER-CHECK® POINT-OF-
SALE MONITORING SYSTEM
1.0 WARNINGS
Priortoinstallationanduseofthisproduct,thefollowing
WARNINGS should be observed.
1. Installation and servicing should only be done by
qualified service personnel and conform to all
Local codes.
4. Only use replacement parts recommended by
PELCO.
5. After replacement/repair of this unit’s electrical
components, conduct a resistance measurement
betweenlineandexposedpartstoverifytheexposed
parts have not been connected to line circuitry.
2. Unless the unit is specifically marked as a NEMA
Type 3-6P enclosure, it is designed for indoor use
only and it must not be installed where exposed to
rain and moisture.
3. The product may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TOREDUCETHERISKOFELECTRICAL
SHOCK, DO NOT REMOVE COVER. NO
USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C1043M-A (2/96)
1
2.0 SCOPE
2.1 DESCRIPTION
The information contained within this manual covers
the installation and operation of the Inter-Check
ICI3000P cash register interface system. Installation
should be in accordance with all applicable local and
national electric codes, using approved materials only.
Please familiarize yourself with the information within
this manual prior to installation and operation.
These units are point-of-sale (POS) monitoring devices
capable of monitoring up to sixteen (16) POS termi-
nals simultaneously with up to thirty-two (32) units in-
stalled at one time. Standard features include: fifteen
programmable exceptions, two video inputs, one video
output and two alarm outputs. Increased video inputs
and alarm outputs may be obtained by interfacing with
an optional Inter-Check switcher.
Figure 1. Typical ICI3000P System with Fixed Cameras
2
Pelco Manual C1043M-A (2/96)
3.0 INSTALLATION
7. To verify communication between your
ICI1000PIM and the ICI3000P, press [I] on the
keyboard and the following will be displayed:
3.1 SETTING UP ICI1000PIM
PARAMETERS AND BENCH
TESTING
Poll initialized!
Reg. polled = 1 1 Reg. answer!
Reg. polled = 2 2 No reg. answer!
Reg. polled = 3 3 No reg. answer! etc.
NOTE: Please familiarize yourself with the
information in this manual prior to installation
and operation. Contact the customer's register
dealer/installer prior to installation and opera-
tion. Some warranties and/or service agree-
ments may be affected.
The display will poll for 32 ICI1000PIM addresses, and
then repeat display the addresses that answer.
8. Stop polling by pressing [P] again. The following
message will be displayed:
1. Set the ICI1000PIM switch settings for your reg-
ister according to the PIM manual (C1005M).
Make sure that switch number 2 on switch bank 1
is placed in the [-] "UP" or “POLLING” position.
Also, you must address each PIM individually;
refer to page #2 in your ICI1000PIM manual.
Poll watch off!
9. Select the Register PIM by pressing [F1] then [1]
followed by [Reg #] and [ENT].
10. Power down the ICI1000PIM. Power ICI1000PIM
up again.
2. Plug the data (phone-style) cable supplied with the
ICI3000WK between the ICI1000PIM set to ad-
dress #1 and the port labeled DATA IN on the
ICI3000P unit.
11. A prompt will appear on the bottom of the screen.
Verify that this prompt matches the description set
forth in the manual supplied with your interface
cable.
3. Connect a coaxial cable between the port labeled
“VIDEO OUT” of the ICI3000P and a CCTV
monitor.
12. Repeat these steps for the remainder of your
ICI1000PIM’s
4. Press the [1] one key on your keyboard while pow-
ering up the ICI3000P. The following will be dis-
played on your screen:
NOTE: Each ICI1000PIM must have a dif-
ferent Polling address. Refer to the ICI1000PIM
manual for proper settings.
!!DEFAULTS LOADED!!
ICI3000P BY PELCO, INC.VER. X.X
CRC = YYYY
13. After polling each ICI1000PIM, power down the
ICI3000P and begin installation of the ICI1000PIM
and cash register interface cable into each cash reg-
ister. Refer to the manual supplied with your inter-
face cable for proper installation.
CALCULATED CRC = ZZZZ
5. Power up the ICI1000PIM with the supplied trans-
former.
6. Press [P] on the keyboard and the following will
be displayed:
Poll watch on!
Pelco Manual C1043M-A (2/96)
3
3.2 ICI3000WK INSTALLATION
NOTE: Do not mount the Inter-Check unit
until all connections are made and program-
ming is complete. Video adjustments on the
underside of the unit may need to be accessible
during initial setup.
1. Install an 18AWG, 3-conductor shielded cable be-
tween each RJ14 phone jack at each cash register.
Refer to Figure 2 for appropriate wiring configu-
ration.
NOTE: Do not power up the ICI3000P unit
until all other connections have been made. Use
only the transformer supplied with your
ICI3000P unit. Other power supplies may cause
damage to the unit.
ICI3000P
1
2
3
4
5
6
7
8
ICI3000WK WIRE KIT
PHONE CABLE ("STRAIGHT THROUGH")
O
P
E
N
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
T
I
O
N
-
w
t
F
u
n
c
t
i
o
n
1
2
B
a
n
k
a
d
d
r
e
s
s
Bank Address
s
Bank Address
3
4
Bank Address
Bank Address
Loop Select
aud at
5
B
R
WHT
8
BLUE
NC
NC
N
O
TE:
C
o
ver
m
u
s
t
be
rem
t
o
ved
to
a
c
ce
ss
t
hi
s
dip
s
w
itch
.
*
L
o
o
p
=
0
C
A
2
M
E
R
A
S
1
6
-
3
1
A
d
d
r
e
s
s
=
0
0
0
1
BLK
YEL
2
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
1
V
I
D
E
O
I
N
P
U
T
S
L
o
o
p
=
1
C
A
M
E
1
R
A
S
1
-
1
9
5
A
d
d
r
e
s
s
=
0
0
0
0
RED
GRN
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
6
3
1
V
I
D
E
O
I
N
P
U
T
S
ICI1000PIM
DATA CABLE (same on
all jacks)
T
O
M
O
N
I
T
O
R
O
R
V
C
R
Shadow switchers are available in either
8
or 16 positions.
1
2
1
2
1
2
1
2
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
O
P
E
N
O
P
E
N
O
P
E
N
O
P
E
N
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
w
t
n
o
n
w
t
n
o
n
w
t
n
o
n
w
t
n
o
n
1
2
1
2
1
2
1
2
B
k
B
s
Bank Address
Bank Address
Bank Address
Bank Address
B
B
k
B
B
s
Bank Address
Bank Address
Bank Address
Bank Address
3
4
3
4
3
4
3
4
Bank Address
Bank Address
Bank Address
Bank Address
t
B
t
B
Bank Address
Loop Select
aud at
Bank Address
Loop Select
aud at
Bank Address
Loop Select
aud at
Bank Address
Loop Select
aud at
5
5
5
5
l
l
B
R
b
B
R
t
B
R
b
B
R
c
WHT
8
BLUE
WHT
8
BLUE
WHT
8
BLUE
WHT
8
BLUE
NC
NC
NC
NC
NC
NC
NC
NC
N
N
N
N
N
O
T
E
t
:
C
o
ver
m
u
s
t
be
rem
o
ved
to
a
c
c
t
hi
s
dip
s
w
itch
.
t
N
O
TE:
C
o
ver
m
u
s
t
be
rem
o
ved
to
a
c
ce
ss
t
t
hi
s
dip
s
w
itch
.
t
N
O
t
TE:
C
o
ver
m
u
s
t
be
rem
o
ved
to
a
c
ce
ss
t
hi
s
dip
s
w
itch
.
N
O
T
E:
C
o
ver
m
u
s
t
be
rem
t
o
ved
to
a
c
ce
ss
t
hi
s
dip
s
w
itch
.
*
L
o
o
p
=
0
L
o
o
p
=
0
L
o
o
p
=
0
L
o
o
p
=
0
C
A
2
M
E
R
A
S
1
6
-
3
1
C
A
2
M
E
R
A
S
1
6
-
3
1
C
A
2
M
E
R
A
S
1
6
-
3
1
C
A
2
M
E
R
A
S
1
6
-
3
1
A
d
d
r
e
s
s
=
0
0
0
1
A
d
d
r
e
s
s
=
0
0
0
1
A
d
d
r
e
s
s
=
0
0
0
1
A
d
d
r
e
s
s
=
0
0
0
1
BLK
YEL
BLK
YEL
BLK
YEL
BLK
YEL
2
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
1
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
L
o
o
p
=
1
L
o
o
p
=
1
L
o
o
p
=
1
L
o
o
p
=
1
C
A
M
E
1
R
A
S
1
-
1
9
5
C
A
M
E
1
R
A
S
1
-
1
9
5
C
A
M
E
1
R
A
S
1
-
1
9
5
C
A
M
E
1
R
A
S
1
-
1
9
5
A
d
d
r
e
s
s
=
A
d
d
r
e
s
s
=
A
d
d
r
e
s
s
=
A
d
d
r
e
s
s
=
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RED
GRN
RED
GRN
RED
GRN
RED
GRN
2
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
8
7
6
5
4
3
1
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
T
O
M
O
N
I
T
O
R
O
R
V
C
R
T
O
M
O
N
I
T
O
R
O
R
V
C
R
T
O
M
O
N
I
T
O
R
O
R
V
C
R
T
O
M
O
N
I
T
O
R
O
R
V
C
R
Shadow switchers are available in either
8
or 16 positions.
Shadow switchers are available in either
8
or 16 positions.
Shadow switchers are available in either
8
or 16 positions.
Shadow switchers are available in either
8
or 16 positions.
1
2
1
2
1
2
1
2
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
O
P
E
N
O
P
E
N
O
P
E
N
O
P
E
N
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
-
D
S
I
P
i
S
c
WI
h
T
#
C
H
D
E
S
C
R
I
P
F
T
u
I
O
c
N
t
-
i
w
t
n
o
n
w
t
n
o
n
w
t
n
o
n
w
t
n
o
n
1
2
1
2
1
2
1
2
B
a
n
k
a
d
d
r
e
s
s
B
a
n
k
a
d
d
r
e
s
s
B
a
n
k
a
d
d
r
e
s
s
B
a
n
k
a
d
d
e
s
s
Bank Address
Bank Address
Bank Address
Bank Address
B
B
k
B
B
s
s
Bank Address
Bank Address
Bank Address
Bank Address
3
4
3
4
3
4
3
4
k
Bank Address
Bank Address
Bank Address
Bank Address
t
B
k
t
B
s
Bank Address
Loop Select
aud at
Bank Address
Loop Select
aud at
Bank Address
Loop Select
aud at
Bank Address
Loop Select
aud at
5
5
5
5
s
l
l
B
R
b
B
R
t
B
R
b
B
R
c
WHT
8
BLUE
WHT
8
BLUE
WHT
8
BLUE
WHT
8
BLUE
NC
NC
NC
NC
NC
NC
NC
NC
N
N
N
N
N
O
T
E
t
:
C
o
ver
m
u
s
t
be
rem
o
ved
to
a
c
c
t
hi
s
dip
s
w
itch
.
t
N
O
TE:
C
o
ver
m
u
s
t
be
rem
o
ved
to
a
c
ce
ss
t
t
hi
s
dip
s
w
itch
.
t
N
O
t
TE:
C
o
ver
m
u
s
t
be
rem
o
ved
to
a
c
ce
ss
t
hi
s
dip
s
w
itch
.
N
O
T
E:
C
o
ver
m
u
s
t
be
rem
t
o
ved
to
a
c
ce
ss
t
hi
s
dip
s
w
itch
.
*
L
o
o
p
=
0
L
o
o
p
=
0
L
o
o
p
=
0
L
o
o
p
=
0
C
A
2
M
E
R
A
S
1
6
-
3
1
C
A
2
M
E
R
A
S
1
6
-
3
1
C
A
2
M
E
R
A
S
1
6
-
3
1
C
A
2
M
E
R
A
S
1
6
-
3
1
A
d
d
r
e
s
s
=
0
0
0
1
A
d
d
r
e
s
s
=
0
0
0
1
A
d
d
r
e
s
s
=
0
0
0
1
A
d
d
r
e
s
s
=
0
0
0
1
BLK
YEL
BLK
YEL
BLK
YEL
BLK
YEL
2
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
1
1
1
0
9
8
7
6
5
4
3
1
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
L
o
o
p
=
1
L
o
o
p
=
1
L
o
o
p
=
1
L
o
o
p
=
1
C
A
M
E
1
R
A
S
1
-
1
9
5
C
A
M
E
1
R
A
S
1
-
1
9
5
C
A
M
E
1
R
A
S
1
-
1
9
5
C
A
M
E
1
R
A
S
1
-
1
9
5
A
d
d
r
e
s
s
=
A
d
d
r
e
s
s
=
A
d
d
r
e
s
s
=
A
d
d
r
e
s
s
=
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RED
GRN
RED
GRN
RED
GRN
RED
GRN
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
8
5
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
8
6
3
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
7
5
4
2
1
V
I
D
E
O
O
U
T
1
6
1
5
1
4
1
3
1
2
1
1
0
6
3
1
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
V
I
D
E
O
I
N
P
U
T
S
T
O
M
O
N
I
T
O
R
O
R
V
C
R
T
O
M
O
N
I
T
O
R
O
R
V
C
R
T
O
M
O
N
I
T
O
R
O
R
V
C
R
T
O
M
O
N
I
T
O
R
O
R
V
C
R
Shadow switchers are available in either
8
or 16 positions.
Shadow switchers are available in either
8
or 16 positions.
Shadow switchers are available in either
8
or 16 positions.
Shadow switchers are available in either
8
or 16 positions.
NOTES:
• Use 18 AWG 3-conductor Shielded wire for all loop interconnections.
• Data wire distance must not exceed 1500 feet.
• DO NOT Connect the Shield on the ICI3000P end of the loop.
Figure 2. ICI3000P Partyline Wiring Configuration
4
Pelco Manual C1043M-A (2/96)
3.3 ICI3008/ICI3016 INSTALLATION
0000 1000 where 0 = ON and 1 = OFF (refer to
Figure 8).
Refer to Figure 1 for a typical ICI3000P configuration.
6. Connect the desired alarm outputs to any peripheral
equipment requiring a normally open contact. (Refer
to Figure 5 for pin assignment information.)
1. Connect the 9-pin switcher interface cable (supplied
with the ICI3008/ICI3016 switcher) into the port
labeled “RS 232” of the ICI3000P.
7. Connect an “IBMAT” compatible keyboard into the
ICI3000P input labeled “KEYBOARD”.
2. Connect the modular phone plug of the switcher
interface cable into the port labeled “DATA IN” on
the ICI3008/ICI3016 switcher.
8. Power up the Inter-Check units using the transformers
supplied with each unit.
3. Connect the video output from your cameras to the
BNC’s labeled “VIDEO INPUTS” on the ICI3008/
ICI3016.
9. To verify communication between the Inter-Check
switcher and the ICI3000P, press [F9]. Press [F9]
again. Next, select camera one by entering a [1] one
followed by the [ENTER] key. The first red light
labeled “1” on the first switcher should be on. Repeat
this step for each camera input on each switcher. If
an 8 or 16-position switcher has a second switcher
cascaded from it, selecting camera 8 or 16
respectively will cause the first light of the second
switcher to be activated.
4. Connect a coaxial cable between the port labeled
“VIDEO OUT” of the ICI3008/ICI3016 and the port
labeled “VIDEO IN” of the ICI3000P.
5. If multiple ICI3008/ICI3016 switchers are being cas-
caded, connect a coaxial cable from the last video
input of the first Inter-Check switcher to the port
labeled “VIDEO OUT” of the second Inter-Check
switcher. Remove the cover of the second Inter-
Check switcher and set the 8 position dip switch to
0001 0000. Remove the cover of the first Inter-
Check switcher and set the 8-position dip switch to
ICI3000P by PELCO
Ver. 4.0
!!!Defaults Loaded!!!
ROM Check = xxxx
Calc.ROM Check = yyyy
System Being Initialized
SYSTEMBEING INITIALIZED
MM Ver.z.z
P E L C O
P E L C O
Text on screen will flash
Press the [1] key on thekeyboardfor
if defaults were loaded.
approximately 3 seconds.
Figure 3. Defaulting Inter-Check System
Pelco Manual C1043M-A (2/96)
5
1
2
3 4 5 67
8
OPEN
- D I
P
S WI T C H D E S C R I P T I O N -
S w i
t
c h
#
F u n c t
i
o n
1
2
3
4
a d d e s
Bank Address
Bank Address
Bank Address
Bank Address
5
6
7
8
Loop Select
Baud Rate Select
e
NC
NC
N
O
T
E
: C
o
ver
m
u
s
t
berem
o
vedto
a
c
c
t
hi
s
dip
s
w
itch
.
L o o p
A d d r e s s
=
0
C A ME R A S 1 6 - 3 1
=
0 0 0 1
V I D E O O U T
1 6
1
5
1 4
1 3
1 2
1 1
1
0
9
8
7
6
5
4
3
2
1
V I D E O
I
N P U T S
L o o p
A d d r e s s
=
1
C A ME R A S 1 - 1 5
=
0 0 0 0
V I D E O O U T
1 6
1
5
1 4
1 3
1 2
1 1
1
0
9
8
7
6
5
4
3
2
1
V I D E O
I
N P U T S
T O MO N I T O R O R V C R
Shadow switchers are available in either 8 or 16 positions.
Figure 4. Cascading the ICI30008 or ICI3016
6
Pelco Manual C1043M-A (2/96)
3.3.1 Alarm Pin-out Configuration
For detailed 25-pin and 9-pin alarm pin-out configura-
tion information, see Figure 5 below.
25-PIN CONNECTOR FOR ICI3016
9-PIN CONNECTOR FOR ICI3008
5
4
3
2
1
1
13
9
8
7
6
25
14
Pin #
Alarm Output
Pin #
Alarm Output
1
2
3
4
5
6
7
8
Alarm Output 1
Alarm Output 2
Alarm Output 3
Alarm Output 4
Alarm Output 5
Alarm Output 6
Alarm Output 7
Alarm Output 8
Alarm Output 9
Alarm Output 10
Alarm Output 11
Alarm Output 12
Alarm Output 13
Alarm Output 14
Alarm Output 15
Alarm Output 16
1
2
3
4
5
6
7
8
9
Alarm Output 5
Alarm Output 7
Alarm Output 6
Alarm Output 8
Alarm Output 1
Alarm Output 3
Alarm Output 2
Alarm Output 4
9
Common Ground
10
11
12
13
14
15
16
17-25 Common Ground
Figure 5. Alarm Pin-Out Configurations
Pelco Manual C1043M-A (2/96)
7
3.4 EXTERNAL VIDEO ADJUSTMENTS
5. Adjust the video GAIN of the monitor by adjusting
the potentiometer labeled “G”. This should be turned
all the way down for normal application.
There are five potentiometer adjustments located on the
bottom of the Inter-Check unit. These video text ad-
justments are for fine tuning only. Major adjustments
should be done through the operating software. Use a
small tipped, nonmetallic screwdriver for adjusting the
potentiometers on the bottom of the Inter-Check unit
(see Figure 6).
6. Use the two DIP switches labeled "C" to adjust the
size of the characters.
7. To keep the programming from being changed or
lost, move the switch labeled “NV” into the locked
position. This will prevent the loss of programmed
settings in the case of power loss or battery failure.
1. Adjust the HORIZONTAL SIZE of the text on your
monitor by rotating the potentiometer labeled “S”.
2. Adjust the INTENSITY of the text on your monitor
by rotating the potentiometer labeled “I”.
3. Adjust the HORIZONTAL POSITIONING of the
text on your monitor by rotating the potentiometer
labeled “H”.
4. Adjust the VERTICAL POSITIONING of the text
on your monitor by rotating the potentiometer labeled
“V”. If rotated fully counterclockwise the display
may “jitter”. A slight clockwise adjustment will
correct this problem.
S
G
NV Memory
Switch
Unlocked
Locked
H
I
V
C
Figure 6. Video Adjustment Locations
8
Pelco Manual C1043M-A (2/96)
4.0 PROGRAMMING
4.1 REGISTER 1 OR 2 SELECT
To enter the SELECT MENU press enter. The following
menu will be displayed on monitor:
This menu allows you to manually display the transaction
data from a specific register on either Screen 1 (the left-
hand side of the monitor) or Screen 2 (the right-hand side
of the monitor). (See Figure 7.) To enter this menu, press
[1]. The monitor will display: Screen 1 or 2?
SELECT MENU
Select the screen (1 or 2) on which you want your register
data to be displayed and then press [Enter].
The next prompt is: Enter Register #_
1. Register # 1 or 2
2. Operator # 1 or 2
3. Exceptions on/off
4. Camera select
5. Screen print on/off
6. Auto camera search on/off
7. Reverse video on/off
8. System program
9. Exceptions program
0. Syssave/Sysread
Type in the Register number to be monitored. Press
[Enter]. Pressing [Enter] without selecting a Register
will turn off the previously selected screen. For ICI3000P
installations, register numbers correspond to the address
of the ICI1000PIM installed within the register.
4.1.1 Register Selection Using the
Hot Key F1
To select a specific Register for monitoring while in the
monitoring mode:
1. Press [F1]
2. Select appropriate Screen # (no prompt is displayed):
Pressing [1] = Screen 1, Pressing [2] = Screen 2
3. Select Register # or PIM NUMBER for monitoring.
4. Press [ENTER].
4.2 OPERATOR # 1 OR 2
This menu allows you to manually display the transaction
data from a specific operator on either Screen 1 (the left-
hand side of the monitor) or Screen 2 (the right-hand side
of the monitor). To enter this menu, press [2]. The monitor
will display: Screen 1 or 2?
S C R E E N # 1
O R
S C R E E N # 2
O R
Select the screen (1 or 2) on which you want your register
data to be displayed.
T E X T WI N D O W
# 1
T E X T WI N D O W
# 2
The next prompt is: Enter operator # OPR ??
Type in the operator number to be monitored (up to three
digits). Press [Enter]. Pressing [Enter] without
selecting an Operator will turn off the previously selected
screen.
P E L C O
Figure 7. Inter-Check’s Two Text Screens
Pelco Manual C1043M-A (2/96)
9
4.2.1 Operator Selection Using
the Hot Key F2
• Press [3] to select internal synchronization (no
video).
To select a specific operator for monitoring while in the
monitoring mode:
• Pressing F9 will enable you to select an external
camera from PELCO’s ICI3008/ICI3016 Inter-
Check switchers.
1. Press [F2]
After pressing F9, the following prompt will be displayed:
Enter select #
2. Select appropriate Screen # (no prompt is displayed):
Pressing [1] selects Screen 1
Pressing [2] selects Screen 2
Select camera number that corresponds to the
ICI3008/ICI3016 switcher.
3. Select operator number for monitoring.
4. Press [ENTER].
4.4.1 Camera Select Using Hot
Key F9
4.3 EXCEPTIONS ON/OFF
From the monitoring mode:
This function tells the Inter-Check unit whether or not
you want it to search for specific transactions that may
indicate fraudulent activity, known as “Exceptions”.
This works as a toggle switch.
1. Press [F9]
2. Select appropriate Video Input mode
1 = Video Input 1
2 = Video Input 2
3 = Internal Sync
• Press the [3] key to turn on the Exceptions. The
prompt, Exceptions on! will be displayed at the
top of the monitor.
F9 = Shadow List line item (To select an external
camera from ICI3008/ICI3016 Inter-Check switch-
ers.)
• Pressing the [3] key again will turn off the Excep-
tions. The prompt, Exceptions off! will be dis-
played at the top of the monitor.
4.5 SCREEN PRINT ON/OFF
This selection enables auxiliary serial printer port 1 on
the ICI3000P. To access this menu, press [5]. The fol-
lowing prompt will be displayed:
4.3.1 Exceptions On/Off Using the Hot
Key F3
Screen 1 or 2?
To toggle the Exceptions on/off from the monitoring
mode, press [F3].
Enter the screen number you wish to print.
4.4 CAMERA SELECT
4.5.1 Screen Print On/Off Using
Hot Key F4
This function is used to select a video input from the
ports labeled “VIDEO IN” on the ICI3000P, a selected
input from the ICI3008/ICI3016 camera list or no video
which is defined as internal sync.
From the monitoring mode:
1. Press [F4]
2. Select screen number to be printed
[1] = Screen 1
To access this menu, press [4]. The following prompt
will be displayed: Camera 1, 2, 3 internal, F9 exter-
nal
[2] = Screen 2
• Press [1] to select “VIDEO IN 1” on the back of the
ICI3000P.
• Press [2] to select “VIDEO IN 2” on the back of the
ICI3000P.
10
Pelco Manual C1043M-A (2/96)
4.6 AUTO CAMERA SEARCH ON/OFF
4.8 SYSTEM PROGRAM
When enabled, this feature monitors your camera
system’s sync generation. If your monitoring camera
loses power or is disconnected, the system will auto-
matically switch to the next camera for synchroniza-
tion. If an active video is not detected, the system will
automatically switch to “internal sync”. To enable the
Auto Camera Search feature, press [6]. Press [6] again
to turn off this feature.
This menu is used for programming text displays;
communication and printer parameters; clock features;
camera selections and alarm dwell time.
To enter the System Menu, Press [8]. The following
menu will be displayed:
SYSTEM MENU
4.6.1 Auto Camera Search On/Off
Using Hot Key F12
1. # Chars./line
2. # Lines for small scrn 1 or 2
3. Small scrn position 1 or 2
4. Large scrn position 1 or 2
5. Alarm dwell time
6. Channel parms
7. Printer parms
From the monitoring mode:
• Press [F12] to activate Auto Camera Search.
• Press [F12] again to deactivateAuto Camera Search.
4.7 REVERSE VIDEO ON/OFF
8. Set clock
This feature changes the visual characteristics of the data
displayed by placing a black background around the video
characters.
9. Ext. cam. select
0. Shadow List
• To enable the Reverse Video, press [7].
• To disable this feature press [7] again.
4.7.1 Reverse Video On/Off Using
Hot Key F10
4.8.1 Number of Characters Per Line
From the monitoring mode:
1. Press [F10] to activate Reverse Video.
2. Press [F10] again to deactivate reverse video.
Selecting 1 from the SYSTEM MENU enables you to
select the number of characters per line displayed on the
monitor.
Enter a number from 1-80best suiting your application.
To access this menu, press [1]. The following prompt
will be displayed: Screen 1 or 2?
Enter the Screen number you wish to adjust. The following
prompt will be displayed:
# of characters = 40
Enter # of characters/line 1-80
• Enter the number of characters to be displayed.
• Press ENTER.
NOTE:The ICI3000P can only display 80 total
characters per line. Selecting 50 characters for
Screen 1 only allows 30 characters to be
displayed on Screen 2.
Pelco Manual C1043M-A (2/96)
11
4.8.2 Number of Lines for Small
Screens 1 and 2
Using the cursor control keys, move the block to the
desired position on the monitor. Press [ENTER] to save.
This feature enables you to select the number of data lines
displayed on each screen. The difference between the
“small” and “large” screens is that you may reduce the
number of lines displayed on the small screen, while the
large screen always displays 17 lines of text.
NOTE: Overlapping the two screens will result
in “clipping” of the displayed text.
4.8.4 Large Screen Position 1 or 2
This feature enables you to position the text display of
your Large Screen option. This works the same way as
the previous small screen position function, except that
17 lines of data will always be displayed.
• To access this menu, press [2]. The following prompt
will be displayed: Screen 1 or 2?
• Enter the applicable screen, then press [Enter]. The
following prompt will be displayed:
4.8.4.1 Large and Small Screen
Toggle Using Hot Key F7
# of lines = 5 Enter # of lines 1-17
• Enter the number of lines desired. Press [ENTER].
• To toggle between Large and Small screen options,
press [F7] from the monitoring mode.
4.8.3 Small Screen Position 1 or 2
4.8.5 Alarm Dwell Time
This feature enables you to position the displayed text on
the monitor. To access this menu, press [3]. The following
prompt will be displayed: Screen 1 or 2?
This feature is used to set the amount of time the alarming
output stays activated after an alarm condition. To edit
this feature press [5]. The following prompt will be
displayed:
Enter the screen number you wish to edit. The following
numbers will be displayed:
Screen 1 or 2?
(Screen 1)
• Screen 1 is linked to the #1 Alarm Output.
• Screen 2 is linked to the #2 Alarm Output.
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
• Enter the applicable screen number. The following
prompt will appear: Alarm dwell = 1
(Screen 2)
• Enter an alarm dwell time 0-255
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
The default dwell time is set to 1 second. To change the
dwell time, enter the new dwell time in seconds. Press
[ENTER].
NOTE: Only one of these blocks will appear
at one time.
This block represents the text normally displayed on the
monitor. The number of characters and lines displayed in
this block will correspond to the selections made in
Section 4.8.1 and 4.8.2. It also represents the current text
position on the monitor.
12
Pelco Manual C1043M-A (2/96)
4.8.6 Channel Program Menu
4.8.6.1 Partyline
Exception Follow Alarm Time
This option is used to set the length of time the
Inter-Check unit will dwell on an exception when
using the Exception Follow or Hot Key E. When
this option is selected, the video screen will dis-
play:
Press [6]. The following prompt will be displayed:
CHANNEL PROGRAM MENU
4. Group Poll List
5. Exception Follow AlarmTime
6. Group Select
Alarm Dwell = 10
Enter Alarm Dwell Time 0 - 255
4.8.6.2 Channel Program Menu
Group Select
This option is used to choose a group of eight reg-
isters in the poll list that you want to edit using the
Group Poll List menu option.
1. Baud Rate — Not Applicable
2. RS-232 — Not Applicable
3. ISO-Jack — Not Applicable
Group Poll List
This selection will allow you to edit the eight-
register group you choose using Group Select in
the Channel Program group. This selection is used
if there are more than 16 registers in the system.
This list allows you to monitor any combination
of 16 registers.
For example, if you wish to monitor registers 1
through 8 plus registers 18 through 26, you would
select Group 2 using the Group Select menu op-
tion. Then select the Group Poll List menu option
and enter registers 18 through 26 to be monitored
in Group 2 rather than the default list which is 9
through 16.
The 16 registers to be monitored can also be se-
lected using Hot Key G and Hot Key B while in
the monitoring mode.
Hot Key G is used to select one of the four groups
of eight registers. The status bar at the bottom of
the video screen will show which screen is cur-
rently selected. If Group 2 is selected, for example,
the status bar will read:
G4 = 2.
Similarly, if you wish to select a block of registers
(16 registers), press Hot Key B. If Block 2 is se-
lected, for example, the status bar will read: B2 =
2. (Block 2 includes registers 17 through 32, which
is the same as Groups 3 and 4.)
Pelco Manual C1043M-A (2/96)
13
4.8.7 Printer Parameters
4.8.9 External Camera Select
From this menu the baud rate for the auxiliary output port
may be adjusted to communicate with an optional serial
printer. The Inter-Checkdefaults to 9600 baud.
This feature selects the screen (1 or 2) to be used for
controlling the Inter-Check switcher. The selected screen
will have an “S” displayed at the bottom.
To edit the baud rate, press [7]. The following prompt
will appear:
• To change the settings, press [9]. The monitor will
display: Screen 1 or 2?”
Printer baud = 9600
Enter baud rate 1 - 19200?
• Select the desired screen. The following prompt will
appear: 1. on 2. off
Enter the desired baud rate for your printer.
Press [ENTER].
• Press [1] for screen on or [2] for screen off.
4.8.8 SET CLOCK
4.8.9.1 Equivalent Camera Select
Hot Key F9
This function is used to set the internal clock to match
real time. To edit, press [8]. The following prompt will
be displayed:
1.Time
1. Press [F9]
2. Select appropriate Video Input mode
1 = Video Input 1
2. Date
2 = Video Input 2
3 = Internal Sync
• To set the time, press [1].
• Enter the correct military time separating each pair
of numbers by a colon.
OR - For manual external camera selection on an Inter-
Check Switcher:
• Press [ENTER] to save.
1. Press [F9]
• To set the date, press [2].
• Enter the correct date separated by a slash.
• Press [ENTER] to save.
2. Press [F9] again
3. Select appropriate camera from the Shadow List:
[1] = Selects the camera programmed into Shadow
List preshot #1
[2] = Selects the camera programmed into Shadow
List preshot #2, etc.
D B 9
C O N N E C T O R
T O
CI3000
U N I
D B 2 5
C O N N E C T O R
I
P
P R I N T E R
T
1 3 1 2 1 1 1 0
9
8
7
6
5
4
3
2
1
5
4
3
2
1
2 5 2 4 2 3 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4
9
8
7
6
D B 9
-
B A C K V I E W
D B 2 5
-
B A C K V I E W
P I N 3
P I N 7
=
=
R E C E I V E
G R O U N D
(
R x )
P I N 3
P I N 5
=
=
T R A N S M I
G R O U N D
T
(
(
T x )
(
G n d )
G n d )
Figure 8. DB25 Printer Connector to DB9 ICI3000P Unit Pin Assignments
14
Pelco Manual C1043M-A (2/96)
4.8.10 Shadow List Programming
Example 1:
Shadow List
This list tells the 8- or 16-position Inter-Check Switcher
which camera and POS terminal are linked together. It is
also used to program sequential video switching. The [S]
hotkey is used to turn switcher sequencing on and off.
REG CAM DWL
1.
2.
3.
4.
5.
1
2
3
4
5
1
1
2
6
9
5
6
4
2
Press [0].A long list of numbers will scroll up the screen.
The following prompt will appear:
30. 30
31. 31
32. 32
30
31
32
During sequencing, with the above parameters set, the
following would occur:
ESC to exit or ENTER to edit!
1. Camera 1 would be selected for 5 seconds.
2. Camera 1 would be selected for 6 more seconds.
3. Camera 2 would be selected for 4 seconds.
4. Camera 6 would be selected for 2 seconds.
5. Since there is no dwell time programmed for camera
9, it will be skipped and sequencing will start over
from the beginning.
The default setting is thirty-two line items. If you have
already changed the programming, the list will stop with
the last programmed item.
• Press [Enter] to edit. The cursor should now be
under the REG” (for Register) column.
Example 2:
• Type in the number of your first Register, then press
Shadow List
[Enter].
REG CAM DWL
1.
2.
3.
4.
1
2
3
4
1
2
3
4
REG
1.1
CAM DWL
1
5
5
5
The cursor will move to the next column under CAM.
Enter the camera number on the Inter-Check switcher used
to capture video for your first register. Press [Enter].
Number one has nothing programmed under dwell time.
The Inter-Check unit interprets this as “we’re at the end
of the sequence; go back to the beginning”. Since this
is the beginning, no sequencing takes place.
REG
1.1
CAM DWL
1
1
Each alarming output has its own dwell time. Alarm
output number two's dwell time is used for additional
functions, including switcher sequencing and excep-
tion hold time. If there are a number of conflicting com-
mands asking for the “use” of the timer simultaneously,
the timer determines priorities in the following order:
The cursor should now appear under the DWL column.
This is used for setting camera dwell time. Dwell time is
the amount of time in seconds that the video picture will
appear on the screen before switching to the next camera.
Enter the desired dwell time, then press [ENTER]. If
you want to skip a particular camera position during
sequencing, enter a zero for the camera dwell time.
1. Alarm output timing
2. Exception hold (if exceptions are on)
3. Shadow switcher (if sequencing is on)
NOTE: If you need to skip a line during
programming, press the [ESC] key. Pressing
the [ENTER] key will end your programming
session and return you to the System Menu.
During an exception, the camera dwell time pro-
grammed above will also be used for the dwell time of
the alarm output. The preprogramming dwell time for
the alarm output is overridden during an exception.
Once the exception alarm has “timed out”, sequencing
will continue from that item in the shadow list.
Pelco Manual C1043M-A (2/96)
15
4.9 EXCEPTIONS
Exceptions are cash register transactions of special interest
that can be programmed into the ICI3000P units. Typical
transactions areVOID, REFUND, CASH PAID OUT and
NO SALE. These types of transactions can then be used
to alarm your VCR or other alarmable device for video
recording. Exceptions can also be printed out on an
external serial printer for immediate hard-copy evidence.
NOTE: Exceptions can only be displayed on
screen #2. Therefore, you cannot monitor a
register or operator number on screen 2 if
exceptions are used.
Press [9]. In the Main Menu and the following menu will
be displayed:
EXCEPTIONS MENU
1. Edit exception text
2.TransactionType
3. Del. Register Mask
4. Apply Register Mask
Press [1]. The following prompt will be displayed:
Enter text or (ESC) to exit, (DEL) to delete line,
(ENTER) to end line
1234567890123456789012345678901234567890
01==_
The “1234...” sequence of numbers serves as your guide.
As mentioned earlier these numbers are called an
Exception Column Line.
16
Pelco Manual C1043M-A (2/96)
4.9.1 Exceptions using the
Column Specific Strategy
The example below will search data for any text in the
sixth position starting with D (Wildcard) SK.
Therefore, an exception will appear if the word DESK,
DISK, DUSK, or any other similar combination,
appears on the register.
A Column Specific Exception is used to “flag” a
transaction according specific placement of text on the
register ticket. As an example, if the word VOID
normally appears starting 5 spaces from the left during
a void transaction, you would type in the following:
1234567890123456789012345678901234567890
01=>^^^^VOID
1234567890123456789012345678901234567890
01=>^^^^D^SK
To accept this Column Specific caret situation press
[ENTER] at the end of the exception to save and
[ESC] to exit the Edit Exception Text menu.
A. To find specific text placement on the screen, select
a register by selecting the [F1] key in the
monitoring mode and then press the [register
number], and then [Enter].
4.9.2 Exceptions using the
Global Exception Strategy
A Global Exception is used to “flag” any text regardless
of the placement on the register receipt. Programming
is done by simply typing in the Exception you’re
interested in on the first line. An example of a VOID
Global Exception is shown below:
B. Turn on the exception column line by pressing the
[L] toggle key. The screen will now display:
1234567890123456789012345678901234567890
C. When you see the transaction come up on the
monitor’s screen, press the FREEZE toggle key
[F6]. This will stop the text from scrolling and
allow you to take a good, close look at the correct
placement of your particular transaction.
1234567890123456789012345678901234567890
01=>VOID
When you’re done, press [Enter] and the cursor will
jump down to the next line (02). At this point you can
either program in another Exception or press [ESC]
to exit. Up to 15 total Exceptions can be programmed
into your ICI3000P unit.
D. Write what you see on a piece of paper for a
programming reference. (You will need this
information when programming the information
you see now into the ICI3000P unit.) Use the
numbers above the text as a placement reference.
Use the [<Shift>] and [6] keys simultaneously to
produce the ^ (Caret) symbol (also used for wildcard
searches).
NOTE: When the caret symbol is used as
the first character of exception text, it causes
that line to become Column Specific. Also,
when the Caret is preceded by any other
character it will be recognized by Inter-Check
as a wildcard character. This means Inter-
Check will accept any character of text at that
point. Only ^ symbols used before your
Exception data will be recognized as column
dependent searches.
Pelco Manual C1043M-A (2/96)
17
4.9.3 Exceptions Using the Price
Point Editing Strategy
Place a Caret symbol in front of your text to make it
Column-specific, and between text as a wildcard
symbol.
This type of exception is used to program an exception
that is looking for characteristics in the actual price of the
item, rather than a specific word. The keyboard character
used in this type of exception strategy is a double bar [ ]
and is displayed by pressing [<SHIFT>] [\]
simultaneously.
1234567890123456789012345678901234567890
03=>^^^^^Total:^^^^^^^0000.00
If you want your ICI3000P to look for numbers that are
greater than, less than, or equal to a set limit (i.e., any
total less than 0 or any transaction greater than $999),
follow the last double bar with a “Greater Than”, “Less
Than” or “Equal To” symbol. For example, if we want
Inter-Check to look for any total of $999 or greater, we
would program the following:
Follow these procedures for successful programming:
1. First determine the maximum number of digits that
your register system allows, and figure out where on
the exception column line scale the price’s decimal
point will be lined up. A good way to figure this
position out is to use the exception column line
feature in the monitoring mode. This is done by
pressing the [L] key in the monitoring mode while
ringing in the desired transaction on the register you
are currently monitoring.
1234567890123456789012345678901234567890
03=>^^^^^Total:^^^^^^^0999.00 >
If you wanted Inter-Check to look for any negative total,
we would program the following:
1234567890123456789012345678901234567890
03=>^^^^^Total:^^^^^^^0000.00<
In this case, we are telling the ICI3000P to look for any
number “less than” 0000.00.
1A. Select a register by selecting the [F1] key in the
monitoring mode, then press the [register number],
and then [Enter].
If you wanted Inter-Check to look for any total equal to
$999.00 program the following:
1234567890123456789012345678901234567890
03=>^^^^^Total:^^^^^^^0999.00
1B. Turn on the exception column line by pressing the
[L] toggle key. The screen will now display:
1234567890123456789012345678901234567890
1C. When you see the transaction come up on the
monitor’s screen, press the FREEZE toggle key [F6].
This will stop the text from scrolling and allow you
to take a good, close look at the correct placement of
your particular transaction.
OR
1234567890123456789012345678901234567890
03=>^^^^^Total:^^^^^^^0999.00=
1234567890123456789012345678901234567890
03=>Total: 9999.99 ^
Equal is the default value so you don’t have to actually
insert the [=] sign after the double bar character. If you
decide to use the equal sign to be consistent, it will not
affect the operation of the Inter-Check unit.
(Decimal point at Second “2” position.
1D. Write what you see on a piece of paper for a
programming reference. (You will need this
information when programming the information you
see now into the ICI3000P unit.) Using the numbers
above the text as a placement reference.
NOTE: If you want to look for a total that is
less than another negative total (in other words,
more negative), use the negative total and the
less than sign.
In this example, we are looking for any total which shows
a refund greater than $2.00:
1E. Enter the Edit Exception Text Menu once again.
1234567890123456789012345678901234567890
03=>^^^^^Total:^^^^^^-0002.00< ^^
2. Next, type in [0’s] for every digit allowed by your
Register system, preceding the first “0” with a double
bar (|) and following the last “0” with a double bar.
“Negative”
“Less Than”
18
Pelco Manual C1043M-A (2/96)
4.9.4 Exceptions with
Descriptors
5.0 SUMMARY OF EXCEPTION
KEYBOARD DEFINITIONS:
If you would like to describe the type of Exception that is
being “flagged”, you can use a descriptor.As an example,
with our negative total, you may want Inter-Check to print
the following: “NEGATIVE TOTAL” following the
transaction. This is done by simply typing the
“Backslash” [\] key and the descriptor you want at the
end of the exception line (the last line of text or <, >,
or = sign).
[ENTER] Saves any changes to one line of text in
the exception text editor.
[DEL]
Deletes all characters to right of the cursor.
[ESC]
Exits out of the edit exception text menu
back into the exceptions main menu.
Example 1:
[^]
[\]
Wildcard or column specific character.
Descriptor symbol
1234567890123456789012345678901234567890123
03=>^^^^^Total:^^^^^^^0000.00<\NEGATIVE
TOTAL
[|]
Price point exception indicator
In this example using the column specific and price
point exception strategies, Inter-Check will print
“NEGATIVE TOTAL” as a descriptor after every
transaction that is less than $0.00.
[SPACE] Inserts position spaces in the editing mode.
[=]
Equal to a desired numerical value in price
point exceptions.
Please note that when programming descriptors or extra
text lines, this order/priority must be followed:
[>]
Greater than a desired numerical value in
price point exceptions.
First:
The exception price point or text and
its “definitions” such as (0000.00<)
or (VOID)
[<]
Less than a desired numerical value in
price point exceptions.
[TAB]
Has same function as the right arrow-
control key. Enables you to sequence
through each character on an exception
line which saves you the hassle of
reentering existing information on an
exception line.
Second:
Any descriptors such as
(0000.00<\NEGATIVE TOTAL)
It’s important to recognize how your ICI3000P reads
certain parts of your exception line when you program
that information. The "|" character is recognized as
taking up one space on the exception text line. The ^,
<, >, or = characters are not. Any text entered after
these signs will be recognized by your Inter-Check unit,
when scanning for exceptions that are met, as being in
the position they occupy. Here’s an example:
[~]
Tilde, used in conjunction with a + or -at
the end of an exception text causes the
display to print the 2 lines prior (-) or the
2 lines after (+) the exception.
1234567890123456789012345678901234567890
01=>^^^^^0000.00<N
You might say, at first glance, that Inter-Check will need
to see the letter “N” in the 15th position to recognize
this as an exception. In truth, the ICI3000P ignores the
position of the <sign, and “slides” the N over one space
to the 14th position. Please keep this in mind when
programming exception text that follows a price point.
Pelco Manual C1043M-A (2/96)
19
5.1 REGISTER MASKING
Do this for as many of your exceptions as you’d like. If
you had an exception you wanted to unlink or when
you are finished programming press [Enter].
This feature allows you to ignore exceptions when they
occur on certain registers.As an example, you may have
one register dedicated specifically to returns, so you’ll
want to ignore refund transactions at this register
because they occur constantly. The delete register mask
option works coincidentally with your programmed
exceptions.You will “link” certain exceptions to certain
registers with this feature.
This feature is similar to the delete register mask except
that it allows you to respond to an exception only if it is
linked to a register on this list.
Upon pressing [3], you’ll see the same kind of prompts
as you did with the delete register mask function:
(1)=Edit list (2)=Edit link (ESC)=Exit
Upon pressing [2], you’ll see the following prompt:
(1)=Edit list (2)=Edit link (ESC)=Exit
Pressing [1] will allow you access to the apply register
mask list, which is configured the same as the delete
register mask list:
To edit the list, press [1] again.You will see the prompt:
ESC to exit or ENTER to edit !
1. ESC to exit or ENTER to edit !
Press [ENTER], and the monitor will scroll a list of
item numbers. If none have been programmed, it will
just list the first item number:
If you wish a particular exception to be accepted only
when it applies to a specific register, enter the register
number now at the first item number. Do this for as
many registers as you need. Again, you can enter up to
10 registers.
1. ESC to exit or ENTER to edit !
Press [ENTER] again. The cursor will position itself
next to line item number one. Enter the register number
you want linked with an exception. Linking tells the
Inter-Check unit to ignore an exception for a selected
POS terminal. Up to 10 registers may be entered in the
edit list. Press [ESC] to skip a line. [ENTER] will
end the programming session.
To link your register(s) to an exception, you must enter
the edit link function by pressing [2]. The procedure to
link the register and exception is exactly the same as in
the delete register mask sequence, except now you’re
telling Inter-Check: “Only when this exception is met
on this/these register(s), do I want it flagged as an
exception. Otherwise, ignore this exception”.
To “link” the register and exception line together, from
the delete reg. Mask prompt you must press edit link
(2). Upon hitting 2 you will see the following:
1=Off 2=Off 3=Off 4=Off
Please note that if an exception is not linked to either
the delete register mask or apply register mask function,
then it will be treated as a normal exception.
5=Off 6=Off 7=Off 8=Off
9=Off 10=Off 11=Off 12=Off
13=Off 14=Off 15=Off 16=Off
ESC to exit or ENTER to edit !
A register should never be linked to both the delete
register mask and apply register mask functions. If it
is, the delete register mask function will have priority.
You can enter up to 16 exceptions during exception
programming. Each one has a corresponding number,
which is represented on this screen. Use this feature to
tell Inter-Check which exception(s) you want linked to
your previous list of registers you programmed in. Upon
pressing [Enter] the monitor will display:
5.2 SYS SAVE/SYS READ
Press the [0] key from the SELECTION MENU. Press
the [1] key (SYSSAVE).You may have to wait several
seconds to allow the Inter-Check to do the save. The
Inter-Check unit will beep once when it is done saving
your current parameters to nonvolatile memory.
ESC to Link or CR to Unlink 1=Off
If you would like exception number one to be “linked”
to the register(s) from your edit list, press [ESC]. The
Screen will change to:
ESC to Link or CR to Unlink 1=Off On 2=Off
20
Pelco Manual C1043M-A (2/96)
6.0 HOT KEY SUMMARY LIST
[ESC] STANDBY MODE [ESC]
Puts the data in Standby mode and clears existing
data from the screen. This provides a clear view of
the video picture. [ENTER] returns to the monitor-
ing mode. This function clears the communication
lines and buffers.
[B] BLOCK SELECT
Used to select polling for a block of two (2) or four
(4) groups of registers.
[C][I] CLEAR COMMUNICATIONS
Clears Communication to PIMs and ICI3000P.
[F1] REGISTER SELECT
This function allows a specific register to be moni-
tored continuously (see Section 4.1).
[E] EXCEPTION FOLLOW ON/OFF
The [E] key turns on the Exception Follow sequence
for Screen 1. When an exception occurs, the unit will
continue to monitor the POS terminal until an ex-
ception occurs on another terminal. When activated,
the following prompt will be displayed:
[F2] OPERATOR SELECT
This function allows a specific POS terminal opera-
tor to be continuously monitored (see Section 4.2).
[F3] EXCEPTIONS ON/OFF
This function turns on/off the exception monitoring
(see Section 4.3).
0000=EXF1>V S
If you wish to monitor a particular register while wait-
ing for an Exception to happen you can simulta-
neously use the [F1] Hot Key. With Exception Fol-
low, both screens are used to look for Exceptions.
Remember, Exceptions must be turned on in order
for the [E] key to work.
[F4] EXTERNAL PRINTER ON/OFF
This function turns on/off the external printer and
prints the text currently displayed on the monitor.
After pressing [F4], press [1] or [2] to select the
screen to be printed. A “P” will appear on the status
line of the screen you have selected. Inter-Check will
prompt: “Printer On” or “Printer Off” for current
printer status. Pressing [F4] and the screen number
again will turn off the printer as indicated by the dis-
appearance of the “P”. The ICI3000P will only print
to the external printer for the last screen selected (see
Section 4.5).
[G] GROUP SELECT
Toggle between register groups 1 and 2, or 1 and 4.
[L] EXCEPTION COLUMN LINE ON/OFF
Turns on a row of numbers called an Exception Col-
umn Line which is used for programming Excep-
tions. This feature is especially useful when attempt-
ing to program Column Specific Exceptions.
[F5] PRINTER DUMP
This function is similar to the F4 function, except it
will print 40 lines of data previous to the current dis-
play. Printing will continue until turned off. This fea-
ture is used for capturing important information that
may have scrolled off the screen.
[R] MAIN REGISTER for exception follow.
[S] SEQUENCING ON/OFF
The [S] key works as a toggle switch, turning on
and off the “Sequencing” of the Inter-Check switcher.
You can still use the hot key combination [F9], [F9]
to manually select an item from the Shadow List.
Each time you press the [S] key, Inter-Check will
beep and display a prompt informing you of the cur-
rent settings.
[F6] FREEZE FRAME
This will “freeze” all action on the screen, both video
and data text. Pressing [F6] again will “unfreeze”
text.
[F7] SMALL SCREEN/LARGE SCREEN
TOGGLE
Depressing this key will toggle your data screen dis-
play from Small Screen Text Window parameters to
the Large Screen TextWindow parameters. Remem-
ber, you can program the number of lines you want
displayed for Small and Large Screen (Large screen
17 lines only.) (See Section 4.8.2 - 4.8.4).
Pelco Manual C1043M-A (2/96)
21
[F8] PAGE BACK/PAGE FORWARD TOGGLE
This option allows you to look back one page of text
on your monitor to verify data. By using this key
you will automatically force the unit into large screen
mode. Pressing [F8] again will bring back the cur-
rent page of text. The active page will show the cur-
sor at the bottom of screen.
[F9] CAMERA SELECT
This function selects a video input from the ports
labeled “VIDEO IN” on the ICI3000P, a selected
input from the ICI3008/ICI3016 camera list or no
video which is defined as internal sync (see Section
4.4 and 4.8.9).
[F10] REVERSE VIDEO ON/OFF
This feature changes the visual characteristics of the
data displayed by placing a black background around
the video characters (see Section 4.7).
[F11] SCREEN DATA DUMP
This feature will send all data currently displayed on
the monitor and any data following to the printer.
No data will be displayed on the monitor until the
[F11] key is pressed again. In order to activate the
data dump, press [F11] followed by the desired
screen (1 or 2).
[F12] AUTO CAMERA SEARCH ON/OFF
Monitors camera system’s sync generation. If moni-
toring camera loses power or is disconnected, the
system will switch to the next camera for synchroni-
zation. If active video is not detected, the system will
switch to “internal sync” (see Section 4.6).
22
Pelco Manual C1043M-A (2/96)
7.0 TROUBLESHOOTING
Problem: No video displayed on the monitor.
This section covers some basic troubleshooting
examples and possible solutions for each. Consult this
section first before calling your PELCO representative.
Solution: If using more than one camera (i.e.,
Shadow Switcher), make sure that your
auto camera search feature is turned OFF.
Refer to Section 4.8.10 for information
on how to operate this feature.
Problem: ICI3000P unit does not receive data.
Turn on the monitor.
Solution: Make sure that the data cable is plugged
into the DATA INPUT of the ICI3000P
unit. Check baud rate.
Check cabling and verify that the camera
and monitor cables are inserted into the
unit properly.
Problem: Inter-Check unit displays :
KEYBOARD TRANSMIT TIMEOUT
NO ACK FROM KEYBOARD
Problem: No power to the ICI3000P; the red power
LED indicator is not lit up.
Solution: Make sure that your keyboard is IBM/
Solution: Make sure power supply is plugged into
AT compatible.
the unit properly.
Ensure that the outlet or power strip is
powered.
Problem: Text on the right side of the screen
overlaps with text on the left side.
Solution: Your large and small text screens are set
up improperly. Refer to Sections 4.8.1-
4.8.4.
Problem: Vibrating text
Solution: Adjust the Video Gain potentiometer.
Problem: Printer prints strange characters
Problem: Text on screen 2 is being “cut off” on the
right side of the monitor.
Solution: Make sure that the baud rate of the Inter-
Check unit matches the baud rate of the
printer. The unit defaults to 9600 baud
so the printer must also be programmed
for 9600 baud.
Solution: Adjust the Size (S) potentiometer on the
bottom of the ICI3000P. Turn this control
all the way counterclockwise to achieve
the smallest character size. Refer to
Section 3.4 for a better description of this
feature.
Check the number of characters per line
you have programmed in for each screen.
Check Large and Small screen data
positions to ensure that they do not
overlap.
Pelco Manual C1043M-A (2/96)
23
8.0 POWER-UP PROCEDURE FOR THE
ICI3000P
5. Check all programming to confirm that the memory
was retained. To reenter any programming that may
have been lost, make sure that the NV switch on
the underside of the ICI3000P unit is in the “un-
locked” position (i.e., away from the BNC con-
nectors on the back of the unit. Lock the NV switch
when programming is complete.
In the event of a power failure, the Inter-Check System
has a nonvolatile memory and will retain all memory
that has been previously saved. Some program func-
tions, in order to be used, will have to be activated us-
ing the hot keys.
6. Execute a “System Save” to retain programming
information. To exit out of the Monitoring Mode,
press “Enter”. Select the Menu and press [0] to
save.
Following is a power-up procedure checklist to be fol-
lowed in the event that the Inter-Check system experi-
ences a power outage.
1. Check all cables (power, video, data, alarm, etc.);
make sure all connections are intact.
7. To reactivate the functions you need, use the Hot
Key Summary List on page 19 of the ICI3000P
manual. Press the corresponding Function Keys
(“S” to sequence, for example), while in the Moni-
toring Mode.
2. Power down and then power up the ICI3000P to
make sure system defaults have loaded and initial-
ized correctly.
3. Turn on the “Auto Camera” feature by pressing
[F12] or by pressing [Enter] from the select
menu and [6] to select Auto Camera ON. Turn the
video ON if the monitor is blank by pressing [P]
while in the Monitoring mode. Then press [F9]
again followed the camera in the Shadow List that
you wish to view.
4. Poll the ICI1000PIM units to make sure that they
are communicating by pressing [P] while in the
Monitoring mode. Then press [I] to initialize the
poll. If some units do not answer, check all system
cables for loose connections.
24
Pelco Manual C1043M-A (2/96)
9.0 SPECIFICATIONS
Video Bypass:
5 volt dry contact relay passes video to
input 1
Weight:
3 pounds
Switch:
Video output upon power loss
Dimensions:
Length = 9.50 inches
Width = 5.75 inches
Height = 1.50 inches
DATA INPUT:
Keyboard Input: IBM/ATcompatible-inputsfilteredwith
470 ohm pullups and 220 pf. caps.
Operating
Temperature:
35° F to 95° F
Alarming
Storage
Outputs 1 and 2: Optoisolated up to 3000 volts
Temperature:
-4° F to 140° F
Real Time
Operating
Humidity:
Clock:
Year, Month, Day Hours, Minutes, Sec-
onds. Accuracy is approximately 2 sec-
onds per year. Battery backup of 1 year
off load power or 2 year power on load
20% to 80% non-condensing
ELECTRICAL SPECIFICATIONS:
FCC Approved: This equipment has been tested with a
CLASS A computing device and has been found to comply
with part 15 of FCC rules. Operation in a residential area
may cause unacceptable interference to radio and TV recep-
tion requiring the operator to take whatever steps are neces-
sary to correct the interference. (45 FR 24165, APR 9 1980)
Battery type:
Lithium type, 3 volts @ 160 MA
Non-Volatile
Memory:
May be corrupted by large magnetic
fields or x-rays. Write protected switch
for power surges and intermittents
Power Input:
5 volts DC ±3%
Fused at 1.0 amps surge
Video Character
Display:
Standard Option: Max. of 17 lines per
screen. Max. of 80 characters per line
Power Supply:
120 volts AC @ 15 watts in - 60 Hz
5 volts DC @ 1.0 amps out
5% line load regulation
Programmable
Exception
Flagging:
15 lines of exceptions possible.
10 Transaction types possible.
Each line may contain up to 60
characters.
Frequency:
50 Hz - 60 Hz.
Video Inputs:
Video Output:
(2) 75 ohm NTSC/PAL, BNC Connect
(1) 75 ohm NTSC/PAL, BNC Connect
Video Adjustment
Potentiometers:
(H) Horizontal position fine tune
(V) Vertical position fine tune
Camera Switch: Switch on vertical of displayed signal.
Dwell time accuracy = ± .1 second
(S) Horizontal character size
(I) Character intensity
(G) Video Gain
Internal
Standard Option: Composite NTSC
Synchronization: Vertical = 60 Hz @ 260µs
Horizontal = 15.36 KHz@ 4.38 µs
Alternate
PAL option:
Vertical = 50 Hz @ 260 µs
Horizontal = 15.36 KHz @ 4.38 µs
Pelco Manual C1043M-A (2/96)
25
9.1 OUTPUT DEFINITIONS
WIRE COLOR
White
PIN DESIGNATION
DESCRIPTION
+5 volts (For testing only)
Signal Ground
1
2
3
Black
Red
RS232 Current Loop
CHANNEL 1 INPUT
Green
4
5
NOT USED
Yellow
(Opto y-jack input)
ICI1000PIM Input for
CHANNEL 1
Blue
6
NOT USED
AUXILIARY PORT 1 (Printer Port)
Communications = Standard RS232 Asynchronous
9600 Baud
8 bits
No Parity
AUXILIARY PORT 2 (Shadow Switcher/Dome Port)
Communications = Standard RS232 Asynchronous
9600 Baud
8 Bits
No Parity
9.2 DB9 PINOUT
PIN #
DESCRIPTION
1
NOT USED
RX AUX 1
2
3 (Printer port)
TX AUX 1
4
NOT USED
SIGNAL GROUND
NOT USED
RX AUX 2
5
6
7
8 (Dome-Shadow port)
9
TX AUX 2
NOT USED
26
Pelco Manual C1043M-A (2/96)
10.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
RETURNS
Pelco will repair or replace, without charge, any merchandise proved
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate
of shipment.
In order to expedite parts returned to the factory for repair or credit, please
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an
authorization number (CA number if returned for credit, and RA number
if returned for repair).
Exceptions to this warranty are as noted below:
All merchandise returned for credit may be subject to a 20% restocking
and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid. Ship to the
appropriate address below.
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and
keyboard).
Three years on Camclosure® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
•
If you are located within the continental U.S., Alaska, Hawaii or Puerto
Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto
Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
•
•
•
Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura™ Series distributed
network-based video products.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
•
•
One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods
to:
Six months on all pan and tilts, scanners or preset lenses used in
continuousmotionapplications(thatis,presetscan,tourandautoscan
modes).
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco will warrant all replacement parts and repairs for 90 days from the
date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to Pelco, Clovis, California. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident are not covered
under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or
loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract,
negligence, infringement of any rights of any party or product liability,
relating to the Products shall not exceed the price paid by the Dealer to
Pelco for such Products. In no event will Pelco be liable for any special,
incidental or consequential damages (including loss of use, loss of profit
and claims of third parties) however caused, whether by the negligence
of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The
Dealer may also have additional rights, which are subject to variation from
state to state.
Ifawarrantyrepairisrequired,theDealermustcontactPelcoat(800) 289-
9100 or (559) 292-1981 to obtain a Repair Authorization number (RA),
and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall
under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by
which the item was received by Pelco.
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 1996, Pelco. All rights reserved.
Pelco Manual C1043M-A (2/96)
27
®
PELCO
3500 Pelco Way
Clovis, CA 93612-5699 USA
(559) 292-1981 • (800) 289-9100
FAX (800) 289-9150 or (559) 292-3827
International customers call 1-559-292-1981
or FAX 1-559-348-1120
(Product specifications subject to change
without notice.)
C1043M-A
28
Pelco Manual C1043M-A (2/96)
|