O W
N
E
R '
S
M
A N
U
A L
HCA-3500 Ultra High Current Power Amplifier
H C A- 3 5 0 0 U l t r a H i gh C u r r en t P ow er Am p l i f i er
er
Pow
er
Pow
Right
Left
Designed in California by John Curl
IMPORTANT SAFETY INSTRUCTIONS
The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to
the presence of “dangerous voltage” inside the product that may constitute a risk of electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance instructions in the literature accompanying the product.
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
1. Read Instructions — Read all the safety and operating instructions before operating this product.
2. Retain Instructions — Retain safety and operating instructions for future reference.
3. Heed Warnings — Adhere to all warnings on the product and in the operating instructions.
4. Follow Instructions — Follow all operating and use instructions.
5. Cleaning — Unplug this product from the wall outlet before cleaning. Use a damp cloth for cleaning. Clean the
outside of the product only.
6. Attachments — Do not use attachments that are not recommended by the product manufacturer; they may be
hazardous.
7. Water and Moisture — Do not use this product near water.
8. Accessories — Do not place this product on an unstable cart or stand. The product may fall causing bodily injury
and damage to the product. A product and cart combination should be moved with care. Quick stops, excessive
force, and uneven surfaces may cause the product and cart to overturn.
9. Ventilation — Slots and openings in the cabinet are provided for ventilation to ensure reliable operation of the
product and to protect it from overheating. These openings must not be blocked or covered. This product should not
be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided.
10. Power Sources — Operate this product only from the type of power source indicated on the label. If you
are not sure of the type of power supply to your home, consult your dealer or local power company. This product is
equipped with a three-prong grounding plug. This plug will only fit into a grounding power outlet. If you
are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the
safety purpose of the grounding plug.
11. Power Cord Protection — Power supply cords should be routed so that they are not likely to be walked on or
pinched by items placed upon or against them.
12. Lightning— Unplug the unit from the wall outlet for added protection during a lightning storm and when it is left
unattended and unused for long periods of time. This will prevent damage to the product due to lightning and power
line surges.
13. Overloading — Do not overload wall outlets or extension cords. This can result in a fire or electric shock.
14. Inserting Objects into Unit - Never push objects of any kind into this product through any openings; they may
touch dangerous voltage points or short out parts that could result in fire or electric shock.
15. Servicing — Do not attempt to repair or service this product yourself. Opening or removing covers may expose you
to dangerous voltage and other hazards. Refer all servicing to qualified service personnel.
16. Damage Requiring Service — Unplug this product from the wall outlet and refer servicing to qualified service
personnel under the following conditions: a) If the power-supply cord or plug is damaged. b) If liquid has been
spilled into the product. c) If the product has been exposed to rain or water. d) If the product does not operate
normally by following the operating instructions. e) If the product has been dropped or damaged in
any way. f) If the product exhibits a distinct change in performance.
17. Replacement Parts — When replacement parts are required, be sure the service technician has used replacement
parts specified by the manufacturer. Unauthorized substitutions may result in fire, electric shock, and other hazards.
19. Safety Check — Upon completion of any service or repairs to this product, ask the service technician to perform
safety checks to determine that the product is in proper operating condition.
20. Wall or Ceiling Mounting — Mount the product to a wall or ceiling only as recommended.
21. Heat — The product should be situated away from heat sources such as radiators, heat registers, stoves, and other
products (including amplifiers) that produce heat.
-3-
Figure #1 HCA-3500 Front and Rear Panel Drawings
H C A- 3 5 0 0 U l t r a H i gh C u r r en t P ow er Am p l i f i er
Rack
Mount Holes
erload
Right
Ov
Temp
High
Left
Operation Status
Indicators
Left Power Switch
Right Power Switch
Carry Handle
Normal and Bi-Wire
Speaker Connectors
Same as Right Channel
Right Channel
Left Channel
Right Speaker
Left Speaker
Non-Inverting
Non-Inverting
Non-Inverting RCA Input Jack
Unbalanced Inputs
Unbalanced Inputs
Inverting
Inverting
Inverting RCA Input Jack
Input Selection Switch
Bi-Wire
Bi-Wire
Input Selector
Balanced Unbalanced
Input Selector
Unbalanced Balanced
HCA - 3500
Ultra High Current Power Amplifier
Parasound Products, Inc
San Francisco, CA U.S.A.
Balanced XLR Connector
Balanced Input
Balanced Input
CAUTION
TO PREVENT ELECTRIC
SHOCK, DO NOT REMOVE
THE COVER. THERE ARE
NO USER SERVICABLE
PARTS INSIDE. REFER
SERVICING TO QUALIFIED
SERVICE PERSONNEL
WARNING
TO PREVENT FIRE
OR SHOCK HAZARD,
DO NOT EXPOSE THIS
UNIT TO RAIN OR
MOISTURE. DO NOT
RESTRICT ADEQUATE
VENTILATION.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AC 120V
50/60Hz
Power Consumption: 1200
W
Power Consumption: 1200
W
Fuse T15A/250
V
Fuse T15A/250
V
Main Power Fuse
Carry Handle
IEC AC Cord Connector
-4-
Introduction
Congratulations on your purchase of this precision audio component and thank you for your selection of
Parasound.YourParasoundHCA-3500wasdesignedbyrenownedcircuitdesignerJohnCurlandisbuilt
using only the finest precision components available for optimum musical quality and performance.
Eachchanneloftheamplifierhasitsownpowersupplyincludinganindependent1.4kVAtoroidalpower
transformer and 97,600 uF of filter capacitance. This dual-mono configuration provides the high levels
of power needed for some of today’s more sophisticated speaker systems. The inherently low output
impedance of the HCA-3500 easily maintains control of your loudspeakers even during demanding
impedance variations.
Unique circuit topology of the direct coupled HCA-3500 includes balanced JFET input transistors,
MOSFET drivers and ultra high current output devices. The output delivers a generous 15 watts of pure
class A operation. Additionally, there are no inductors or capacitors in the signal path. These design
refinements reduce high odd-order harmonic distortion, improve overall clarity and preserve low-level
musical details.
Please take a few moments to read these instructions so that you may fully understand the capabilities
of your new Parasound power amplifier.
Unpacking Your HCA-3500
Carefully unpack your amplifier and remove all the enclosed accessories. These accessories include two
12 AWG AC cords, rack mount hole plugs, and this manual. Be sure to inspect the unit for any possible
shipping damage. If you see any, contact your Parasound Dealer immediately. Save all the packing
material in case you need to ship the amplifier for repair. Before you proceed, find the serial number
located on the rear panel of your amplifier and record it here for reference:
Serial #____________________
Date of Purchase____________________
Installing Your HCA-3500
Locateyouramplifierawayfromheatsourcessuchasairductsandradiators.Alwaysmounttheamplifier
horizontallyandmakesurethatyourcabinetorshelfcansupportitsweight. Itisbesttoprovideaseparate
shelf for your amplifier rather that stacking it directly above or below your other components.
TheHCA-3500occupiesfourrackspaces(7")inastandard19inchequipmentrack.Whenrackmounting
the HCA-3500, have someone help support the unit while you bolt the component to the rack rails. Be
sure to use heavy duty mounting bolts and nylon shoulder washers on both sides of the faceplate to avoid
scratching the amplifier’s front panel and also to help prevent ground loops. Contact Middle Atlantic
Products at (201) 839-1011 to obtain any additional rack mounting hardware you may need.
-5-
Ventilation Requirements
To insure safe and reliable operation, it is very important that the amplifier has plenty of ventilation to
prevent overheating and automatic shut down from its thermal protection circuitry. Please observe the
following ventilation guidelines when installing your amplifier in a cabinet or other enclosed area:
1) If you are not using a fan, allow at least six inches on each side and above the amplifier, and do
not close off the front with a cabinet door or panel.
2) If you are enclosing the amplifier within an equipment cabinet, use a fan to draw in cool air and
exhaust warm air. Two vent holes are required: one for intake and one for exhaust.
3) Do not place the amplifier on carpeting that will obstruct the air flow into the bottom of the
amplifier chassis and heatsinks.
4) Avoid stacking components. If you do stack components, you must use a fan to circulate the
warm air that will quickly become trapped between them when they are powered on.
Making Connections to the HCA-3500
Refer to Figure #1
Leave the AC cords disconnected before making any signal or speaker connections. When making
connections to the amplifier, make sure there is no strain or tension on the input leads, speaker wires, or
AC cord that could cause them to pull loose.
RCA Jack Input Connections
You can connect the output of your preamplifier or processor to the RCA input jacks in a variety of ways:
Normal Unbalanced Non-Inverting Input
Connect the unbalanced outputs of your preamplifier to the left and right positive (+) inputs only. With
this connection, the HCA-3500's output is non-inverted; a positive signal at the input results in a positive
signal at the output.
Unbalanced Inverting Input
Connect the unbalanced output of your preamplifier to the to the left and right negative (—) inputs only.
Withthisconnection,theHCA-3500'soutputisinverted;apositivesignalattheinputresultsinanegative
signal at the output.
Balanced RCA Inputs
Connect the left and right positive (+) output of your preamplifier to the left and right positive (+) inputs
of the HCA-3500 and connect the left and right negative (—) output of your preamplifier to the left and
right negative (—) inputs of the HCA-3500. These balanced connections provide an alternative to using
an XLR connector if your preamplifier is equipped with (+) and (—) RCA output connectors.
XLR Input Connections
If your preamplifier is equipped with balanced XLR output connectors, you can use these connections
as an alternative to the RCA jacks. The industry standard pin assignment for the
HCA-3500's XLR input connector is Pin 1: Ground, Pin 2: Positive (+), and Pin 3: Negative (—).
-6-
Input Selector Switch
Once you have decided which input connectors you will use, set the input selector switches to their
Unbalanced or Balanced XLR position.
Speaker Connections
YoumayconnectbarewireuptoAWG12, speakerwireterminatedwith1/4"spadelugs, orbananaplugs
to the five-way binding posts of your power amplifier. If you use bare wire without terminals, make sure
you remove only enough insulation so the wire can fit through the hole that runs sideways through the
terminal’s binding post. Before inserting the wire, twist all its strands tightly to prevent strays that could
cause a short circuit. (You may want to "tin" the stripped wire with solder to prevent it from fraying and
oxidizing.)
Bi-Wiring
The HCA-3500 is equipped with an additional set of binding posts to facilitate bi-wiring. These extra
speaker connectors are in parallel with the main binding posts. If your loudspeakers have two sets of
speaker connectors, you can bi-wire by connecting two sets of speaker cables from each channel of your
HCA-3500 to your speakers. Bi-wiring effectively reduces the lead resistance of your speaker wire thus
diminishing power loss and improving damping factor. The extra set of binding posts also make it easy
to connect an additional pair of speakers.
Observing Correct Polarity
When you connect speakers to your amplifier, you will notice that one side of the two conductor speaker
wire will have some sort of mark: either printing, a raised ridge on the insulation, or a different color of
conductor to let you know which wire to connect to the positive and which to the negative speaker
terminals so you can repeat the connection on the power amplifier's binding posts.
Minimum Speaker Impedance Precautions
Although the HCA-3500 is capable of driving speakers with occasional impedance dips well below
2 Ω, it is primarily designed to drive loudspeakers with a 4 Ω or 8 Ω nominal impedance. This is because
sustainedhighpoweroperationintoloadsoflessthan4 Ωmaycauseoverheatingandsubsequentthermal
shutdown.
AC Power Connections and AC Grounding
Before you connect the AC cords, make sure the HCA-3500's power switches are in the off or down
position. If possible, plug your amplifier directly to an AC wall outlet. Be sure to plug both AC cords into
the same outlet help prevent possible ground loops. Do not connect the AC cords to the accessory AC
outletonyourpreamplifierbecausetheamplifier'scurrentdrawexceedstheratingsofmostpreamplifier’s
power switches and power cords. If you use an external AC line conditioner or surge suppressor, make
sure it can withstand the HCA-3500's power requirements listed in the specification section of this
manual.
-7-
Operating the HCA-3500
Refer to Figure #1
Power Switches
Thereareseparatepowerswitchesfortheleftandrightchannels.Presstheuppersidetoturneachchannel
on; press the lower side to turn each channel off.
Bi-Color Channel Status Indicators
When you first turn the power switches of the HCA-3500 on, the Left and Right channel status indicators
will light red for about five seconds while the internal circuits are stabilizing. After that, these indicators
will change from red to green to signal that bothe channels are operational. Either the Left or Right
channel status indicator may change from green to red if there is a fault that triggers the protection
circuitry.Thismayindicateoneofthefollowingconditions:DCpresentattheamplifier'sinput,aspeaker
impedance overload, a short circuited speaker line, or a possible internal fault. If either indicator changes
to red, remove power to the amplifier and check all connections. During this time, the protection circuits
should automatically reset. If either Left or Right channel status indicators remain red after you reapply
power, contact your Parasound Dealer, Installer, or Parasound Technical Service Department for further
advice.
Current Overload Indicator
These indicators let you know if there is too low of an impedance at the amplifier's output thereby
exceedingtheamplifierscurrentcapacity. Duringnormaloperation, thebi-colorLeftandRightchannels
indicators for the will be green and the Current Overload indicator will remain off. If either channel is
driven beyond its maximum current capacity because the impedance for that channel is too low, the
Current Overload indicator will light red and the affected channel's indicator will change from green to
red.
High Temp Indicator
This indicator will light when either of the external heatsinks reaches 90 degrees centigrade. If the High
Temp indicator lights, it probably means that the amplifier has inadequate ventilation. If either channel
is driven beyond its thermal capacity, the High Temp indicator will light red and the affected channel's
indicator will change from green to red. Refer to page 6 for more information about proper ventilation.
Once the heatsink cools below 90 degrees, the amplifier channel will automatically reset and resume
normal operation.
Maintaining Your Parasound Amplifier
Your Parasound power amplifier requires no periodic maintenance and has no user serviceable parts
inside. Toavoidtheriskofelectricshock, donotremovethetopcover. Theamplifier'sexteriorcaneasily
be cleaned with a soft cloth moistened only with a few drops of water or glass cleaner.
Main Power Fuses
There is an external fuse for each channel on the rear panel. These fuses protect the unit from possible
damage to internal parts. Never replace fuses with a higher value than installed from the factory.
Substitution of larger fuses may create serious stress and damage to internal parts and will void your
warranty.
-8-
In Case of Trouble
If you suspect a problem with your amplifier, first turn the amp off and check all your connections. The
trouble may be caused by another component or even a defective hookup cable. If you are hearing hum
out of your speakers, turn off the amplifier and disconnect the inputs to it. If the hum goes away, when
you turn the amplifier back on it was probably be caused by your preamplifier or one of the source
components connected to it. Also, make sure that both AC cords are connected to the same AC outlet.
In rack mounted systems, ground loops and hum can sometimes develop via the metal rack rails of the
equipmentrack. Thisproblemcanbesolvedwithnylonshoulderwashers(refertorackmountingsection
of this manual).
If All Else Fails...
CallyourParasounddealerorParasoundTechnicalServiceDepartment.Wecansuggestotherdiagnostic
tests you can easily perform. If we determine that your amplifier should be returned to Parasound or an
Authorized Parasound Warranty Center for inspection and possible servicing, call Parasound for the
location of a warranty center near you. If you choose to send it to Parasound, contact us to obtain a Return
Authorization (RA) number. You will be asked to repack the unit in its original packaging including the
additional outer box for protection during transit. The RA number must be clearly marked on the outer
cartononly.YoushouldshiptheunitbyUPSwithadequateinsuranceandacopyofyourpurchasereceipt
to validate your ownership.
Units that arrive without your specific RA number, without a suitable shipping carton or with evidence
of improper internal packing may be refused. We do not accept collect shipments. After repair under
warranty, the unit will be returned to you via prepaid UPS within the Contentinental United States. In the
case of a non-warranty repair, contact us and we will advise you of the repair charges before you ship the
unit to us. The same packing and Return Authorization number requirements apply.
-9-
Parasound HCA-3500 Specifications
Continuous Power Output
350 watts RMS per channel from 20 Hz-20 kHz into 8 Ω, both channels driven
500 watts RMS per channel from 20 Hz-20 kHz into 4 Ω, both channels driven
Current Capacity
120 amps peak per channel
Slew Rate
> 130 V/µS
Power Bandwidth
2 Hz-150 kHz, +0/-3 dB at 1 watt
Total Harmonic Distortion
< 0.05 % at full power; < 0.01 % typical levels
Intermodulation Distortion
< 0.03 %
Transient Intermodulation Distortion
Unmeasureable
Dynamic Headroom
> 1.5 dB
Interchannel Crosstalk
> 95 dB at 1 kHz
> 80 dB at 20 kHz
Input Impedance
100 kΩ
Input Sensitivity
1.4 V for 100 watts output
2.25 V for full output
Gain
31 dB
Signal to Noise Ratio
> 115 dB, input shorted, IHF A-weighted
Damping Factor
> 1000 at 20 Hz
Power Requirements
110 Vac-120 Vac 1200 watts per channel
Dimensions
19" wide x 7" high x 18" deep (7 3/4" high with feet)
Weight
80 lb Net
-10-
|